Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Total Environ ; 317(1-3): 137-47, 2003 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-14630417

RESUMO

In this paper a source apportionment of particulate matter pollution in the urban area of Milan (Italy) is given. Results of PM10 and PM2.5 mass and elemental concentrations from a 1-year monitoring campaign are presented. Mean annual and daily PM10 levels are compared with the limits of the EU Air Quality Directive EC/30/1999 and the results show that the limit values established would not be met in the urban area of Milan or the large surrounding area. Moreover, high levels of PM2.5 are registered and this fraction constitutes a high portion of the PM10 mass. In Milan the winter period is characterised by a high degree of air pollution due to a greater contribution of emissions and to adverse meteorological and thermodynamic conditions of the atmosphere. The application of multivariate techniques and receptor modelling (PCFA, APCFA) to the whole data-set led to the identification of the main emitting sources and to the source apportionment of PM10 and PM2.5 in Milan. The most important sources were identified as 'soil dust', 'traffic', 'industry' and 'secondary compounds' for PM10 and as 'soil dust', 'anthropogenic' and 'secondary compounds' for PM2.5, explaining the greatest part of the total variance (91% and 75%, respectively).

2.
J Environ Radioact ; 65(1): 77-90, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12683729

RESUMO

Continuous measurement of hourly concentrations of 212Pb attached to aerosol particles was carried out during the whole year 2000 in the outdoor air of Milan (Italy). An improved experimental method based on on-line alpha spectroscopy during atmospheric particulate matter sampling allowed the contemporary determination of 212Pb and 214Bi through the deconvolution of the alpha energy spectral distribution analysis. The 212Pb hourly concentrations were about 100 times lower than 214Bi but showed a similar characteristic diurnal time trend. However, the influence of meteorological parameters such as rain and wind was more evident in 212Pb than in 214Bi concentrations. The 212Pb average annual concentration was 0.090 +/- 0.060 Bq/m3 with daily mean concentration varying from 0.013 to 0.333 Bq/m3.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Bismuto/análise , Radioisótopos de Chumbo/análise , Radioisótopos/análise , Aerossóis , Cidades , Monitoramento Ambiental , Itália , Tamanho da Partícula , Análise Espectral , Fatores de Tempo
3.
J Environ Radioact ; 65(2): 147-60, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12527232

RESUMO

The results of a survey of outdoor radon concentrations in Milan are reported. Measurements were performed hourly over a continuous four year period from January 1997 to December 2000. Radon concentration was obtained by two means: both direct measurement of radon; and measurement of its decay products. The average daily pattern of radon concentration featured a minimum in the late afternoon and a maximum in the early hours of the morning. A seasonal pattern with higher concentrations in winter than in summer (from around 15 Bq m(-3) in winter to around 5 Bq m(-3) in summer) was also observed. Similar average annual values of around 10 Bq m(-3) were obtained. The annual effective outdoor radon dose was found to be 0.12 mSv. The variation from minimum in the afternoon to maximum the following morning was found to be a good indicator of the height of the nocturnal mixing layer. The variation between maximum and minimum levels on the same day is an index of the maximum height of the mixing layer. Furthermore, our long term measurements of radon have permitted us to examine the dispersion characteristics of the atmosphere over Milan, and to establish the frequency of conditions unfavourable to the dispersion of atmospheric pollutants.


Assuntos
Poluentes Radioativos do Ar/análise , Radônio/análise , Movimentos do Ar , Coleta de Dados , Monitoramento Ambiental , Itália , Periodicidade , Estações do Ano
4.
Sci Total Environ ; 298(1-3): 65-79, 2002 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-12449330

RESUMO

Results obtained during a winter field campaign for the fine fractions of particulate matter are presented. A high pollution episode together with an analysis of the main factors, which influence accumulation of pollutants is described. The measurement campaigns were carried out simultaneously at two sites in Northern Italy, Milan and Erba, during the winter of 2000. The daily variability in the mass concentration values and PM2.5/PM10 ratios appeared to be strongly dependent upon meteorological and atmospheric stability conditions and, in particular, wind regimes. During the intensive field campaign a high-pollution episode occurred that led to TSP and fine fraction concentrations well above the attention and alarm thresholds, reaching values of up to 200-250 microg m(-3). The elemental concentrations were determined by ED-XRF analysis. The elemental composition of the particulate matter indicated that crustal matter oxides (soil dust) were the main component in particles with aerodynamic diameter d(ae) > 10 microm. They were an important part also in particles with 2.5 < d(ae) < 10 microm, but strongly decreased in particles with d(ae) < 2.5 microm. In the finer fraction sulphates nitrogen and carbon compounds played a major role. The temporal patterns of mass and elemental concentrations, as well as the main components of PM were very similar at the two sites. The high-pollution episode was recorded at many locations in the Po plain, highlighting the role of meteorology and thermodynamic atmospheric conditions on pollution build-up on a large area.


Assuntos
Aerossóis , Poluentes Atmosféricos/análise , Cidades , Monitoramento Ambiental , Itália , Conceitos Meteorológicos , Tamanho da Partícula , Estações do Ano , Termodinâmica
5.
Arch Gerontol Geriatr ; 15 Suppl 1: 27-35, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-18647674

RESUMO

It is well-known that bone volume decreases with age both in normal subjects and particularly in osteoporotic patients. It is not well demonstrated, however, whether bone loss is associated with changes in the composition of bone tissue and especially with altered concentration of mineral elements. To verify whether calcium density changes with aging, autoptic specimens, of iliac crest trabecular bone from 20 normal subjects between 21 and 66 years, 10 males and 10 females were analyzed by using a new method which allows the measurement of calcium density in a non-destructive way, on entire histologic sections of the bone. Bone specimens were embedded in araidite and tissue sections, about 3 microm thick and 4x4 mm size, were mounted onto polyvinyl acetate films and analyzed by PIXE (proton induced X-ray emission) using the CISE setup for calcium content determination. The same bone tissue sections were then mounted on glass slides, stained with the Von Kossa method and the volume of calcified bone was measured with a semiautomatic image analyzer (Videoplan). 3 to 4 sections from each subject were analyzed and the values of calcium concentration were derived in microg/microl. Similar values of calcium density were found in males and females (535.6+77.1 and 539.2+74.1 microg/microl, respectively). No significant correlation between calcium density and age was observed either in all cases (r=0.0925) or in males (r=-0.0687) and in females (r=0.2676) separately. The unchanged calcium density during aging obtained by combining PIXE and histomorphometric techniques demonstrates that the skeletal calcium reduction observed in old age and probably during osteoporosis, is mainly due to the decrease of bone volume.

6.
Biol Trace Elem Res ; 10(2): 123-7, 1986 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24254358

RESUMO

The determination of calcium content in human bone tissue is very useful in metabolic diseases of bone, such as renal osteodystrophy, osteoporosis, hyperparathyroidism, and osteomalacia of diverse etiology. The PIXE technique allows calcium to be directly determined in bioptic tissue sections properly, sampled for histological optical and/or electron microscopy examination.Bone semithin sections (3 µm thick, 4×4 mm(2) dimensions), cut by ultramicrotome and deposited onto polyvinyl acetate films, underwent PIXE analysis using the CISE set-up. Histomorphometric (after standard staining), evaluation of calcified bone volume (CBV) in absolute value allows calcium density to be determined. A total of nine bone biopsies were analyzed (three sections each) obtaining values ranging between 352 and 482, with an average value of 421.5±15.3 (M±SE) µg/µL, in good agreement with literature data (obtained by AAS technique on dissected bone samples).The aim of this paper is to emphasize the usefulness, of combined PIXE and histomorphometric techniques for the study of calcium content in bone tissue in both healthy and diseased bones.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...