Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Vascular ; 30(6): 1069-1079, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34971330

RESUMO

INTRODUCTION: To compare endoleak outcomes after thoracic endovascular aneurysm repair (TEVAR) with different stent-graft generations into long-term follow-up. DESIGN: retrospective, observational, and single-center cohort study. METHODS: TEVAR procedures performed between November 1995 and December 2020 were analyzed. The primary endpoint of this study was the freedom from endoleak (type I/III) in four stent-graft generations during the follow-up period. The first generation (GEN1) included: Vanguard; AneuRx and Talent; Stentor; Excluder; Endologix; EndoFit. The second generation (GEN2) included: TAG and TX. The third (GEN3) included: Relay Plus; Valiant Captivia; Zenith Alpha and custom-made. The fourth (GEN4) included: Relay Pro; Conformable C-TAG; Navion; E-Vita; Najuta; Nexus; standard and custom-made thoraco-abdominal devices. Nonaortic and aorta-related survival was considered as secondary outcome. RESULTS: A total of 509 TEVAR were included with a 44.3 ± 42.5 months mean follow-up. Freedom from endoleak at 5 years was 65.6%, 61.4%, 76.2%, and 69.1% for GEN1, GEN2, GEN3, and GEN4, respectively (p = 0.368). The first two generations demonstrated a higher endoleak rate when compared with the two most recent ones (27.2 vs 18.2%, respectively; p = 0.043). GEN1 was an independent risk factor (p = 0.014) and GEN4 was an independent protective factor (p = 0.001) for endoleak. GEN1 was found to be a risk factor for type-Ia endoleak (p = 0.059). GEN4 demonstrated a protective association regarding type-Ib endoleak (p = 0.012). Overall survival was 75.3%, 44.4%, 27.2%, and 17.6% at 1, 5, 10, and 15 years, respectively. Survival distinguished as non-related versus aortic-related was 86.7% vs 23.5%, 52.7% vs 9.8%, 32.9% vs 2.0%, 21.2% vs 0% at 1, 5, 10, and 15 years, respectively (p< 0.000). CONCLUSION: Endoleak occurred in a non-negligible percentage of TEVAR patients. A significant reduction of endoleak incidence over evolving stent-grafts generations was registered. Newer stent-graft generations demonstrated better long-term endoleak. Data about long-term outcomes require ongoing updates to prove both the reliability and the durability of newer stent-graft generations.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações , Prótese Vascular/efeitos adversos , Estudos de Coortes , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Desenho de Prótese , Reprodutibilidade dos Testes , Estudos Retrospectivos , Stents/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...