Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 415
Filtrar
1.
Heart Rhythm ; 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38878939

RESUMO

BACKGROUND: Advances in leadless pacemaker technology have enabled accelerometer-based atrioventricular (AV) synchronous pacing by sensing atrial mechanical contraction. OBJECTIVES: To report performance of the Micra AV leadless pacemaker from the worldwide Micra AV post-approval registry (PAR) through 12-months. METHODS: The Micra AV PAR is a prospective single-arm observational registry designed to assess safety and effectiveness of Micra AV in a real-world setting. For the present interim analysis, major complications and system revisions through 12-months were summarized and compared to a historical cohort of 2,667 transvenous dual-chamber pacing patients. RESULTS: The device was successfully implanted in 796 of 801 patients (99.4%) at 97 centers in 19 countries. Micra AV patients were older (74.1 vs. 71.1 years, P<0.0001) with a higher incidence of renal disease (22.3% vs. 9.8%, P<0.0001) compared to transvenous dual-chamber patients. Through 12-months, the major complication rate was 3.7% in Micra AV patients compared to 8.8% in transvenous dual-chamber patients (hazard ratio [HR]: 0.42, 95% confidence interval [CI]: 0.28-0.61; P<0.001). The system revision rate was 1.5% in Micra AV patients compared to 5.5% for transvenous dual-chamber patients (HR: 0.25, 95% CI: 0.13-0.47; P<0.001); this reduction was largely driven by the absence of lead dislodgements requiring revision. Median AV synchrony index was 79.4% (IQR:65.2%-86.4%) among patients paced >90%. CONCLUSIONS: The Micra AV leadless pacemaker was implanted with a high rate of success in patients with multiple co-morbidities, with a significantly lower rate of complications and system revisions through 12-months compared to a historical cohort of patients with transvenous dual-chamber pacemakers.

2.
Resuscitation ; : 110269, 2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38852828

RESUMO

INTRODUCTION: Early initiation of cardiopulmonary resuscitation (CPR) by bystanders of out-of-hospital cardiac arrest (OHCA) significantly improves survival and neurological outcomes. However, misconceptions about human immunodeficiency virus (HIV) transmission risk during CPR can deter lay bystanders from performing resuscitation. The aim of this study was to compare the rate of CPR initiation by lay bystanders who witnessed OHCA in subjects with and without HIV infection. METHODS: We analysed data from the two French cardiac arrest registries (SDEC and RéAC) from 2012 to 2020. We identified HIV-positive individuals from the French National Health Insurance database for the SDEC registry, and directly from the RéAC registry data. We used logistic regression models to assess the association between CPR initiation by lay bystanders and the victim's HIV status. RESULTS: Of 58,177 witnessed OHCA cases, 192 (0.3%) occurred in HIV-positive subjects. These individuals were younger, more often male, and presented more shockable initial rhythms compared with subjects without HIV. Overall, there was no difference in the CPR initiation rate according to the HIV status (57.3% vs 47.6%, adjusted odds ratio 1.11, 95% confidence interval 0.83-1.48). The CPR initiation rate also did not differ by location between victims with or without HIV (home: 57.7% vs 45.4%; public places: 56.0% vs 53.6%; p for interaction = 0.46). Survival and neurological outcomes at hospital discharge did not differ based on the HIV status. CONCLUSIONS: This study revealed that the rate of CPR initiation by lay bystanders did not differ between HIV and non-HIV subjects during OHCA.

4.
J Am Heart Assoc ; 13(11): e033723, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38780180

RESUMO

BACKGROUND: Studies reporting on the incidence of sudden cardiac arrest and/or death (SCA/D) in athletes commonly lack methodological and reporting rigor, which has implications for screening and preventative policy in sport. To date, there are no tools designed for assessing study quality in studies investigating the incidence of SCA/D in athletes. METHODS AND RESULTS: The International Criteria for Reporting Study Quality for Sudden Cardiac Arrest/Death tool (IQ-SCA/D) was developed following a Delphi process. Sixteen international experts in sports cardiology were identified and invited. Experts voted on each domain with subsequent moderated discussion for successive rounds until consensus was reached for a final tool. Interobserver agreement between a novice, intermediate, and expert observer was then assessed from the scoring of 22 relevant studies using weighted and unweighted κ analyses. The final IQ-SCA/D tool comprises 8 domains with a summated score of a possible 22. Studies are categorized as low, intermediate, and high quality with summated IQ-SCA/D scores of ≤11, 12 to 16, and ≥17, respectively. Interrater agreement was "substantial" between all 3 observers for summated IQ-SCA/D scores and study categorization. CONCLUSIONS: The IQ-SCA/D is an expert consensus tool for assessing the study quality of research reporting the incidence of SCA/D in athletes. This tool may be used to assist researchers, reviewers, journal editors, and readers in contextualizing the methodological quality of different studies with varying athlete SCA/D incidence estimates. Importantly, the IQ-SCA/D also provides an expert-informed framework to support and guide appropriate design and reporting practices in future SCA/D incidence trials.


Assuntos
Consenso , Morte Súbita Cardíaca , Técnica Delphi , Humanos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Incidência , Projetos de Pesquisa/normas , Atletas , Medicina Esportiva/normas , Medicina Esportiva/métodos , Variações Dependentes do Observador
5.
Clin Rev Allergy Immunol ; 66(2): 223-240, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38696031

RESUMO

Secondary prevention with penicillin aims to prevent further episodes of acute rheumatic fever and subsequent development of rheumatic heart disease (RHD). Penicillin allergy, self-reported by 10% of the population, can affect secondary prevention programs. We aimed to assess the role for (i) routine penicillin allergy testing and the (ii) safety of penicillin allergy delabeling approaches in this context. We searched MEDLINE, Embase, CENTRAL, ClinicalTrials.gov, WHO ICTRP, ISRCTN, and CPCI-S to identify the relevant reports. We found 2419 records, but no studies addressed our initial question. Following advice from the WHO-Guideline committee and experts, we identified 6 manuscripts on allergy testing focusing on other populations showing that the prevalence of allergy confirmed by testing was low and the incidence of life-threatening reactions to BPG was very low (< 1-3/1000 individuals treated). A subsequent search addressed penicillin allergy delabeling. This found 516 records, and 5 studies addressing the safety of direct oral drug challenge vs. skin testing followed by drug administration in patients with suspected penicillin allergy. Immediate allergic reactions of minor severity were observed for a minority of patients and occurred less frequently in the direct drug challenge group: 2.3% vs. 11.5%; RR = 0.25, 95%CI 0.15-0.45, P < 0.00001, I2 = 0%. No anaphylaxis or deaths were observed. Severe allergic reactions to penicillin are extremely rare and can be recognized and dealt by trained healthcare workers. Confirmation of penicillin allergy diagnosis or delabeling using direct oral drug challenge or penicillin skin testing seems to be safe and is associated with a low rate of adverse reactions.


Assuntos
Hipersensibilidade a Drogas , Penicilinas , Guias de Prática Clínica como Assunto , Testes Cutâneos , Organização Mundial da Saúde , Humanos , Hipersensibilidade a Drogas/diagnóstico , Hipersensibilidade a Drogas/epidemiologia , Penicilinas/efeitos adversos , Antibacterianos/efeitos adversos
6.
Heart Rhythm ; 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38810921

RESUMO

BACKGROUND: Electrocardiographic screening before subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation is unsuccessful in around 10% of cases. A personalized screening method, by slightly moving the electrodes, to obtain a better R/T ratio has been described to overcome traditional screening failure. OBJECTIVE: The objectives of the SIS study were to assess to what extent a personalized screening method improves eligibility for S-ICD implantation and to evaluate the inappropriate shock rate after such screening success. METHODS: All consecutive patients eligible for an S-ICD implantation were prospectively recruited across 20 French centers between December 2019 and January 2022. In case of traditional screening failure, patients received a second personalized screening. If at least 1 vector was positive, the personalized screening was considered successful, and the patient was eligible for implantation. RESULTS: The study included 474 patients (mean age, 50.4 ± 14.1 years; 77.4% men). Traditional screening was successful in 456 (96.2%) cases. This figure rose to 98.3% (n = 466; P = .002) when personalized screening was performed. All patients implanted after successful personalized screening had correct signal detection on initial device interrogation. Nevertheless, after 1-year follow-up, 3 of the 7 patients (43%) implanted with personalized screening experienced inappropriate shock vs 18 of the 427 patients (4.2%) with traditional screening and S-ICD implantation (P = .003). CONCLUSION: Traditional S-ICD screening was successful in our study in a high proportion of patients. Considering the small improvement in success of screening and a higher rate of inappropriate shock, a strategy of personalized screening cannot be routinely recommended. CLINICALTRIALS: gov identifier: NCT04101253.

7.
Ann Cardiol Angeiol (Paris) ; 73(3): 101764, 2024 Jun.
Artigo em Francês | MEDLINE | ID: mdl-38723317

RESUMO

Sports-related sudden death is an uncommon event, affecting mainly middle-aged men who practice leisure sports, and is related to unknown coronary artery disease. In athletes, cardiac causes are also predominant, with a greater proportion of structural and electrical heart disease. If first-aid resuscitation measures are initiated, survival easily exceeds 50%, and this is an excellent educational illustration of how to improve the prognosis of non-sport-related cardiac arrest. Prevention of a sport-related cardiovascular event remains difficult, and relies on clinical examination, questioning (including family history) and resting ECG in participants >35 years old. The non-contraindication visit is also an opportunity to pass on to the patient the rules of good sports "hygiene" and life-saving gestures in the event of sudden death during sport in one of the partners (and the importance of regularly educating oneself in life-saving gestures...).


Assuntos
Morte Súbita Cardíaca , Exercício Físico , Humanos , Morte Súbita Cardíaca/prevenção & controle , Esportes , Fatores de Risco de Doenças Cardíacas , Masculino , Doenças Cardiovasculares/prevenção & controle
8.
Clin Res Cardiol ; 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38806821

RESUMO

BACKGROUND: Immune checkpoint inhibitors (ICIs) can induce cardiovascular toxicities. OBJECTIVES: To prospectively assess the incidence of major cardiovascular events (MACE) on ICIs in solid cancer patients: myocarditis, pericarditis, acute coronary syndrome, heart failure, high-degree conduction abnormalities or sustained ventricular arrhythmias, or cardiovascular death at 6 weeks (early MACE), including asymptomatic clinical changes by an independent adjudication committee using current recommended diagnostic criteria. The secondary objective was the incidence of the above-mentioned events adding atrial fibrillation (AF) at 6 months (late MACE). RESULTS: Participants underwent pre-ICIs and repeated multimodality cardiac imaging (echocardiogram, cardiac magnetic resonance (CMR)), serum biomarkers (ultrasensitive troponin I), and rhythm surveillance (ambulatory ECG monitoring) at 6 weeks and 6 months. Forty-nine patients (38 (77.6%) male; mean age 64.3 (SD 11.0) years old) were included (June 2020-December 2021). Early MACE were observed in 9 (18.4%) patients at mean 40.1 (SD 5.9) days, with heart failure (HF) in 5 (10.2%), ventricular arrhythmias, or new conduction disorders in 4 (8.2%) patients. History of AF (HR 4.49 (CI 1.11-18.14), P = 0.035) predicted early MACE. At 6 months follow-up, 18 MACE were observed in 15/49 (31%) patients, with 6 (12.2%) HF events, 5 (10.2%) significant ventricular arrhythmias, or conduction disorders, and 4 (8.2%) AF. There was a significant decline in LVEF (P < 0.001) in patients with no MACE (P = 0.003) or HF (P = 0.0028). Higher creatinine at inclusion (HR 0.99 [0.98-1.00], P = 0.006) predicted HF on multivariate analysis. There were no significant T1 or T2 mapping changes in our study cohort on repeated CMR. CONCLUSIONS: Cardiotoxicity on ICIs is more frequent than previously described when using a thorough detection strategy, consisting mainly in HF and asymptomatic rhythm disorders.

9.
Lancet Glob Health ; 12(6): e983-e994, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38762298

RESUMO

BACKGROUND: Early detection and diagnosis of acute rheumatic fever and rheumatic heart disease are key to preventing progression, and echocardiography has an important diagnostic role. Standard echocardiography might not be feasible in high-prevalence regions due to its high cost, complexity, and time requirement. Handheld echocardiography might be an easy-to-use, low-cost alternative, but its performance in screening for and diagnosing acute rheumatic fever and rheumatic heart disease needs further investigation. METHODS: In this systematic review and meta-analysis, we searched Embase, MEDLINE, LILACS, and Conference Proceedings Citation Index-Science up to Feb 9, 2024, for studies on the screening and diagnosis of acute rheumatic fever and rheumatic heart disease using handheld echocardiography (index test) or standard echocardiography or auscultation (reference tests) in high-prevalence areas. We included all studies with useable data in which the diagnostic performance of the index test was assessed against a reference test. Data on test accuracy in diagnosing rheumatic heart disease, acute rheumatic fever, or carditis with acute rheumatic fever (primary outcomes) were extracted from published articles or calculated, with authors contacted as necessary. Quality of evidence was appraised using GRADE and QUADAS-2 criteria. We summarised diagnostic accuracy statistics (including sensitivity and specificity) and estimated 95% CIs using a bivariate random-effects model (or univariate random-effects models for analyses including three or fewer studies). Area under the curve (AUC) was calculated from summary receiver operating characteristic curves. Heterogeneity was assessed by visual inspection of plots. This study was registered with PROSPERO (CRD42022344081). FINDINGS: Out of 4868 records we identified 11 studies, and two additional reports, comprising 15 578 unique participants. Pooled data showed that handheld echocardiography had high sensitivity (0·87 [95% CI 0·76-0·93]), specificity (0·98 [0·71-1·00]), and overall high accuracy (AUC 0·94 [0·84-1·00]) for diagnosing rheumatic heart disease when compared with standard echocardiography (two studies; moderate certainty of evidence), with better performance for diagnosing definite compared with borderline rheumatic heart disease. High sensitivity (0·79 [0·73-0·84]), specificity (0·85 [0·80-0·89]), and overall accuracy (AUC 0·90 [0·85-0·94]) for screening rheumatic heart disease was observed when pooling data of handheld echocardiography versus standard echocardiography (seven studies; high certainty of evidence). Most studies had a low risk of bias overall. Some heterogeneity was observed for sensitivity and specificity across studies, possibly driven by differences in the prevalence and severity of rheumatic heart disease, and level of training or expertise of non-expert operators. INTERPRETATION: Handheld echocardiography has a high accuracy and diagnostic performance when compared with standard echocardiography for diagnosing and screening of rheumatic heart disease in high-prevalence areas. FUNDING: World Health Organization. TRANSLATIONS: For the Chinese, French, Italian, Persian, Portuguese, Spanish and Urdu translations of the abstract see Supplementary Materials section.


Assuntos
Ecocardiografia , Cardiopatia Reumática , Humanos , Cardiopatia Reumática/diagnóstico por imagem , Ecocardiografia/estatística & dados numéricos , Ecocardiografia/métodos , Programas de Rastreamento/métodos , Organização Mundial da Saúde , Guias de Prática Clínica como Assunto , Sensibilidade e Especificidade
10.
Resuscitation ; 199: 110202, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38582445

RESUMO

BACKGROUND: Controlled donation after circulatory death (cDCD) in post-anoxic brain injury is a valuable source of organs that is still underused in some countries. We assessed the number of potential cDCD donors after out-of-hospital cardiac arrest (OHCA) in Paris and its suburbs and extrapolated the results to the French population. METHODS: Using the large regional registry of the Great Paris area, we prospectively included all consecutive adults with OHCA with a stable return of spontaneous circulation (ROSC) who ultimately died in the intensive care unit (ICU) after withdrawal of life-sustaining treatments (WLST) due to post anoxic brain injury. The primary endpoint was potential for organ donation by cDCD in this population. The number of potential cDCD donors was calculated and extrapolated to the entire French population. RESULTS: Between 2011 and 2018, 4638 patients with stable ROSC were admitted to ICUs after OHCA, and 3170 died in ICU, of which 1034 died after WLST due to post-anoxic brain injury. When considering French criteria, 421/1034 patients (41%) would have been potential cDCD donors (55 patients per year in a 4.67 million population). After standardization for age and sex, the potential for cDCD was 515 (95% CI 471-560) patients per year in France corresponding to an annual incidence of 1.18 per 100 000 inhabitants per year. CONCLUSIONS: Organ donation by cDCD after cardiac arrest could provide a large pool of donors in France.


Assuntos
Parada Cardíaca Extra-Hospitalar , Sistema de Registros , Obtenção de Tecidos e Órgãos , Humanos , Masculino , Feminino , Parada Cardíaca Extra-Hospitalar/mortalidade , Parada Cardíaca Extra-Hospitalar/terapia , Pessoa de Meia-Idade , Obtenção de Tecidos e Órgãos/estatística & dados numéricos , Obtenção de Tecidos e Órgãos/métodos , Idoso , Estudos Prospectivos , Doadores de Tecidos/estatística & dados numéricos , França/epidemiologia , Paris/epidemiologia , Unidades de Terapia Intensiva/estatística & dados numéricos , Adulto , Hipóxia Encefálica/etiologia
12.
Glob Heart ; 19(1): 39, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38681969

RESUMO

Background: Rheumatic Heart Disease (RHD) is the most common cause of valvular heart disease worldwide. Undiagnosed or untreated RHD can complicate pregnancy and lead to poor maternal and fetal outcomes and is a significant factor in non-obstetric morbidity. Echocardiography has an emerging role in screening for RHD. We aimed to critically analyse the evidence on the use of echocardiography for screening pregnant women for RHD in high-prevalence areas. Methods: We searched MEDLINE and Embase to identify the relevant reports. Two independent reviewers assessed the reports against the eligibility criteria in a double-blind process. Results: The searches (date: 4 April 2023) identified 432 records for screening. Ten non-controlled observational studies were identified, five using portable or handheld echocardiography, comprising data from 23,166 women. Prevalence of RHD varied across the studies, ranging from 0.4 to 6.6% (I2, heterogeneity >90%). Other cardiac abnormalities (e.g., congenital heart disease and left ventricular systolic dysfunction) were also detected <1% to 2% of cases. Certainty of evidence was very low. Conclusion: Echocardiography as part of antenatal care in high-prevalence areas may detect RHD or other cardiac abnormalities in asymptomatic pregnant women, potentially reducing the rates of disease progression and adverse labor-associated outcomes. However, this evidence is affected by the low certainty of evidence, and lack of studies comparing echocardiography versus standard antenatal care. Prospective Registration: PROSPERO 2022 July 4; CRD42022344081 Available from: https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=344081. Research question: 'In areas with a high prevalence of rheumatic heart disease, should handheld echocardiography be added to routine antenatal care?'


Assuntos
Ecocardiografia , Complicações Cardiovasculares na Gravidez , Cardiopatia Reumática , Humanos , Cardiopatia Reumática/epidemiologia , Cardiopatia Reumática/diagnóstico por imagem , Feminino , Gravidez , Ecocardiografia/métodos , Prevalência , Complicações Cardiovasculares na Gravidez/epidemiologia , Complicações Cardiovasculares na Gravidez/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Cuidado Pré-Natal/métodos
13.
Cardiovasc Revasc Med ; 64: 7-14, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38448258

RESUMO

BACKGROUND: Left atrial appendage (LAA) occluder embolization is an infrequent but serious complication. OBJECTIVES: We aim to describe timing, management and clinical outcomes of device embolization in a multi-center registry. METHODS: Patient characteristics, imaging findings and procedure and follow-up data were collected retrospectively. Device embolizations were categorized according to 1) timing 2) management and 3) clinical outcomes. RESULTS: Sixty-seven centers contributed data. Device embolization occurred in 108 patients. In 70.4 % of cases, it happened within the first 24 h of the procedure. The device was purposefully left in the LA and the aorta in two (1.9 %) patients, an initial percutaneous retrieval was attempted in 81 (75.0 %) and surgery without prior percutaneous retrieval attempt was performed in 23 (21.3 %) patients. Two patients died before a retrieval attempt could be made. In 28/81 (34.6 %) patients with an initial percutaneous retrieval attempt a second, additional attempt was performed, which was associated with a high mortality (death in patients with one attempt: 2.9 % vs. second attempt: 21.4 %, p < 0.001). The primary outcome (bailout surgery, cardiogenic shock, stroke, TIA, and/or death) occurred in 47 (43.5 %) patients. Other major complications related to device embolization occurred in 21 (19.4 %) patients. CONCLUSIONS: The majority of device embolizations after LAA closure occurs early. A percutaneous approach is often the preferred method for a first rescue attempt. Major adverse event rates, including death, are high particularly if the first retrieval attempt was unsuccessful. CONDENSED ABSTRACT: This dedicated multicenter registry examined timing, management, and clinical outcome of device embolization. Early embolization (70.4 %) was most frequent. As a first rescue attempt, percutaneous retrieval was preferred in 75.0 %, followed by surgical removal (21.3 %). In patients with a second retrieval attempt a higher mortality (death first attempt: 2.9 % vs. death second attempt: 24.1 %, p < 0.001) was observed. Mortality (10.2 %) and the major complication rate after device embolization were high.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cateterismo Cardíaco , Remoção de Dispositivo , Sistema de Registros , Humanos , Masculino , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Feminino , Idoso , Estudos Retrospectivos , Resultado do Tratamento , Fatores de Tempo , Idoso de 80 Anos ou mais , Fatores de Risco , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Fibrilação Atrial/terapia , Fibrilação Atrial/mortalidade , Remoção de Dispositivo/efeitos adversos , Embolia/etiologia , Embolia/mortalidade , Pessoa de Meia-Idade , Dispositivo para Oclusão Septal , Oclusão do Apêndice Atrial Esquerdo
16.
Arch Cardiovasc Dis ; 117(3): 224-231, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38302391

RESUMO

Sustainability in healthcare, particularly within the domain of cardiac electrophysiology, assumes paramount importance for the near future. The escalating environmental constraints encountered necessitate a proactive approach. This position paper aims to raise awareness among physicians, spark critical inquiry and identify potential solutions to enhance the sustainability of our practice. Reprocessing of single-use medical devices has emerged as a potential solution to mitigate the environmental impact of electrophysiology procedures, while also offering economic advantages. However, reprocessing remains unauthorized in certain countries. In regions where it is possible, stringent regulatory standards must be adhered to, to ensure patient safety. It is essential that healthcare professionals, policymakers and manufacturers collaborate to drive innovation, explore sustainable practices and ensure that patient care remains uncompromised in the face of environmental challenges. Ambitious national/international programmes of disease prevention should be the cornerstone of the strategy. It is equally vital to implement immediate actions, as delineated in this position paper, to bring about tangible change quickly.


Assuntos
Cardiologia , Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Arritmias Cardíacas/terapia , Sociedades Médicas
17.
Heart Rhythm ; 21(6): 836-844, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38336193

RESUMO

BACKGROUND: The PRAETORIAN score estimates the risk of failure of subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy by using generator and lead positioning on bidirectional chest radiographs. The PRospective randomized compArative trial of subcutanEous implanTable cardiOverter-defibrillatoR ImplANtation with and without DeFibrillation Testing (PRAETORIAN-DFT) investigates whether PRAETORIAN score calculation is noninferior to defibrillation testing (DFT) with regard to first shock efficacy in spontaneous events. OBJECTIVE: This prespecified subanalysis assessed the predictive value of the PRAETORIAN score for defibrillation success in induced ventricular arrhythmias. METHODS: This multicenter investigator-initiated trial randomized 965 patients between DFT and PRAETORIAN score calculation after de novo S-ICD implantation. Successful DFT was defined as conversion of induced ventricular arrhythmia in <5 seconds from shock delivery within 2 attempts. Bidirectional chest radiographs were obtained after implantation. The predictive value of the PRAETORIAN score for DFT success was calculated for patients in the DFT arm. RESULTS: In total, 482 patients were randomized to undergo DFT. Of these patients, 457 (95%) underwent DFT according to protocol, of whom 445 (97%) had successful DFT and 12 (3%) had failed DFT. A PRAETORIAN score of ≥90 had a positive predictive value of 25% for failed DFT, and a PRAETORIAN score of <90 had a negative predictive value of 99% for successful DFT. A PRAETORIAN score of ≥90 was the strongest independent predictor for failed DFT (odds ratio 33.77; confidence interval 6.13-279.95; P < .001). CONCLUSION: A PRAETORIAN score of <90 serves as a reliable indicator for DFT success in patients with S-ICD, and a PRAETORIAN score of ≥90 is a strong predictor for DFT failure.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica , Valor Preditivo dos Testes , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Cardioversão Elétrica/métodos , Estudos Prospectivos , Idoso , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Medição de Risco/métodos , Taquicardia Ventricular/terapia , Taquicardia Ventricular/fisiopatologia , Fibrilação Ventricular/terapia
18.
Eur Heart J Cardiovasc Pharmacother ; 10(3): 184-189, 2024 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-38216511

RESUMO

INTRODUCTION: Atrial arrhythmia is the most common complication of patent foramen ovale (PFO) closure. The real incidence of post-PFO closure atrial arrhytmia and whether this complication can be prevented is unknown. METHODS/DESIGN: The Assessment of Flecainide to Lower the PFO closure risk of Atrial fibrillation or Tachycardia (AFLOAT) trial is a prospective, national, multicentre, randomized, open-label, superiority trial with a blind evaluation of all the endpoints (PROBE design). A total of 186 patients are randomized in a 1:1:1 ratio immediately after PFO closure to receive Flecainide (150 mg per day in a single sustained-release (SR) dose) for 6 months (Group 1), Flecainide (150 mg per day in a single SR dose) for 3 months (Group 2), or no additional treatment (standard of care) for 6 months (Group 3). The primary endpoint is the percentage of patients with at least one episode of symptomatic or asymptomatic atrial arrhythmia episode (≥30 s) recorded within 3 months after PFO closure on long-term monitoring with an insertable cardiac monitor. Whether 3 months of treatment is sufficient compared to 6 months will be analysed as a secondary objective of the study. CONCLUSION: AFLOAT is the first trial to test the hypothesis that a short treatment with oral Flecainide can prevent the new-onset of atrial arrhythmia after PFO closure. CLINICAL TRIAL REGISTRATION: NCT05213104 (clinicaltrials.gov).


Assuntos
Antiarrítmicos , Fibrilação Atrial , Flecainida , Forame Oval Patente , Humanos , Flecainida/efeitos adversos , Flecainida/administração & dosagem , Flecainida/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/prevenção & controle , Estudos Prospectivos , Antiarrítmicos/uso terapêutico , Antiarrítmicos/efeitos adversos , Antiarrítmicos/administração & dosagem , Resultado do Tratamento , Forame Oval Patente/complicações , Forame Oval Patente/terapia , Feminino , Masculino , Fatores de Tempo , Adulto , Pessoa de Meia-Idade , Frequência Cardíaca/efeitos dos fármacos
19.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38291925

RESUMO

A significant proportion of patients who suffer from atrial fibrillation (AF) and are in need of thromboembolic protection are not treated with oral anticoagulation or discontinue this treatment shortly after its initiation. This undertreatment has not improved sufficiently despite the availability of direct oral anticoagulants which are associated with less major bleeding than vitamin K antagonists. Multiple reasons account for this, including bleeding events or ischaemic strokes whilst on anticoagulation, a serious risk of bleeding events, poor treatment compliance despite best educational attempts, or aversion to drug therapy. An alternative interventional therapy, which is not associated with long-term bleeding and is as effective as vitamin K anticoagulation, was introduced over 20 years ago. Because of significant improvements in procedural safety over the years, left atrial appendage closure, predominantly achieved using a catheter-based, device implantation approach, is increasingly favoured for the prevention of thromboembolic events in patients who cannot achieve effective anticoagulation. This management strategy is well known to the interventional cardiologist/electrophysiologist but is not more widely appreciated within cardiology or internal medicine. This article introduces the devices and briefly explains the implantation technique. The indications and device follow-up are more comprehensively described. Almost all physicians who care for adult patients will have many with AF. This practical guide, written within guideline/guidance boundaries, is aimed at those non-implanting physicians who may need to refer patients for consideration of this new therapy, which is becoming increasingly popular.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Médicos , Acidente Vascular Cerebral , Tromboembolia , Adulto , Humanos , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/complicações , Oclusão do Apêndice Atrial Esquerdo , Consenso , Hemorragia/induzido quimicamente , Hemorragia/prevenção & controle , Anticoagulantes/efeitos adversos , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Vitamina K , Apêndice Atrial/cirurgia , Resultado do Tratamento
20.
ESC Heart Fail ; 11(2): 1228-1235, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38234123

RESUMO

AIMS: Heart failure (HF) is a chronic disease affecting 64 million people worldwide and places a severe burden on society because of its mortality, numerous re-hospitalizations and associated costs. HeartLogic™ is an algorithm programmed into implanted devices incorporating several biometric parameters which aims to predict HF episodes. It provides an index which can be monitored remotely, allowing pre-emptive treatment of congestion to prevent acute decompensation. We aim to assess the impact and security of pre-emptive HF management, guided by the HeartLogic™ index. METHODS AND RESULTS: The HeartLogic™ France Cohort Study is an investigator-initiated, prospective, multi-centre, non-randomized study. Three hundred ten patients with a history of HF (left ventricular ejection fraction ≤40%; or at least one episode of clinical HF with elevated NT-proBNP ≥450 ng/L) and implanted with a cardioverter defibrillator enabling HeartLogic™ index calculation will be included across 10 French centres. The HeartLogic™ index will be monitored remotely for 12 months and in the event of a HeartLogic™ index ≥16, the local investigator will contact the patient for assessment and adjust HF treatment as necessary. The primary endpoint is unscheduled hospitalization for HF. Secondary endpoints are all-cause mortality, cardiovascular death, HF-related death, unscheduled hospitalizations for ventricular or atrial arrhythmia and HeartLogic™ index evolution over time. Blood samples will be collected for biobanking, and quality of life will be assessed. Finally, the safety of a HeartLogic™-triggered strategy for initiating or increasing diuretic therapy will be assessed. A blind and independent committee will adjudicate the events. CONCLUSIONS: The HeartLogic™ France Cohort Study will provide robust real-world data in a cohort of HF patients managed with the HeartLogic™ algorithm allowing pre-emptive treatment of heart failure exacerbations.


Assuntos
Insuficiência Cardíaca , Qualidade de Vida , Humanos , Estudos de Coortes , Volume Sistólico , Estudos Prospectivos , Bancos de Espécimes Biológicos , Função Ventricular Esquerda , Algoritmos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...