Ultrasound Obstet Gynecol ; 59(2): 220-225, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33998077

RESUMO

OBJECTIVE: To evaluate corpus callosum (CC) size by neurosonography (NSG) in fetuses with an isolated major congenital heart defect (CHD) and explore the association of CC size with the expected pattern of in-utero oxygen supply to the brain. METHODS: A total of 56 fetuses with postnatally confirmed isolated major CHD and 56 gestational-age-matched controls were included. Fetuses with CHD were stratified into two categories according to the main expected pattern of cerebral arterial oxygen supply: Class A, moderately to severely reduced oxygen supply (left outflow tract obstruction and transposition of the great arteries) and Class B, near normal or mildly impaired oxygenated blood supply to the brain (other CHD). Transvaginal NSG was performed at 32-36 weeks in all fetuses to evaluate CC length, CC total area and areas of CC subdivisions in the midsagittal plane. RESULTS: CHD fetuses had a significantly smaller CC area as compared to controls (7.91 ± 1.30 vs 9.01 ± 1.44 mm2 ; P < 0.001), which was more pronounced in the most posterior part of the CC. There was a significant linear trend for reduced CC total area across the three clinical groups, with CHD Class-A cases showing more prominent changes (controls, 9.01 ± 1.44 vs CHD Class B, 8.18 ± 1.21 vs CHD Class A, 7.53 ± 1.33 mm2 ; P < 0.05). CONCLUSIONS: Fetuses with major CHD had a smaller CC compared with controls, and the difference was more marked in the CHD subgroup with expected poorer brain oxygenation. Sonographic CC size could be a clinically feasible marker of abnormal white matter development in CHD. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Encéfalo/irrigação sanguínea , Corpo Caloso/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Estudos de Casos e Controles , Circulação Cerebrovascular/fisiologia , Corpo Caloso/embriologia , Feminino , Desenvolvimento Fetal/fisiologia , Feto/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Humanos , Consumo de Oxigênio/fisiologia , Gravidez
2.
Phys Med Biol ; 66(4): 045001, 2021 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-33296884

RESUMO

X-ray mammography is the gold standard technique in breast cancer screening programmes. One of the main challenges that mammography is still facing is scattered radiation, which degrades the quality of the image and complicates the diagnosis process. Anti-scatter grids, the main standard physical scattering reduction technique, have some unresolved challenges as they increase the dose delivered to the patient, do not remove all the scattered radiation and increase the cost of the equipment. Alternative scattering reduction methods based on post-processing algorithms, have lately been under investigation. This study is concerned with the use of image post-processing to reduce the scatter contribution in the image, by convolving the primary plus scatter image with kernels obtained from simplified Monte Carlo (MC) simulations. The proposed semi-empirical approach uses up to five thickness-dependant symmetric kernels to accurately estimate the scatter contribution of different areas of the image. Single breast thickness-dependant kernels can over-estimate the scatter signal up to 60%, while kernels adapting to local variations have to be modified for each specific case adding high computational costs. The proposed method reduces the uncertainty to a 4%-10% range for a 35-70 mm breast thickness range, making it a very efficient, case-independent scatter modelling technique. To test the robustness of the method, the scattered corrected image has been successfully compared against full MC simulations for a range of breast thicknesses. In addition, clinical images of the 010A CIRS phantom were acquired with a mammography system with and without the presence of the anti-scatter grid. The grid-less images were post-processed and their quality was compared against the grid images, by evaluating the contrast-to-noise ratio and variance ratio using several test objects, which simulate calcifications and tumour masses. The results obtained show that the method reduces the scatter to similar levels than the anti-scatter grids.


Assuntos
Mamografia/métodos , Modelos Teóricos , Espalhamento de Radiação , Algoritmos , Mama/citologia , Mama/diagnóstico por imagem , Feminino , Humanos , Método de Monte Carlo , Imagens de Fantasmas
3.
Ultrasound Obstet Gynecol ; 51(3): 349-356, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28295792

RESUMO

OBJECTIVES: To define the pattern of fetal echocardiographic changes associated with isolated pulmonary valve stenosis (PS) and to correlate the echocardiographic findings with neonatal outcome and the need for postnatal pulmonary valvuloplasty within the first 12 months postpartum. METHODS: This was a prospective cohort study between January 2009 and October 2015 of 16 fetuses with isolated PS and 48 controls matched by gestational age at ultrasound examination (± 2 weeks) evaluated at the Fetal Cardiology Unit at BCNatal (Barcelona). Standard fetal ultrasound and comprehensive echocardiography, which included cardiovascular morphometric parameters, and systolic and diastolic functional and timing measurements, were performed in all cases. Baseline characteristics and perinatal outcome were retrieved from clinical records. Cases were followed up until 12 months of age, and admission to intensive care unit, days of hospitalization, need for prostaglandins and requirement for postnatal surgery were reviewed. Fetal PS cases were analyzed according to the need for postnatal pulmonary valvuloplasty. RESULTS: The study groups were similar in terms of baseline, fetal ultrasound and perinatal characteristics. Median gestational age at diagnosis of PS was 33.4 (range, 20.0-36.5) weeks. Most cases corresponded to mild or moderate PS; only three fetuses had reversed flow in the ductus arteriosus before delivery. Six (37.5%) newborns, including all three with reversed flow in the ductus arteriosus prenatally, required postnatal pulmonary valvuloplasty. Fetuses with PS presented with larger and more globular hearts, with increased myocardial wall thickness in the third trimester. Despite preserved right ventricular (RV) ejection fraction and systolic longitudinal motion, PS cases showed increased right cardiac output and signs of diastolic dysfunction, with higher ductus venosus pulsatility index (0.72 ± 0.32 vs 0.53 ± 0.16, P = 0.004) and tricuspid E/E' ratio (7.52 ± 3.07 vs 5.76 ± 1.79, P = 0.022). In addition, fetuses with PS displayed a compensatory increase in left ventricular (LV) radial and longitudinal motion, as shown by a higher ejection fraction (79.3 ± 8.23% vs 67.6 ± 11.3%, P = 0.003) and mitral annular-plane systolic excursion (5.94 ± 1.38 vs 5.0 ± 1.22 mm, P = 0.035). Finally, fetuses requiring postnatal pulmonary valvuloplasty showed a different pattern of echocardiographic findings from those not requiring valvuloplasty, with a significantly smaller RV and pulmonary valve diameter, reduced tricuspid annular-plane systolic excursion (5.08 ± 1.59 vs 8.07 ± 1.93 mm, P = 0.028), increased LV cardiac output (340 ± 16 vs 176 ± 44 mL/min/kg, P = 0.003) and more pronounced signs of LV diastolic dysfunction (mitral E' velocity, 5.78 ± 0.90 vs 8.16 ± 1.58 cm/s, P = 0.008). CONCLUSIONS: Fetuses with PS present with more hypertrophic, larger and more globular hearts in the third trimester of pregnancy, associated with a higher right cardiac output and impaired biventricular relaxation. In addition, signs of increased LV contraction were observed. Our data suggest that RV and LV functional parameters could be useful for predicting the need for postnatal pulmonary valvuloplasty. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Ecocardiografia , Ventrículos do Coração/fisiopatologia , Estenose da Valva Pulmonar/fisiopatologia , Ultrassonografia Pré-Natal , Adulto , Valvuloplastia com Balão , Feminino , Idade Gestacional , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/embriologia , Humanos , Recém-Nascido , Valor Preditivo dos Testes , Gravidez , Estudos Prospectivos , Estenose da Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/embriologia , Resultado do Tratamento , Remodelação Vascular , Remodelação Ventricular
4.
Cienc. tecnol. pharm ; 13(2): 62-66, abr. 2003. tab, graf
Artigo em Es | IBECS | ID: ibc-26126

RESUMO

Se ha puesto a punto y validado un nuevo método para la determinación de un antiinflamatorio no esteroideo, ibuprofeno, asociado a nanoesferas de poli-E-caprolactona, por espectroscopia de fluorescencia. Los valores de exactitud, precisión y linealidad demostraron la validez del mismo, siendo la sensibilidad, 7,89 10-6 mg/ml, idónea para este tipo de análisis. Los resultados obtenidos pusieron de relieve que el método analítico desarrollado es adecuado para la determinación de ibuprofeno asociado a sistema matriciales de poli-E-caprolactona (AU)


Assuntos
Humanos , Ibuprofeno/química , Ibuprofeno/farmacologia , Sensibilidade e Especificidade , Espectrometria de Fluorescência/métodos
SELEÇÃO DE REFERÊNCIAS