Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Am Heart J ; 261: 127-136, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37225386

RESUMO

BACKGROUND: A robotic Radiaction Shielding System (RSS) was developed to provide a full-body protection to all medical personnel during fluoroscopy-guided procedures, by encapsulating the imaging beam and blocking scattered radiation. OBJECTIVES: We aimed to evaluate its efficacy in real-world electrophysiologic (EP) laboratory- both during ablations and cardiovascular implantable electronic devices (CIED) procedures. METHODS: A prospective controlled study comparing consecutive real-life EP procedures with and without RSS using highly sensitive sensors in different locations. RESULTS: Thirty-five ablations and 19 CIED procedures were done without RSS installed and 31 ablations and 24 CIED procedures (17 with usage levels ≥70%) were done with RSS. Overall, there was 95% average usage level for ablations and 88% for CIEDs. For all procedures with ≥70% usage level and for all sensors, the radiation with RSS was significantly lower than radiation without RSS. For ablations, there was 87% reduction in radiation with RSS (76%-97% for different sensors). For CIEDs, there was 83% reduction in radiation with RSS (59%-92%). RSS usage did not increase procedure time and radiation time. User feedback showed a high-level of integration in the clinical workflow and safety profile for all types of EP procedures. CONCLUSIONS: For both CIED and ablation procedures the radiation with RSS was significantly lower than without RSS. Higher usage level brings higher reduction rates. Thus, RSS may have an important role in full-body protection to all medical personnel from scattered radiation during EP and CIED procedures. Until more data is available, it is recommended to maintain existing standard shielding.


Assuntos
Técnicas de Ablação , Procedimentos Cirúrgicos Robóticos , Humanos , Estudos Prospectivos , Eletrônica
2.
Isr Med Assoc J ; 24(1): 25-32, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35077042

RESUMO

BACKGROUND: Endocardial leads of permanent pacemakers (PPM) and implantable defibrillators (ICD) across the tricuspid valve (TV) can lead to tricuspid regurgitation (TR) or can worsen existing TR with subsequent severe morbidity and mortality. OBJECTIVES: To evaluate prospectively the efficacy of intraprocedural 2-dimentional-transthoracic echocardiography (2DTTE) in reducing/preventing lead-associated TR. METHODS: We conducted a prospective randomized controlled study comparing echocardiographic results in patients undergoing de-novo PPM/ICD implantation with intraprocedural echo-guided right ventricular (RV) lead placement (Group 1, n=56) versus non-echo guided implantation (Group 2, n=55). Lead position was changed if TR grade was more than baseline in Group 1. Cohort patients underwent 2DTTE at baseline and 3 and/or 6 months after implantation. Excluded were patients with baseline TR > moderate or baseline ≥ moderate RV dysfunction. RESULTS: The study comprised 111 patients (74.14 ± 11 years of age, 58.6% male, 19% ICD, 42% active leads). In 98 patients there was at least one follow-up echo. Two patients from Group 1 (3.6%) needed intraprocedural RV electrode repositioning. Four patients (3.5%, 2 from each group, all dual chamber PPM, 3 atrial fibrillation, 2 RV pacing > 40%, none with intraprocedural reposition) had TR deterioration during 6 months follow-up. One patient from Group 2 with baseline mild-moderate aortic regurgitation (AR) had worsening TR and AR within 3 months and underwent aortic valve replacement and TV repair. CONCLUSIONS: The rate of mechanically induced lead-associated TR is low; thus, a routine intraprocedural 2DTTE does not have a significant role in reducing/preventing it.


Assuntos
Ecocardiografia/métodos , Complicações Pós-Operatórias , Ajuste de Prótese , Implantação de Prótese , Cirurgia Assistida por Computador/métodos , Insuficiência da Valva Tricúspide , Valva Tricúspide/diagnóstico por imagem , Idoso , Estimulação Cardíaca Artificial/métodos , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Feminino , Humanos , Masculino , Avaliação de Processos e Resultados em Cuidados de Saúde , Marca-Passo Artificial , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Ajuste de Prótese/efeitos adversos , Ajuste de Prótese/métodos , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Implantação de Prótese/métodos , Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/prevenção & controle
3.
Harefuah ; 161(12): 743-746, 2022 Dec.
Artigo em Hebraico | MEDLINE | ID: mdl-36916112

RESUMO

INTRODUCTION: Pulmonary embolism, a common and potentially fatal clinical condition, occurs when a blood thrombus becomes lodged in the pulmonary vasculature and creates an acute increment in the pulmonary vascular resistance, which, in turn, creates a right ventricular strain. Among the more familiar electrocardiographic manifestations in acute pulmonary embolism is sinus tachycardia, right bundle branch block and ST-T abnormalities in the right precordium leads. Complete heart block or any type of bradycardia is uncommon. In our case report we present an 81 years old woman who was admitted to our institution with acute pulmonary embolism and complete atrioventricular block, which later resolved with appropriate anticoagulation therapy.


Assuntos
Bloqueio Atrioventricular , Embolia Pulmonar , Feminino , Humanos , Idoso de 80 Anos ou mais , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/etiologia , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/complicações , Eletrocardiografia , Doença Aguda
4.
J Atr Fibrillation ; 13(5): 2459, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34950336

RESUMO

BACKGROUND: Recent trials found poor temporal relationship between atrial fibrillation (AF) episodes and strokes. Thus, stroke in AF patients probably involves more mechanisms than cardiac embolism. We compared factors of inflammation, thrombosis and platelet reactivity between left (LA) and right atria (RA) and femoral vein (FV) in patients with AF. METHODS: Blood samples were collected from patients undergoing AF-ablation from the FV, RA and LA for neutrophil to lymphocyte ratio (NLR), immature platelet fraction (IPF) and count (IPC), CD40 ligand, P-selectin and E-Selectin. IPF was measured by an autoanalyzer; CD40 ligand, P-selectin, and E-Selectin were measured by ELISA and NLR was calculated from complete blood counts. RESULTS: Sixty-seven patients were included (age 65±10y, 63% male, CHA2DS2-VASc score 2.8±1.8, LA volume index 40±24 mL/m2, 63% paroxysmal AF). There was no difference between FV, RA and LA regarding NLR and CD40 ligand. Factors associated with platelets activity: P-selectin, IPC and IPF% were higher in RA vs LA (60.3 IQR 49.0-76.4 ng/ml vs. 59.3 IQR 49.0-74.7, respectively, p=0.03 for P-selectin, 7.5 IQR 5.2-10 103/µL vs. 7.1 IQR 5-9.8, p<0.01 for IPC, and 3.6 IQR 2.7-5.0 % vs. 3.6 IQR 2.6-4.8, p<0.01 for IPF%). Similar trends were for E-selectin (41.2 IQR 31.1-51.2 ng/mL vs. 38.7 IQR 27.9-50.4 p=0.09). Similar significant differences were found in patients with CHA2DS2-VASC≥2 but not in patients with low score. CONCLUSIONS: Patients with AF, especially those with CHA2DS2-VASc≥2, have higher markers of thrombogenicity in RA compared to LA. There was no difference in inflammatory properties between the atria.

5.
J Cardiovasc Electrophysiol ; 32(2): 305-315, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33331056

RESUMO

BACKGROUND: Strain imaging during left atrial (LA) reservoir phase (LASr) is used as a surrogate for LA structural remodeling and fibrosis. Atrial fibrillation (AF) patients with >5% low-voltage zones (LVZs) obtained by 3D-electro-anatomical-mapping have higher recurrence rate post-ablation. We investigated the relationship between LA remodeling using two-dimensional-speckle-tracking echocardiography (2D-STE) and high-density voltage mapping in AF patients. METHODS: A prospective study of 42 consecutive patients undergoing AF ablation. 2D-echo, 2D-STE, and high-density contact LA bipolar voltage maps were constructed before ablation. LVZs were determined with different bipolar amplitudes and their ratio per patient's LA area were investigated for correlation with LASr. We compared 2D-LASr results in patients with LVZs ≥ 5% (LVZs group) versus those with LVZ < 5% (non-LVZs group). RESULTS: Compared with non-LVZs group (n = 15), LVZs group (n = 27) included significantly older patients, more women, more persistent AF, higher CHA2 DS2 -VASc score, higher E/A ratio and higher LA volume index (p < .05). LVZs group had lower %LASr values (12.4 ± 5.9% vs. 21.1 ± 6.3, respectively; p<.001). LVZs% in different amplitudes (<0.1 mV, <0.2 mV, and <0.5 mV) were negatively correlated with %LASr (r = -.63, r = -.68, and r = -.72, respectively; p< .001). Atrial strain thresholds for LVZs ≥ 5% in amplitudes <0.1 mV, <0.2 mV, and <0.5 mV were associated with %LASr 12.98, 16.16 and 19.55, respectively; p< .05). In a multivariate analysis, %LASr was the only independent indicator of LVZs (OR, 0.8; 95% CI, 0.6-0.9; p= .04). CONCLUSIONS: LVZs ≥ 5% has a negative association with atrial %LASr. Thus, a simple 2D-STE measurement of %LASr can be used as a noninvasive method to evaluate significant LA remodeling and fibrosis in AF patients.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ecocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Estudos Prospectivos
6.
Echocardiography ; 32(3): 496-507, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25059625

RESUMO

BACKGROUND: Three-dimensional (3D) stress echocardiography is a relatively new technique offering the potential to acquire images of the entire left ventricle from 1 or 2 transducer positions in a time-efficient manner. Relative to two-dimensional (2D) imaging, the ability to quickly acquire full volume images during peak stress with 3D echocardiography can eliminate left ventricular (LV) foreshortening while reducing inter-operator variability. Our objectives were to (1) determine the practicality of a novel integrated 2D/3D stress protocol in incorporating 3D imaging into a standard 2D stress echocardiogram and (2) to determine whether the quality of imaging using the novel 2D/3D protocol was sufficient for interpretation. METHODS: Twenty-five patients referred for stress echocardiography underwent an integrated 2D/3D image acquisition protocol. LV segments were scored from 0 (absent or no clear endocardial visualization) to 3 (excellent/full visualization of endocardial border) with each modality. 2D segment quality scoring was compared with 3D. An integrated score was compared with either 2D or 3D imaging alone. RESULTS: Two-dimensional and 3D imaging were optimal for differing segments and the integrated protocol was superior to either modality alone. 3D imaging was superior in visualizing the anterior and anterolateral region of the base segments, compared to 2D imaging. 3D imaging was less useful for the base, the mid-inferior, and the inferoseptal segments, thus emphasizing the need to retain 2D imaging in stress echocardiography at this time. CONCLUSION: The integrated 2D/3D protocol approach to stress echocardiography is technically feasible and maximizes image quality of dobutamine stress echocardiography, improving patient assessment.


Assuntos
Dobutamina , Ecocardiografia sob Estresse/métodos , Ecocardiografia Tridimensional/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imagem Multimodal/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Sistemas Computacionais , Humanos , Aumento da Imagem/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Integração de Sistemas , Vasodilatadores
7.
J Pharmacol Exp Ther ; 322(2): 646-53, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17478614

RESUMO

Several quinones have been found to be effective in the treatment of some forms of cancer; however, their cumulative heart toxicity limits their use. The cannabinoid quinone HU-331 [3S,4R-p-benzoquinone-3-hydroxy-2-p-mentha-(1,8)-dien-3-yl-5-pentyl] is highly effective against tumor xenografts in nude mice. We report now a comparison of the anticancer activity of HU-331 and its cardiotoxicity with those of doxorubicin in vivo. General toxicity was assayed in Sabra, nude and SCID-NOD mice. The anticancer activity in vivo was assessed by measurement of the tumors with an external caliper in HT-29 and Raji tumor-bearing mice and by weighing the excised tumors. Left ventricular function was evaluated with transthoracic echocardiography. Myelotoxicity was evaluated by blood cell count. Cardiac troponin T (cTnT) plasma levels were determined by immunoassay. HU-331 was found to be much less cardiotoxic than doxorubicin. The control and the HU-331-treated groups gained weight, whereas the doxorubicin-treated group lost weight during the study. In HT-29 colon carcinoma, the tumor weight in the HU-331-treated group was 54% smaller than in the control group and 30% smaller than in the doxorubicin-treated group. In Raji lymphoma, the tumor weight in the HU-331-treated group was 65% smaller than in the control group and 33% smaller than in the doxorubicin-treated group. In contrast to doxorubicin, HU-331 did not generate reactive oxygen species in mice hearts (measured by protein carbonylation levels and malondialdehyde levels). In vivo, HU-331 was more active and less toxic than doxorubicin and thus it has a high potential for development as a new anticancer drug.


Assuntos
Canabidiol/análogos & derivados , Doxorrubicina/farmacologia , Coração/efeitos dos fármacos , Neoplasias/tratamento farmacológico , Animais , Antineoplásicos/farmacologia , Contagem de Células Sanguíneas , Peso Corporal/efeitos dos fármacos , Canabidiol/química , Canabidiol/farmacologia , Linhagem Celular Tumoral , Doxorrubicina/química , Ecocardiografia , Células HT29 , Coração/fisiopatologia , Humanos , Peroxidação de Lipídeos/efeitos dos fármacos , Masculino , Malondialdeído/metabolismo , Camundongos , Camundongos Endogâmicos NOD , Camundongos Endogâmicos , Camundongos Nus , Camundongos SCID , Estrutura Molecular , Miocárdio/metabolismo , Miocárdio/patologia , Neoplasias/sangue , Neoplasias/patologia , Carbonilação Proteica/efeitos dos fármacos , Troponina T/sangue , Ensaios Antitumorais Modelo de Xenoenxerto
8.
J Am Soc Echocardiogr ; 19(6): 835.e4-6, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16762766

RESUMO

A 75-year-old woman presented with shortness of breath. Computed tomography pulmonary angiogram revealed two penetrating aortic ulcers in the descending aorta. Transesophageal echocardiogram examination confirmed the diagnosis. In the operating department, a stent graft to the thoracic aorta was inserted.


Assuntos
Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/cirurgia , Prótese Vascular , Ecocardiografia Transesofagiana , Stents , Úlcera/diagnóstico por imagem , Úlcera/cirurgia , Idoso , Doenças da Aorta/complicações , Dispneia/diagnóstico , Dispneia/etiologia , Dispneia/prevenção & controle , Feminino , Humanos , Úlcera/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...