Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Neurointervention ; : 158-164, 2021.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-902840

RESUMO

Coil prolapse or migration is a rare but potentially serious complication that may occur during aneurysm embolization, with no standard management currently described. Here we describe our experience with the Embolus Retriever with Interlinked Cages (ERIC) device® (Microvention, Aliso Viejo, CA, USA) for the retrieval of prolapsed or migrated coils in a case series and Flow-Model analysis. First, a retrospective review was performed using our institution database for patients in which coil prolapse or migration occurred during aneurysm embolization, and data was collected and analyzed. Second, an in vitro Flow-Model analysis was performed comparing the ERIC device® with other stent retrievers for coil retrieval. In 2 cases, the ERIC device® successfully retrieved the displaced coil from intracranial circulation in 1 pass, after failure with other devices. In the Flow-Model, again the ERIC device® achieved success for retrieving a detached coil, whereas 2 other different stent retrievers failed to capture the coil after 2 attempts. The ERIC device® appears to be a safe and effective tool for retrieving a prolapsed or migrated coil from the intracranial circulation.

2.
Neurointervention ; : 158-164, 2021.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-895136

RESUMO

Coil prolapse or migration is a rare but potentially serious complication that may occur during aneurysm embolization, with no standard management currently described. Here we describe our experience with the Embolus Retriever with Interlinked Cages (ERIC) device® (Microvention, Aliso Viejo, CA, USA) for the retrieval of prolapsed or migrated coils in a case series and Flow-Model analysis. First, a retrospective review was performed using our institution database for patients in which coil prolapse or migration occurred during aneurysm embolization, and data was collected and analyzed. Second, an in vitro Flow-Model analysis was performed comparing the ERIC device® with other stent retrievers for coil retrieval. In 2 cases, the ERIC device® successfully retrieved the displaced coil from intracranial circulation in 1 pass, after failure with other devices. In the Flow-Model, again the ERIC device® achieved success for retrieving a detached coil, whereas 2 other different stent retrievers failed to capture the coil after 2 attempts. The ERIC device® appears to be a safe and effective tool for retrieving a prolapsed or migrated coil from the intracranial circulation.

3.
Neurointervention ; : 129-132, 2018.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-730253

RESUMO

A 64-year-old female presented with an incidentally-discovered right posterior inferior cerebral artery (PICA) aneurysm, initially treated in 2015 by simple coiling. Follow-up demonstrated significant coil compaction that required retreatment. Retreatment was done uneventfully using a Pipeline embolization device (PED) shield deployed starting from the basilar artery and ending at the V4 segment of the vertebral artery. Eight-weeks post-deployment, a follow-up digital subtraction imaging (DSA) and intravascular imaging with optical coherence tomography were obtained. The intravascular imaging demonstrated that the flow diverter had good wall apposition and concentric neointimal growth over the braid with exception to the areas that the PED was not in contact with the endothelial wall, such as at the right PICA ostium and at the vertebrobasilar junction. The entire procedure was safe, and the patient had no complications. In this article, we describe for the first time the assessment of the status of endothelial “healing” of the PED shield at 8-weeks.


Assuntos
Feminino , Humanos , Pessoa de Meia-Idade , Aneurisma , Artéria Basilar , Artérias Cerebrais , Seguimentos , Pica , Retratamento , Tomografia de Coerência Óptica , Artéria Vertebral
4.
Neurointervention ; : 133-137, 2018.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-730252

RESUMO

Endoluminal reconstruction with a flow diverter device has emerged as a viable and often preferable alternative to traditional techniques for the treatment of intracranial aneurysms. Precise measurement and device selection are mandatory steps when considering flow diverters usage in order to avoid potential complications. In this sense, incomplete wall-apposition has been described as a predictive factor for immediate in-stent and delayed thrombosis after stent use. One significant usage limitation of flow diverter devices is the parent artery diameter, since the maximum opening of the sizes available are recommended for vessel diameters between 5.2–5.75 mm. Here we present the first clinical use of the largest flow diverter available, the 6×50 mm DERIVO embolization device (Acandis GmbH & Co. KG, Pforzheim, Germany), into the arterial circulation for a cervical internal carotid artery endovascular reconstruction. This is a new device for large or fusiform aneurysms requiring flow diversion, especially located in the vertebrobasilar system or extracranial segments.


Assuntos
Humanos , Aneurisma , Artérias , Artéria Carótida Interna , Aneurisma Intracraniano , Pais , Stents , Trombose
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...