Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
2.
J Neurotrauma ; 41(13-14): 1533-1549, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38481124

RESUMO

Sports-related concussions may cause white matter injuries and persistent post-concussive symptoms (PPCS). We hypothesized that athletes with PPCS would have neurocognitive impairments and white matter abnormalities that could be revealed by advanced neuroimaging using ultra-high field strength diffusion tensor (DTI) and diffusion kurtosis (DKI) imaging metrics and cerebrospinal fluid (CSF) biomarkers. A cohort of athletes with PPCS severity limiting the ability to work/study and participate in sport school and/or social activities for ≥6 months completed 7T magnetic resonance imaging (MRI) (morphological T1-weighed volumetry, DTI and DKI), extensive neuropsychological testing, symptom rating, and CSF biomarker sampling. Twenty-two athletes with PPCS and 22 controls were included. Concussed athletes performed below norms and significantly lower than controls on all but one of the psychometric neuropsychology tests. Supratentorial white and gray matter, as well as hippocampal volumes did not differ between concussed athletes and controls. However, of the 72 examined white matter tracts, 16% of DTI and 35% of DKI metrics (in total 28%) were significantly different between concussed athletes and controls. DKI fractional anisotropy and axial kurtosis were increased, and DKI radial diffusivity and radial kurtosis decreased in concussed athletes when compared with controls. CSF neurofilament light (NfL; an axonal injury marker), although not glial fibrillary acidic protein, correlated with several diffusion metrics. In this first 7T DTI and DKI study investigating PPCS, widespread microstructural alterations were observed in the white matter, correlating with CSF markers of axonal injury. More white matter changes were observed using DKI than using DTI. These white matter alterations may indicate persistent pathophysiological processes following concussion in sport.


Assuntos
Atletas , Traumatismos em Atletas , Concussão Encefálica , Substância Branca , Humanos , Masculino , Substância Branca/diagnóstico por imagem , Substância Branca/patologia , Feminino , Traumatismos em Atletas/diagnóstico por imagem , Traumatismos em Atletas/patologia , Traumatismos em Atletas/complicações , Traumatismos em Atletas/líquido cefalorraquidiano , Adulto Jovem , Concussão Encefálica/diagnóstico por imagem , Concussão Encefálica/patologia , Concussão Encefálica/líquido cefalorraquidiano , Adulto , Adolescente , Imagem de Tensor de Difusão/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Síndrome Pós-Concussão/diagnóstico por imagem , Síndrome Pós-Concussão/patologia , Síndrome Pós-Concussão/líquido cefalorraquidiano
3.
Interv Neuroradiol ; : 15910199231183130, 2023 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-37312529

RESUMO

BACKGROUND: Perforator aneurysms of the basilar artery (PABA) are rare causes of subarachnoid haemorrhage (SAH) and challenging to diagnose. We present two cases of SAH caused by PABA diagnosed by cone beam computed tomography angiography (CBCTA) and a novel non-invasive method - 7T magnetic resonance imaging (7T MRI). METHODS: Two patients with SAH, diagnosed with PABA, were imaged on day 9 and 13 after onset, respectively, with CBCTA and 7T MR angiography (MRA) performed on the day after and at follow-up at 3 months. RESULTS: All four 7T MRI examinations in the two patients were technically successful with fully diagnostic images. No endovascular treatment was performed and control with 7T MRA at 3 months showed no remaining aneurysms. CONCLUSION: PABA can be imaged with 7T MRI - a novel non-invasive method, allowing non-invasive follow-up to monitor this rare cause of SAH.

4.
NMR Biomed ; 36(6): e4863, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36310022

RESUMO

Dynamic glucose-enhanced (DGE) MRI is used to study the signal intensity time course (tissue response curve) after D-glucose injection. D-glucose has potential as a biodegradable alternative or complement to gadolinium-based contrast agents, with DGE being comparable with dynamic contrast-enhanced (DCE) MRI. However, the tissue uptake kinetics as well as the detection methods of DGE differ from DCE MRI, and it is relevant to compare these techniques in terms of spatiotemporal enhancement patterns. This study aims to develop a DGE analysis method based on tissue response curve shapes, and to investigate whether DGE MRI provides similar or complementary information to DCE MRI. Eleven patients with suspected gliomas were studied. Tissue response curves were measured for DGE and DCE MRI at 7 T and the area under the curve (AUC) was assessed. Seven types of response curve shapes were postulated and subsequently identified by deep learning to create color-coded "curve maps" showing the spatial distribution of different curve types. DGE AUC values were significantly higher in lesions than in normal tissue (p < 0.007). Furthermore, the distribution of curve types differed between lesions and normal tissue for both DGE and DCE. The DGE and DCE response curves in a 6-min postinjection time interval were classified as the same curve type in 20% of the lesion voxels, which increased to 29% when a 12-min DGE time interval was considered. While both DGE and DCE tissue response curve-shape analysis enabled differentiation of lesions from normal brain tissue in humans, their enhancements were neither temporally identical nor confined entirely to the same regions. Curve maps can provide accessible and intuitive information about the shape of DGE response curves, which is expected to be useful in the continued work towards the interpretation of DGE uptake curves in terms of D-glucose delivery, transport, and metabolism.


Assuntos
Neoplasias Encefálicas , Glucose , Humanos , Imageamento por Ressonância Magnética/métodos , Meios de Contraste , Neoplasias Encefálicas/diagnóstico por imagem , Encéfalo/diagnóstico por imagem
5.
Magn Reson Med ; 88(2): 770-786, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35403247

RESUMO

PURPOSE: Respiration-related CSF flow through the cerebral aqueduct may be useful for elucidating physiology and pathophysiology of the glymphatic system, which has been proposed as a mechanism of brain waste clearance. Therefore, we aimed to (1) develop a real-time (CSF) flow imaging method with high spatial and sufficient temporal resolution to capture respiratory effects, (2) validate the method in a phantom setup and numerical simulations, and (3) apply the method in vivo and quantify its repeatability and correlation with different respiratory conditions. METHODS: A golden-angle radial flow sequence (reconstructed temporal resolution 168 ms, spatial resolution 0.6 mm) was implemented on a 7T MRI scanner and reconstructed using compressed sensing. A phantom setup mimicked simultaneous cardiac and respiratory flow oscillations. The effect of temporal resolution and vessel diameter was investigated numerically. Healthy volunteers (n = 10) were scanned at four different respiratory conditions, including repeat scans. RESULTS: Phantom data show that the developed sequence accurately quantifies respiratory oscillations (ratio real-time/reference QR  = 0.96 ± 0.02), but underestimates the rapid cardiac oscillations (ratio QC  = 0.46 ± 0.14). Simulations suggest that QC can be improved by increasing temporal resolution. In vivo repeatability was moderate to very strong for cranial and caudal flow (intraclass correlation coefficient range: 0.55-0.99) and weak to strong for net flow (intraclass correlation coefficient range: 0.48-0.90). Net flow was influenced by respiratory condition (p < 0.01). CONCLUSIONS: The presented real-time flow MRI method can quantify respiratory-related variations of CSF flow in the cerebral aqueduct, but it underestimates rapid cardiac oscillations. In vivo, the method showed good repeatability and a relationship between flow and respiration.


Assuntos
Aqueduto do Mesencéfalo , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Líquido Cefalorraquidiano/diagnóstico por imagem , Líquido Cefalorraquidiano/fisiologia , Humanos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Respiração
6.
J Neurotrauma ; 2022 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-35171721

RESUMO

Symptoms of vestibular dysfunction such as dizziness and vertigo are common after sports-related concussions (SRC) and associated with a worse outcome and a prolonged recovery. Vestibular dysfunction after SRC can be because of an impairment of the peripheral or central neural parts of the vestibular system. The aim of the present study was to establish the cause of vestibular impairment in athletes with SRC who have persisting post-concussive symptoms (PPCS). We recruited 42 participants-21 athletes with previous SRCs and PPCS ≥6 months and 21 healthy athletic age- and sex-matched controls-who underwent symptom rating, a detailed test battery of vestibular function and 7T magnetic resonance imaging with diffusion tensor imaging (DTI) and diffusion kurtosis imaging (DKI) of cerebellar white matter tracts, and T1-weighted imaging for cerebellar volumetrics. Vestibular dysfunction was observed in 13 SRC athletes and three controls (p = 0.001). Athletes with vestibular dysfunction reported more pronounced symptoms on the Dizziness Handicap Inventory (DHI; p < 0.001) and the Hospital Anxiety and Depression Scale (HADS; p < 0.001). No significant differences in DTI metrics were found, while in DKI two metrics were observed in the superior and/or inferior cerebellar tracts. Cerebellar gray and white matter volumes were similar in athletes with SRC and controls. Compared with controls, pathological video head impulse test results (vHIT; p < 0.001) and cervical vestibular evoked myogenic potentials (cVEMP; p = 0.002) were observed in athletes with SRC, indicating peripheral vestibular dysfunction and specifically suggesting injury to the inferior vestibular nerve. In athletes with persisting symptoms after SRC, vestibular dysfunction is associated with injury to the inferior vestibular nerve.

7.
Eur Radiol ; 32(2): 1362-1370, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34378077

RESUMO

OBJECTIVE: Injuries to the wrist are, due to its small size and complex anatomical structures, difficult to assess by MR, and surgical interventions such as diagnostic arthroscopy are often necessary. Therefore, improved visualization using non-invasive methods could be of clinical value. As a first step of improvement, the purpose of this study was to evaluate visualization of anatomical structures at 7T compared with 3T MR. METHODS: Eighteen healthy volunteers (three males and three females from each age decade between 20 and 49 years) were examined with 7T and 3T MR. Four musculoskeletal radiologists graded 2D and 3D images on a five-level grading scale for visibility of ligaments, cartilage, nerves, trabecular bone, and tendons, as well as overall image quality (i.e., edge sharpness, perceived tissue contrast, and presence of artefacts). Statistical analysis was done using a visual grading characteristics (VGC) analysis. RESULTS: Visibility of cartilage, trabecular bone, tendons, nerves, and ligaments was graded significantly higher at 7T with an area under the curve (AUCVGC) of 0.62-0.88 (95% confidence interval [CI] 0.50-0.97, p = < 0.0001-0.03) using either 2D or 3D imaging. Imaging with 3T was not graded as superior to 7T for any structure. Image quality was also significantly superior at 7T, except for artefacts, where no significant differences were found. CONCLUSIONS: Tendons, trabecular bone, nerves, and ligaments were all significantly better visualized at 7T compared to 3T. KEY POINTS: • MRI of the wrist at 7T with a commercially available wrist coil is feasible at similar acquisition times as for 3T MRI. • The current study showed 7T to be superior to 3T in the visualization of anatomical structures of the wrist, including ligaments, tendons, nerves, and trabecular bone. • Image quality was significantly superior at 7T, except for artefacts, where no significant differences were found.


Assuntos
Traumatismos do Punho , Punho , Adulto , Feminino , Humanos , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Punho/diagnóstico por imagem , Articulação do Punho/diagnóstico por imagem , Adulto Jovem
8.
BMC Med Imaging ; 21(1): 121, 2021 08 11.
Artigo em Inglês | MEDLINE | ID: mdl-34380454

RESUMO

BACKGROUND: Carotid atherosclerotic plaques with intraplaque hemorrhage (IPH) are associated with elevated stroke risk. IPH is predominantly imaged based on paramagnetic properties of the upstream hemoglobin degradation product methemoglobin. This is an explorative observational study to test the feasibility of a spoiled gradient echo based T2* weighted MRI sequence (3D MEDIC) for carotid plaque imaging, and to compare signs suggestive of the downstream degradation product hemosiderin on 3D MEDIC with signs of methemoglobin on a T1wBB sequence. METHODS: Patients with recent TIA or stroke were selected based on the presence on non-calcified plaque components on CTA to promote an enriched prevalence of IPH in the material. Patients (n = 42) underwent 3T MRI with 3D MEDIC and 2D turbo spin echo T1w black blood (T1wBB). Images were independently evaluated by two neuroradiologists and Cohens Kappa was used for inter-reader agreement for each sequence. RESULTS: The technical feasibility for 3D MEDIC, was 34/42 patients (81%). Non-calcified plaque components with susceptibility effect without simultaneous T1-shortening-a combination suggestive of hemosiderin, was seen in 13/34 of the plaques. An equally large group display elevated T1w signal in combination with signal loss on 3D MEDIC, a combination suggestive of both hemosiderin and methemoglobin. Cohen's kappa for inter-reader agreement was 0.64 (CI 0.345-0.925) for 3D MEDIC and 0.94 (CI 0.81-1.00) for T1wBB. CONCLUSIONS: 3D MEDIC shows signal loss, without elevated T1w signal on T1wBB, in non-calcified tissue in many plaques in this group of patients. If further studies, including histological verification, confirm that the 3D MEDIC susceptibility effect is indeed caused by hemosiderin, 3D MEDIC could aid in the detection of IPH, beyond elevation of T1w signal.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Hemorragia/diagnóstico por imagem , Hemossiderina/análise , Imageamento por Ressonância Magnética/métodos , Metemoglobina/análise , Placa Aterosclerótica/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Hemorragia/etiologia , Humanos , Ataque Isquêmico Transitório/complicações , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/química , Placa Aterosclerótica/complicações , Acidente Vascular Cerebral/complicações
9.
J Vis Exp ; (168)2021 02 19.
Artigo em Inglês | MEDLINE | ID: mdl-33682856

RESUMO

The overall goal of this article is to demonstrate a state-of-the-art ultrahigh field (UHF) magnetic resonance (MR) protocol of the brain at 7.0 Tesla in multiple sclerosis (MS) patients. MS is a chronic inflammatory, demyelinating, neurodegenerative disease that is characterized by white and gray matter lesions. Detection of spatially and temporally disseminated T2-hyperintense lesions by the use of MRI at 1.5 T and 3 T represents a crucial diagnostic tool in clinical practice to establish accurate diagnosis of MS based on the current version of the 2017 McDonald criteria. However, the differentiation of MS lesions from brain white matter lesions of other origins can sometimes be challenging due to their resembling morphology at lower magnetic field strengths (typically 3 T). Ultrahigh field MR (UHF-MR) benefits from increased signal-to-noise ratio and enhanced spatial resolution, both key to superior imaging for more accurate and definitive diagnoses of subtle lesions. Hence, MRI at 7.0 T has shown encouraging results to overcome the challenges of MS differential diagnosis by providing MS-specific neuroimaging markers (e.g., central vein sign, hypointense rim structures and differentiation of MS grey matter lesions). These markers and others can be identified by other MR contrasts other than T1 and T2 (T2*, phase, diffusion) and substantially improve the differentiation of MS lesions from those occurring in other neuroinflammatory conditions such as neuromyelitis optica and Susac syndrome. In this article, we describe our current technical approach to study cerebral white and grey matter lesions in MS patients at 7.0 T using different MR acquisition methods. The up-to-date protocol includes the preparation of the MR setup including the radio-frequency coils customized for UHF-MR, standardized screening, safety and interview procedures with MS patients, patient positioning in the MR scanner and acquisition of dedicated brain scans tailored for examining MS.


Assuntos
Imageamento por Ressonância Magnética , Esclerose Múltipla/diagnóstico por imagem , Córtex Cerebral/diagnóstico por imagem , Córtex Cerebral/patologia , Humanos , Processamento de Imagem Assistida por Computador , Esclerose Múltipla/patologia , Neuroimagem , Software , Substância Branca/diagnóstico por imagem , Substância Branca/patologia
10.
J Cereb Blood Flow Metab ; 41(9): 2137-2149, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33461408

RESUMO

Age-related neurodegenerative diseases are a growing burden to society, and many are sporadic, meaning that the environment, diet and lifestyle play significant roles. Cerebrospinal fluid (CSF)-mediated clearing of brain waste products via perivascular pathways, named the glymphatic system, is receiving increasing interest, as it offers unexplored perspectives on understanding neurodegenerative diseases. The glymphatic system is involved in clearance of metabolic by-products such as amyloid-ß from the brain, and its function is believed to lower the risk of developing some of the most common neurodegenerative diseases. Here, we present magnetic resonance imaging (MRI) data on the heart cycle's control of CSF flow in humans which corroborates findings from animal studies. We also review the importance of sleep, diet, vascular health for glymphatic clearance and find that these factors are also known players in brain longevity.


Assuntos
Encéfalo/patologia , Sistema Glinfático/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Doenças Neurodegenerativas/terapia , Humanos , Doenças Neurodegenerativas/patologia
11.
Neurology ; 96(7): 327-341, 2021 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-33361257

RESUMO

Identifying a structural brain lesion on MRI has important implications in epilepsy and is the most important factor that correlates with seizure freedom after surgery in patients with drug-resistant focal onset epilepsy. However, at conventional magnetic field strengths (1.5 and 3T), only approximately 60%-85% of MRI examinations reveal such lesions. Over the last decade, studies have demonstrated the added value of 7T MRI in patients with and without known epileptogenic lesions from 1.5 and/or 3T. However, translation of 7T MRI to clinical practice is still challenging, particularly in centers new to 7T, and there is a need for practical recommendations on targeted use of 7T MRI in the clinical management of patients with epilepsy. The 7T Epilepsy Task Force-an international group representing 21 7T MRI centers with experience from scanning over 2,000 patients with epilepsy-would hereby like to share its experience with the neurology community regarding the appropriate clinical indications, patient selection and preparation, acquisition protocols and setup, technical challenges, and radiologic guidelines for 7T MRI in patients with epilepsy. This article mainly addresses structural imaging; in addition, it presents multiple nonstructural MRI techniques that benefit from 7T and hold promise as future directions in epilepsy. Answering to the increased availability of 7T MRI as an approved tool for diagnostic purposes, this article aims to provide guidance on clinical 7T MRI epilepsy management by giving recommendations on referral, suitable 7T MRI protocols, and image interpretation.


Assuntos
Encéfalo/diagnóstico por imagem , Epilepsia/diagnóstico por imagem , Imageamento por Ressonância Magnética , Consenso , Humanos
12.
BMC Med Imaging ; 20(1): 128, 2020 12 09.
Artigo em Inglês | MEDLINE | ID: mdl-33297985

RESUMO

BACKGROUND: Ultra-high field magnetic resonance imaging (MR) may be used to improve intracranial blood flow measurements. However, standard cardiac synchronization methods tend to fail at ultra-high field MR. Therefore, this study aims to investigate an alternative synchronization technique using Doppler ultrasound. METHODS: Healthy subjects (n = 9) were examined with 7T MR. Flow was measured in the M1-branch of the middle cerebral artery (MCA) and in the cerebral aqueduct (CA) using through-plane phase contrast (2D flow). Flow in the circle of Willis was measured with three-dimensional, three-directional phase contrast (4D flow). Scans were gated with Doppler ultrasound (DUS) and electrocardiogram (ECG), and pulse oximetry data (POX) was collected simultaneously. False negative and false positive trigger events were counted for ECG, DUS and POX, and quantitative flow measures were compared. RESULTS: There were fewer false positive triggers for DUS compared to ECG (5.3 ± 11 vs. 25 ± 31, p = 0.031), while no other measured parameters differed significantly. Net blood flow in M1 was similar between DUS and ECG for 2D flow (1.5 ± 0.39 vs. 1.6 ± 0.41, bias ± 1.96SD: - 0.021 ± 0.36) and 4D flow (1.8 ± 0.48 vs. 9 ± 0.59, bias ± 1.96SD: - 0.086 ± 0.57 ml). Net CSF flow per heart beat in the CA was also similar for DUS and ECG (3.6 ± 2.1 vs. 3.0 ± 5.8, bias ± 1.96SD: 0.61 ± 13.6 µl). CONCLUSION: Gating with DUS produced fewer false trigger events than using ECG, with similar quantitative flow values. DUS gating is a promising technique for cardiac synchronization at 7T.


Assuntos
Velocidade do Fluxo Sanguíneo , Técnicas de Imagem de Sincronização Cardíaca/métodos , Artérias Cerebrais/diagnóstico por imagem , Ultrassonografia Doppler/métodos , Adulto , Artérias Cerebrais/fisiologia , Eletrocardiografia , Reações Falso-Negativas , Reações Falso-Positivas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Oximetria , Valores de Referência , Adulto Jovem
13.
Magn Reson Med ; 84(4): 2231-2245, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32270549

RESUMO

PURPOSE: Three-dimensional, time-resolved blood flow measurement (4D-flow) is a powerful research and clinical tool, but improved resolution and scan times are needed. Therefore, this study aims to (1) present a postprocessing framework for optimization-driven simulation-based flow imaging, called 4D-flow High-resolution Imaging with a priori Knowledge Incorporating the Navier-Stokes equations and the discontinuous Galerkin method (4D-flow HIKING), (2) investigate the framework in synthetic tests, (3) perform phantom validation using laser particle imaging velocimetry, and (4) demonstrate the use of the framework in vivo. METHODS: An optimizing computational fluid dynamics solver including adjoint-based optimization was developed to fit computational fluid dynamics solutions to 4D-flow data. Synthetic tests were performed in 2D, and phantom validation was performed with pulsatile flow. Reference velocity data were acquired using particle imaging velocimetry, and 4D-flow data were acquired at 1.5 T. In vivo testing was performed on intracranial arteries in a healthy volunteer at 7 T, with 2D flow as the reference. RESULTS: Synthetic tests showed low error (0.4%-0.7%). Phantom validation showed improved agreement with laser particle imaging velocimetry compared with input 4D-flow in the horizontal (mean -0.05 vs -1.11 cm/s, P < .001; SD 1.86 vs 4.26 cm/s, P < .001) and vertical directions (mean 0.05 vs -0.04 cm/s, P = .29; SD 1.36 vs 3.95 cm/s, P < .001). In vivo data show a reduction in flow rate error from 14% to 3.5%. CONCLUSIONS: Phantom and in vivo results from 4D-flow HIKING show promise for future applications with higher resolution, shorter scan times, and accurate quantification of physiological parameters.


Assuntos
Hidrodinâmica , Imageamento Tridimensional , Velocidade do Fluxo Sanguíneo , Humanos , Imageamento por Ressonância Magnética , Imagens de Fantasmas
14.
J Magn Reson Imaging ; 52(4): 1265-1276, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32196818

RESUMO

BACKGROUND: Ultrahigh-field (UHF) MRI advances towards clinical use. Patient compliance is generally high, but few large-scale studies have investigated the effects experienced in 7T MRI systems, especially considering peripheral nerve stimulation (PNS) and caregiving. PURPOSE: To evaluate the quantity, the intensity, and subjective experiences from short-term effects, focusing on the levels of comfort and compliance of subjects. STUDY TYPE: Prospective. POPULATION: In all, 954 consecutive MRIs in 801 subjects for 3 years. FIELD STRENGTH: 7T. ASSESSMENT: After the 7T examination, a questionnaire was used to collect data. STATISTICAL TESTS: Descriptive statistics, Spearman's rank correlation, Mann-Whitney U-test, and t-test. RESULTS: The majority (63%) of subjects agreed that the MRI experience was comfortable and 93% would be willing to undergo future 7T MRI as a patient (5% undecided) and 82% for research purposes (12% undecided). The most common short-term effects experienced were dizziness (81%), inconsistent movement (68%), PNS (63%), headache (40%), nausea (32%), metallic taste (12%), and light flashes (8%). Of the subjects who reported having PNS (n = 603), 44% experienced PNS as "not uncomfortable at all," 45% as "little or very little uncomfortable," and 11% as "moderate to very much uncomfortable." Scanner room temperature was experienced more comfortable before (78%) than during (58%) examinations, and the noise level was acceptable by 90% of subjects. Anxiety before the examination was reported by 43%. Patients differed from healthy volunteers regarding an experience of headache, metallic taste, dizziness, or anxiety. Room for improvement was pointed out after 117 examinations concerning given information (n = 73), communication and sound system (n = 35), or nursing care (n = 15). DATA CONCLUSION: Subjectively reported effects occur in actively shielded 7T MRI and include physiological responses and individual psychological issues. Although leaving room for improvement, few subjects experienced these effects being so uncomfortable that they would lead to aversion to future UHF examinations. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 5 J. Magn. Reson. Imaging 2020;52:1265-1276.


Assuntos
Imageamento por Ressonância Magnética , Vertigem , Voluntários Saudáveis , Humanos , Movimento , Estudos Prospectivos
15.
Neuroradiology ; 61(10): 1145-1153, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31240344

RESUMO

PURPOSE: Reports from 3-T vessel wall MRI imaging have shown contrast enhancement following thrombectomy for acute stroke, suggesting potential intimal damage. Comparisons have shown higher SNR and more lesions detected by vessel wall imaging when using 7 T compared with 3 T. The aim of this study was to investigate the vessel walls after stent retriever thrombectomy using high-resolution vessel wall imaging at 7 T. METHODS: Seven patients with acute stroke caused by occlusion of the distal internal carotid artery (T-occlusion), or proximal medial cerebral artery, and treated by stent retriever thrombectomy with complete recanalization were included and examined by 7-T MRI within 2 days. The MRI protocol included a high-resolution black blood sequence with prospective motion correction (iMOCO), acquired before and after contrast injection. Flow measurements were performed in the treated and untreated M1 segments. RESULTS: All subjects completed the MRI examination. Image quality was independently rated as excellent by two neuroradiologists for all cases, and the level of motion artifacts did not impair diagnostic quality, despite severe motion in some cases. Contrast enhancement correlated with the deployment location of the stent retrievers. Flow data showed complete restoration of flow after treatment. CONCLUSION: Vessel wall imaging with prospective motion correction can be performed in patients following thrombectomy with excellent imaging quality at 7 T. We show that vessel wall contrast enhancement is the normal post-operative state and corresponds to the deployment location of the stent retriever.


Assuntos
Estenose das Carótidas/cirurgia , Angiografia Cerebral/métodos , Infarto da Artéria Cerebral Média/cirurgia , Angiografia por Ressonância Magnética , Imagem de Perfusão/métodos , Acidente Vascular Cerebral/cirurgia , Trombectomia , Doença Aguda , Idoso , Idoso de 80 Anos ou mais , Artéria Carótida Interna/diagnóstico por imagem , Artéria Carótida Interna/cirurgia , Estenose das Carótidas/diagnóstico por imagem , Feminino , Humanos , Aumento da Imagem , Imageamento Tridimensional/métodos , Infarto da Artéria Cerebral Média/diagnóstico por imagem , Arteriosclerose Intracraniana/diagnóstico por imagem , Arteriosclerose Intracraniana/cirurgia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Acidente Vascular Cerebral/diagnóstico por imagem
16.
J Cardiovasc Magn Reson ; 21(1): 30, 2019 05 20.
Artigo em Inglês | MEDLINE | ID: mdl-31104632

RESUMO

BACKGROUND: A velocity offset error in phase contrast cardiovascular magnetic resonance (CMR) imaging is a known problem in clinical assessment of flow volumes in vessels around the heart. Earlier studies have shown that this offset error is clinically relevant over different systems, and cannot be removed by protocol optimization. Correction methods using phantom measurements are time consuming, and assume reproducibility of the offsets which is not the case for all systems. An alternative previously published solution is to correct the in-vivo data in post-processing, interpolating the velocity offset from stationary tissue within the field-of-view. This study aims to validate this interpolation-based offset correction in-vivo in a multi-vendor, multi-center setup. METHODS: Data from six 1.5 T CMR systems were evaluated, with two systems from each of the three main vendors. At each system aortic and main pulmonary artery 2D flow studies were acquired during routine clinical or research examinations, with an additional phantom measurement using identical acquisition parameters. To verify the phantom acquisition, a region-of-interest (ROI) at stationary tissue in the thorax wall was placed and compared between in-vivo and phantom measurements. Interpolation-based offset correction was performed on the in-vivo data, after manually excluding regions of spatial wraparound. Correction performance of different spatial orders of interpolation planes was evaluated. RESULTS: A total of 126 flow measurements in 82 subjects were included. At the thorax wall the agreement between in-vivo and phantom was - 0.2 ± 0.6 cm/s. Twenty-eight studies were excluded because of a difference at the thorax wall exceeding 0.6 cm/s from the phantom scan, leaving 98. Before correction, the offset at the vessel as assessed in the phantom was - 0.4 ± 1.5 cm/s, which resulted in a - 5 ± 16% error in cardiac output. The optimal order of the interpolation correction plane was 1st order, except for one system at which a 2nd order plane was required. Application of the interpolation-based correction revealed a remaining offset velocity of 0.1 ± 0.5 cm/s and 0 ± 5% error in cardiac output. CONCLUSIONS: This study shows that interpolation-based offset correction reduces the offset with comparable efficacy as phantom measurement phase offset correction, without the time penalty imposed by phantom scans. TRIAL REGISTRATION: The study was registered in The Netherlands National Trial Register (NTR) under TC 4865 . Registered 19 September 2014. Retrospectively registered.


Assuntos
Aorta/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imagem de Perfusão/métodos , Artéria Pulmonar/diagnóstico por imagem , Adulto , Aorta/fisiopatologia , Velocidade do Fluxo Sanguíneo , Europa (Continente) , Feminino , Humanos , Imageamento por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão/instrumentação , Imagens de Fantasmas , Valor Preditivo dos Testes , Artéria Pulmonar/fisiopatologia , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Adulto Jovem
17.
Bioelectromagnetics ; 40(4): 234-249, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30920671

RESUMO

The objective of this study was to evaluate occurrence and strength of short-term effects experienced by study participants in an actively shielded (AS) 7 tesla (7 T) magnetic resonance (MR) scanner, to compare results with earlier reports on passively shielded (PS) 7 T MR scanners, and to outline possible healthcare strategies to improve patient compliance. Study participants (n = 124) completed a web-based questionnaire directly after being examined in an AS 7 T MR (n = 154 examinations). Most frequently experienced short-term effects were dizziness (84%) and inconsistent movement (70%), especially while moving into or out of the magnet. Peripheral nerve stimulation (PNS)-twitching-was experienced in 67% of research examinations and showed a dependence between strength of twitches and recorded predicted PNS values. Of the participants, 74% experienced noise levels as acceptable and the majority experienced body and room temperature as comfortable. Of the study participants, 95% felt well-informed and felt they had had good contact with the staff before the examination. Willingness to undergo a future 7 T examination was high (>90%). Our study concludes short-term effects are often experienced during examinations in an AS 7 T MR, leaving room for improvement in nursing care strategies to increase patient compliance. Bioelectromagnetics. 2019;9999:XX-XX. © 2019 The Authors. Bioelectromagnetics Published by Wiley Periodicals, Inc.


Assuntos
Imageamento por Ressonância Magnética/efeitos adversos , Exposição à Radiação/efeitos adversos , Tontura/etiologia , Humanos , Campos Magnéticos , Movimento , Cooperação do Paciente , Inquéritos e Questionários
18.
Acta Radiol ; 60(3): 327-337, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30479136

RESUMO

BACKGROUND: 4D-flow magnetic resonance imaging (MRI) is increasingly used. PURPOSE: To validate 4D-flow sequences in phantom and in vivo, comparing volume flow and kinetic energy (KE) head-to-head, with and without respiratory gating. MATERIAL AND METHODS: Achieva dStream (Philips Healthcare) and MAGNETOM Aera (Siemens Healthcare) 1.5-T scanners were used. Phantom validation measured pulsatile, three-dimensional flow with 4D-flow MRI and laser particle imaging velocimetry (PIV) as reference standard. Ten healthy participants underwent three cardiac MRI examinations each, consisting of cine-imaging, 2D-flow (aorta, pulmonary artery), and 2 × 2 accelerated 4D-flow with (Resp+) and without (Resp-) respiratory gating. Examinations were acquired consecutively on both scanners and one examination repeated within two weeks. Volume flow in the great vessels was compared between 2D- and 4D-flow. KE were calculated for all time phases and voxels in the left ventricle. RESULTS: Phantom results showed high accuracy and precision for both scanners. In vivo, higher accuracy and precision ( P < 0.001) was found for volume flow for the Aera prototype with Resp+ (-3.7 ± 10.4 mL, r = 0.89) compared to the Achieva product sequence (-17.8 ± 18.6 mL, r = 0.56). 4D-flow Resp- on Aera had somewhat larger bias (-9.3 ± 9.6 mL, r = 0.90) compared to Resp+ ( P = 0.005). KE measurements showed larger differences between scanners on the same day compared to the same scanner at different days. CONCLUSION: Sequence-specific in vivo validation of 4D-flow is needed before clinical use. 4D-flow with the Aera prototype sequence with a clinically acceptable acquisition time (<10 min) showed acceptable bias in healthy controls to be considered for clinical use. Intra-individual KE comparisons should use the same sequence.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Técnicas de Imagem Cardíaca/instrumentação , Sistema Cardiovascular/diagnóstico por imagem , Imageamento por Ressonância Magnética/instrumentação , Adulto , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional/instrumentação , Masculino , Imagens de Fantasmas , Fluxo Pulsátil , Reprodutibilidade dos Testes , Técnicas de Imagem de Sincronização Respiratória/instrumentação
19.
Tomography ; 4(4): 164-171, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30588502

RESUMO

Dynamic glucose-enhanced (DGE) imaging uses chemical exchange saturation transfer magnetic resonance imaging to retrieve information about the microcirculation using infusion of a natural sugar (D-glucose). However, this new approach is not yet well understood with respect to the dynamic tissue response. DGE time curves for arteries, normal brain tissue, and cerebrospinal fluid (CSF) were analyzed in healthy volunteers and compared with the time dependence of sampled venous plasma blood glucose levels. The arterial response curves (arterial input function [AIF]) compared reasonably well in shape with the time curves of the sampled glucose levels but could also differ substantially. The brain tissue response curves showed mainly negative responses with a peak intensity that was of the order of 10 times smaller than the AIF peak and a shape that was susceptible to both noise and partial volume effects with CSF, attributed to the low contrast-to-noise ratio. The CSF response curves showed a rather large and steady increase of the glucose uptake during the scan, due to the rapid uptake of D-glucose in CSF. Importantly, and contrary to gadolinium studies, the curves differed substantially among volunteers, which was interpreted to be caused by variations in insulin response. In conclusion, while AIFs and tissue response curves can be measured in DGE experiments, partial volume effects, low concentration of D-glucose in tissue, and osmolality effects between tissue and blood may prohibit quantification of normal tissue perfusion parameters. However, separation of tumor responses from normal tissue responses would most likely be feasible.

20.
Acta Radiol ; 59(8): 988-996, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29141450

RESUMO

Background The cerebral aqueduct is a central conduit for cerebrospinal fluid (CSF), and non-invasive quantification of CSF flow in the aqueduct may be an important tool for diagnosis and follow-up of treatment. Magnetic resonance (MR) methods at clinical field strengths are limited by low spatial resolution. Purpose To investigate the feasibility of high-resolution through-plane MR flow measurements (2D-PC) in the cerebral aqueduct at high field strength (7T). Material and Methods 2D-PC measurements in the aqueduct were performed in nine healthy individuals at 7T. Measurement accuracy was determined using a phantom. Aqueduct area, mean velocity, maximum velocity, minimum velocity, net flow, and mean flow were determined using in-plane resolutions 0.8 × 0.8, 0.5 × 0.5, 0.3 × 0.3, and 0.2 × 0.2 mm2. Feasibility criteria were defined based on scan time and spatial and temporal resolution. Results Phantom validation of 2D-PC MR showed good accuracy. In vivo, stroke volume was -8.2 ± 4.4, -4.7 ± 2.8, -6.0 ± 3.8, and -3.7 ± 2.1 µL for 0.8 × 0.8, 0.5 × 0.5, 0.3 × 0.3, and 0.2 × 0.2 mm2, respectively. The scan with 0.3 × 0.3 mm2 resolution fulfilled the feasibility criteria for a wide range of heart rates and aqueduct diameters. Conclusion 7T MR enables non-invasive quantification of CSF flow and velocity in the cerebral aqueduct with high spatial resolution.


Assuntos
Aqueduto do Mesencéfalo/diagnóstico por imagem , Líquido Cefalorraquidiano/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Aqueduto do Mesencéfalo/metabolismo , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...