Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Sens ; 7(11): 3440-3449, 2022 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-36305608

RESUMO

The knowledge of the exact oxygen partial pressure in tissue is crucial for patient care and in the treatment of ischemic medical conditions. However, current methods to assess oxygen partial pressure in tissue suffer from a variety of disadvantages, including complex equipment and procedures that necessitate trained personnel. Additionally, the barrier function of the stratum corneum reduces oxygen exchange and can consequently hamper surface measurements of rapidly changing oxygen partial pressure in tissue. To overcome these challenges, a novel, easy-to-use technique to monitor the oxygen partial pressure in tissue using microneedle arrays (MNAs) has been developed. The MNAs can be made from poly(ethyl methacrylate) and poly(propyl methacrylate) and overcome the skin's barrier function to measure oxygen in the capillary bed and interstitial fluid of the skin. The MNAs' tips are embedded with an oxygen-sensitive phosphorescent metalloporphyrin, where the oxygen partial pressure inversely correlates to changes in both emission intensity and phosphorescence lifetime of the in-house developed red emitting Pt-core porphyrin. It was demonstrated that the oxygen-sensing MNAs are sufficiently robust to puncture human skin via rupture of the stratum corneum, and that the MNAs can detect changes in oxygen partial pressure in skin within the physiologically relevant range (0-160 mmHg). Additionally, the MNAs can be combined with a wearable wireless optical readout system, making these oxygen-sensing MNAs a novel wearable and portable method for user-friendly monitoring of oxygen partial pressure in skin.


Assuntos
Metaloporfirinas , Pele , Humanos , Pressão Parcial , Oxigênio , Epiderme
2.
Adv Healthc Mater ; 11(10): e2101605, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35120400

RESUMO

Sensor-integrated wound dressings are emerging tools applicable to a wide variety of medical applications from emergency triage to at-home monitoring. Uncomfortable, unnecessary wound dressing changes may be avoided by providing quantitative insight into tissue characteristics related to wound healing such as tissue oxygenation, pH, and exudate/transudate volume. Here, a simple cost-effective methodology for quantifying oxygen and pH in a swellable hydrogel dressing using a single photograph is presented. The red and green luminescence of a novel dendritic polyamine Pt-porphyrin and fluorescein conjugate quantitatively responds to oxygen and pH, respectively, and enables robust sensing. The porphyrin conjugate, when combined with a four-arm star polyethylene glycol (PEG) amine polymer, rapidly crosslinks at room temperature with an N-hydroxysuccinimide (NHS)-PEG crosslinker to form a color-changing hydrogel dressing with tunable swelling capabilities applicable to a variety of wound environments. An inexpensive digital single-lens reflex (DSLR) camera modified with bandpass filters captures the hydrogel luminescence using simple macroscopic photography, and conversion to HSB colorspace allows for intensity-independent image analysis of the hydrogels' dual modality response. The hydrogel formulation exhibits a robust and validated visible red-orange-green "traffic light" spectrum in response to oxygen changes, regardless of swelling state, pH, or autofluorescence from skin, thereby enabling the clinician friendly naked-eye feedback.


Assuntos
Hidrogéis , Porfirinas , Bandagens , Luminescência , Oxigênio , Fotografação , Polietilenoglicóis
3.
Sci Rep ; 10(1): 9314, 2020 06 09.
Artigo em Inglês | MEDLINE | ID: mdl-32518260

RESUMO

Skin burns are a significant source of injury in both military and civilian sectors. They are especially problematic in low resource environments where non-fatal injuries can lead to high morbidity rates, prolonged hospitalization, and disability. These multifaceted wounds can be highly complex and must be quickly diagnosed and treated to achieve optimal outcomes. When the appropriate resources are available, the current gold standard for assessing skin burns is through tissue punch biopsies followed by histological analysis. Apart from being invasive, costly, and time-consuming, this method can suffer from heterogeneous sampling errors when interrogating large burn areas. Here we present a practical method for the early visualization of skin burn severity using a topically applied fluorescein-loaded liquid bandage and an unmodified commercial digital camera. Quantitative linear mixed effects models of color images from a four day porcine burn study demonstrate that colorimetric changes within the HSB colorspace can be used to estimate burn depth severity immediately after burning. The finding was verified using fluorescence imaging, tissue cross-sectioning, and histopathology. This low-cost, rapid, and non-invasive color analysis approach demonstrates the potential of dye-loaded liquid bandages as a method for skin burn assessment in settings such as emergency medicine triage and low resource environments.


Assuntos
Bandagens , Queimaduras/diagnóstico por imagem , Pele/diagnóstico por imagem , Animais , Queimaduras/diagnóstico , Queimaduras/patologia , Cor , Colorimetria/instrumentação , Colorimetria/métodos , Feminino , Fluoresceína , Corantes Fluorescentes , Imagem Óptica/métodos , Índice de Gravidade de Doença , Pele/lesões , Pele/patologia , Suínos
4.
Biomed Opt Express ; 11(12): 6989-7002, 2020 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-33408975

RESUMO

Wearable devices have found widespread applications in recent years as both medical devices as well as consumer electronics for sports and health tracking. A metric of health that is often overlooked in currently available technology is the direct measurement of molecular oxygen in living tissue, a key component in cellular energy production. Here, we report on the development of a wireless wearable prototype for transcutaneous oxygenation monitoring based on quantifying the oxygen-dependent phosphorescence of a metalloporphyrin embedded within a highly breathable oxygen sensing film. The device is completely self-contained, weighs under 30 grams, performs on-board signal analysis, and can communicate with computers or smartphones. The wearable measures tissue oxygenation at the skin surface by detecting the lifetime and intensity of phosphorescence, which undergoes quenching in the presence of oxygen. As well as being insensitive to motion artifacts, it offers robust and reliable measurements even in variable atmospheric conditions related to temperature and humidity. Preliminary in vivo testing in a porcine ischemia model shows that the wearable is highly sensitive to changes in tissue oxygenation in the physiological range upon inducing a decrease in limb perfusion.

5.
Photochem Photobiol ; 96(2): 373-379, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31869435

RESUMO

Quantification of tissue oxygen partial pressure (pO2 ) at the skin surface is crucial for diagnostic applications in burns, reconstructive surgeries, diabetic ulcers, etc. Further, current advances in wearable and communications technologies have widened the use of transcutaneous oxygen monitors (TCOM) for home care or even enhance athletic performance. For TCOM technology to find widespread use, devices must function reliably yet independently of changes in environmental conditions, humidity in particular. To this end, we have explored the incorporation of an oxygen-sensing metalloporphyrin within different host matrix materials of different compositions with the goal of overcoming the humidity sensitivity of previously explored oxygen-sensing materials. We developed a tetraethyl orthosilicate (TEOS)-based, highly breathable, oxygen-sensing metalloporphyrin polymer film which responds to changes in oxygenation independent of humidity.


Assuntos
Monitorização Transcutânea dos Gases Sanguíneos/métodos , Umidade , Oxigênio/análise , Dispositivos Eletrônicos Vestíveis , Humanos , Polímeros/química , Espectrofotometria Ultravioleta
6.
Biomicrofluidics ; 11(3): 034116, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28652886

RESUMO

A microfluidic device utilizing magnetically activated nickel (Ni) micropads has been developed for controlled localization of plasmonic core-shell magnetic nanoparticles, specifically for surface enhanced Raman spectroscopy (SERS) applications. Magnetic microfluidics allows for automated washing steps, provides a means for easy reagent packaging, allows for chip reusability, and can even be used to facilitate on-chip mixing and filtration towards full automation of biological sample processing and analysis. Milliliter volumes of gold-coated 175-nm silica encapsulated iron oxide nanoparticles were pumped into a microchannel and allowed to magnetically concentrate down into 7.5 nl volumes over nano-thick lithographically defined Ni micropads. This controlled aggregation of core-shell magnetic nanoparticles by an externally applied magnetic field not only enhances the SERS detection limit within the newly defined nanowells but also generates a more uniform (∼92%) distribution of the SERS signal when compared to random mechanical aggregation. The microfluidic flow rate and the direction and strength of the magnetic field determined the overall capture efficiency of the magneto-fluidic nanoparticle trapping platform. It was found that a 5 µl/min flow rate using an attractive magnetic field provided by 1 × 2 cm neodymium permanent magnets could capture over 90% of the magnetic core-shell nanoparticles across five Ni micropads. It was also observed that the intensity of the SERS signal for this setup was 10-fold higher than any other flow rate and magnetic field configurations tested. The magnetic concentration of the ferric core-shell nanoparticles causes the SERS signal to reach the steady state within 30 min can be reversed by simply removing the chip from the magnet housing and sonicating the retained particles from the outlet channel. Additionally, each magneto-fluidic can be reused without noticeable damage to the micropads up to three times.

7.
Anal Chem ; 86(23): 11614-9, 2014 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-25329684

RESUMO

Surface-enhanced Raman scattering (SERS) optical nanoprobes offer a number of advantages for ultrasensitive analyte detection. These functionalized colloidal nanoparticles are a multifunctional assay component. providing a platform for conjugation to spectral tags, stabilizing polymers, and biorecognition elements such as aptamers or antibodies. We demonstrate the design and characterization of a SERS-active nanoprobe and investigate the nanoparticles' biorecognition capabilities for use in a competitive binding assay. Specifically, the nanoprobe is designed for the quantification of bisphenol A (BPA) levels in the blood after human exposure to the toxin in food and beverage plastic packaging. The nanoprobes demonstrated specific affinity to a BPA aptamer with a dissociation constant Kd of 54 nM, and provided a dose-dependent SERS spectra with a limit of detection of 3 nM. Our conjugation approach shows the versatility of colloidal nanoparticles in assay development, acting as detectable spectral tagging elements and biologically active ligands concurrently.


Assuntos
Aptâmeros de Nucleotídeos/química , Aptâmeros de Nucleotídeos/síntese química , Compostos Benzidrílicos/sangue , Desenho de Fármacos , Nanopartículas/química , Fenóis/sangue , Análise Espectral Raman , Humanos , Estrutura Molecular , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...