Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Anesth ; 37: 21-24, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28235522

RESUMO

STUDY OBJECTIVE: This randomized controlled trial was designed to evaluate the efficacy of additional information from preprocedure ultrasound examination to aid anesthesiology trainees performing spinal anesthesia for obstetric patients. DESIGN: Trainee residents were randomly allocated to landmark technique and anatomy demonstration via ultrasound examination or landmark technique only for spinal anesthetic placement. SETTING: Obstetric delivery suite. PATIENTS: Eighty healthy obstetric patients undergoing elective cesarean delivery. INTERVENTION: Ultrasound examination prior to spinal anesthetic placement. MEASUREMENTS: The primary outcome was the number of attempts for the spinal anesthetic. Secondary outcomes included placement duration; block height; and the incidence of need for staff intervention, paresthesia, and bloody tap. Subjective ease of placement was rated on a 100-mm visual analog scale. MAIN RESULTS: Baseline demographic data were similar between the patient groups. The median number of attempts with preprocedure ultrasound and landmark was 3 (interquartile range, 2-7). This was not significantly different from the number of attempts with landmark technique only of 3 (1-60) (P=.69). The median duration of spinal placement with ultrasound and landmark was 92 (51-140) seconds vs 75 (53-126) seconds with landmark only (P=.57). There was no statistical difference between the groups in spinal placement duration, need for staff intervention, paresthesia, bloody tap, lumbar interspace, or block height. There was no difference in subjective ease of spinal placement by the resident. CONCLUSIONS: In this study of junior anesthesia trainees performing obstetrical spinal anesthesia with preprocedure ultrasound and landmark technique or landmark technique only, no significant difference was observed in the number of attempts, duration of spinal placement, subjective ease of spinal placement, or any other measured secondary outcome.


Assuntos
Anestesia Obstétrica/métodos , Raquianestesia/métodos , Anestesiologistas/educação , Cateterismo/métodos , Internato e Residência , Bloqueio Nervoso/métodos , Cuidados Pré-Operatórios/métodos , Adulto , Anestesia Obstétrica/efeitos adversos , Raquianestesia/efeitos adversos , Cesárea/efeitos adversos , Procedimentos Cirúrgicos Eletivos/efeitos adversos , Feminino , Humanos , Masculino , Bloqueio Nervoso/efeitos adversos , Gravidez , Estudos Prospectivos , Ultrassonografia de Intervenção
2.
Anesth Analg ; 117(3): 677-685, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23921652

RESUMO

BACKGROUND: A single dose of epidural morphine is effective in reducing pain after cesarean delivery but is associated with adverse effects. In this study, we sought to establish whether half the traditional dose of epidural morphine, when administered as part of a multimodal analgesia regimen after cesarean delivery, was associated with noninferior analgesia and fewer adverse effects. METHODS: Ninety term parturients undergoing cesarean delivery under epidural anesthesia were enrolled in this randomized, double-blinded, noninferiority study. Patients were randomly allocated to receive either 3 mg epidural morphine or, half this dose, 1.5 mg epidural morphine. In addition, subjects received regular systemic ketorolac and acetaminophen. Rescue analgesia (oral oxycodone) was administered for breakthrough pain. The primary outcome was the difference between groups in total opioid consumption (measured in median IV morphine equivalents) within the first 24 hours. A prespecified noninferiority margin of 3.33 mg was used. Secondary outcomes included total opioid consumption from 24 to 48 hours, numerical rating scale pain scores, time to first request for analgesics, overall pain relief, maternal satisfaction, quality of recovery, and adverse effects. RESULTS: Data were analyzed for 87 participants. Noninferiority was demonstrated as the difference in median 24-hour opioid consumption between the 1.5 mg epidural morphine (EM) and 3 mg EM groups was 0 mg (1-sided 95% confidence interval [CI], 2.5 mg), which was less than the prespecified noninferiority margin of 3.33 mg. No significant differences were found between groups in the median 24- to 48-hour opioid consumption or the median total opioid consumption within 48 hours. Pain scores, overall pain relief, and satisfaction at 24 and 48 hours were not significantly different between groups. The 1.5 mg EM group had a lower incidence of moderate and severe pruritus at 6 and 12 hours (relative risk [RR] 0.44, 95% CI, 0.2-0.9 and RR 0.41, 95% CI, 0.2-0.8, respectively) and had less nausea and vomiting at 6 hours (RR 0.22, 95% CI, 0.05-0.9). There was no difference in average pain scores at 12 weeks between the 2 groups. CONCLUSION: When used as part of a multimodal analgesia regimen, 1.5 mg epidural morphine provided noninferior postcesarean analgesia and caused fewer adverse effects compared with 3 mg epidural morphine.


Assuntos
Analgesia Obstétrica/métodos , Analgésicos Opioides/uso terapêutico , Cesárea , Morfina/uso terapêutico , Dor Pós-Operatória/tratamento farmacológico , Adolescente , Adulto , Analgésicos Opioides/administração & dosagem , Analgésicos Opioides/efeitos adversos , Anti-Inflamatórios não Esteroides/uso terapêutico , Relação Dose-Resposta a Droga , Método Duplo-Cego , Feminino , Humanos , Cetorolaco/uso terapêutico , Morfina/administração & dosagem , Morfina/efeitos adversos , Náusea/induzido quimicamente , Medição da Dor , Satisfação do Paciente , Gravidez , Prurido/induzido quimicamente , Resultado do Tratamento , Adulto Jovem
3.
J Immunol Methods ; 274(1-2): 233-44, 2003 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-12609549

RESUMO

Phage display technology (PDT) is a powerful method for isolating functional gene products such as antigen-specific monoclonal antibodies (mAbs). To improve the effectiveness of PDT, we sought to optimize display of Fab-g3p (antibody fragment fused with viral gene 3 protein) on phagemid virions and to optimize the yield of such phage. To do so, we constructed a novel helper phage, Phaberge, having a conditional deficiency in g3p production. Unlike most other published g3p-deficient helper phage, Phaberge is produced at high levels, 10(11) PFU/ml. As compared to g3p-sufficient helper phage, Phaberge caused a 5-20-fold increase in display level. Another novel feature is that Phaberge only packages insert-containing, not insert-less, phagemid into infectious virions. This should prove useful in preserving quality of phagemid libraries during propagation. In addition, other parameters were also found to affect production of phagemid virions. In particular, the choice of bacterial host cell, phagemid construct and growth temperature had a substantial impact on display levels, but generally no effect on number of phagemid virions produced. In short, we have established a set of parameters that improve production and quality of phagemid virions which we expect to facilitate the isolation of mAbs or other gene products by PDT.


Assuntos
Bacteriófagos/genética , Vetores Genéticos , Fragmentos Fab das Imunoglobulinas/genética , Biblioteca de Peptídeos , Vírus/genética , Anticorpos Monoclonais/genética , Escherichia coli/genética , Deleção de Genes , Genes Virais , Humanos , Proteínas Recombinantes de Fusão/genética , Vírion/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...