Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Eur J Neurol ; 31(7): e16290, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38556758

RESUMO

BACKGROUND AND PURPOSE: Antiganglioside antibodies (AGAs) might be involved in the etiopathogenesis of many neurological diseases, such as Miller-Fisher syndrome (MFS) and Guillain-Barré syndrome (GBS). Available comprehensive reference data regarding AGA positivity rates and cross-responsiveness among AGAs (where one line immunoblot is positive for ≥1 AGA) during routine clinical care are scant. METHODS: In this 10-year monocentric retrospective study, 3560 immunoglobulin (Ig) G and IgM line blots (GA Generic Assays' Anti-Ganglioside Dot kit) obtained using cerebrospinal fluid (CSF) and serum samples from 1342 patients were analyzed for AGA positivity in terms of 14 diagnosis categories and AGA cross-responsiveness. RESULTS: Of all 3560 line blots 158 (4.4%) and of all CSF samples 0.4% (4/924) CSF line blots were AGA positive. For serum IgG, blots with positivity rates higher than the standard deviation of 15.6% were associated with MFS (GD3, GD1a, GT1a and GQ1b) and acute motor axonal neuropathy (AMAN) (GM1, GD1a and GT1a). For serum IgM, blots with positivity rates higher than the standard deviation of 8.1% were associated with AMAN (GM2, GT1a and GQ1b), MFS (GM1, GT1a and GQ1b), multifocal motor neuropathy (MMN) (GM1, GM2 and GQ1b) and chronic inflammatory demyelinating polyneuropathy (CIDP) (GM1). Cross-responsiveness was observed in 39.6% of all positive serum AGA. CONCLUSIONS: Testing for AGAs during routine clinical care rarely led to positive findings, both in serum and even less in CSF, except for the diagnoses AMAN, MFS, MMN and CIDP. Nonspecific findings found as cross-responsiveness between different AGA samples occur frequently, impacting the positivity of most AGA subtypes.


Assuntos
Autoanticorpos , Gangliosídeos , Humanos , Estudos Retrospectivos , Gangliosídeos/imunologia , Autoanticorpos/sangue , Autoanticorpos/líquido cefalorraquidiano , Feminino , Masculino , Pessoa de Meia-Idade , Imunoglobulina G/sangue , Imunoglobulina G/líquido cefalorraquidiano , Síndrome de Miller Fisher/sangue , Síndrome de Miller Fisher/diagnóstico , Síndrome de Miller Fisher/imunologia , Síndrome de Miller Fisher/líquido cefalorraquidiano , Imunoglobulina M/sangue , Imunoglobulina M/líquido cefalorraquidiano , Adulto , Síndrome de Guillain-Barré/sangue , Síndrome de Guillain-Barré/líquido cefalorraquidiano , Síndrome de Guillain-Barré/diagnóstico , Síndrome de Guillain-Barré/imunologia , Idoso
2.
Pain Pract ; 24(3): 502-513, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38057944

RESUMO

OBJECTIVE: The combined use of spinal cord stimulation (SCS) and muscle stimulation, in the treatment of chronic pain, using the same probe, could improve the clinical results. However, this technique has not been established as yet. It was our hypothesis that it is possible to generate muscle stimulation by using low frequencies with SCS electrodes and use it to additionally treat chronic back pain. METHODS: We generated muscle stimulation in patients with previously implanted SCS electrodes, for the treatment of lower back pain, by using low frequencies (2, 4, 6, and 8 Hz) and different contact combinations of the electrodes. The results were evaluated by using visual inspection (videos), haptic control, surface electromyography (EMG), and sonographic recordings. RESULTS: This pilot study (17 patients, seven females, age 36-87 years, 11 percutaneous paddle leads, and 6 octrodes) was performed at the Neurosurgical Department of the University of Tuebingen. The most preferred frequencies were 6 Hz (45.5% of percutaneous paddle leads) and 8 Hz (50% of octrodes) at contacts 3&4 or 5&6. The preference of frequencies differed significantly among genders (p = 0.023). Simultaneous EMG and ultrasonic recordings demonstrated the generation of muscle potentials and the stimulation of deeper muscle groups. CONCLUSION: In this study, it has been shown that with low-frequency SCS stimulation, pleasant and pain-relieving muscle contractions of the lower and upper back can also be generated. This combined method has been coined by us as "MuscleSCS" technique. Clinical trials are necessary to establish the value of this combined technique and its subtypes.


Assuntos
Dor Lombar , Estimulação da Medula Espinal , Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Dor Lombar/terapia , Estimulação da Medula Espinal/métodos , Projetos Piloto , Dor nas Costas/terapia , Eletrodos Implantados , Medula Espinal , Resultado do Tratamento
3.
Sci Rep ; 13(1): 22157, 2023 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-38092937

RESUMO

Optically pumped magnetometers (OPM) are quantum sensors that offer new possibilities to measure biomagnetic signals. Compared to the current standard surface electromyography (EMG), in magnetomyography (MMG), OPM sensors offer the advantage of contactless measurements of muscle activity. However, little is known about the relative performance of OPM-MMG and EMG, e.g. in their ability to detect and classify finger movements. To address this in a proof-of-principle study, we recorded simultaneous OPM-MMG and EMG of finger flexor muscles for the discrimination of individual finger movements on a single human participant. Using a deep learning model for movement classification, we found that both sensor modalities were able to discriminate finger movements with above 89% accuracy. Furthermore, model predictions for the two sensor modalities showed high agreement in movement detection (85% agreement; Cohen's kappa: 0.45). Our findings show that OPM sensors can be employed for contactless discrimination of finger movements and incentivize future applications of OPM in magnetomyography.


Assuntos
Dedos , Músculo Esquelético , Humanos , Dedos/fisiologia , Eletromiografia , Músculo Esquelético/fisiologia , Movimento/fisiologia , Magnetoencefalografia
4.
Sci Rep ; 13(1): 20062, 2023 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-37974024

RESUMO

Aging leads to a decline in muscle mass and force-generating capacity. Ultrasound shear wave elastography (SWE) is a non-invasive method to capture age-related muscular adaptation. This study assessed biceps brachii muscle (BB) mechanics, hypothesizing that shear elastic modulus reflects (i) passive muscle force increase imposed by length change, (ii) activation-dependent mechanical changes, and (iii) differences between older and younger individuals. Fourteen healthy volunteers aged 60-80 participated. Shear elastic modulus, surface electromyography, and elbow torque were measured at five elbow positions in passive and active states. Data collected from young adults aged 20-40 were compared. The BB passive shear elastic modulus increased from flexion to extension, with the older group exhibiting up to 52.58% higher values. Maximum elbow flexion torque decreased in extended positions, with the older group 23.67% weaker. Significant effects of elbow angle, activity level, and age on total and active shear elastic modulus were found during submaximal contractions. The older group had 20.25% lower active shear elastic modulus at 25% maximum voluntary contraction. SWE effectively quantified passive and activation-dependent BB mechanics, detecting age-related alterations at rest and during low-level activities. These findings suggest shear elastic modulus as a promising biomarker for identifying altered muscle mechanics in aging.


Assuntos
Técnicas de Imagem por Elasticidade , Articulação do Cotovelo , Adulto Jovem , Humanos , Técnicas de Imagem por Elasticidade/métodos , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiologia , Ultrassonografia , Cotovelo/diagnóstico por imagem , Cotovelo/fisiologia , Articulação do Cotovelo/diagnóstico por imagem , Articulação do Cotovelo/fisiologia , Módulo de Elasticidade/fisiologia
5.
J Clin Med ; 12(13)2023 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-37445529

RESUMO

BACKGROUND: enamel demineralization is a common side effect of orthodontic therapy with fixed braces. The aim of the present in vitro study was to compare a conventional adhesive system and a modern adhesive system (APC Flash-Free [FF] technology) with regard to the demineralization of enamel by Streptococcus sobrinus (S. sobrinus). METHODS: this in vitro study included premolar teeth and compared APC FF adhesive brackets (Group A, n = 15) with conventional adhesive brackets (Group B, n = 15) from the same company. Specimens were incubated with a positive control group (PCG, n = 5) and a negative control group (NCG, n = 5) in an S. sobrinus suspension for three weeks. To evaluate the grade of enamel demineralization, the samples were analyzed using a polarizing microscope. RESULTS: the test specimens of group B with conventionally bonded bracket adhesive showed significantly greater (+10.8 µm) demineralization with regard to the penetration depth of the demineralization than the PCG (p = 0.012). Thus, there was a difference from group A with the new bracket adhesive of the FF brackets (+7.29 µm). Significantly, demineralization was more pronounced cervically than coronally in both groups, and it occurred cervically more frequently than grade 3 demineralization (p = 0.001). CONCLUSIONS: it seems plausible that new orthodontic bracket adhesives and the modern FF adhesive system positively contribute to the reduction in enamel demineralization during orthodontic treatment.

6.
Neuroimage Clin ; 39: 103474, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37441820

RESUMO

BACKGROUND AND OBJECTIVES: Genetic generalized epilepsy (GGE) is the most common form of generalized epilepsy. Although individual patients with GGE typically present without structural alterations, group differences have been demonstrated in GGE and some GGE subtypes like juvenile myoclonic epilepsy (GGE-JME). Previous studies usually involved only small cohorts from single centers and therefore could not assess imaging markers of multiple GGE subtypes. METHODS: We performed a diffusion MRI mega-analysis in 192 participants consisting of 126 controls and 66 patients with GGE from four different cohorts and two different epilepsy centers. We applied whole-brain multi-site harmonization and analyzed fractional anisotropy (FA), as well as mean, radial and axial diffusivity (MD/RD/AD) to assess differences between controls, patients with GGE and the common GGE subtypes, i.e. GGE with generalized tonic-clonic seizures only (GGE-GTCS), GGE-JME and absence epilepsy (GGE-AE). We also analyzed relationships with patients' response to anti-seizure-medication (ASM). RESULTS: Relative to controls, we identified decreased anisotropy and increased RD in patients with GGE. We found no significant effects of disease duration, age of onset or seizure frequency on diffusion metrics. Patients with JME had increased MD and RD when compared to controls, while patients with GGE-GTCS showed decreased MD/AD when compared to controls. Compared to patients with GGE-AE, patients with GGE-GTCS had lower AD/MD. Compared to patients with GGE-GTCS, patients with GGE-JME had higher MD/RD and AD. Moreover, we found lower FA in patients with refractory when compared to patients with non-refractory GGE in the right cortico-spinal tract, but no significant differences in patients with active versus controlled epilepsy. DISCUSSION: We provide evidence that clinically defined GGE as a whole and GGE-subtypes harbor marked microstructural differences detectable with diffusion MRI. Moreover, we found an association between microstructural changes and treatment resistance. Our findings have important implications for future full-resolution multi-site studies when assessing GGE, its subtypes and ASM refractoriness.


Assuntos
Epilepsia Tipo Ausência , Epilepsia Generalizada , Epilepsia Mioclônica Juvenil , Humanos , Epilepsia Generalizada/diagnóstico por imagem , Epilepsia Generalizada/genética , Encéfalo/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética
7.
Materials (Basel) ; 16(11)2023 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-37297118

RESUMO

The design of and materials for prosthodontic abutments and posts have significant influences on the fracture resistance of restored teeth. This in vitro study compared the fracture strength and marginal quality of full-ceramic crowns as a function of the inserted root posts via simulation of a five-year period of use. Test specimens were prepared from 60 extracted maxillary incisors using titanium L9 (A), glass-fiber L9 (B), and glass-fiber L6 (C) root posts. The circular marginal gap behavior, linear loading capacity, and material fatigue after artificial aging were investigated. The marginal gap behavior and material fatigue were analyzed using electron microscopy. The linear loading capacity of the specimens was investigated using the Zwick Z005 universal testing machine. None of the tested root post materials showed statistically significant differences in marginal width values (p = 0.921), except in the case of marginal gap location. For Group A, there was a statistically significant difference from the labial to the distal (p = 0.012), mesial (p = 0.000), and palatinal (p = 0.005). Similarly, Group B showed a statistically significant difference from the labial to the distal (p = 0.003), mesial (p = 0.000), and palatinal (p = 0.003). Group C showed a statistically significant difference from the labial to the distal (p = 0.001) and mesial (p = 0.009). Linear load capacity reached mean values of 455.8-537.7 N, and micro-cracks occurred after artificial aging, predominantly in Groups B and C. Through the chosen experimental design, it was shown that the root post material and root post length had no influence on the fracture strength of the test teeth before or after artificial aging. However, the marginal gap location depends on the root post material and its length, which is wider mesially and distally and also tends to be greater palatinally than labially.

8.
Front Neurosci ; 17: 1154572, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37274205

RESUMO

Neuromuscular diseases are a prevalent cause of prolonged and severe suffering for patients, and with the global population aging, it is increasingly becoming a pressing concern. To assess muscle activity in NMDs, clinicians and researchers typically use electromyography (EMG), which can be either non-invasive using surface EMG, or invasive through needle EMG. Surface EMG signals have a low spatial resolution, and while the needle EMG provides a higher resolution, it can be painful for the patients, with an additional risk of infection. The pain associated with the needle EMG can pose a risk for certain patient groups, such as children. For example, children with spinal muscular atrophy (type of NMD) require regular monitoring of treatment efficacy through needle EMG; however, due to the pain caused by the procedure, clinicians often rely on a clinical assessment rather than needle EMG. Magnetomyography (MMG), the magnetic counterpart of the EMG, measures muscle activity non-invasively using magnetic signals. With super-resolution capabilities, MMG has the potential to improve spatial resolution and, in the meantime, address the limitations of EMG. This article discusses the challenges in developing magnetic sensors for MMG, including sensor design and technology advancements that allow for more specific recordings, targeting of individual motor units, and reduction of magnetic noise. In addition, we cover the motor unit behavior and activation pattern, an overview of magnetic sensing technologies, and evaluations of wearable, non-invasive magnetic sensors for MMG.

9.
Clin Neurophysiol Pract ; 8: 58-64, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37033684

RESUMO

Objective: Emergency diagnostics, such as acquisition of an electroencephalogram (EEG), are of great diagnostic importance, but there is often a lack of experienced personnel. Wet active electrode sponge-based electroencephalogram (sp-EEG) systems can be applied rapidly and by inexperienced personnel. This makes them an attractive alternative to routine EEG (r-EEG) systems in these settings. Here, we examined the feasibility and signal quality of sp-EEG compared to r-EEG. Methods: In this case-control, single-blind, non-randomized study, EEG recordings using a sp- and a r-EEG system were performed in 18 individuals with a variety of epileptiform discharges and 11 healthy control subjects. The time was stopped until all electrodes in both systems displayed adequate skin-electrode impedances. The resulting 58 EEGs were visually inspected by 7 experienced, blinded neurologists. Raters were asked to score physiological and pathological graphoelements, and to distinguish between the different systems by visual inspection of the EEGs. Results: Time to signal acquisition for sp-EEG was significantly faster (4.8 min (SD 2.01) vs. r-EEG 13.3 min (SD 2.72), p < 0.001). All physiological and pathological graphoelements of all 58 EEGs could be identified. Raters were unable to distinguish between sp-EEG or r-EEG based on visual inspection of the EEGs alone. Conclusions: Sp-EEG represents a feasible alternative to r-EEG in emergency diagnostics or resource-limited settings. Significance: Given shortage of trained personnel or resources, the easy implementation and comparable quality of a novel sp-EEG system may increase general availability of EEG and thus improve patient care.

10.
Sci Data ; 10(1): 211, 2023 04 14.
Artigo em Inglês | MEDLINE | ID: mdl-37059732

RESUMO

Image templates are a common tool for neuroscience research. Often, they are used for spatial normalization of magnetic resonance imaging (MRI) data, which is a necessary procedure for analyzing brain morphology and function via voxel-based analysis. This allows the researcher to reduce individual shape differences across images and make inferences across multiple subjects. Many templates have a small field-of-view typically focussed on the brain, limiting the use for applications requiring detailed information about other extra-cranial structures in the head and neck area. However, there are several applications where such information is important, for example source reconstruction of electroencephalography (EEG) and/or magnetoencephalography (MEG). We have constructed a new template based on 225 T1w and FLAIR images with a big field-of-view that can serve both as target for across subject spatial normalization as well as a basis to build high-resolution head models. This template is based on and iteratively re-registered to the MNI152 space to provide maximal compatibility with the most commonly used brain MRI template.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Humanos , Encéfalo/anatomia & histologia , Mapeamento Encefálico/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Magnetoencefalografia/métodos , Crânio
11.
Diagnostics (Basel) ; 13(6)2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36980415

RESUMO

Myasthenia gravis (MG) is often accompanied with muscle weakness; however, little is known about mechanical adaptions of the affected muscles. As the latter can be assessed using ultrasound shear wave elastography (SWE), this study characterizes the biceps brachii muscle of 11 patients with MG and compares them with that of 14 healthy volunteers. Simultaneous SWE, elbow torque and surface electromyography measurements were performed during rest, maximal voluntary contraction (MVC) and submaximal isometric contractions (up to 25%, 50% and 75% MVC) at different elbow angles from flexion to extension. We found that, with increasing elbow angle, maximum elbow torque decreased (p < 0.001), whereas muscle stiffness increased during rest (p = 0.001), MVC (p = 0.004) and submaximal contractions (p < 0.001). Muscle stiffness increased with increasing contraction intensities during submaximal contractions (p < 0.001). In comparison to the healthy cohort, muscle stiffness of MG patients was 2.1 times higher at rest (p < 0.001) but 8.93% lower in active state (75% MVC, p = 0.044). We conclude that (i) increased muscle stiffness shown by SWE during rest might be an indicator of MG, (ii) SWE reflects muscle weakness and (iii) SWE can be used to characterize MG muscle.

12.
Stem Cell Res ; 67: 103028, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36652844

RESUMO

The STX1B gene encodes the presynaptic protein syntaxin-1B, which plays a major role in regulating fusion of synaptic vesicles. Mutations in STX1B are known to cause epilepsy syndromes, such as genetic epilepsies with febrile seizures plus (GEFS+). Here, we reprogrammed skin fibroblasts from a female patient affected by GEFS+ to human induced pluripotent stem cells (iPSCs). The patient carries an InDel mutation (c.133_134insGGATGTGCATTG; p.Lys45delinsArgMetCysIleGlu and c.135_136AC > GA; p.Leu46Met), located in the regulatory Habc-domain of STX1B. Successful reprogramming of cells was confirmed by a normal karyotype, expression of several pluripotency markers and the potential to differentiate into all three germ layers.


Assuntos
Epilepsia , Células-Tronco Pluripotentes Induzidas , Humanos , Feminino , Células-Tronco Pluripotentes Induzidas/metabolismo , Mutação , Epilepsia/genética , Mutação INDEL , Fibroblastos , Diferenciação Celular , Sintaxina 1/genética , Sintaxina 1/metabolismo
13.
Diagnostics (Basel) ; 13(2)2023 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-36673022

RESUMO

Rigidity in Parkinson's disease (PD) is assessed by clinical scales, mostly the Unified Parkinson's Disease Rating Scale of the Movement Disorders Society (MDS-UPDRS). While the MDS-UPDRS-III ranges on an integer from 0 to 4, we investigated whether muscle ultrasound shear wave elastography (SWE) offers a refined assessment. Ten PD patients (five treated with deep brain stimulation (DBS) and levodopa, five with levodopa only) and ten healthy controls were included. Over a period of 80 min, both the SWE value and the item 22b-c of the MDS-UPDRS-III were measured at 5 min intervals. The measurements were performed bilaterally at the biceps brachii muscle (BB) and flexor digitorum profundus muscle in flexion and passive extension. Rigidity was modified and tracked under various therapeutic conditions (with and without medication/DBS). The feasibility of SWE for objective quantification was evaluated by correlation with the UPDRS-III: considering all positions and muscles, there was already a weak correlation (r = 0.01, p < 0.001)­in a targeted analysis, the BB in passive extension showed a markedly higher correlation (r = 0.494, p < 0.001). The application of dopaminergic medication and DBS resulted in statistically significant short-term changes in both clinical rigidity and SWE measurements in the BB (p < 0.001). We conclude that rigidity is reflected in the SWE measurements, indicating that SWE is a potential non-invasive quantitative assessment tool for PD.

14.
Diagnostics (Basel) ; 13(2)2023 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-36673086

RESUMO

Ultrasound shear wave elastography (SWE) is an emerging modality for the estimation of stiffness, but it has not been studied in relation to common disorders with altered stiffness, such as bruxism, which affects almost one-third of adults. Because this condition could lead to an increased stiffness of masticatory muscles, we investigated SWE in bruxism according to a proof-of-principle and feasibility study with 10 patients with known bruxism and an age- and gender-matched control group. SWE of the left and right masseter muscles was estimated under three conditions: relaxed jaw, 50% of the subjective maximal bite force, and maximal jaw opening. Rejecting the null hypothesis, SWE was significantly increased during relaxed jaw (bruxism 1.92 m/s ± 0.44; controls 1.66 m/s ± 0.24), whereas for maximal mouth opening, the result was vice versa increased with 2.89 m/s ± 0.93 for bruxism patients compared with 3.53 m/s ± 0.95 in the healthy control, which could be due to limited jaw movement in chronic bruxism patients (bruxism 4.46 m/s ± 1.17; controls 5.23 m/s ± 0.43). We show that SWE in bruxism is feasible and could be of potential use for diagnostics and monitoring, though we also highlight important limitations and necessary methodological considerations for future studies.

15.
J Mech Behav Biomed Mater ; 137: 105543, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36371993

RESUMO

Mechanical characterization of individual muscles in their in vivo environment is not well studied. Shear wave elastography (SWE) as a non-invasive technique was shown to be promising in quantifying the local mechanical properties of skeletal muscles. This study aimed to investigate the mechanics of the biceps brachii muscle (BB) derived from SWE in relation to elbow joint position and contraction intensity during isometric contraction. 14 healthy, young subjects participated in the study and five different joint positions (60°-180° elbow angle) were investigated. Shear elastic modulus and surface electromyography (sEMG) of the BB and elbow torque were measured simultaneously, both in passive (i.e., resting) and active states during slow, sub-maximal isometric ramp contractions up to 25%, 50%, and 75% of the maximum voluntary contraction. At passive state, the shear elastic modulus of the BB increased with increasing elbow angle (p < 0.001). Maximum elbow flexion torque was produced at 60° and it decreased with increasing elbow angle (p = 0.001). During sub-maximal contractions, both elbow angle (p < 0.001) and contraction intensity (p < 0.001) had significant effects on the shear elastic modulus but only contraction intensity (p < 0.001) affected sEMG amplitude of the BB. Although torque was decreased at extended elbow positions (150°, 180°), higher active shear elastic modulus of BB muscle was found compared to flexed positions (60°, 90°). Linear regression of the BB sEMG amplitude over elbow torque showed good agreement for all joint positions (R2 between 0.69 and 0.89) while the linear agreement between shear elastic modulus of BB and elbow torque differed between flexed (R2 = 0.70 at 60° and R2 = 0.79 at 90°) and extended positions (with the lowest R2 = 0.57 at 150°). We conclude that using SWE, we can detect length-dependent mechanical changes of BB both in passive and active states. More importantly, SWE can be used to characterize active muscle properties in vivo. The present findings have critical importance for developing muscle stiffness as a measure of individual muscle force to validate muscle models and using SWE in clinical diagnostics.


Assuntos
Técnicas de Imagem por Elasticidade , Humanos , Técnicas de Imagem por Elasticidade/métodos , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiologia , Contração Isométrica/fisiologia , Cotovelo/fisiologia , Eletromiografia , Contração Muscular/fisiologia
16.
Front Neurosci ; 16: 1010242, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36523432

RESUMO

Optically pumped magnetometers (OPM) are quantum sensors that enable the contactless, non-invasive measurement of biomagnetic muscle signals, i.e., magnetomyography (MMG). Due to the contactless recording, OPM-MMG might be preferable to standard electromyography (EMG) for patients with neuromuscular diseases, particularly when repetitive recordings for diagnostic and therapeutic monitoring are mandatory. OPM-MMG studies have focused on recording physiological muscle activity in healthy individuals, whereas research on neuromuscular patients with pathological altered muscle activity is non-existent. Here, we report a proof-of-principle study on the application of OPM-MMG in patients with neuromuscular diseases. Specifically, we compare the muscular activity during maximal isometric contraction of the left rectus femoris muscle in three neuromuscular patients with severe (Transthyretin Amyloidosis in combination with Pompe's disease), mild (Charcot-Marie-Tooth disease, type 2), and without neurogenic, but myogenic, damage (Myotonia Congenita). Seven healthy young participants served as the control group. As expected, and confirmed by using simultaneous surface electromyography (sEMG), a time-series analysis revealed a dispersed interference pattern during maximal contraction with high amplitudes. Furthermore, both patients with neurogenic damage (ATTR and CMT2) showed a reduced variability of the MMG signal, quantified as the signal standard deviation of the main component of the frequency spectrum, highlighting the reduced possibility of motor unit recruitment due to the loss of motor neurons. Our results show that recording pathologically altered voluntary muscle activity with OPM-MMG is possible, paving the way for the potential use of OPM-MMG in larger studies to explore the potential benefits in clinical neurophysiology.

17.
Epilepsia ; 63(7): 1643-1657, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35416282

RESUMO

OBJECTIVE: Genetic generalized epilepsy (GGE) is characterized by aberrant neuronal dynamics and subtle structural alterations. We evaluated whether a combination of magnetic and electrical neuronal signals and cortical thickness would provide complementary information about network pathology in GGE. We also investigated whether these imaging phenotypes were present in healthy siblings of the patients to test for genetic influence. METHODS: In this cross-sectional study, we analyzed 5 min of resting state data acquired using electroencephalography (EEG) and magnetoencephalography (MEG) in patients, their siblings, and controls, matched for age and sex. We computed source-reconstructed power and connectivity in six frequency bands (1-40 Hz) and cortical thickness (derived from magnetic resonance imaging). Group differences were assessed using permutation analysis of linear models for each modality separately and jointly for all modalities using a nonparametric combination. RESULTS: Patients with GGE (n = 23) had higher power than controls (n = 35) in all frequencies, with a more posterior focus in MEG than EEG. Connectivity was also increased, particularly in frontotemporal and central regions in theta (strongest in EEG) and low beta frequencies (strongest in MEG), which was eminent in the joint EEG/MEG analysis. EEG showed weaker connectivity differences in higher frequencies, possibly related to drug effects. The inclusion of cortical thickness reinforced group differences in connectivity and power. Siblings (n = 18) had functional and structural patterns intermediate between those of patients and controls. SIGNIFICANCE: EEG detected increased connectivity and power in GGE similar to MEG, but with different spectral sensitivity, highlighting the importance of theta and beta oscillations. Cortical thickness reductions in GGE corresponded to functional imaging patterns. Our multimodal approach extends the understanding of the resting state in GGE and points to genetic underpinnings of the imaging markers studied, providing new insights into the causes and consequences of epilepsy.


Assuntos
Mapeamento Encefálico , Epilepsia Generalizada , Encéfalo , Mapeamento Encefálico/métodos , Estudos Transversais , Eletroencefalografia/métodos , Epilepsia Generalizada/diagnóstico por imagem , Epilepsia Generalizada/genética , Humanos , Imageamento por Ressonância Magnética/métodos , Magnetoencefalografia/métodos , Fenótipo , Irmãos
19.
Diagnostics (Basel) ; 12(2)2022 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-35204451

RESUMO

Ultrasound shear wave elastography (SWE) is an increasingly used imaging modality that expands clinical ultrasound by measuring the elasticity of various tissues, such as the altered elasticity of tumors. Peripheral nerve tumors are rare, have been well-characterized by B-mode-ultrasound, but have not yet been investigated with SWE. Given the lack of studies, a first step would be to investigate homogeneous peripheral nerve tumors (PNTs), histologically neurofibromas or schwannomas, which can occur in multiple in neurofibromatosis type 1 and 2 (NF1 and 2), respectively. Hence, we measured shear wave velocity (SWV) in 30 PNTs of 11 patients with NF1 within the median nerve. The SWV in PNTs ranged between 2.8 ± 0.8 m/s and correlated with their width and approximate volume but not with their length or height. Furthermore, we determined the extent to which PNTs alter the SWV of the median nerve for three positions of the wrist joint: neutral (zero-degree), individual maximal flexion and maximal extension. Here, SWV was decreased in NF1 patients compared to age- and sex-matched controls (p = 0.029) during maximal wrist extension. We speculate that the presence of PNTs may have a biomechanical impact on peripheral nerves which has not been demonstrated yet.

20.
Palliat Support Care ; 20(6): 779-784, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36942581

RESUMO

OBJECTIVE: The prevalence and effects of delirium in very old individuals aged ≥80 years have not yet been systematically evaluated. Therefore, this large single-center study of the one-year prevalence of delirium in 3,076 patients in 27 medical departments of the University Hospital of Zurich was conducted. METHODS: Patient scores on the Delirium Observation Screening scale, Intensive Care Delirium Screening Checklist, Diagnostic and Statistical Manual, 5th edition, and electronic Patient Assessment-Acute Care (nursing tool) resulted in the inclusion of 3,076 individuals in 27 departments. The prevalence rates were determined by simple logistic regressions, odds ratios (ORs), and confidence intervals. RESULTS: Of the 3,076 patients, 1,285 (41.8%) developed delirium. The prevalence rates in the 27 departments ranged from 15% in rheumatology (OR = 0.30) to 73% in intensive care (OR = 5.25). Delirious patients were more likely to have been admitted from long-term care facilities (OR = 2.26) or because of emergencies (OR = 2.24). The length of their hospital stay was twice as long as that for other patients. Some died before discharge (OR = 24.88), and others were discharged to nursing homes (OR = 2.96) or assisted living facilities (OR = 2.2). CONCLUSION: This is the largest study to date regarding the prevalence of delirium in patients aged ≥80 years and the medical characteristics of these patients. Almost two out of five patients developed delirium, with a high risk of loss of independence and mortality.


Assuntos
Delírio , Humanos , Estudos Prospectivos , Prevalência , Delírio/diagnóstico , Cuidados Críticos , Casas de Saúde , Unidades de Terapia Intensiva , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...