Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Laterality ; 25(5): 513-536, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31918621

RESUMO

Brain-computer interfaces (BCI) decode user's intentions to control external devices. However, performance variations across individuals have limited their use to laboratory environments. Handedness could contribute to these variations, especially when motor imagery (MI) tasks are used for BCI control. To further understand how handedness affects BCI control, performance differences between two monozygotic twins were analysed during offline movement and MI tasks, and while twins controlled a BCI using right-hand MI. Quantitative electroencephalography (qEEG), brain structures' volumes, and neuropsychological tests were assessed to evaluate physiological, anatomical and psychological relationships with BCI performance. Results showed that both twins had good motor imagery and attention abilities, similar volumes on most subcortical brain structures, more pronounced event-related desynchronization elicited by the twin performing non-dominant MI, and that this twin also obtained significant higher performances with the BCI. Linear regression analysis implied a strong association between twins' BCI performance, and more pronounced cortical activations in the contralateral hemisphere relative to hand MI. Therefore, it is possible that BCI performance was related with the ability of each twin to elicit cortical activations during hand MI, and less associated with subcortical brain structures' volumes and neuropsychological tests.


Assuntos
Interfaces Cérebro-Computador , Eletroencefalografia/métodos , Lateralidade Funcional , Humanos , Imaginação , Desempenho Psicomotor/fisiologia , Gêmeos Monozigóticos
2.
J Cardiovasc Magn Reson ; 14: 23, 2012 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-22480269

RESUMO

BACKGROUND: Transthoracic echocardiography (TTE) is the standard method for the evaluation of the severity of aortic stenosis (AS). Valve effective orifice area (EOA) measured by the continuity equation is one of the most frequently used stenotic indices. However, TTE measurement of aortic valve EOA is not feasible or not reliable in a significant proportion of patients. Cardiovascular magnetic resonance (CMR) has emerged as a non-invasive alternative to evaluate EOA using velocity measurements. The objectives of this study were: 1) to validate a new CMR method using jet shear layer detection (JSLD) based on acoustical source term (AST) concept to estimate the valve EOA; 2) to introduce a simplified JSLD method not requiring vorticity field derivation. METHODS AND RESULTS: We performed an in vitro study where EOA was measured by CMR in 4 fixed stenoses (EOA = 0.48, 1.00, 1.38 and 2.11 cm²) under the same steady flow conditions (4-20 L/min). The in vivo study included eight (8) healthy subjects and 37 patients with mild to severe AS (0.72 cm² ≤ EOA ≤ 1.71 cm²). All subjects underwent TTE and CMR examinations. EOA was determinated by TTE with the use of continuity equation method (TTE(CONT)). For CMR estimation of EOA, we used 3 methods: 1) Continuity equation (CMR(CONT)); 2) Shear layer detection (CMR(JSLD)), which was computed from the velocity field of a single CMR velocity profile at the peak systolic phase; 3) Single plane velocity truncation (CMR(SPVT)), which is a simplified version of CMR(JSLD) method. There was a good agreement between the EOAs obtained in vitro by the different CMR methods and the EOA predicted from the potential flow theory. In the in vivo study, there was good correlation and concordance between the EOA measured by the TTE(CONT) method versus those measured by each of the CMR methods: CMR(CONT) (r = 0.88), CMR(JSLD) (r = 0.93) and CMR(SPVT) (r = 0.93). The intra- and inter- observer variability of EOA measurements was 5 ± 5% and 9 ± 5% for TTE(CONT), 2 ± 1% and 7 ± 5% for CMR(CONT), 7 ± 5% and 8 ± 7% for CMR(JSLD), 1 ± 2% and 3 ± 2% for CMR(SPVT). When repeating image acquisition, reproducibility of measurements was 10 ± 8% and 12 ± 5% for TTE(CONT), 9 ± 9% and 8 ± 8% for CMR(CONT), 6 ± 5% and 7 ± 4% for CMR(JSLD) and 3 ± 2% and 2 ± 2% for CMR(SPVT). CONCLUSION: There was an excellent agreement between the EOA estimated by the CMR(JSLD) or CMR(SPVT) methods and: 1) the theoretical EOA in vitro, and 2) the TTE(CONT) EOA in vivo. The CMR(SPVT) method was superior to the TTE and other CMR methods in terms of measurement variability. The novel CMR-based methods proposed in this study may be helpful to corroborate stenosis severity in patients for whom Doppler-echocardiography exam is inconclusive.


Assuntos
Estenose da Valva Aórtica/diagnóstico , Valva Aórtica/patologia , Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética/métodos , Adulto , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...