Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Dement Geriatr Cogn Disord ; 42(1-2): 7-16, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27459101

RESUMO

BACKGROUND: Several studies have stated that frailty is associated with cognitive impairment. Based on various studies, cognition impairment has been considered as a component of frailty. Other authors have shown that physical frailty is associated with low cognitive performance. Dual task gait tests are used as a strong predictor of falls in either dementia or frailty. Consequently, it is important to investigate dual task walking tests in elderly populations including control robust oldest old, frail oldest old with mild cognitive impairment (MCI) and frail oldest old without MCI. METHODS: Dual task walking tests were carried out to examine the association between frailty and cognitive impairment in a population with advanced age. Forty-one elderly men and women participated in this study. The subjects from control, frail with MCI and frail without MCI groups, completed the 5-meter walk test at their own gait velocity. Arithmetic and verbal dual task walking performance was also assessed. Kinematic data were acquired from a unique tri-axial inertial sensor. RESULTS: The spatiotemporal and frequency parameters related to gait disorders did not show any significant differences between frail with and without MCI groups. CONCLUSIONS: The evaluation of these parameters extracted from the acceleration signals led us to conclude that these results expand the knowledge regarding the common conditions in frailty and MCI and may highlight the idea that the impairment in walking performance does not depend of frailty and cognitive status.


Assuntos
Disfunção Cognitiva , Transtornos Neurológicos da Marcha , Marcha , Acidentes por Quedas , Idoso , Idoso de 80 Anos ou mais , Disfunção Cognitiva/diagnóstico , Disfunção Cognitiva/fisiopatologia , Feminino , Idoso Fragilizado/psicologia , Transtornos Neurológicos da Marcha/diagnóstico , Transtornos Neurológicos da Marcha/psicologia , Humanos , Masculino , Estatística como Assunto , Análise e Desempenho de Tarefas , Teste de Caminhada/métodos , Caminhada
2.
J Am Med Dir Assoc ; 17(2): 162-7, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26577625

RESUMO

BACKGROUND: Frailty has become the center of attention of basic, clinical, and demographic research because of its incidence level and the gravity of adverse outcomes with age. Moreover, with advanced age, motor variability increases, particularly in gait. Muscle quality and muscle power seem to be closely associated with performance on functional tests in frail populations. Insight into the relationships among muscle power, muscle quality, and functional capacity could improve the quality of life in this population. In this study, the relationship between the quality of the muscle mass and muscle strength with gait performance in a frail population was examined. METHODS: Twenty-two institutionalized frail elderly individuals (93.1 ± 3.6) participated in this study. Muscle quality was measured by segmenting areas of high- and low-density fibers as observed in computed tomography images. The assessed functional outcomes were leg strength and power, velocity of gait, and kinematic gait parameters obtained from a tri-axial inertial sensor. FINDINGS: Our results showed that a greater number of high-density fibers, specifically those of the quadriceps femoris muscle, were associated with better gait performance in terms of step time variability, regularity, and symmetry. Additionally, gait variability was associated with muscle power. In contrast, no significant relationship was observed between gait velocity and either muscle quality or muscle power. INTERPRETATION: Gait pattern disorders could be explained by a deterioration of the lower limb muscles. It is known that an impaired gait is an important predictor of falls in older populations; thus, the loss of muscle quality and power could underlie the impairments in motor control and balance that lead to falls and adverse outcomes.


Assuntos
Idoso Fragilizado , Marcha/fisiologia , Força Muscular/fisiologia , Idoso de 80 Anos ou mais , Feminino , Instituição de Longa Permanência para Idosos , Humanos , Masculino , Músculo Esquelético/diagnóstico por imagem , Tomografia Computadorizada por Raios X
3.
Age (Dordr) ; 37(6): 124, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26667940

RESUMO

The objective of this study was to investigate dual-task costs in several elderly populations, including robust oldest old, frail oldest old with MCI, frail oldest old without MCI, and frail elderly with dementia. Sixty-four elderly men and women categorized into frail without MCI (age 93.4 ± 3.2 years, n = 20), frail with MCI (age 92.4 ± 4.2 years, n = 13), robust (age 88.2 ± 4.1 years, n = 10), and patients with dementia (age 88.1 ± 5.1 years, n = 21). Five-meter gait ability and timed-up-and-go (TUG) tests with single and dual-task performance were assessed in the groups. Dual-task cost in both 5-m habitual gait velocity test and TUG test was calculated by the time differences between single and dual-task performance. The robust group exhibited better 5-m gait and TUG test performances in the single and dual-task conditions compared with the other three groups (P < 0.001), and the frail and frail + MCI groups exhibited better performances than the dementia group (P < 0.001). No significant differences were observed between the frail and frail + MCI groups. However, all groups exhibited lower gait velocities in the verbal and arithmetic task conditions, but the dual-task cost of the groups were similar. Robust individuals exhibited superior single and dual-task walking performances than the other three groups, and the frail and frail + MCI individuals exhibited performances that were superior to those of the patients with dementia. However, the dual-task costs, i.e., the changes in gait performance when elderly participants switch from a single to a dual task, were similar among all four of the investigated groups. Therefore, these results demonstrated that the magnitude of the impairment in gait pattern is independent of frailty and cognitive impairment status.


Assuntos
Disfunção Cognitiva/fisiopatologia , Idoso Fragilizado , Transtornos Neurológicos da Marcha/fisiopatologia , Institucionalização , Análise e Desempenho de Tarefas , Idoso de 80 Anos ou mais , Feminino , Avaliação Geriátrica , Humanos , Masculino , Testes Neuropsicológicos
4.
J Neuroeng Rehabil ; 12: 48, 2015 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-26003560

RESUMO

BACKGROUND: Physical frailty has become the center of attention of basic, clinical and demographic research due to its incidence level and gravity of adverse outcomes with age. Frailty syndrome is estimated to affect 20 % of the population older than 75 years. Thus, one of the greatest current challenges in this field is to identify parameters that can discriminate between vulnerable and robust subjects. Gait analysis has been widely used to predict frailty. The aim of the present study was to investigate whether a collection of parameters extracted from the trunk acceleration signals could provide additional accurate information about frailty syndrome. METHODS: A total of 718 subjects from an elderly population (319 males, 399 females; age: 75.4 ± 6.1 years, mass: 71.8 ± 12.4 kg, height: 158 ± 6 cm) volunteered to participate in this study. The subjects completed a 3-m walk test at their own gait velocity. Kinematic data were acquired from a tri-axial inertial orientation tracker. FINDINGS: The spatio-temporal and frequency parameters measured in this study with an inertial sensor are related to gait disorders and showed significant differences among groups (frail, pre-frail and robust). A selection of those parameters improves frailty classification obtained to gait velocity, compared to classification model based on gait velocity solely. INTERPRETATION: Gait parameters simultaneously used with gait velocity are able to provide useful information for a more accurate frailty classification. Moreover, this technique could improve the early detection of pre-frail status, allowing clinicians to perform measurements outside of a laboratory environment with the potential to prescribe a treatment for reversing their physical decline.


Assuntos
Acelerometria/métodos , Fenômenos Biomecânicos , Idoso Fragilizado , Caminhada/fisiologia , Idoso , Feminino , Marcha/fisiologia , Humanos , Masculino , Tronco
5.
IEEE J Biomed Health Inform ; 18(4): 1131-7, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25014928

RESUMO

Latest advances in microelectromechanical systems have made inertial units (IUs) a powerful tool for human motion analysis. However, difficulties in handling their output signals must be overcome. The purpose of this study was to develop the novel "PB-algorithm" based on polynomial data fitting, splines interpolation, and the wavelet transform, one after the other, to cancel drift disturbances in position estimation for periodic movements. High-accuracy position measurements from an optical system (Vicon Nexus 1.0) were used to validate the proposed method and comparison with another drift-correction algorithm was provided. Results indicate the accuracy with respect to the Vicon's reference signal (euclidean error lower than 54.62 × 10(-3) m and correlation coefficient higher than 0.968). A reduction of the root-mean-square error of 68.74% was obtained when the proposed two-step method was compared with a modified-band limited Fourier linear combiner. All methods were applied to data from the 30-s chair stand test, which is one of the most used clinical tests dealing with lower body strength assessment, falls prediction, and gait disorders in older adults. The relevance of this study is that after cancelling drift disturbances, and obtaining an accurate Z-position estimation, it is possible to evaluate the sit-to-stand and stand-to-sit transitions from the whole test.


Assuntos
Acelerometria/métodos , Fenômenos Biomecânicos/fisiologia , Movimento/fisiologia , Processamento de Sinais Assistido por Computador , Adolescente , Adulto , Algoritmos , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Adulto Jovem
6.
IEEE Trans Neural Syst Rehabil Eng ; 22(5): 926-36, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25014957

RESUMO

Clinicians commonly use questionnaires and tests based on daily life activities to evaluate physical function. However, the outcomes are usually more qualitative than quantitative and subtle differences are not detectable. In this review, we aim to assess the role of body motion sensors in physical performance evaluation, especially for the sit-to-stand and stand-to-sit transitions. In total, 53 full papers and conference abstracts on related topics were included and 16 different parameters related to transition performance were identified as potentially meaningful to explain certain disabilities and impairments. Transition duration is the most used to evaluate chair-related tests in real clinical settings. High-fall-risk fallers and frail subjects presented longer and more variable transition duration. Other kinematic parameters have also been highlighted in the literature as potential means to detect age-related impairments. In particular, vertical linear velocity and trunk tilt range were able to differentiate between different frailty levels. Frequency domain measures such as spectral edge frequency were also higher for elderly fallers. Lastly, approximate entropy values were larger for subjects with Parkinson's disease and were significantly reduced after treatment. This information could help clinicians in their evaluations as well as in prescribing a physical fitness program to correct a specific deficit.


Assuntos
Fenômenos Biomecânicos/fisiologia , Eletromiografia/instrumentação , Movimento (Física) , Movimento/fisiologia , Algoritmos , Interpretação Estatística de Dados , Humanos
7.
J Neuroeng Rehabil ; 11: 20, 2014 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-24581227

RESUMO

BACKGROUND: Total hip arthroplasty is a successful surgical treatment in patients with osteoarthritis of the hip. Different questionnaires are used by the clinicians to assess functional capacity and the patient's pain, despite these questionnaires are known to be subjective. Furthermore, many studies agree that kinematic and kinetic parameters are crucial to evaluate and to provide useful information about the patient's evolution for clinicians and rehabilitation specialists. However, these quantities can currently only be obtained in a fully equipped gait laboratory. Instrumented shoes can quantify gait velocity, kinetic, kinematic and symmetry parameters. The aim of this study was to investigate whether the instrumented shoes is a sufficiently sensitive instrument to show differences in mobility performance before and after total hip arthroplasty. METHODS: In this study, patients undergoing total hip arthroplasty were measured before and 6-8 months after total hip arthroplasty. Both measurement sessions include 2 functional mobility tasks while the subject was wearing instrumented shoes. Before each measurement the Harris Hip Score and the Traditional Western Ontario and McMaster Universities osteoarthritis index were administered as well. RESULTS: The stance time and the average vertical ground reaction force measured with the instrumented shoes during walking, and their symmetry index, showed significant differences before and after total hip arthroplasty. However, the data obtained with the sit to stand test did not reveal this improvement after surgery. CONCLUSIONS: Our results show that inter-limb asymmetry during a walking activity can be evaluated with the instrumented shoes before and after total hip arthroplasty in an outpatient clinical setting.


Assuntos
Artroplastia de Quadril , Limitação da Mobilidade , Especialidade de Fisioterapia/instrumentação , Recuperação de Função Fisiológica , Sapatos , Feminino , Humanos , Perna (Membro) , Masculino , Pessoa de Meia-Idade , Osteoartrite/cirurgia , Caminhada
8.
IEEE Trans Neural Syst Rehabil Eng ; 22(3): 585-92, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-23739796

RESUMO

Total hip arthroplasty (TGA) is a successful surgical procedure to treat patients with hip osteoarthritis. Clinicians use different questionnaires to evaluate these patients. Gait velocity and these questionnaires; usually show significant improvement after TGA . This clinical evaluation does, however, not provide objective, quantifiable information about the movement patterns underlying the functional capacity, which is clinically important and can currently only be obtained in a gait laboratory. There is a need to improve patient instructions and to quantify the rehabilitation process. The sit-to-stand (STS) movement is an objective performance-based task, whose assessment is related with the evaluation of functional recovery. Twenty two patients with hip osteoarthritis participated in this study. For each patient, validated questionnaires were administered and gait velocity was measured. Time, ground reaction forces, and lower limb asymmetry parameters were calculated using the instrumented force shoes (IFS) during STS movement with and without armrest. Significant inter-limb asymmetry was observed. No correlation was found between any parameter and gait velocity and questionnaires outcomes. Significant differences in time and force parameters between with/without armrest were found. Concluding, inter-limb asymmetry can be evaluated with the IFS supplying important additional information not represented by gait velocity and questionnaires usually used.


Assuntos
Artroplastia de Quadril , Fenômenos Biomecânicos/fisiologia , Perna (Membro)/fisiopatologia , Osteoartrite do Quadril/fisiopatologia , Cuidados Pré-Operatórios , Algoritmos , Feminino , Marcha , Humanos , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários , Resultado do Tratamento
9.
J Neuroeng Rehabil ; 10: 86, 2013 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-24059755

RESUMO

BACKGROUND: A growing interest in frailty syndrome exists because it is regarded as a major predictor of co-morbidities and mortality in older populations. Nevertheless, frailty assessment has been controversial, particularly when identifying this syndrome in a community setting. Performance tests such as the 30-second chair stand test (30-s CST) are a cornerstone for detecting early declines in functional independence. Additionally, recent advances in body-fixed sensors have enhanced the sensors' ability to automatically and accurately evaluate kinematic parameters related to a specific movement performance. The purpose of this study is to use this new technology to obtain kinematic parameters that can identify frailty in an aged population through the performance the 30-s CST. METHODS: Eighteen adults with a mean age of 54 years, as well as sixteen pre-frail and thirteen frail patients with mean ages of 78 and 85 years, respectively, performed the 30-s CST while their trunk movements were measured by a sensor-unit at vertebra L3. Sit-stand-sit cycles were determined using both acceleration and orientation information to detect failed attempts. Movement-related phases (i.e. impulse, stand-up, and sit-down) were differentiated based on seat off and seat on events. Finally, the kinematic parameters of the impulse, stand-up and sit-down phases were obtained to identify potential differences across the three frailty groups. RESULTS: For the stand-up and sit-down phases, velocity peaks and "modified impulse" parameters clearly differentiated subjects with different frailty levels (p < 0.001). The trunk orientation range during the impulse phase was also able to classify a subject according to his frail syndrome (p < 0.001). Furthermore, these parameters derived from the inertial units (IUs) are sensitive enough to detect frailty differences not registered by the number of completed cycles which is the standard test outcome. CONCLUSIONS: This study shows that IUs can enhance the information gained from tests currently used in clinical practice, such as the 30-s CST. Parameters such as velocity peaks, impulse, and orientation range are able to differentiate between adults and older populations with different frailty levels. This study indicates that early frailty detection could be possible in clinical environments, and the subsequent interventions to correct these disabilities could be prescribed before further degradation occurs.


Assuntos
Teste de Esforço/métodos , Idoso Fragilizado , Monitorização Fisiológica/métodos , Movimento/fisiologia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tronco
10.
Rejuvenation Res ; 16(5): 396-403, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23822577

RESUMO

This study examined the neuromuscular and functional performance differences between frail oldest old with and without mild cognitive impairment (MCI). In addition, the associations between functional capacities, muscle mass, strength, and power output of the leg muscles were also examined. Forty-three elderly men and women (91.9±4.1 years) were classified into three groups--the frail group, the frail with MCI group (frail+MCI), and the non-frail group. Strength tests were performed for upper and lower limbs. Functional tests included 5-meter habitual gait, timed up-and-go (TUG), dual task performance, balance, and rise from a chair ability. Incidence of falls was assessed using questionnaires. The thigh muscle mass and attenuation were assessed using computed tomography. There were no differences between the frail and frail+MCI groups for all the functional variables analyzed, except in the cognitive score of the TUG with verbal task, which frail showed greater performance than the frail+MCI group. Significant associations were observed between the functional performance, incidence of falls, muscle mass, strength, and power in the frail and frail+MCI groups (r=-0.73 to r=0.83, p<0.01 to p<0.05). These results suggest that the frail oldest old with and without MCI have similar functional and neuromuscular outcomes. Furthermore, the functional outcomes and incidences of falls are associated with muscle mass, strength, and power in the frail elderly population.


Assuntos
Adiposidade/fisiologia , Transtornos Cognitivos/fisiopatologia , Idoso Fragilizado , Institucionalização , Músculo Esquelético/fisiopatologia , Acidentes por Quedas , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Feminino , Marcha/fisiologia , Humanos , Contração Isométrica , Masculino , Força Muscular/fisiologia , Análise e Desempenho de Tarefas
11.
J Neuroeng Rehabil ; 10: 41, 2013 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-23602092

RESUMO

BACKGROUND: Total hip arthroplasty is a successful surgical procedure to treat hip osteoarthritis. Clinicians use different questionnaires to assess the patient's pain and functional capacity. Furthermore, they assess the quality of gait in a very global way. This clinical evaluation usually shows significant improvement after total hip arthroplasty, however, does not provide objective, quantifiable information about the movement patterns underlying the functional capacity, which can currently only be obtained in a gait laboratory. Instrumented force shoes can quantify gait velocity, ground reaction forces and the gait pattern easily in an outpatient setting. The main goal of this study was to investigate how mobility characteristics during walking, relate to gait velocity and questionnaire outcomes of patients with hip osteoarthritis in an outpatient setting. METHODS: 22 patients with primary osteoarthritis of the hip selected for a total hip arthroplasty participated in this study. For each patient the Harris Hip Score, the Traditional Western Ontario and the McMaster Universities osteoarthritis index were administered. Subsequently, the patients were instructed to walk through the corridor while wearing instrumented shoes. The gait velocity estimated with the instrumented force shoes was validated measuring the time required to walk a distance of 10 m using a stopwatch and a measuring tape as a reference system. A regression analysis between spatial, temporal, ground reaction force parameters, including asymmetry, and the gait velocity and the questionnaires outcomes was performed. RESULTS: The velocity estimated with the instrumented shoes did not differ significantly from the velocity measured independently. Although gait parameters correlated significantly with velocity, symmetry index parameters were not correlated with velocity. These symmetry index parameters show significant inter-limb asymmetry during walking. No correlation was found between any of the variables studied and questionnaires outcomes. CONCLUSION: Inter-limb asymmetry can be evaluated with the instrumented shoes supplying important additional information about the individual gait pattern, which is not represented by gait velocity and questionnaires usually used. Therefore, this new ambulatory measurement system is able to provide complementary information to gait velocity and questionnaires outcomes to assess the functional capacity of patients with hip osteoarthritis.


Assuntos
Artroplastia de Quadril , Extremidade Inferior/fisiologia , Caminhada/fisiologia , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Fenômenos Biomecânicos , Interpretação Estatística de Dados , Feminino , Marcha/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/reabilitação , Osteoartrite do Quadril/cirurgia , Período Pré-Operatório , Análise de Regressão , Reprodutibilidade dos Testes , Inquéritos e Questionários , Resultado do Tratamento
12.
IEEE J Biomed Health Inform ; 17(4): 820-7, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25055310

RESUMO

The aim of this study was to evaluate the inertial measures of the 30-s chair stand test using modern body-fixed motion sensors. Polynomial data fitting was used to correct the drift effect in the position estimation. Thereafter, the three most important test cycles phases ("impulse," "stand up," and "sit down") were characterized and automatically analyzed. Automated test control is provided, making it possible for researchers without engineering knowledge to run the test. A collection of meaningful data based on kinematic variables is selected for further research. The proposed methodology for data analysis is a feasible tool for use in clinical settings. This method may not only improve rehabilitation therapies but also identify people at risk for falls more accurately than simply evaluating the number of cycles.


Assuntos
Acelerometria/métodos , Monitorização Fisiológica/métodos , Postura/fisiologia , Processamento de Sinais Assistido por Computador , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos/fisiologia , Feminino , Marcadores Fiduciais , Humanos , Imãs , Masculino , Movimento/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...