Opt Express ; 25(6): 6349-6364, 2017 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-28380987

RESUMO

An X-ray grating interferometer (GI) suitable for clinical mammography must comply with quite strict dose, scanning time and geometry limitations, while being able to detect tumors, microcalcifications and other abnormalities. Such a design task is not straightforward, since obtaining optimal phase-contrast and dark-field signals with clinically compatible doses and geometrical constraints is remarkably challenging. In this work, we present a wave propagation based optimization that uses the phase and dark-field sensitivities as figures of merit. This method was used to calculate the optimal interferometer designs for a commercial mammography setup. Its accuracy was validated by measuring the visibility of polycarbonate samples of different thicknesses on a Talbot-Lau interferometer installed on this device and considering some of the most common grating imperfections to be able to reproduce the experimental values. The optimization method outcomes indicate that small grating pitches are required to boost sensitivity in such a constrained setup and that there is a different optimal scenario for each signal type.

2.
Med Phys ; 42(4): 1959-65, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25832086

RESUMO

PURPOSE: The purpose of this work is to investigate the feasibility of grating-based, differential phase-contrast, full-field digital mammography (FFDM) in terms of the requirements for field-of-view (FOV), mechanical stability, and scan time. METHODS: A rigid, actuator-free Talbot interferometric unit was designed and integrated into a state-of-the-art x-ray slit-scanning mammography system, namely, the Philips MicroDose L30 FFDM system. A dedicated phase-acquisition and phase retrieval method was developed and implemented that exploits the redundancy of the data acquisition inherent to the slit-scanning approach to image generation of the system. No modifications to the scan arm motion control were implemented. RESULTS: The authors achieve a FOV of 160 × 196 mm consisting of two disjoint areas measuring 77 × 196 mm with a gap of 6 mm between them. Typical scanning times vary between 10 and 15 s and dose levels are lower than typical FFDM doses for conventional scans with identical acquisition parameters due to the presence of the source-grating G0. Only minor to moderate artifacts are observed in the three reconstructed images, indicating that mechanical vibrations induced by other system components do not prevent the use of the platform for phase contrast imaging. CONCLUSIONS: To the best of our knowledge, this is the first attempt to integrate x-ray gratings hardware into a clinical mammography unit. The results demonstrate that a scanning differential phase contrast FFDM system that meets the requirements of FOV, stability, scan time, and dose can be build.


Assuntos
Mamografia/instrumentação , Mamografia/métodos , Animais , Artefatos , Desenho de Equipamento , Estudos de Viabilidade , Processamento de Imagem Assistida por Computador/instrumentação , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Doses de Radiação , Dourada , Fatores de Tempo
3.
Invest Radiol ; 50(4): 297-304, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25551821

RESUMO

OBJECTIVES: The objective of this study was to investigate the feasibility and the accuracy of spectral computed tomography (spectral CT) to determine the tissue concentrations and localization of high-attenuation, iodine-based contrast agents in mice. Iodine tissue concentrations determined with spectral CT are compared with concentrations measured with single-photon emission computed tomography (SPECT) and inductively coupled plasma mass spectrometry (ICP-MS). MATERIALS AND METHODS: All animal procedures were performed according to the US National Institutes of Health principles of laboratory animal care and were approved by the ethical review committee of Maastricht, The Netherlands. Healthy Swiss mice (n = 4) were injected with an iodinated emulsion radiolabeled with indium as multimodal contrast agent for CT and SPECT. The CT and SPECT scans were acquired using a dedicated small-animal SPECT/CT system. Subsequently, scans were performed with a preclinical spectral CT scanner equipped with a photon-counting detector and 6 energy threshold levels. Quantitative data analysis of SPECT and spectral CT scans were obtained using 3-dimensional volumes-of-interest drawing methods. The ICP-MS on dissected organs was performed to determine iodine uptake per organ and was compared with the amounts determined from spectral CT and SPECT. RESULTS: Iodine concentrations obtained with image-processed spectral CT data correlated well with data obtained either with noninvasive SPECT imaging (slope = 0.96, r = 0.75) or with ICP-MS (slope = 0.99, r = 0.89) in tissue samples. CONCLUSIONS: This preclinical proof-of-concept study shows the in vivo quantification of iodine concentrations in tissues using spectral CT. Our multimodal imaging approach with spectral CT and SPECT using radiolabeled iodinated emulsions together with ICP-based quantification allows a direct comparison of all methods. Benchmarked against ICP-MS data, spectral CT in the present implementation shows a slight underestimation of organ iodine concentrations compared with SPECT but with a more narrow distribution. This slight deviation is most likely caused by experimental rather than technical issues.


Assuntos
Meios de Contraste/farmacocinética , Radioisótopos de Índio/farmacocinética , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Animais , Estudos de Viabilidade , Imageamento Tridimensional , Iodo , Camundongos , Reprodutibilidade dos Testes , Espectrofotometria Atômica , Tomografia Computadorizada de Emissão de Fóton Único
4.
Philos Trans A Math Phys Eng Sci ; 372(2010): 20130033, 2014 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-24470415

RESUMO

Research in grating-based differential phase-contrast imaging (DPCI) has gained increasing momentum in the past couple of years. The first results on the potential clinical benefits of the technique for X-ray mammography are becoming available and indicate improvements in terms of general image quality, the delineation of lesions versus the background tissue and the visibility of microcalcifications. In this paper, we investigate some aspects related to the technical feasibility of DPCI for human X-ray mammography. After a short introduction to state-of-the-art full-field digital mammography in terms of technical aspects as well as clinical aspects, we put together boundary conditions for DPCI. We then discuss the implications for system design in a comparative manner for systems with two-dimensional detectors versus slit-scanning systems, stating advantages and disadvantages of the two designs. Finally, focusing on a slit-scanning system, we outline a possible concept for phase acquisition.


Assuntos
Mamografia/métodos , Temperatura Alta , Humanos , Processamento de Imagem Assistida por Computador , Interferometria , Mamografia/instrumentação , Mastectomia , Movimento , Doses de Radiação , Intensificação de Imagem Radiográfica , Fatores de Tempo
5.
Radiology ; 254(1): 270-6, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20032158

RESUMO

PURPOSE: To evaluate the capability of spectral computed tomography (CT) to improve the characterization of cystic high-attenuation lesions in a renal phantom and to test the hypothesis that spectral CT will improve the differentiation of cystic renal lesions with high protein content and those that have undergone hemorrhage or malignant contrast-enhancing transformation. MATERIALS AND METHODS: A renal phantom that contained cystic lesions grouped in nonenhancing cyst and hemorrhage series and an iodine-enhancing series was developed. Spectral CT is based on new detector designs that may possess energy-sensitive photon-counting abilities, thereby facilitating the assessment of quantitative information about the elemental and molecular composition of tissue or contrast materials. Imaging of the renal phantom was performed with a prototype scanner at 20 mAs and 70 keV, allowing characterization of x-ray photons at 25-34, 34-39, 39-44, 44-49, 49-55, and more than 55 keV. Region of interest analysis was used to determine lesion attenuation values at various x-ray energies. Statistical analysis was performed to assess attenuation patterns and identify distinct levels of attenuation on the basis of curve regression analysis with analysis of variance tables. RESULTS: Spectral CT depicted linear clusters for the cyst (P < .001, R(2) > 0.940) and hemorrhage (P < .001, R(2) > 0.962) series without spectral overlap. A distinct linear attenuation profile without spectral overlap was also detected for the iodine-enhancing series (P < .001, R(2) > 0.964), with attenuation values attained in the 34-39-keV energy bin statistically identified as outliers (mean slope variation, >37%), corresponding with iodine k-edge effects at 33.2 keV. CONCLUSION: Spectral CT has the potential to enable distinct characterization of hyperattenuating fluids in a renal phantom by helping identify proteinaceous and hemorrhagic lesions through assessment of their distinct levels of attenuation as well as by revealing iodine-containing lesions through analysis of their specific k-edge discontinuities.


Assuntos
Doenças Renais Císticas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Humanos , Doenças Renais Císticas/patologia , Imagens de Fantasmas , Fótons , Interpretação de Imagem Radiográfica Assistida por Computador , Análise de Regressão , Tomografia Computadorizada por Raios X/instrumentação
6.
Radiology ; 249(3): 1010-6, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18849505

RESUMO

The purpose of this study was to investigate whether spectral computed tomography (CT) has the potential to improve luminal depiction by differentiating among intravascular gadolinium-based contrast agent, calcified plaque, and stent material by using the characteristic k edge of gadolinium. A preclinical spectral CT scanner with a photon-counting detector and six energy threshold levels was used to scan a phantom vessel. A partially occluded stent was simulated by using a calcified plaque isoattenuated to a surrounding gadolinium chelate solution. The reconstructed images showed an effective isolation of the gadolinium with subsequent clear depiction of the perfused vessel lumen. The calcified plaque and the stent material are suppressed.


Assuntos
Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X/métodos , Gadolínio , Imagens de Fantasmas , Fótons , Stents , Tomografia Computadorizada por Raios X/instrumentação