Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 109
Filtrar
1.
J Arrhythm ; 40(2): 247-255, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38586837

RESUMO

Background: Lesion size is reported to become larger as contact force (CF) increases. However, this has not been systematically evaluated in temperature-guided very high-power short-duration (vHPSD) ablation, which was therefore the purpose of this study. Methods: Radiofrequency applications (90 W/4 s, temperature-control mode) were performed in excised porcine myocardium with four different CFs of 5, 15, 25, and 35 g using QDOT-MICRO™ catheter. Ten lesions for each combination of settings were created, and lesion metrics and steam-pops were compared. Results: A total of 320 lesions were analyzed. Lesion depth, surface area, and volume were smallest for CF of 5 g than for 15, 25, and 35 g (depth: 2.7 mm vs. 2.9 mm, 3.0 mm, 3.15 mm, p < .01; surface area: 38.4 mm2 vs. 41.8 mm2, 43.3 mm2, 41.5 mm2, p < .05; volume: 98.2 mm3 vs. 133.3 mm3, 129.4 mm3, 126.8 mm3, p < .01 for all pairs of groups compared to CF = 5 g). However, no significant differences were observed between CFs of 15-35 g. Average power was highest for CF of 5 g, followed by 15, 25, and 35 g (83.2 W vs. 82.1 W vs. 77.1 W vs. 66.1 W, p < .01 for all pairs), reflecting the higher incidence of temperature-guided power titration with greater CFs (5 g:8.8% vs. 15 g:52.5% vs. 25 g:77.5% vs. 35 g:91.2%, p < .01 for all pairs except for 25 g vs. 35 g). The incidence of steam-pops did not significantly differ between four groups (5 g:3.8% vs. 15 g:10% vs. 25 g:6.2% vs. 35 g:2.5%, not significant for all pairs). Conclusions: For vHPSD ablation, lesion size does not become large once the CF reaches 15 g, and the risk of steam-pops may be mitigated through power titration even in high CFs.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38478165

RESUMO

BACKGROUND: CRAFT was an international, multicentre, randomised controlled trial across 11 sites in the United UK and Switzerland. Given the evidence that pulmonary vein triggers may be responsible for atrial flutter (AFL) as well as atrial fibrillation (AF), we hypothesised that cryoballoon pulmonary vein isolation (PVI) would provide greater symptomatic arrhythmia reduction than cavotricuspid isthmus (CTI) ablation, whilst also reducing the subsequent burden of AF. Twelve-month outcomes were previously reported. In this study, we report the extended outcomes of the CRAFT study to 36 months. METHODS: Patients with typical AFL and no evidence of AF were randomised 1:1 to cryoballoon PVI or radiofrequency CTI. All patients received an implantable loop recorder (ILR) for continuous cardiac rhythm monitoring. The primary outcome was time-to-symptomatic arrhythmia recurrence > 30 s. Secondary outcomes included time-to-first-AF episode ≥ 2 min. The composite safety outcome included death, stroke and procedural complications. RESULTS: A total of 113 patients were randomised to cryoballoon PVI (n = 54) or radiofrequency CTI ablation (n = 59). Ninety-one patients reconsented for extended follow-up beyond 12 months. There was no difference in the primary outcome between arms, with the primary outcome occurring in 12 PVI vs 11 CTI patients (HR 0.97; 95% CI 0.43-2.20; p = 0.994). AF ≥ 2 min was significantly less frequent in the PVI arm, affecting 26 PVI vs 36 CTI patients (HR 0.48; 95% CI 0.29-0.79; p = 0.004). The composite safety outcome occurred in 5 PVI and 6 CTI patients (p = 0.755). CONCLUSION: Cryoballoon PVI shows similar efficacy to radiofrequency CTI ablation in reducing symptomatic arrhythmia recurrence in patients presenting with isolated typical AFL but significantly reduces the occurrence of subsequent AF.

3.
Heart Rhythm ; 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38460753

RESUMO

BACKGROUND: Unipolar electrograms (uni-EGMs) are an essential part of intracardiac mapping. Although Wilson central terminal (WCT) is conventionally used as a reference for signals, avoidance of contamination by far-field and nonphysiologic signals is challenging. OBJECTIVE: The aim of the study was to explore the impact of an intracardiac indifferent reference electrode close to the recording electrodes, in lieu of WCT, on electrograms. METHODS: Sinus node activation was mapped in patients undergoing catheter ablation by a multielectrode array with a close indifferent electrode (CIE) embedded in the distal end of the catheter shaft. An equal number of points was sequentially acquired at each site with use of CIE as a reference first and subsequently with WCT. Uni-EGMs, bipolar EGMs, and the earliest activation area (defined as the area activated in the first 10 ms of the beat) were compared between CIE- and WCT-based activation maps. RESULTS: Seventeen patients (61 ± 18 years; 76% male) were studied. Uni-EGM voltages acquired with CIE were significantly larger than (n = 11) or comparable to (n = 4) those acquired with WCT. When points from the entire cohort were analyzed altogether, unipolar voltages and their maximum negative dV/dT and bipolar voltages recorded with CIE were significantly larger than those recorded with WCT (2.36 [1.42-3.79] mV vs 1.96 [1.25-3.03] mV, P < .0001; 0.40 [0.18-0.77] mV/s vs 0.35 [0.15-0.71] mV/s, P < .0001; and 1.46 [0.66-2.81] mV vs 1.33 [0.54-2.64] mV, P < .0001, respectively). The earliest activation area was significantly smaller in CIE-based activation maps than in WCT-based ones (0.3 [0.7-1.4] cm2 vs 0.6 [1.0-1.8] cm2, P = .01). CONCLUSION: CIE-based maps were associated with an approximately 20% increase in unipolar voltage and may highlight the origin of a focal activation more clearly than WCT-based ones.

4.
Heart Rhythm ; 21(6): 836-844, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38336193

RESUMO

BACKGROUND: The PRAETORIAN score estimates the risk of failure of subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy by using generator and lead positioning on bidirectional chest radiographs. The PRospective randomized compArative trial of subcutanEous implanTable cardiOverter-defibrillatoR ImplANtation with and without DeFibrillation Testing (PRAETORIAN-DFT) investigates whether PRAETORIAN score calculation is noninferior to defibrillation testing (DFT) with regard to first shock efficacy in spontaneous events. OBJECTIVE: This prespecified subanalysis assessed the predictive value of the PRAETORIAN score for defibrillation success in induced ventricular arrhythmias. METHODS: This multicenter investigator-initiated trial randomized 965 patients between DFT and PRAETORIAN score calculation after de novo S-ICD implantation. Successful DFT was defined as conversion of induced ventricular arrhythmia in <5 seconds from shock delivery within 2 attempts. Bidirectional chest radiographs were obtained after implantation. The predictive value of the PRAETORIAN score for DFT success was calculated for patients in the DFT arm. RESULTS: In total, 482 patients were randomized to undergo DFT. Of these patients, 457 (95%) underwent DFT according to protocol, of whom 445 (97%) had successful DFT and 12 (3%) had failed DFT. A PRAETORIAN score of ≥90 had a positive predictive value of 25% for failed DFT, and a PRAETORIAN score of <90 had a negative predictive value of 99% for successful DFT. A PRAETORIAN score of ≥90 was the strongest independent predictor for failed DFT (odds ratio 33.77; confidence interval 6.13-279.95; P < .001). CONCLUSION: A PRAETORIAN score of <90 serves as a reliable indicator for DFT success in patients with S-ICD, and a PRAETORIAN score of ≥90 is a strong predictor for DFT failure.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica , Valor Preditivo dos Testes , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Cardioversão Elétrica/métodos , Estudos Prospectivos , Idoso , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Medição de Risco/métodos , Taquicardia Ventricular/terapia , Taquicardia Ventricular/fisiopatologia , Fibrilação Ventricular/terapia
5.
Artigo em Inglês | MEDLINE | ID: mdl-37946002

RESUMO

PURPOSE: Radiofrequency (RF) ablation with half-normal saline (HNS) irrigation is reported to potentially enlarge local lesion compared to normal saline (NS) in power-controlled ablation (PC-Abl). However, the effect of HNS-irrigation in temperature-flow-controlled ablation (TFC-Abl) on lesion characteristics is unknown. We compared this between TFC-Abl with QDOT-Micro™ catheter and PC-Abl with Thermocool SmartTouch SF™ catheter (STSF). METHODS: RF-application with NS (n = 480) and HNS (n = 480) irrigation were performed on swine myocardium placed in a circulating saline bath. Lesion characteristics without steam-pops under various conditions (target AI, 400/550; ablation power, 30/50 W; contact force, 10/20/30 g; catheter orientation, perpendicular/parallel) were assessed and compared between two irrigants. RESULTS: After matching, 343 lesions without steam-pops in each group were evaluated. In PC-Abl, lesion size did not differ between two groups (NS, 188 ± 97 vs. HNS, 200 ± 95 mm3, p = 0.28 in volume; 33.9 ± 7.3 vs. 34.8 ± 9.5 mm2, p = 0.34 in surface area; and 4.0 ± 1.0 vs. 4.0 ± 1.0 mm, p = 0.81 in depth), but steam-pops were more frequently observed with HNS-irrigation (23.8% vs. 37.9%, p = 0.001). Contrary, in TFC-Abl, HNS-irrigation produced significantly larger (214 ± 106 vs. 243 ± 128 mm3, p = 0.017) and deeper (4.0 ± 1.0 vs. 4.3 ± 1.1 mm, p = 0.002) lesions without increasing the risk of steam-pops (15.0% vs 15.0%, p = 0.99). Automatic temperature-guided titration was more frequently observed in HNS-irrigation (54.8% vs. 78.5%, p < 0.001). CONCLUSIONS: TFC-Abl with QDOT-Micro™ catheter utilizing HNS-irrigation might increase volume and depth of local lesion without increasing the risk of stem-pops compared to NS-irrigation. Power-controlled ablation with HNS-irrigation showed similar focal lesion with higher incidence of steam-pops (SPs) compared to normal saline (NS) irrigation. Contrary, temperature-flow-controlled ablation with HNS-irrigation provided larger and deeper lesion than NS-irrigation with similar incidence of SPs. ns, p > 0.05; *, 0.01 < p ≤ 0.05; **, 0.005 < p ≤ 0.01. HNS, half-normal saline; NS, normal saline.

6.
Circulation ; 148(22): 1814-1818, 2023 11 28.
Artigo em Inglês | MEDLINE | ID: mdl-38011246
7.
Circ J ; 87(12): 1757-1764, 2023 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-37899173

RESUMO

BACKGROUND: For lesion size prediction, each input parameter, including ablation energy (AE), and output parameter, such as impedance, is individually used. We hypothesize that using both parameters simultaneously may be more optimal.Methods and Results: Radiofrequency applications at a range of power (30-50 W), contact force (10 g and 20 g), duration (10-60 s), and catheter orientation with normal saline (NS)- or half-normal saline (HNS)-irrigation were performed in excised porcine hearts. The correlations, with lesion size of AE, absolute impedance drop (∆Imp-drop), relative impedance drop (%Imp-drop), and AE*%Imp-drop were examined. Lesion size was analyzed in 283 of 288 lesions (NS-irrigation, n=142; HNS-irrigation, n=141) without steam pops. AE*%Imp-drop consistently showed the strongest correlations with lesion maximum depth (NS-irrigation, ρ=0.91; HNS-irrigation, ρ=0.94), surface area (NS-irrigation, ρ=0.87; HNS-irrigation, ρ=0.86), and volume (NS-irrigation, ρ=0.94; HNS-irrigation, ρ=0.94) compared with the other parameters. Moreover, compared with AE alone, AE*%Imp-drop significantly improved the strength of correlation with lesion maximum depth (AE vs. AE*%Imp-drop, ρ=0.83 vs. 0.91, P<0.01), surface area (ρ=0.73 vs. 0.87, P<0.01), and volume (ρ=0.84 vs. 0.94, P<0.01) with NS-irrigation. This tendency was also observed with HNS-irrigation. Parallel catheter orientation showed a better correlation with lesion depth and volume using ∆Imp-drop, %Imp-drop, and AE*%Imp-drop than perpendicular orientation. CONCLUSIONS: The combination of input and output parameters is more optimal than each single parameter for lesion prediction.


Assuntos
Ablação por Cateter , Solução Salina , Animais , Suínos , Ventrículos do Coração/patologia , Coração , Catéteres , Ablação por Cateter/métodos , Desenho de Equipamento , Impedância Elétrica
8.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37738643

RESUMO

AIMS: Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation for atrial fibrillation (AF). There are limited data on the PolarX Cryoballoon. The study aimed to establish the safety, efficacy, and feasibility of same day discharge for Cryoballoon PVI. METHODS AND RESULTS: Multi-centre study across 12 centres. Procedural metrics, safety profile, and procedural efficacy of the PolarX Cryoballoon with the Arctic Front Advance (AFA) Cryoballoon were compared in a cohort large enough to provide definitive comparative data. A total of 1688 patients underwent PVI with cryoablation (50% PolarX and 50% AFA). Successful PVI was achieved with 1677 (99.3%) patients with 97.2% (n = 1641) performed as day case procedures with a complication rate of <1%. Safety, procedural metrics, and efficacy of the PolarX Cryoballoon were comparable with the AFA cohort. The PolarX Cryoballoon demonstrated a nadir temperature of -54.6 ± 7.6°C, temperature at 30 s of -38.6 ± 7.2°C, time to -40°C of 34.1 ± 13.7 s, and time to isolation of 49.8 ± 33.2 s. Independent predictors for achieving PVI included time to reach -40°C [odds ratio (OR) 1.34; P < 0.001] and nadir temperature (OR 1.24; P < 0.001) with an optimal cut-off of ≤34 s [area under the curve (AUC) 0.73; P < 0.001] and nadir temperature of ≤-54.0°C (AUC 0.71; P < 0.001), respectively. CONCLUSIONS: This large-scale UK multi-centre study has shown that Cryoballoon PVI is a safe, effective day case procedure. PVI using the PolarX Cryoballoon was similarly safe and effective as the AFA Cryoballoon. The cryoablation metrics achieved with the PolarX Cryoballoon were different to that reported with the AFA Cryoballoon. Modified cryoablation targets are required when utilizing the PolarX Cryoballoon.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Resultado do Tratamento , Fatores de Tempo , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Reino Unido , Recidiva
9.
J Cardiovasc Electrophysiol ; 34(8): 1772-1775, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37431271

RESUMO

INTRODUCTION: We present the first worldwide use of pulsed-field ablation (PFA) for ventricular tachycardia (VT) ablation via a retrograde approach. METHODS: The patient had previously failed conventional ablation of an intramural circuit underneath the aortic valve. The same VT circuit was inducible during the procedure. The Farawave PFA catheter and Faradrive sheath were used to deliver PFA applications. RESULTS: Post ablation mapping demonstrated scar homogenization. There was no evidence of coronary spasm during PFA applications and no other complications occurred. VT was non-inducible post ablation and the patient has remained free of arrhythmia at follow-up. CONCLUSION: PFA for VT via a retrograde approach is feasible and effective.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento
10.
J Cardiovasc Electrophysiol ; 34(8): 1671-1680, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37337433

RESUMO

INTRODUCTION: Little is known about the impact of blood-pool local impedance (LI) on lesion characteristics and the incidence of steam pops. METHODS: Radiofrequency applications at a range of powers (30, 40, and 50 W), contact forces (CF) (5, 15, and 25 g), and durations (15, 30, 45, and 120 s) using perpendicular/parallel catheter orientation were performed in 40 excised porcine preparations, using a catheter capable of monitoring LI (StablePoint©, Boston Scientific). To simulate the variability in blood-pool impedance, the saline-pool LI was modulated by calibrating saline concentrations. Lesion characteristics were compared under three values of saline-pool LI: 120, 160, and 200 Ω. RESULTS: Of 648 lesions created, steam pops occurred in 175 (27.0%). When power, CF, time, and catheter orientation were adjusted, ablation at a saline-pool impedance of 160 or 200 Ω more than doubled the risk of steam pops compared with a saline-pool impedance of 120 Ω (Odds ratio = 2.31; p = .0002). Lesions in a saline-pool impedance of 120 Ω were significantly larger in surface area (50 [38-62], 45 [34-56], and 41 [34-60] mm2 for 120, 160, and 200 Ω, p < .05), but shallower in depth (4.0 [3-5], 4.4 [3.2-5.3], and 4.5 [3.8-5.5] mmfor 120, 160, and 200 Ω, respectively, p < .05) compared with the other two settings. The correlation between the absolute LI-drop and lesion size weakened as the saline-pool LI became higher (e.g., 120 Ω group (r2 = .30, r2 = .18, and r2 = .16, respectively for 120, 160, and 200 Ω), but the usage of %LI-drop (= absolute LI-drop/initial LI) instead of absolute LI-drop may minimize this effect. CONCLUSIONS: In an experimental model, baseline saline-pool impedance significantly affects the lesion metrics and the risk of steam pops.


Assuntos
Ablação por Cateter , Vapor , Suínos , Animais , Impedância Elétrica , Benchmarking , Ablação por Cateter/efeitos adversos , Solução Salina
11.
Heart Rhythm O2 ; 4(2): 134-146, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36873315

RESUMO

In the setting of structural heart disease, ventricular tachycardia (VT) is typically associated with a re-entrant mechanism. In patients with hemodynamically tolerated VTs, activation and entrainment mapping remain the gold standard for the identification of the critical parts of the circuit. However, this is rarely accomplished, as most VTs are not hemodynamically tolerated to permit mapping during tachycardia. Other limitations include noninducibility of arrhythmia or nonsustained VT. This has led to the development of substrate mapping techniques during sinus rhythm, eliminating the need for prolonged periods of mapping during tachycardia. Recurrence rates following VT ablation are high; therefore, new mapping techniques for substrate characterization are required. Advances in catheter technology and especially multielectrode mapping of abnormal electrograms has increased the ability to identify the mechanism of scar-related VT. Several substrate-guided approaches have been developed to overcome this, including scar homogenization and late potential mapping. Dynamic substrate changes are mainly identified within regions of myocardial scar and can be identified as local abnormal ventricular activities. Furthermore, mapping strategies incorporating ventricular extrastimulation, including from different directions and coupling intervals, have been shown to increase the accuracy of substrate mapping. The implementation of extrastimulus substrate mapping and automated annotation require less extensive ablation and would make VT ablation procedures less cumbersome and accessible to more patients.

12.
J Cardiovasc Electrophysiol ; 34(4): 908-917, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36906814

RESUMO

INTRODUCTION: The QDOT-MicroTM catheter is a novel irrigated contact force (CF) sensing catheter which benefits from thermocouples for temperature monitoring, allowing temperature-flow-controlled (TFC) ablation. We compared lesion metrics at fixed ablation index (AI) value during TFC-ablation and conventional power-controlled (PC)-ablation. METHODS: A total of 480 RF-applications were performed on ex-vivo swine myocardium with predefined AI targets (400/550) or until steam-pop occurred, using the QDOT-MicroTM (TFC-ablation) and Thermocool SmartTouch SFTM (PC-ablation). RESULTS: Both TFC-ablation and PC-ablation produced similar lesions in volume (218 ± 116 vs. 212 ± 107 mm3 , p = .65); however, lesions using TFC-ablation were larger in surface area (41.3 ± 8.8 vs. 34.8 ± 8.0 mm2 , p < .001) and shallower in depth (4.0 ± 1.0 vs. 4.2 ± 1.1 mm, p = .044). Average power tended to be lower in TFC-alation (34.2 ± 8.6 vs. 36.9 ± 9.2, p = .005) compared to PC-ablation due to automatic regulation of temperature and irrigation-flow. Although steam-pops were less frequent in TFC-ablation (24% vs. 15%, p = .021), they were particularly observed in low-CF (10 g) and high-power ablation (50 W) in both PC-ablation (n = 24/240, 10.0%) and TFC-ablation (n = 23/240, 9.6%). Multivariate analysis revealed that high-power, low-CF, long application time, perpendicular catheter orientation, and PC-ablation were risk factors for steam-pops. Furthermore, activation of automatic regulation of temperature and irrigation-flow was independently associated with high-CF and long application time while ablation power had no significant relationship. CONCLUSIONS: With a fixed target AI, TFC-ablation reduced the risk of steam-pops, producing similar lesions in volume, but with different metrics in this ex-vivo study. However, lower CF and higher power in fixed-AI ablation may increase the risk of steam-pops.


Assuntos
Ablação por Cateter , Vapor , Suínos , Animais , Temperatura , Ablação por Cateter/efeitos adversos , Irrigação Terapêutica/efeitos adversos , Desenho de Equipamento
13.
J Cardiovasc Electrophysiol ; 34(4): 888-897, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36852902

RESUMO

BACKGROUND/OBJECTIVES: The QDOT-MICRO™ catheter allows very high-power and short-duration (vHPSD) ablation. This study aimed to investigate lesion characteristics using different ablation settings. METHODS: Radiofrequency applications (90 W/4 s, temperature-control mode with 55°C or 60°C target) were performed in excised porcine myocardium using three different approaches: single (SA), double nonrepetitive (DNRA), and double repetitive applications (DRA). Applications were performed with an interval of 1 min for DNRA, and without interval for DRA. RESULTS: A total of 480 lesions were analyzed. Lesion depth and volume were largest for DRA followed by DNRA and SA regardless of catheter direction (depth: 3.8 vs. 3.3 vs. 2.6 mm, p < .001 for all comparisons; volume: 176.6 vs. 145.1 vs. 97.0 mm3 , p < .001 for all comparisons). Surface area was significantly larger for DRA than for SA (45.1 vs. 38.3 mm2 , p < .001) and larger for DNRA than for SA (44.5 vs. 38.3 mm2 , p < .001), but was similar between DRA and DNRA (45.1 vs. 44.5 mm2 , p = .54). Steam-pops more frequently occurred for DRA than for SA (15.6% vs. 4.4%, p = .004) and DNRA (15.6% vs. 6.9%, p = .061), but the incidence was similar between SA and DNRA (4.4% vs. 6.9%, p = 1). Although surface area and lesion volume were larger in lesions with steam-pops than without steam-pops (46.5 vs. 38.1 mm2 , p = .018 and 128.3 vs. 96.8 mm3 , p = .068, respectively), lesions were not deeper (pop(+): 2.5 mm vs. pop(-): 2.6 mm, p = .75). CONCLUSIONS: DNRA produces larger lesions than SA without increasing the risk of steam-pops. DRA produces the largest lesions among the three groups, but with an increased risk of steam-pops. Even with steam-pops, lesions do not become deeper in vHPSD ablation.


Assuntos
Ablação por Cateter , Vapor , Suínos , Animais , Ablação por Cateter/efeitos adversos , Irrigação Terapêutica/efeitos adversos , Desenho de Equipamento , Catéteres
14.
J Cardiovasc Electrophysiol ; 34(5): 1141-1151, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36808788

RESUMO

INTRODUCTION: Preliminary data suggest that high power short duration (HPSD) ablation for pulmonary vein isolation (PVI) are safe. Limited data are available on its effectiveness. Aim was to evaluate HPSD ablation in atrial fibrillation ablation using a novel Qdot Micro catheter. METHODS AND RESULTS: Prospective multicenter study evaluating safety and efficacy of PVI with HPSD ablation. First pass isolation (FPI) and sustained PVI was assessed. If FPI was not achieved additional ablation index (AI)-guided ablation with 45 W was performed and metrics predictive of this were determined. Sixty-five patients and 260 veins were treated. Procedural and LA dwell time was 93.9 ± 30.4 and 60.5 ± 23.1 min, respectively. FPI was achieved in 47 (72.3%) patients and 231 veins (88.8%) with an ablation duration of 4.6 ± 1.0 min. Twenty-nine veins required additional AI-guided ablation to achieve initial PVI with 24 anatomical sites ablated with the right posterior carina being the most common site (37.5%). A contact force of ≥8 g (area under the curve [AUC]: 0.81; p < 0.001) and catheter position variation of ≤1.2 mm (AUC: 0.79; p < 0.001) with HPSD were strongly predictive of not requiring additional AI-guided ablation. Out of the 260 veins, only 5 (1.9%) veins showed acute reconnection. HPSD ablation was associated with shorter procedure times (93.9 vs. 159.4 min; p < 0.001), ablation times (6.1 vs. 27.7 min; p < 0.001), and lower rates of PV reconnection (9.2% vs. 30.8%; p = 0.004) compared to moderate power cohort. CONCLUSIONS: HPSD ablation is an effective ablation modality which results in effective PVI whilst maintaining a safety profile. Its superiority needs to be evaluated in randomized controlled trials.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Frequência Cardíaca , Veias Pulmonares/cirurgia , Estudos Prospectivos , Catéteres , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento , Recidiva
15.
J Cardiovasc Electrophysiol ; 34(4): 833-840, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36786515

RESUMO

INTRODUCTION: Pulmonary vein isolation (PVI) is well established as a primary treatment for atrial fibrillation (AF). The POLAR ICE study was designed to collect prospective real world data on the safety and effectiveness of the POLARxTM cryoballoon for PVI to treat paroxysmal AF. METHODS: POLAR ICE, a prospective, non-randomized, multicenter (international) registry (NCT04250714), enrolled 399 patients across 19 European centers. Procedural characteristics, such as time to isolation, cryoablations per pulmonary vein (PV), balloon nadir temperature, and occlusion grade were recorded. PVI was confirmed with entrance block testing. RESULTS: Data on 372 de novo PVI procedures (n = 2190 ablations) were collected. Complete PVI was achieved in 96.8% of PVs. Procedure and fluoroscopy times were 68.2 ± 24.6 and 15.6 ± 9.6 min, respectively. Left atrial dwell time was 46.6 ± 18.3 min. Grade 3 or 4 occlusion was achieved in 98.2% of PVs reported and 71.2% of PVs isolation required only a single cryoablation. Of 2190 cryoapplications, 83% had a duration of at least 120 s; nadir temperature of these ablations averaged -56.3 ± 6.5°C. There were 6 phrenic nerve palsy events, 2 of which resolved within 3 months of the procedure. CONCLUSION: This real-world usage data on a novel cryoballoon suggests this device is effective, safe, and relatively fast in centers with cryoballoon experience. These data are comparable to prior POLARx reports and in keeping with reported data on other cryoballoons. Future studies should examine the long-term outcomes and the relationship between biophysical parameters and outcomes for this novel cryoballoon.


Assuntos
Fibrilação Atrial , Humanos , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Átrios do Coração , Fluoroscopia
16.
Pacing Clin Electrophysiol ; 46(6): 515-518, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36690018

RESUMO

The 12-lead electrocardiogram (ECG) is a fundamental modality to help determine the mechanism and the localization of atrial tachycardias (ATs). Although macroreentrant ATs and focal ATs typically show F-waves and discrete P-waves respectively on the 12-lead ECG, this is not universally the case in scar-related ATs.1, We present three cases clearly showing the discrepancy between the AT morphology on the 12-lead ECG and the AT-mechanism.


Assuntos
Ablação por Cateter , Taquicardia Atrial Ectópica , Taquicardia Supraventricular , Humanos , Cicatriz , Eletrocardiografia
17.
Heart ; 109(5): 364-371, 2023 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-36396438

RESUMO

OBJECTIVE: We aimed to compare cryoballoon pulmonary vein isolation (PVI) with standard radiofrequency cavotricuspid isthmus (CTI) ablation as first-line treatment for typical atrial flutter (AFL). METHODS: Cryoballoon Pulmonary Vein Isolation as First-Line Treatment for Typical Atrial Flutter was an international, multicentre, open with blinded assessment trial. Patients with CTI-dependent AFL and no documented atrial fibrillation (AF) were randomised to either cryoballoon PVI alone or radiofrequency CTI ablation. Primary efficacy outcome was time to first recurrence of sustained (>30 s) symptomatic atrial arrhythmia (AF/AFL/atrial tachycardia) at 12 months as assessed by continuous monitoring with an implantable loop recorder. Primary safety outcome was a composite of death, stroke, tamponade requiring drainage, atrio-oesophageal fistula, pacemaker implantation, serious vascular complications or persistent phrenic nerve palsy. RESULTS: Trial recruitment was halted at 113 of the target 130 patients because of the SARS-CoV-2 pandemic (PVI, n=59; CTI ablation, n=54). Median age was 66 (IQR 61-71) years, with 98 (86.7%) men. At 12 months, the primary outcome occurred in 11 (18.6%) patients in the PVI group and 9 (16.7%) patients in the CTI group. There was no significant difference in the primary efficacy outcome between the groups (HR 1.11, 95% CI 0.46 to 2.67). AFL recurred in six (10.2%) patients in the PVI arm and one (1.9%) patient in the CTI arm (p=0.116). Time to occurrence of AF of ≥2 min was significantly reduced with cryoballoon PVI (HR 0.46, 95% CI 0.25 to 0.85). The composite safety outcome occurred in four patients in the PVI arm and three patients in the CTI arm (p=1.000). CONCLUSION: Cryoballoon PVI as first-line treatment for AFL is equally effective compared with standard CTI ablation for preventing recurrence of atrial arrhythmia and better at preventing new-onset AF. TRIAL REGISTRATION NUMBER: NCT03401099.


Assuntos
Fibrilação Atrial , Flutter Atrial , COVID-19 , Ablação por Cateter , Veias Pulmonares , Taquicardia Supraventricular , Masculino , Humanos , Idoso , Feminino , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Flutter Atrial/epidemiologia , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , COVID-19/complicações , SARS-CoV-2 , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/epidemiologia , Resultado do Tratamento , Recidiva
19.
Eur Heart J Case Rep ; 6(8): ytac304, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35965604

RESUMO

Background: Transcatheter left atrial appendage (LAA) closure (LAAc) is less feasible in patients with unusual LAA anatomy. Case summary: A 65-year-old woman with persistent atrial fibrillation was referred for LAAc. Transesophageal echocardiography (TEE) revealed spontaneous contrast in the LAA without formation of a thrombus; the LAA shape was tortuous and difficult to assess. A first LAAc procedure was unsuccessful given the unsuitable sheath position. Therefore, a soft three-dimensional (3D) model printing was performed by laser sintering and revealed excessive sheath kinking with an inferior approach, but successful deployment would be feasible using a superior approach. Successful trans-jugular implantation of a Watchman FLX 31 device in stable position without residual leakage was achieved during the subsequent procedure. At 3-month follow-up, and after cessation of oral anticoagulation, the patient's symptoms improved. Imaging demonstrated complete LAA occlusion and correct placement of the device along the LAA superior axis. Discussion: This is the first-reported clinical case of a complex transcatheter LAAc through a trans-jugular approach. Simulating the patient's anatomy with a laser sintering 3D-printed model showed why the transfemoral approach failed, validated the trans-jugular procedure, enabled selection of the simple curve access sheath that had the most direct trajectory towards the LAA, confirmed that transseptal puncture was possible, allowed determination of the angle of puncture, enabled selection of the most appropriate LAA device and had a very low cost compared with planning software or other printing methods.

20.
J Interv Card Electrophysiol ; 65(2): 509-518, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35794439

RESUMO

PURPOSE: Local impedance (LI) measurement from an ablation catheter is useful in predicting lesion size and acute success of pulmonary vein isolation (PVI). The LI variation can be described by absolute LI drop (ΔLID) or ΔLID/initial LI (%LID). We evaluated the utility of these parameters in predicting acute lesion durability during PVI using a novel catheter capable of measuring both LI and contact force (CF). METHODS: PVI with a targeted CF, power, and duration was performed in 23 consecutive patients with paroxysmal atrial fibrillation. LI was blinded to operators during ablation. Parameters for each RF application were collected and compared for acute successful lesions and gaps. RESULTS: A total of 1633 RF applications including 97 (5.9%) gap lesions were analyzed. Successful lesions were more frequently observed at non-carinal sites and those with higher contact force, FTI, initial LI, and larger variation of LI and generator impedance (GI). Multivariate analysis demonstrated that absolute GI drop (ΔGID) [OR 1.09 (1.04-1.15), p < 0.001], ΔLID [1.12 (1.09-1.16), p < 0.001], ΔGID/initial GI (%GID) [OR 1.04 (1.01-1.07), p = 0.01], and %LID [OR 1.15 (1.12-1.28), p < 0.001] were significantly associated with successful lesions, and carinal site [OR 0.15(0.09-0.24), p < 0.001] was significantly related to gaps. Both ΔLID and %LID equally predicted the acute durability of lesions during PVI. ΔLID ≥ 24Ω and %LID ≥ 15% at the carina, and ΔLID ≥ 21Ω and %LID ≥ 14% at non-carinal sites significantly predicted acute successful lesions with negative predictive values of 93-99%. CONCLUSIONS: Both ΔLID and %LID were equally useful in predicting acute successful lesions during PVI. Larger cut-off values should be applied to carinal sites.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Impedância Elétrica , Fibrilação Atrial/cirurgia , Catéteres , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...