Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Biomed Mater Res B Appl Biomater ; 105(1): 211-221, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-26380916

RESUMO

Glaucoma is the second leading cause of blindness with ∼70 million people worldwide who are blind from this disease. The currently practiced trabeculectomy surgery, the gold standard treatment used to stop the progression of vision loss, is rather draconian, traumatic to the patient and requires much surgical skill to perform. This article summarizes the more than 10-year development path of a novel device called the InnFocus MicroShunt®, which is a minimally invasive glaucoma drainage micro-tube used to shunt aqueous humor from the anterior chamber of the eye to a flap formed under the conjunctiva and Tenon's Capsule. The safety and clinical performance of this device approaches that of trabeculectomy. The impetus to develop this device stemmed from the invention of a new biomaterial called poly(styrene-block-isobutylene-block-styrene), or "SIBS." SIBS is ultra-stable with virtually no foreign body reaction in the body, which manifests in the eye as clinically insignificant inflammation and capsule formation. The quest for an easier, safer, and more effective method of treating glaucoma led to the marriage of SIBS with this glaucoma drainage micro-tube. This article summarizes the development of SIBS and the subsequent three iterations of design and four clinical trials that drove the one-year qualified success rate of the device from 43% to 100%. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 211-221, 2017.


Assuntos
Glaucoma/cirurgia , Estirenos , Animais , Coelhos , Estirenos/química , Estirenos/farmacologia
2.
Regen Biomater ; 3(2): 137-42, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27047682

RESUMO

The InnFocus MicroShunt® is a minimally invasive glaucoma drainage microtube used to shunt aqueous humor from the anterior chamber of the eye to a flap formed under the conjunctiva and Tenon's capsule. The safety and clinical performance of this device approaches that of trabeculectomy with mitomycin C, the current 'gold standard' treatment for advanced glaucoma. The invention of a new biomaterial called poly(styrene-block-isobutylene-block-styrene) or 'SIBS' is the enabling factor which led to the success of this product. SIBS is ultrastable with virtually no foreign body reaction in the body, which manifests as clinically insignificant inflammation and capsule formation in the eye. The lack of capsule formation enables unobstructed flow through the 70 µm lumen tube and the achievement of controlled low intraocular pressure, which is important for the management of glaucoma. This article summarizes the integration of SIBS into a glaucoma drainage device and confirms its functionality with clinical success over a 2-year period.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...