Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Heart Rhythm ; 6(1): 65-8, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19121802

RESUMO

BACKGROUND: With the increased number of implantable cardioverter-defibrillator (ICD) recipients and the frequent need for device upgrading, lead malfunction is a concern, but the optimal approach to managing nonfunctioning leads is unknown. OBJECTIVE: The purpose of this study was to determine the rate and characteristics of complications related to abandoned ICD leads. METHODS: Patients with abandoned leads were identified by retrospective review of the Mayo Clinic ICD database from August 1993 to May 2002. We reviewed the medical records to assess long-term follow-up for venous thromboembolic complications, device sensing malfunction, appropriateness of delivered shocks, defibrillation threshold (DFT) values before and after lead abandonment, and subsequent surgical procedures related to devices or leads. RESULTS: We identified 78 ICD patients (81% males; mean age 63 +/- 14 years) with 101 abandoned leads (69 in the right ventricle, 31 in the right atrium or superior vena cava, 1 in the coronary sinus). During a mean follow-up of 3.1 +/- 2.0 years, neither sensing malfunction nor venous thromboembolic complications were detected. DFT values were high in 13 patients (17%), but there was no significant increase in mean DFT values before and after lead abandonment in 43 patients for whom both values were available (16.2 +/- 9.2 J before abandonment vs 14.1 +/- 5.5 J after; P = .24). Fourteen patients (18%) required further ICD-related surgery; none of these operations were attributed to abandoned leads. Five-year rates of appropriate and inappropriate shocks were 25.9% and 20.5%, respectively. CONCLUSION: Abandoning a nonfunctioning lead appears to be safe and does not pose a clinically significant additional risk of future complications.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/instrumentação , Endocárdio/cirurgia , Tromboembolia/prevenção & controle , Desenho de Equipamento , Falha de Equipamento , Segurança de Equipamentos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Tromboembolia/etiologia , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...