Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Chromatogr A ; 1611: 460619, 2020 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-31668415

RESUMO

Iron-free HPLC systems, better known as biocompatible systems, are generally regarded to be chemically more inert compared to conventional HPLC systems. In this work, we studied the chromatographic behavior of some classes of compounds of pharmaceutical interest, analyzed with iron-free systems. Issues typically associated with metal contamination, i.e. strong peak tailing, were observed when using an amide polar-embedded column. Effects of the contamination were visible when anhydrous methanol-acetonitrile was used, indicating that this solvent, albeit generally considered safe for conventional HPLC systems, induce corrosion of iron-free systems. The confirmation of titanium as main acting contaminant came from systematically studying the contribution of each wetted component of the HPLC system on peak shape of affected molecules. Quantification of titanium by ICP-MS analysis of effluents provided further evidence on the source of contamination. A mechanistic description of the complex interaction between titanium ions, organic molecules, and column stationary phase is proposed. In the perspective of developing methods that are fully portable between stainless steel and titanium systems, recommendations are given in terms of potentially sensitive molecules, suitable mobile phase conditions, and type of column to be used.


Assuntos
Quelantes/análise , Cromatografia Líquida de Alta Pressão/métodos , Ferro/química , Preparações Farmacêuticas/análise , Titânio/análise , Compostos de Anilina/química , Ciprofloxacina/análise , Sais/química
2.
Anal Bioanal Chem ; 404(2): 433-45, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22669308

RESUMO

Determination of trace constituents in biological and environmental samples usually requires a pre-concentration step. While solid-phase extraction (SPE) has been widely used, it is slow, labor intensive and adversely affected by analytical errors from handling. On-line SPE eliminates some of the flaws but often suffers from solvent compatibility problems with the subsequent chromatography separation. In this study, we are presenting a technical solution for overcoming some of these compatibility issues, by utilizing a fully automated, focused SPE sample transfer technique utilizing narrow-band solvent plugs, for seamless hyphenation with high-performance liquid chromatography (HPLC) or flow injection mass spectrometry (MS). A wide range of pharmaceutical compounds was studied in different sample matrices. Short plugs of high elution strength solvent were generated by means of an electrically actuated sample loop and enrichment and transfer steps monitored using on-line SPE-MS. The impact of the solvent plugs on chromatographic separation was studied using hyphenated SPE-LC-MS. By carefully examining elution profiles of solvent plugs of different compositions, optimum conditions for quantitative elution within well-defined volumes were found for all substances. In addition, the highly focused elution bands resulted in excellent retention time and peak area reproducibilities when injected on-line onto HPLC columns. Finally, to demonstrate proof-of-principle, the fully integrated on-line SPE-LC-MS system was applied to the analysis of spiked urine and river water samples.


Assuntos
Extração em Fase Sólida , Solventes/química , Cromatografia Líquida de Alta Pressão , Espectrometria de Massas
3.
Electrophoresis ; 31(7): 1248-1255, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20196030

RESUMO

In drug development, the combinatorial synthesis of drug libraries is common use, therefore efficient tools for the characterization of drug candidates and the extent of interaction between a drug and its target protein is a central question of analytical interest. While biological activity is tested today by enzyme assays, MS techniques attract more and more attention as an alternative for a rapid comparison of drug-target interactions. CE enables the separation of proteins and drug-enzyme complexes preserving their physiological activity in aqueous media. By hyphenating CE with ESI-MS/MS, the binding strength of enzyme inhibitors can be deduced from MS/MS experiments, which selectively release the inhibitor from the drug-target complex after CID. In this study, alpha-chymotrypsin (CT), a serine protease, was chosen as a model compound. Chymostatin is a naturally occurring peptide aldehyde binding to CT through a hemiacetal bond and electrostatic interaction. First, a CE separation was developed, which allows the analysis of alpha-CT and a chymotrypsin-chymostatin complex under MS-compatible conditions. The use of neutral-coated CE capillaries was mandatory to reduce analyte-wall interactions. ESI-quadrupole ion trap-MS was worked out to demonstrate the selective drug release after CID. Fragmentation of the drug-enzyme complex was monitored in dependence from the excitation energy in the ion trap, leading to the V(50) voltage that enables 50% complex fragmentation as a reference value for chymotrypsin-chymostatin complex. A stable CE-ESI-MS/MS setup was established, which preserves the drug-enzyme complexes during ionization-desolvation processes. With this optimized setup, different CT inhibitors could be investigated and compared.


Assuntos
Eletroforese Capilar/métodos , Mapeamento de Interação de Proteínas/métodos , Espectrometria de Massas em Tandem/métodos , Soluções Tampão , Quimotripsina/química , Quimotripsina/metabolismo , Concentração de Íons de Hidrogênio , Oligopeptídeos/química , Oligopeptídeos/metabolismo , Concentração Osmolar , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...