Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 6036-6039, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31947222

RESUMO

A high-precision wearable bioimpedance sensor developed at Imec was extensively tested. Unlike known bioimpedance sensors on the market, the new device enables hydration shift measurement in a single person, with no need for averaging over a population. For reaching this target, a method for hydration monitoring in case of altered hydration is tested. An assessment of fluid shift with sensitivity of about 700 ml has been demonstrated, which is comparable with the capabilities of known methods because of the device accuracy, immunity to electrode-skin impedance variation, and due to establishing the impedance baseline prior to fluid shift.


Assuntos
Corpo Humano , Composição Corporal , Impedância Elétrica , Eletrodos , Humanos , Pele