Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
1.
Materials (Basel) ; 17(11)2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38893867

RESUMO

The manufacturing of orthodontic archwires made from NiTi alloy has undergone numerous changes from the second half of the last century to modern times. Initially, superelastic-active austenitic NiTi alloys were predominant, followed by thermodynamic-active martensitic NiTi alloys, and, finally, the most recent development was graded thermodynamic alloys. These advancements have been the subject of extensive investigation in numerous studies, as they necessitated a deeper understanding of their properties. Furthermore, it is imperative that we validate the information provided by manufacturers regarding these archwires through independent studies. This review evaluates existing studies on the subject with a specific focus on the Bio-active multi-force NiTi archwire, by examining its mechanical, thermal, and physicochemical properties before and after clinical use. This archwire consists primarily of Ni and Ti, with traces of Fe and Cr, which release graduated, biologically tolerable forces which increase in a front-to-back direction and are affected by the temperature of the environment they are in. The review provides information to practicing orthodontists, facilitating informed decisions regarding the selection and use of Bio-active™ archwires for individual patient treatments.

2.
Arch Oral Biol ; 164: 105983, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38718467

RESUMO

OBJECTIVES: This study aimed to investigate the relationship between the aspect ratios of mandibular molar roots at the apical 3-mm level and their root canal complexity. DESIGN: This study used micro-CT imaging to analyze 163 two-rooted mandibular molars. The aspect ratios of the roots at the apical 3-mm level were categorized as "< 2.75" or "≥ 2.75" (mesial) and "< 1.75" or "≥ 1.75" (distal). A two-dimensional (2D) analysis focused on four apical axial cross-section levels to determine the presence of main and accessory canals and isthmus. Additionally, a three-dimensional (3D) assessment of the apical 4-mm of both roots examined main and accessory canals, apical foramina, apical deltas, and middle mesial canals. RESULTS: Mesial roots with aspect ratios ≥ 2.75 showed a higher number of main canals at all levels compared to those with aspect ratios < 2.75 at the 3-mm level. Additionally, the ≥ 2.75 group exhibited more accessory canals and a higher average number of accessory canals. The 3D assessment confirmed significantly more accessory canals and apical foramina in the ≥ 2.75 group. The prevalence of roots with apical deltas was nearly double in the ≥ 2.75 group, and middle mesial canals were exclusively found in this group. In the distal root, the ≥ 1.75 group showed a significantly higher number of main canals at all axial levels. No significant differences were observed between groups in terms of accessory canals, apical foramina, or deltas. CONCLUSIONS: A higher root aspect ratio is related to higher anatomical complexity.


Assuntos
Cavidade Pulpar , Mandíbula , Dente Molar , Raiz Dentária , Microtomografia por Raio-X , Microtomografia por Raio-X/métodos , Humanos , Dente Molar/diagnóstico por imagem , Dente Molar/anatomia & histologia , Mandíbula/diagnóstico por imagem , Mandíbula/anatomia & histologia , Raiz Dentária/diagnóstico por imagem , Raiz Dentária/anatomia & histologia , Cavidade Pulpar/anatomia & histologia , Cavidade Pulpar/diagnóstico por imagem , Imageamento Tridimensional/métodos , Ápice Dentário/diagnóstico por imagem , Ápice Dentário/anatomia & histologia
3.
Materials (Basel) ; 17(10)2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38793413

RESUMO

The resistance of nickel-titanium endodontic instruments against cyclic fatigue failure remains a significant concern in clinical settings. This study aimed to assess the cyclic fatigue strength of five nickel-titanium rotary systems, while correlating the results with the instruments' geometric and metallurgical characteristics. A total of 250 new instruments (sizes S1/A1, S2/A2, F1/B1, F2/B2, F3/B3) from ProTaper Gold, ProTaper Universal, Premium Taper Gold, Go-Taper Flex, and U-Files systems underwent mechanical testing. Prior to experimental procedures, all instruments were meticulously inspected to identify irregularities that could affect the investigation. Using a stereomicroscope, design characteristics such as the number of spirals, length, spirals per millimeter, and average helical angle of the active blade were determined. The surface finishing characteristics of the instruments were examined using a scanning electron microscope. Differential scanning calorimetry was employed to establish the instruments' phase transformation temperatures, while energy-dispersive X-ray spectroscopy was utilized to analyze the elemental composition of the alloy. The instruments were subjected to cyclic fatigue testing within a stainless steel non-tapered artificial canal featuring a 6 mm radius and 86 degrees of curvature. Appropriate statistical tests were applied to compare groups, considering a significance level of 0.05. The assessed design characteristics varied depending on the instrument type. The least irregular surface finishing was observed in U-Files and Premium Taper Gold files, while the most irregular surface was noted in Go-Taper Flex. All instruments exhibited near-equiatomic proportions of nickel and titanium elements, whereas ProTaper Universal and U-Files instruments demonstrated lower phase transformation temperatures compared to their counterparts. Larger-sized instruments, as well as ProTaper Universal and U-Files, tended to display lower cyclic fatigue strength results. Overall, the design, metallurgical, and cyclic fatigue outcomes varied among instruments and systems. Understanding these outcomes may assist clinicians in making more informed decisions regarding instrument selection.

4.
Dent J (Basel) ; 12(4)2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38668010

RESUMO

Small-sized stainless steel hand files are conventionally employed in root canal treatment procedures for canal scouting and for glide path establishment, owing to their superior flexibility and proficiency in navigating confined spaces. Given the diversity of brands available in the market, there exists potential variability in their physical characteristics, thereby influencing clinical performance. Consequently, this study aims to conduct a comparative analysis of the design, metallurgy, and mechanical characteristics among seven stainless steel hand file brands across ISO sizes 06, 08, and 10. A total of 315 new 25 mm length stainless steel hand files with apical sizes of 0.06, 0.08, and 0.10 from seven distinct brands were included in the study. A meticulous inspection of all instruments was undertaken to identify any structural deformations that might render them ineligible for the study. The design inspection involved the random selection of instruments from each group, which were examined under various microscopes, including a dental operating microscope, optical microscope, and scanning electron microscope. Furthermore, two instruments from each group underwent energy-dispersive X-ray spectroscopy analysis for elemental composition documentation. Mechanical tests were conducted to evaluate the instruments' resistance to lateral deformation (buckling) and their microhardness. Statistical analysis was executed using the nonparametric Mood's median test, with a predetermined significance level of 0.05. Regarding the instruments design, all files exhibited an active blade length ranging from 16 to 17 mm. However, variations were observed in the number of spirals, tip designs, and sizes, with the API K-File notably larger in sizes 0.06 and 0.08 compared to the other instruments. Despite uniform elements composition, differences in geometric features and mechanical properties were evident. Concerning buckling strength, the API K-File demonstrated superior performance across all tested sizes, while the Dentsply ReadySteel, SybronEndo, and Mani K-Files exhibited lower results (p < 0.05). In microhardness assessments, both the API and Oro K-Files displayed the lowest outcomes, with medians of 531 HVN and 532 HVN, respectively, whereas the SybronEndo K-File exhibited the highest microhardness (657 HVN). Despite similar metallurgical composition, the observed distinctions in geometric features and mechanical properties underscore the impact of the manufacturing process on the characteristics of glide path stainless steel endodontic files. These disparities may ultimately influence their clinical performance.

5.
Clin Oral Investig ; 28(3): 201, 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38453706

RESUMO

OBJECTIVES: The aim of this study was to assess cone beam computed tomography (CBCT) as a root canal anatomy diagnostic tool by comparison with micro-CT gold-standard. MATERIALS AND METHODS: 216 two-rooted mandibular molars were first scanned in a CBCT device (200 µm voxel size) and posteriorly in a micro-CT scanner (19.61 µm). The volumes were sequentially screened to classify main root canal anatomy according to Vertucci classification, and for the presence of lateral canals and apical deltas, in both mesial and distal roots. RESULTS: Both methods revealed a higher prevalence of Vertucci Type II and IV in the mesial root, and Vertucci Type I in the distal root. The percentage of agreement for main root canal anatomy classification between CBCT and micro-CT scores was high (85.2%). CONCLUSION: Sensibility to detect both lateral canals and apical deltas with CBCT was low. These results attest to the fact that minor anatomical changes might be difficult to identify with CBCT imaging, hampering its diagnostic value.


Assuntos
Cavidade Pulpar , Mandíbula , Cavidade Pulpar/diagnóstico por imagem , Cavidade Pulpar/anatomia & histologia , Microtomografia por Raio-X , Mandíbula/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Raiz Dentária/diagnóstico por imagem , Raiz Dentária/anatomia & histologia
6.
Dent J (Basel) ; 12(2)2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38392233

RESUMO

To establish a glide path, smaller files (up to size 0.15) with tapers of 2% are commonly used as pathfinding files. They pre-shape the root canal space before transitioning to larger taper endodontic instruments, aiming to prevent procedural errors. This study aimed to compare the design, metal wire composition, and mechanical characteristics of seven different ISO size 15 stainless-steel hand files (K-File and C-File+). Ninety-one new stainless-steel ISO 15 K-files were mechanically tested. All files were inspected for deformations before the assessment. Dental operating microscope, scanning electron microscope (SEM), and optical microscope analyses were conducted on four randomly selected instruments from each group, and two instruments per group underwent an energy-dispersive X-ray spectroscopy (EDS) analysis. Buckling mechanical tests were performed using an Instron universal testing machine, and microhardness was assessed using a Vickers hardness tester. The statistical analysis employed the nonparametric Mood's median test, with a significance level set at 0.05. The instrument design analysis unveiled variations in the active blade area length and the number of spirals, while maintaining consistent cross-sections and symmetrical blades. Distinct tip geometries and surface irregularities were observed. While the energy-dispersive X-ray spectroscopy confirmed similar compositions, the buckling strength and microhardness values exhibited variability across for all tested files. Notably, the Dentsply ReadySteel C-File+ recorded the highest buckling value (2.10 N), and the Dentsply ReadySteel K-File exhibited the lowest (1.00 N) (p < 0.05). Moreover, the Dentsply ReadySteel K-File recorded the highest microhardness value (703 HVN), while the SybronEndo Triple-Flex had the lowest (549 HVN) (p < 0.05). While similarities in cross-section design and metal wire composition were noted among the files, variations in the number of spirals and mechanical performance were also observed. Thus, all of these factors should be considered when selecting suitable files for an efficient root canal treatment.

7.
Int Endod J ; 57(5): 601-616, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38376108

RESUMO

AIM: To compare eight large- and low-tapered heat-treated reciprocating instruments regarding their design, metallurgy, mechanical properties, and irrigation flow through an in silico model. METHODOLOGY: A total of 472 new 25-mm E-Flex Rex (25/.04 and 25/.06), Excalibur (25/.05), Procodile (25/.06), Reciproc Blue R25 (25/.08v), WaveOne Gold Primary (25/.07v), and Univy Sense (25/.04 and 25/.06) instruments were evaluated regarding their design (stereomicroscopy, scanning electron microscopy, and 3D surface scanning), metallurgy (energy-dispersive X-ray spectroscopy and differential scanning calorimetry), and mechanical performance (cyclic fatigue, torsional resistance, cutting ability, bending and buckling resistance). Computational fluid dynamics assessment was also conducted to determine the irrigation flow pattern, apical pressure, and wall shear stress in simulated canal preparations. Kruskal-Wallis and one-way anova post hoc Tukey tests were used for statistical comparisons (α = 5%). RESULTS: Instruments presented variations in blade numbers, helical angles, and tip designs, with all featuring non-active tips, symmetrical blades, and equiatomic nickel-titanium ratios. Cross-sectional designs exhibited an S-shaped geometry, except for WaveOne Gold. Univy 25/.04 and Reciproc Blue displayed the smallest and largest core diameters at D3. Univy 25/.04 and E-Flex Rec 25/.04 demonstrated the longest time to fracture (p < .05). Reciproc Blue and Univy 25/.04 exhibited the highest and lowest torque to fracture, respectively (p < .05). Univy 25/.04 and Reciproc Blue had the highest rotation angles, whilst E-Flex Rec 25/.06 showed the lowest angle (p < .05). The better cutting ability was observed with E-Flex Rec 25/.06, Procodile, Excalibur, and Reciproc Blue (p > .05). Reciproc R25 and E-Flex Rec showed the highest buckling resistance values (p < .05), with WaveOne Gold being the least flexible instrument. The impact of instruments' size and taper on wall shear stress and apical pressure did not follow a distinct pattern, although Univy 25/.04 and E-Flex Rec 25/.06 yielded the highest and lowest values for both parameters, respectively. CONCLUSIONS: Low-tapered reciprocating instruments exhibit increased flexibility, higher time to fracture, and greater angles of rotation, coupled with reduced maximum bending loads and buckling strength compared to large-tapered instruments. Nevertheless, low-tapered systems also exhibit lower maximum torque to fracture and inferior cutting ability, contributing to a narrower apical canal enlargement that may compromise the penetration of irrigants in that region.


Assuntos
Instrumentos Odontológicos , Titânio , Estudos Transversais , Desenho de Equipamento , Teste de Materiais , Estresse Mecânico , Titânio/química , Preparo de Canal Radicular , Metalurgia
8.
J Endod ; 50(4): 456-471, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38280512

RESUMO

INTRODUCTION: This study aimed to examine the global prevalence of root and root canal morphologies in mandibular canines and analyze potential influences of region, ethnicity, sex, and age on the proportion of a second root and root canal configuration. METHODS: Observers from 44 countries screened 13,200 canines using cone-beam computed tomographic exams and gathered data on the percentages of 2 root canal morphologies and 2-rooted configurations (primary outcomes), as well as the root canal configurations (secondary outcome). Demographic factors (ethnicity, sex, and age) were collected for each participant. Primary outcomes were represented as odds ratios and untransformed proportions accompanied by 95% confidence interval (CI) forest plots. Meta-analysis compared subgroups and identified sources of heterogeneity. Intra- and inter-rater tests were conducted. Statistical significance was set at 5%. RESULTS: The worldwide prevalence of a second canal was 7.5% (95% CI, 6.3%-8.7%), ranging from 0.7% in Nigeria to 17.7% in Uruguay. The meta-analysis also revealed significant variations when comparing ethnicity, gender, and age (P < .05). The global prevalence of a second root was 1.9% (95% CI, 1.5%-2.3%), with the highest proportion observed in Spain (6.7%). Caucasian and Indian (south Asian) ethnic groups, females, and older patients exhibited higher proportions of 2 roots (P < .05). Meta-regression excluded side, voxel size, and field of view as sources of heterogeneity (P > .05). CONCLUSIONS: The prevalence of 2 root canals and 2-rooted configurations in the mandibular canine exhibited variations based on geographic location, ethnicity, sex, and age. The global prevalence of 2 root canals and 2-root configuration was 7.5% and 1.9%, respectively.


Assuntos
Cavidade Pulpar , Raiz Dentária , Feminino , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Estudos Transversais , Cavidade Pulpar/anatomia & histologia , Mandíbula/diagnóstico por imagem , Estudos Multicêntricos como Assunto , Tratamento do Canal Radicular , Raiz Dentária/anatomia & histologia , População Branca , População do Sul da Ásia
10.
Aust Endod J ; 50(1): 40-51, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37849412

RESUMO

This study aims to assess the influence of root canal preparation, irrigation needle design and its placement depth in the irrigation flow of confluent canals during syringe irrigation. A mandibular molar presenting two confluent canals in its mesial root was sequentially prepared and scanned by micro-computed tomography after mechanical preparation up to ProTaper Next system sizes X2 (25/.06v), X3 (30/.07v) and X4 (40/.06v). In each of the root canal preparation models, a side-vented and an open-ended needle at 5, 3 and 2 mm from the working length were included, and irrigation flow was assessed by a validated computational fluid dynamics model. The results revealed that the irrigant flowed out of the confluent canals mainly through the canal that did not have the needle. Apical penetration and renewal of the irrigant were most efficiently achieved with the use of a 30G open-ended needle and a 30/.07v preparation.


Assuntos
Cavidade Pulpar , Hidrodinâmica , Cavidade Pulpar/diagnóstico por imagem , Microtomografia por Raio-X , Seringas , Irrigantes do Canal Radicular , Irrigação Terapêutica , Preparo de Canal Radicular
11.
J Endod ; 50(1): 31-54, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37898333

RESUMO

INTRODUCTION: This worldwide study examined the root and root canal characteristics of maxillary premolars and explored how demographic factors impact the outcomes. METHODS: Observers from 44 countries assessed 26,400 maxillary premolars using cone-beam computed tomography and employed a standardized screening method to gather data on multiple canal morphology and 3-rooted configuration (primary outcomes), as well as secondary outcomes related to root and root canal anatomies. Demographic factors such as ethnicity, sex, and age were collected for each participant. The intra- and inter-observer tests ensured observer reliability. Primary outcomes were represented as odds ratios and untransformed proportions accompanied by 95% confidence interval (CI) forest plots. Meta-analysis compared sub-groups and identified sources of heterogeneity (α = 5%). RESULTS: The overall prevalence of multiple canal morphology in the first premolar was 93.5% (95% CI, 93.3%-94.7%), while in the second premolar, it was 49.7% (95% CI, 44.9%-54.6%). The proportion of 3-rooted configuration was 1.8% (95% CI, 1.4%-2.1%) in the first premolar and 0.4% (95% CI, 0.3%-0.5%) in the second. Asian countries generally displayed fewer roots and root canals, while European nations showed higher counts (P < .05). Males exhibited higher percentages and odds ratios for both outcomes in both premolars. Younger patients demonstrated lower percentages of multiple root canal morphologies (P < .05). Factors such as tooth side, voxel size and field-of-view did not influence the outcomes (P > .05). CONCLUSIONS: The worldwide assessment of root and root canal characteristics of maxillary premolars has revealed a discernible influence of various factors such as tooth type, geographical region, ethnicity, sex, and age.


Assuntos
Cavidade Pulpar , Raiz Dentária , Masculino , Humanos , Cavidade Pulpar/diagnóstico por imagem , Cavidade Pulpar/anatomia & histologia , Dente Pré-Molar/diagnóstico por imagem , Dente Pré-Molar/anatomia & histologia , Estudos Transversais , Reprodutibilidade dos Testes , Raiz Dentária/diagnóstico por imagem , Raiz Dentária/anatomia & histologia , Maxila/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Estudos Multicêntricos como Assunto
12.
Int Endod J ; 56(11): 1412-1428, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37698946

RESUMO

AIM: To compare the design, metallurgy, and mechanical properties of four heat-treated reciprocating instruments coupled with the evaluation of the irrigation flow using an in silico model. METHODOLOGY: New EdgeOne Fire Primary, Easy-File Flex Regular 25, WaveOne Gold Primary and Reciproc Blue R25 instruments (n = 124) were initially evaluated regarding their design through stereomicroscopy, scanning electron microscopy and 3D surface scanning. In addition, energy-dispersive X-ray spectroscopy was utilized to determine their elemental composition, and differential scanning calorimetry tests to evaluate their phase transformation temperatures. Their mechanical performance was further assessed through torsional and bending tests. Using scans obtained from a real tooth and the instruments, a computational fluid dynamics assessment was conducted to determine the irrigation flow pattern, apical pressure, and wall shear stress in simulated canal preparation. Mood's median and One-way anova post hoc Tukey tests were used for statistical comparisons (α = 5%). RESULTS: Reciproc Blue exhibited a superior number of blades (n = 8), whereas EdgeOne Fire had the highest overall volume (4.38 mm3 ) and surface area (32.32 mm2 ). At the 3-mm axial level, EdgeOne Fire displayed the lowest core diameter (0.13 mm), while Reciproc Blue had the highest (0.16 mm). All blades were symmetrical, and the tips of the instruments were non-active but differed from each other. The most irregular surfaces were observed in EdgeOne Fire and Easy-File Flex. All instruments were manufactured from nickel-titanium alloys and exhibited distinct phase transformation temperatures. WaveOne Gold and Reciproc Blue demonstrated the highest maximum torque values (1.87 and 1.62 N cm, respectively), while the lowest was observed on EdgeOne Fire (1.21 N cm) (p < .05). The most flexible (p < .05) were EdgeOne Fire (angle of rotation: 602.6°; maximum bending load: 251.4 g.f) and Reciproc Blue (533.2° and 235.6 g.f). There were no significant differences observed in the irrigation flow among the four domains generated by the tested instruments. CONCLUSIONS: Despite observing variations in the design, phase transformation temperatures, and in the torsional and bending test outcomes among the four heat-treated reciprocating instruments, no significant differences were found in the irrigation flow pattern among the different groups in the simulated root canal preparations.


Assuntos
Instrumentos Odontológicos , Temperatura Alta , Desenho de Equipamento , Estresse Mecânico , Preparo de Canal Radicular , Titânio/química , Metalurgia , Ouro , Teste de Materiais
13.
Int Endod J ; 56(10): 1301-1315, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37594701

RESUMO

AIM: To assess the influence of a flat-side design on the geometry, metallurgy, mechanical performance and shaping ability of a novel nickel-titanium rotary instrument. METHODOLOGY: Sixty-five new 25-mm flat-side rotary instruments (size 25, taper 0.04) and their nonflat-side prototypes (n = 65) were assessed for major deformations and examined regarding macroscopic and microscopic design, determination of nickel and titanium elements ratio, measurement of phase transformation temperature and evaluation of mechanical performance parameters including time/cycles to fracture, maximum torque, angle of rotation, maximum bending and buckling strengths and cutting ability. Additionally, unprepared canal areas, volume of hard tissue debris and percentage reduction of dentine thickness were calculated for each tested instrument after preparing mesial canals of mandibular molars (n = 12), using micro-CT imaging. Statistical analyses were performed using the U-Mann-Whitney test and independent Student t-test (α = 5%). RESULTS: The number of spirals (n = 8) and blade direction (clockwise) were similar between both flat and nonflat instruments, whilst the helical angles were equivalent (⁓25°). Flat-instruments showed inconsistencies in the homogeneity of the gold colour on the flat-side surface, blade discontinuity, and incomplete and variable S-shaped cross-sections. The titanium-to-nickel ratios were equivalent, but significant differences in the R-phase finish and austenitic start phase transformation temperatures were observed between the flat and nonflat-side instruments. The flat-side instruments demonstrated superior cutting ability compared to the nonflat instruments, as well as, significantly lower values for time to fracture, rotation to fracture and maximum torque to fracture (p < .001). No statistical difference was observed between tested instruments regarding angle of rotation (p = .437), maximum bending (p = .152) and buckling load (p = .411). Preparation protocols using flat and nonflat instruments did not show any statistically significant differences (p > .05). All flat-side instruments exhibited deformation after shaping procedures. CONCLUSIONS: The flat-side instrument showcased enhanced cutting ability compared to its nonflat counterpart. However, it exhibited inferior performance in terms of time, rotation and maximum torque to fracture, along with distinct phase transformation temperatures. No differences were observed in the titanium-to-nickel ratios, angle of rotation, maximum bending, buckling load, preparation time, percentage of untouched canal walls, volume of hard tissue debris and percentage reduction of dentine thickness.


Assuntos
Níquel , Titânio , Humanos , Cavidade Pulpar , Metalurgia , Dente Molar
14.
J Endod ; 49(9): 1207-1215, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37468061

RESUMO

The loss of periodontal tissue support and vertical buccal bone loss in apico-marginal defects can often be mistaken for features indicative of vertical root fractures and this study reports thirteen cases with persistent symptomatic apical periodontitis, apico-marginal defects, and large periapical lesions that were managed with endodontic microsurgery in conjunction with bone grafts and barrier placements with a follow-up period of up to 9 years. At the recall sessions, all cases were asymptomatic with radiographical success with only 2 cases exhibiting residual apical radiolucency, but with evident reduction in the lesion size, indicative of healing. This study highlights the potential of utilizing endodontic microsurgery combined with guided tissue regeneration that proved effective in stimulating the regeneration of periodontal tissue in cases of apico-marginal defects that can lead to favourable long-term outcomes.


Assuntos
Microcirurgia , Periodontite Periapical , Humanos , Regeneração Tecidual Guiada Periodontal , Periodontite Periapical/diagnóstico por imagem , Periodontite Periapical/cirurgia , Cicatrização , Periodonto
15.
Materials (Basel) ; 16(10)2023 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-37241263

RESUMO

The nickel-titanium (NiTi) instruments' geometry plays an important role in their performance and behavior. The present assessment intends to validate and test the applicability of a 3D surface scanning method using a high-resolution laboratory-based optical scanner to create reliable virtual models of NiTi instruments. Sixteen instruments were scanned using a 12-megapixel optical 3D scanner, and methodological validation was performed by comparing quantitative and qualitative measurements of specific dimensions and identifying some geometric features of the 3D models with images obtained through scanning electron microscopy. Additionally, the reproducibility of the method was assessed by calculating 2D and 3D parameters of three different instruments twice. The quality of the 3D models created by two different optical scanners and a micro-CT device was compared. The 3D surface scanning method using the high-resolution laboratory-based optical scanner allowed for the creation of reliable and precise virtual models of different NiTi instruments with discrepancies varying from 0.0002 to 0.0182 mm. The reproducibility of measurements performed with this method was high, and the acquired virtual models were adequate for use in in silico experiments, as well as for commercial or educational purposes. The quality of the 3D model obtained using the high-resolution optical scanner was superior to that acquired by micro-CT technology. The ability to superimpose virtual models of scanned instruments and apply them in Finite Element Analysis and educational purposes was also demonstrated.

16.
J Endod ; 49(7): 819-835, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37225039

RESUMO

INTRODUCTION: This cross-sectional study assessed the influence of patient demographics on the worldwide prevalence of a lingual canal in mandibular incisors. METHODS: Twenty-six thousand four hundred mandibular incisors were evaluated using cone-beam computed tomography imaging by precalibrated observers from 44 countries. A standardized screening method was employed to collect data on the presence of a lingual canal, the anatomic configuration of the root canal, and number of roots. Patient demographic information (age, sex, and ethnicity) was also recorded. Multiple intra and interrater tests assessed the reliability of the observers and groups, and a meta-analysis was used to examine differences and heterogeneities (α = 5%). RESULTS: The prevalence of the lingual canal in mandibular central and lateral incisors varied from 2.3% (0.06%-4.0%; Nigeria) to 45.3% (39.7%-51.0%; Syria) and from 2.3% (0.06%-4.0%; Nigeria) to 55.0% (49.4%-60.6%; India), respectively. Ethnicity had a significant impact on the prevalence of the lingual canal, with African, Asian, and Hispanic groups having the lowest proportions (P < .05), while Caucasians, Indians, and Arabs showed the highest (P < .05) for both incisor groups. Additionally, males had a significantly higher odds ratio for both the central (1.334) and lateral (1.178) incisors, while older patients had a lower prevalence for both tooth groups (P < .05). The side and tooth group did not influence on the outcomes. CONCLUSIONS: The prevalence of lingual root canals in mandibular incisors varies significantly based on geographic location, ethnicity, age, and gender. The overall prevalence was 21.9% for mandibular central incisors and 26.0% for lateral incisors.


Assuntos
Cavidade Pulpar , Incisivo , Masculino , Humanos , Incisivo/diagnóstico por imagem , Estudos Transversais , Prevalência , Reprodutibilidade dos Testes , Raiz Dentária , Tomografia Computadorizada de Feixe Cônico/métodos , Mandíbula/diagnóstico por imagem , Estudos Multicêntricos como Assunto
17.
Clin Oral Investig ; 27(8): 4667-4675, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37247087

RESUMO

OBJECTIVE: This study aimed to evaluate changes on root canal morphology in patients with different ages using micro-CT technology. MATERIALS AND METHODS: Mandibular first molars (n = 150) were scanned at a pixel size of 13.68 µm, categorized into 3 groups according to patient's age and analyzed regarding configuration, orifices, apical foramina, root length, canal volume, and surface area. Morphological 2D and 3D parameters were evaluated in distal roots with Type I configuration (n = 109) as well as the morphology of isthmuses Types I and III in 68 mesial roots. One-way ANOVA post hoc Tukey and Kruskal-Wallis tests were used for statistical analyses (α = 5%). RESULTS: A great variation in the canal configuration was found. No difference was observed in roots' length (p > 0.05). Canal volume reduced with age (p < 0.05), while surface area increased (p < 0.05) in patients ≤ 30 years. There was no difference in canal/root length, area, and from foramen to the apex in distal roots with Type I configuration (p > 0.05), but 2D and 3D parameters significantly decreased with age (p < 0.05). Overall, the diameter of the isthmuses' roof reduced with age (p < 0.05). In patients ≥ 31 years with Type III isthmus the distance from the isthmus floor to the foramen of the mesiolingual canal also decreased (p < 0.05). CONCLUSION: Overall, the internal morphology of the mesial roots of mandibular first molars was more affected by aging than distal canals. The most relevant tested parameter that significantly reduced in both roots was the volume of the root canal systems. CLINICAL RELEVANCE: A detailed evaluation of fine anatomical aspects of the root canal system of mandibular first molars of patients with different ages showed that the internal morphology of mesial roots is more affected by aging than distal canals.


Assuntos
Cavidade Pulpar , Mandíbula , Humanos , Cavidade Pulpar/diagnóstico por imagem , Cavidade Pulpar/anatomia & histologia , Microtomografia por Raio-X , Mandíbula/diagnóstico por imagem , Mandíbula/anatomia & histologia , Tratamento do Canal Radicular , Dente Molar/diagnóstico por imagem , Dente Molar/anatomia & histologia , Raiz Dentária/diagnóstico por imagem , Raiz Dentária/anatomia & histologia
18.
Materials (Basel) ; 16(10)2023 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-37241402

RESUMO

Multiforce nickel-titanium (NiTi) orthodontic archwires release progressively increasing forces in a front-to-back direction along their length. The properties of NiTi orthodontic archwires depend on the correlation and characteristics of their microstructural phases (austenite, martensite and the intermediate R-phase). From a clinical and manufacturing point of view, the determination of the austenite finish (Af) temperature is of the greatest importance, as in the austenitic phase, the alloy is most stable and exhibits the final workable form. The main purpose of using multiforce orthodontic archwires is to decrease the intensity of the applied forces to the teeth with a small root surface area, such as the lower central incisors, and also provide forces high enough to move the molars. With the optimally dosed forces of multiforce orthodontic archwires in the frontal, premolar and molar segments, the feeling of pain can be reduced. This will contribute to the greater cooperation of the patient, which is of utmost importance to achieve optimal results. The aim of this research was to determine the Af temperature at each segment of as-received and retrieved Bio-Active® and TriTanium® archwires with dimensions of 0.016 × 0.022 inches, investigated by the differential scanning calorimetry (DSC) method. A classical Kruskal-Wallis one-way ANOVA test and multi-variance comparison based on the ANOVA test statistic using the Bonferroni corrected Mann-Whitney test for multiple comparisons were used. The incisor, premolar and molar segments have different Af temperatures, and they decrease from the anterior to posterior so that the posterior segment has the lowest Af. Bio-Active® and TriTanium® with dimensions of 0.016 × 0.022 inches can be used as first leveling archwires by additional cooling and are not recommended for use on patients with mouth breathing.

19.
Int Endod J ; 56(7): 896-908, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37029571

RESUMO

AIM: To compare two flat-side single-file rotary instruments with three single-file reciprocating systems through a multimethod assessment. METHODOLOGY: A total of 290 new NiTi single-file rotary (AF F One Blue 25/0.06 and Platinum V.EU 25/0.06) and reciprocating (One Files Blue R25, Reciproc Blue R25, Reciproc R25) instruments were selected, carefully examined for any major deformations, and evaluated regarding their macroscopic and microscopic design, nickel and titanium elements ratio, phase transformation temperatures, and mechanical performance (time/rotation to fracture, maximum torque, angle of rotation, microhardness, maximum bending, and buckling strengths). One-way anova post hoc Tukey, T-test, and nonparametric Mood's median tests were used for statistical comparisons (α = 5%). RESULTS: Tested instruments had identical blade counts and near-identical helical angles of approximately 24° (rotary instruments) and 151° (reciprocating instruments). The flat-side analysis revealed a few inconsistencies, such as discontinuity segments, different orientations, and gaps in the homogeneity of the bluish colour. Microscopically, flat-side instruments exhibited blade discontinuity and an incomplete S-shaped cross-section. The surface finish was smoother for One Files Blue and more irregular for both rotary instruments. There were distinct phase transformation temperatures amongst all instruments. All heat-treated instruments were in R-phase arrangement, and Reciproc was in R-phase plus austenite at test temperature (20°C). Compared with the reciprocating instruments, both flat-side instruments exhibited lower results in the cyclic fatigue tests using two different clockwise kinematics, maximum torque, angle of rotation, and maximum buckling strength (p < .05). The rotary systems also exhibited low flexibility (p < .05). AF F One Blue had the lowest microhardness, whilst Reciproc had the highest value. CONCLUSION: This multimethod investigation revealed that the flat-side rotary instruments underperformed the reciprocating instruments regarding cyclic fatigue (with two different clockwise kinematics), maximum torque, angle of rotation, maximum buckling strength, and flexibility. Manufacturing inconsistencies were also observed in some of the flat-side instruments, including discontinuity segments, different orientations, and in the homogeneity of their bluish colour given by the heat treatment.


Assuntos
Instrumentos Odontológicos , Temperatura Alta , Desenho de Equipamento , Preparo de Canal Radicular , Teste de Materiais , Titânio , Estresse Mecânico
20.
Int Endod J ; 56(6): 775-785, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36942476

RESUMO

AIM: This study aimed to compare three rotary instruments produced by the EDM process with the heat-treated ProTaper Gold system regarding design, metallurgy, mechanical properties and shaping ability. METHODOLOGY: HyFlex EDM (25/~), Neoniti (25/.06), EDMax (25/.06) and ProTaper Gold (25/.08v) instruments (n = 58 per group) were compared regarding design, metallurgy and mechanical performance. Unprepared canal areas were calculated for each system after preparation of mesiobuccal, mesiolingual and distal canals of mandibular molars (15 canals per group) using micro-CT technology. Statistical analyses were performed using One-way anova post-hoc Tukey and Kruskal-Wallis post-hoc Dunn's tests (α = 5%). RESULTS: All instruments had asymmetrical blades, no radial lands, no major defects and almost equiatomic nickel/titanium ratios, but different cross-section designs, tip geometries and surface appearances. Although instruments had distinct transformation temperature curves, they showed crystallographic martensitic arrangement at 21°C and mixed austenite plus R-phase at body temperature. Neoniti and HyFlex EDM showed similar results in all mechanical tests (p > .05), while EDMax and ProTaper Gold had similar time to fracture (p = .841), maximum bending load (p = .729), and cutting ability (p = .985). ProTaper Gold showed the highest torque to failure (p < .001) and HyFlex EDM had the lowest buckling resistance (p < .001). Mean percentages of unprepared canal areas ranged from 20.4% to 25.7% in the mesial canals, and from 20.8% to 26.2% in the distal canal, with no statistical differences among systems (p > .05). CONCLUSIONS: Instruments' geometry and phase transformation temperatures influenced the results of the mechanical tests, but not their shaping ability.


Assuntos
Preparo de Canal Radicular , Humanos , Ligas Dentárias/química , Instrumentos Odontológicos , Desenho de Equipamento , Teste de Materiais , Temperatura , Titânio/química , Torque
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...