1.
Sensors (Basel) ; 18(6)2018 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-29843446

RESUMO

In this article we respond to the comments made by Chavanne et al., who have questioned: (i) the name of the technique used; (ii) the ability of the system to determine both soil water content and salinity due to potential instrument biases and choice of sensor frequencies; and (iii) the procedure used to determine temperature effect on readings presented in the article "A Novel Low-Cost Instrumentation System for Measuring the Water Content and Apparent Electrical Conductivity of Soils" (Sensors 2015, 15, 25546⁻25563). We have carefully analyzed the arguments in the comment, and have concluded that they only partially affect the previous conclusions, as will be discussed in this reply. We show here that the findings and conclusions previously drawn are valid and supported by the many experiments previously conducted.

2.
Sensors (Basel) ; 15(10): 25546-63, 2015 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-26445049

RESUMO

The scarcity of drinking water affects various regions of the planet. Although climate change is responsible for the water availability, humanity plays an important role in preserving this precious natural resource. In case of negligence, the likely trend is to increase the demand and the depletion of water resources due to the increasing world population. This paper addresses the development, design and construction of a low cost system for measuring soil volumetric water content (θ), electrical conductivity (σ) and temperature (T), in order to optimize the use of water, energy and fertilizer in food production. Different from the existing measurement instruments commonly deployed in these applications, the proposed system uses an auto-balancing bridge circuit as measurement method. The proposed models to estimate θ and σ and correct them in function of T are compared to the ones reported in literature. The final prototype corresponds to a simple circuit connected to a pair of electrode probes, and presents high accuracy, high signal to noise ratio, fast response, and immunity to stray capacitance. The instrument calibration is based on salt solutions with known dielectric constant and electrical conductivity as reference. Experiments measuring clay and sandy soils demonstrate the satisfactory performance of the instrument.

3.
PLoS One ; 9(5): e95874, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24851994

RESUMO

Based on the necessity for enclosure protection of temperature and relative humidity sensors installed in a hostile environment, a wind tunnel was used to quantify the time that the sensors take to reach equilibrium in the environmental conditions to which they are exposed. Two treatments were used: (1) sensors with polyvinyl chloride (PVC) enclosure protection, and (2) sensors with no enclosure protection. The primary objective of this study was to develop and validate a 3-D computational fluid dynamics (CFD) model for analyzing the temperature and relative humidity distribution in a wind tunnel using sensors with PVC enclosure protection and sensors with no enclosure protection. A CFD simulation model was developed to describe the temperature distribution and the physics of mass transfer related to the airflow relative humidity. The first results demonstrate the applicability of the simulation. For verification, a sensor device was successfully assembled and tested in an environment that was optimized to ensure fast change conditions. The quantification setup presented in this paper is thus considered to be adequate for testing different materials and morphologies for enclosure protection. The results show that the boundary layer flow regime has a significant impact on the heat flux distribution. The results indicate that the CFD technique is a powerful tool which provides a detailed description of the flow and temperature fields as well as the time that the relative humidity takes to reach equilibrium with the environment in which the sensors are inserted.


Assuntos
Umidade , Hidrodinâmica , Termômetros , Agricultura/instrumentação , Simulação por Computador , Desenho de Equipamento , Manipulação de Alimentos/instrumentação , Modelos Químicos , Cloreto de Polivinila/química , Temperatura , Vento
4.
Biochem Biophys Res Commun ; 418(2): 284-9, 2012 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-22266312

RESUMO

Liver steatosis was once believed to be a benign condition, with rare progression to chronic liver disease. Thus, in both clinical and experimental practice, it is fundamental to have a reliable and objective method for its precise quantification. An image analysis algorithm was developed and validated for automatically and rapidly quantifying hepatic fat microvesicles. The image processing algorithms automatically segmented interstitial steatosis areas and analyzed the threshold region. Automatic quantifications did not significantly differ from manual evaluations of means of the same areas. Comparison of our image analysis quantifications with staging of histologic evaluations of liver steatosis presented significant correlations that are based on the distribution patterns and on the area quantity of steatosis, respectively. The use of algorithms for analysis and image processing is a sensitive, precise, objective and reproducible method of quantifying hepatic fat microvesicles, which complements semi-quantitative histologic evaluation systems.


Assuntos
Gorduras na Dieta/metabolismo , Fígado Gorduroso/patologia , Técnicas Histológicas , Interpretação de Imagem Assistida por Computador/métodos , Fígado/irrigação sanguínea , Algoritmos , Animais , Computadores , Gorduras na Dieta/administração & dosagem , Gorduras na Dieta/análise , Microvasos/metabolismo , Microvasos/patologia , Ratos , Ratos Wistar