Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Plast Reconstr Surg Glob Open ; 12(1): e5504, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38196843

RESUMO

Background: Augmentation mastopexy remains a challenging surgery and has been frequently associated with suboptimal outcomes and remarkable reoperation rates, and one of the greatest challenges in mastopexy surgery is areolar lift, especially when implants are simultaneously used. Through the authors' experience, this study is aimed to show a modification of the vertical approach with greater safety of the areolar pedicle. Methods: The study included all patients who underwent augmentation mastopexy surgery performed by the authors between 2019 and 2022, whether primary or nonprimary, and performed a retrospective chart review of all patients who underwent this procedure. Results: The length of the areolar lift ranged from 0 cm to 14 cm. Among the 17.4% of nonprimary mastopexies, the longest areolar lift was 11 cm. No cases of nipple-areola complex ischemia/necrosis were observed. With this technique, there were 6.2% complications (n = 31), none of which were considered serious. Conclusions: This surgical sequence is a safe option for areolar lift in augmentation mastopexy. The vertical approach also has the advantage of producing considerably shorter horizontal scars. It is also reproducible, keeping the implant stable, which results in consistent long-term results.

2.
BMC Med Educ ; 23(1): 633, 2023 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-37667360

RESUMO

BACKGROUND: Medical simulation allows for the achievement of many educational goals and the continued education of some practical skills. The COVID-19 pandemic's restrictions have led to a major increase in dental education simulations. The aim of this study was to analyse the perspectives of academic teachers towards dental simulation, their concerns and evaluation of this teaching method, as well as their opinion on the use of medical simulation during the COVID-19 pandemic. METHOD: A focus study was conducted in a group of 5 academic teachers, comprising 10% of academic teachers of a Dental Faculty using simulation techniques. Prior to and during the COVID-19 pandemic, the interviewed teachers had expertise with medical simulation in dentistry education methods. A facilitator used pre-planned, open-ended questions about the use of simulation in dentistry also with regard to the COVID-19 pandemic period. The group discussion has been managed, monitored, and recorded. The data analysis model was based on Braun and Clarke's six phases of thematic analysis. Five thematic domains/fields were evaluated: (1) Simulation as a didactic method; (2) Simulation during COVID-19 pandemic; (3) General observations and expectations with regard to simulation; (4) Teachers in simulation; (5) Concerns in relation to simulation. Two researchers analysed the data. RESULTS: Based on interviewed teachers' perspective the simulation allows students to learn basic and complex skills providing the repeatability of the procedures performed. During Covid-19 the simulation methods undoubtedly filled the gap in the training of future dentists. However, interviewed teachers pointed out the high cost of the methods dictated by the need to prepare the simulation environment at a high level, in order to reflect the real clinical situation. CONCLUSIONS: The use of simulation methods requires adequate preparation of academic teachers, continuous education and updating of knowledge in the field of medical simulation. The COVID-19 pandemic significantly influenced the growth of dental education simulation techniques as well as staff knowledge of the usage of medical simulation.


Assuntos
COVID-19 , Pessoal de Educação , Humanos , COVID-19/epidemiologia , Pandemias , Pesquisa Qualitativa , Odontologia
3.
Dentomaxillofac Radiol ; 52(7): 20230147, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37493606

RESUMO

OBJECTIVE: To compare cylindrical and convex triangular field-of-views (FOVs) concerning the magnitude of artefacts from high-density materials in cone-beam CT (CBCT). METHODS AND MATERIALS: Cylinders of amalgam, chromium-cobalt, titanium, and zirconia were individually placed in the anterior and posterior regions of a polymethylmethacrylate phantom and scanned using cylindrical and convex triangular FOVs of the Veraview X800 CBCT device. Using the Image J software, 15 square regions of interest (ROIs) were placed in the axial reconstruction around the middle level of the cylinder and at distances of 0.5, 1.0, and 1.5 cm from the centre of the cylinder. Mean grey value and standard deviation of each ROI were averaged for each distance and subtracted from the values of a control ROI to calculate the magnitude of the artefacts by the grey value mean difference (GVMD) and grey value standard deviation (GVSD). Multiway analysis of variance with Tukey post-hoc test with a significance level of 5% evaluated the effect of the shape of the FOV, position inside the FOV, high-density material, and the distance of the artefact from the material. RESULTS: The convex triangular FOV increased the GVSD for all materials in the anterior and posterior regions at 0.5 cm compared to the cylindrical FOV (p < 0.0001). The convex triangular FOV showed greater GVMD for chromium-cobalt and zirconium in the anterior region and all materials in the posterior region at all distances (p < 0.0001). CONCLUSION: The FOV shape influences the magnitude of artefacts from high-density materials. The convex triangular FOV showed greater artefact magnitude with variability among the high-density materials, region in the FOV, and distance from the material.


Assuntos
Artefatos , Tomografia Computadorizada de Feixe Cônico , Humanos , Cobalto , Cromo , Imagens de Fantasmas
4.
Imaging Sci Dent ; 53(1): 61-67, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37006786

RESUMO

Purpose: The aim of this study was to objectively detect simulated tooth ankylosis using a novel method involving cone-beam computed tomography (CBCT). Materials and Methods: Tooth ankylosis was simulated in single-rooted human permanent teeth, and CBCT scans were acquired at different current levels (5, 6.3, and 8 mA) and voxel sizes (0.08, 0.125, and 0.2). In axial reconstructions, a line of interest was perpendicularly placed over the periodontal ligament space of 21 ankylosed and 21 non-ankylosed regions, and the CBCT grey values of all voxels along the line of interest were plotted against their corresponding X-coordinates through a line graph to generate a profile. The image contrast was increased by 30% and 60% and the profile assessment was repeated. The internal area of the resulting parabolas was obtained from all images and compared between ankylosed and non-ankylosed regions under different contrast enhancement conditions, voxel sizes, and mA levels using multi-way analysis of variance with the Tukey post hoc test (α=0.05). Results: The internal area of the parabolas of all non-ankylosed regions was significantly higher than that of the ankylosed regions (P<0.05). Contrast enhancement led to a significantly greater internal area of the parabolas of non-ankylosed regions (P<0.05). Overall, voxel size and mA did not significantly influence the internal area of the parabolas (P>0.05). Conclusion: The proposed novel method revealed a relevant degree of applicability in the detection of simulated tooth ankylosis; increased image contrast led to greater detectability.

5.
Dentomaxillofac Radiol ; 52(4): 20220370, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36988093

RESUMO

OBJECTIVE: To assess the subjective image quality of original and manually enhanced radiographs acquired at different X-ray exposure times and using different digital systems. METHODS: A total of 500 radiographs obtained under 10 exposure times, 5 digital systems, and 2 enhancement conditions were assessed by 5 observers, who were asked to categorize each radiograph into acceptable or unacceptable. A radiograph was considered to be acceptable when at least four out of five observers found it acceptable. Descriptive analysis was used to summarize the outcomes and compare the subjective image quality of original and manually enhanced digital radiographs among different X-ray exposure times and digital systems. RESULTS: Express had six exposure times producing acceptable original images within a range from 0.063 to 0.4 s, followed by Digora Toto, which had five within a range from 0.063 to 0.32 s, Digora Optime, which had four within a range from 0.063 to 0.2 s,and SnapShot and VistaScan, which had 2 (0.2 and 0.32 s) and 1 (0.63 s), respectively. Image enhancement turned unacceptable images into acceptable ones in four digital systems: SnapShot at three exposure times, Digora Toto at two exposure times, Express at one exposure time, and VistaScan at four exposure times. CONCLUSION: Image enhancement based on brightness and/or contrast adjustments may be necessary to reveal the useful dynamic range of some digital radiographic systems and PSP-based systems may not necessarily have a wider range than sensor-based systems.


Assuntos
Intensificação de Imagem Radiográfica , Radiografia Dentária Digital , Humanos , Radiografia Dentária Digital/métodos , Intensificação de Imagem Radiográfica/métodos
6.
Artigo em Inglês | MEDLINE | ID: mdl-36241601

RESUMO

OBJECTIVE: To evaluate the diagnostic efficacy of cone beam computed tomography (CBCT) examinations acquired with varying dose protocols in the diagnosis of simulated tooth ankylosis (TA). STUDY DESIGN: Tooth ankylosis was simulated in 15 of 30 teeth, and CBCT examinations were acquired at 3 mA levels (8, 6.3, and 5) and 3 voxel sizes (0.08, 0.125, and 0.2 mm). Four radiologists independently assessed the presence of TA using a 5-point scale. Sensitivity, specificity, and area under the curve (AUC) obtained through receiver operating characteristic analysis were compared among mA levels and voxel sizes using two-way analysis of variance (α = 0.05). Intra- and interexaminer reliability levels were assessed with the weighted kappa examination. RESULTS: Sensitivity was low (0.32-0.49), and specificity was reasonably high (0.71-0.83). Mean values of AUC were low, ranging between 0.54 and 0.67, which reveals poor overall discrimination between health and disease. The detection of TA was not significantly influenced by mA level or voxel size (P > .05). Intra- and interexaminer agreements ranged from slight to moderate (0.160-0.535) and from fair to substantial (0.236-0.697), respectively. CONCLUSIONS: Despite the limited efficacy of CBCT for TA detection, when indicated as a complementary examination, mA reduction should be considered for dose optimization purposes.


Assuntos
Anquilose Dental , Fraturas dos Dentes , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Redução da Medicação , Reprodutibilidade dos Testes , Raiz Dentária
7.
Imaging Sci Dent ; 52(3): 267-273, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36238703

RESUMO

Purpose: The aim of this study was to assess the influence of kilovoltage-peak (kVp) and the metal artifact reduction (MAR) tool on the detection of buccal and lingual peri-implant dehiscence in the presence of titanium-zirconia (Ti-Zr) and zirconia (Zr) implants in cone-beam computed tomography (CBCT) images. Materials and Methods: Twenty implant sites were created in the posterior region of human mandibles, including control sites (without dehiscence) and experimental sites (with dehiscence). Individually, a Ti-Zr or Zr implant was placed in each implant site. CBCT scans were performed using a Picasso Trio device, with variation in the kVp setting (70 or 90 kVp) and whether the MAR tool was used. Three oral radiologists scored the detection of dehiscence using a 5-point scale. The area under the receiver operating characteristic (ROC) curve, sensitivity, and specificity were calculated and compared by multi-way analysis of variance (α=0.05). Results: The kVp, cortical plate involved (buccal or lingual cortices), and MAR did not influence any diagnostic values (P>0.05). The material of the implant did not influence the ROC curve values (P>0.05). In contrast, the sensitivity and specificity were statistically significantly influenced by the implant material (P<0.05) with Zr implants showing higher sensitivity values and lower specificity values than Ti-Zr implants. Conclusion: The detection of peri-implant dehiscence was not influenced by kVp, use of the MAR tool, or the cortical plate. Greater sensitivity and lower specificity were shown for the detection of peri-implant dehiscence in the presence of a Zr implant.

8.
Dentomaxillofac Radiol ; 51(4): 20210404, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34860568

RESUMO

OBJECTIVES: To assess the dynamic range and enhancement ability of radiographs acquired with contemporary digital systems. METHODS: Five repeated periapical radiographs of human mandibles with an aluminium step-wedge were acquired using two sensor-based and three photostimulable phosphor plate-based systems and an X-ray unit at ten exposure times 0.020, 0.032, 0.063, 0.080, 0.100, 0.200, 0.320, 0.400, 0.500, and 0.630 s. All images had their brightness and contrast enhanced by two experienced oral and maxillofacial radiologists in consensus and were exported as both the original and enhanced file formats. Mean grey values were obtained from the aluminium steps and tabulated with their corresponding thicknesses for each exposure time, digital radiographic system, and file format. Images with saturated steps were excluded and the mean grey values from the remaining images were averaged to assess image brightness and the angular coefficient of the linear trendlines was generated from the relationship between mean grey values and their corresponding aluminium thicknesses to assess image contrast. Brightness and contrast values were compared using two-way ANOVA with post-hoc Tukey (α = 0.05). RESULTS: Photostimulable phosphor plate-based digital radiographic systems had a broader dynamic range. Longer exposure times produced original images with lower brightness and variable contrast (p < 0.05). Subjective enhancement significantly increased or reduced brightness and/or contrast in some systems (p < 0.05). CONCLUSIONS: Contemporary digital radiographic systems present different dynamic ranges and exposure-related brightness and contrast. Image enhancement may be a valuable tool at slightly suboptimal exposure times.


Assuntos
Alumínio , Radiografia Dentária Digital , Humanos , Mandíbula , Intensificação de Imagem Radiográfica/métodos , Radiografia Dentária Digital/métodos
9.
Dentomaxillofac Radiol ; 51(4): 20210082, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34757830

RESUMO

OBJECTIVE: To map the shape, location, and thickness of the focal trough of a panoramic radiography device with a multilayer imaging program. METHODS: An acrylic plate (148 × 148 × 3 mm) containing 1156 holes distributed in a matrix of 34 × 34 rows was placed in the OP300 Maxio at the levels of the maxilla and mandible. 20 metal spheres (3.5 mm in diameter) were placed on the holes of the plate under 15 different arrangements and panoramic images were acquired for each arrangement at 66 kV, 8 mA, and an exposure time of 16 s. The resulting panoramic radiographs from the five image layers were exported, the horizontal and vertical dimensions of the metal spheres were measured in all images using the Image J software, and the magnification and distortion rates of the spheres were calculated. All metal spheres presenting a magnification rate lower than 30% in both vertical and horizontal dimensions and a distortion rate lower than 10% were considered to map the focal troughs of each of the five image layers. RESULTS: All panoramic image layers had a curved shape ranging from 39° to 51° for both dental arches and varied in position and thickness. The anterior region of maxilla was anteriorly displaced when compared to the anterior region of the mandible for all layers. Image layers are thicker at the level of the mandible than those at the level of the maxilla; also, inner layers were thinner and outer layers were thicker. CONCLUSION: All image layers in the studied panoramic radiography device had a curved shape and varied in position and thickness. The anterior region of maxilla was anteriorly displaced when compared to that of the mandible for all layers.


Assuntos
Mandíbula , Maxila , Humanos , Mandíbula/diagnóstico por imagem , Maxila/diagnóstico por imagem , Radiografia Panorâmica/métodos
10.
Zootaxa ; 5209(2): 211-237, 2022 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-37045396

RESUMO

The knowledge of bioacoustics of the Neotropical crickets (Orthoptera, Gryllidea) is incipient, despite the great species diversity in the region. There are few cricket song-files deposited in the major World Sound Libraries, compared to other groups such as birds and amphibians. In order to contribute to the knowledge of the bioacoustics of Brazilian crickets, we organize, analyze and make available at Fonoteca Neotropical Jacques Vielliard (FNJV) and Orthoptera Species File (OSF) our bank of cricket songs. We deposited 876 cricket's song files in the FNJV, belonging to 31 species and 47 sonotypes. The songs were field/lab recorded, and all individuals were collected to improve species/sonotypes taxonomic determination accuracy. We present photos (in vivo) of most recorded crickets, as well as calling song spectrograms to facilitate the species/sonotype recognition. Samples of the songs can be found online on the FNJV website, using the codes available in this work, as well as on the OSF, linked to the species name. As a result, we advance the knowledge of the songs of crickets and the current perspective of the Brazilian cricket bioacoustics. We encourage researchers to share with the public their collections of their cricket file songs both in the FNJV and the OSF.


Assuntos
Gryllidae , Ortópteros , Animais , Brasil , Vocalização Animal
11.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1385847

RESUMO

ABSTRACT: This study evaluated patients´ anxiety levels related to dental radiographic examinations in addition to dentists' perception and management. Salivary alpha-amylase (sAA) activity of 47 patients was measured before and after exposure to radiographic examinations to assess their anxiety level and compared using Wilcoxon test. Mann-Whitney test assessed the sAA activity related to sex, type of examination, and previous experience with radiographic examinations. 50 dentists were interviewed using a semi-structured script containing open-ended questions perception on their patients' anxiety. Before the radiographic examination, sAA activity was significantly higher for women (p ≤0.05). SAA activity significantly increased after the examination for men, patients of both sexes with no previous experience and for those who underwent CBCT (p≤0.05). Anxiety was reported to be observed in adult patients' speech and pediatric patients' behavior. Dental radiographic examinations may be a source of anxiety for women before the examination. After the examination, men, patients with no previous experience, and those subjected to CBCT present higher anxiety levels. Dentists perceive anxiety in adult and pediatric patients differently.


RESUMEN: Este estudio evaluó los niveles de ansiedad en los pacientes relacionados con exámenes radiográficos dentales, además de la percepción y el manejo de los dentistas. Se midió la actividad de la alfa-amilasa salival (sAA) de 47 pacientes antes y después de la exposición a exámenes radiográficos para evaluar su nivel de ansiedad y se comparó mediante la prueba de Wilcoxon. La prueba de Mann-Whitney evaluó la actividad de la sAA relacionada con el sexo, el tipo de examen y la experiencia previa con exámenes radiográficos. Se entrevistó a 50 dentistas utilizando un guión semiestructurado de preguntas abiertas sobre la percepción de la ansiedad de sus pacientes. Antes del examen radiográfico, la actividad de la sAA era significativamente mayor para las mujeres (p≤0.05). La actividad de SAA aumentó significativamente después del examen para los hombres, pacientes de ambos sexos sin experiencia previa y para los que se sometieron a CBCT (p≤0.05). Se informó que se observa ansiedad en el habla de los pacientes adultos y en el comportamiento de los pacientes pediátricos. Los exámenes radiográficos dentales pueden ser una fuente de ansiedad para las mujeres antes del examen. Tras la exploración, los hombres, los pacientes sin experiencia previa y los sometidos a CBCT presentan niveles de ansiedad más elevados. Los dentistas perciben la ansiedad en los pacientes adultos y pacientes pediátricos de manera diferente.

12.
Int Orthod ; 19(3): 462-470, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34312102

RESUMO

INTRODUCTION: To evaluate the influence of sagittal and vertical skeletal patterns (skeletal classes and facial profiles), and sex on the distance between upper central incisors roots and incisive canal. MATERIAL AND METHODS: Cone-beam computed tomography exams of 172 patients were classified into skeletal classes I, II, and III and according to the facial profile into mesofacial, brachyfacial, and dolichofacial. In sagittal reconstructions, linear measurements were done between central incisors roots and incisive canal at three levels: incisive foramen opening, intermediate region, and the region close to the apex of upper central incisors. In axial reconstructions, measurements of incisive canal width and distance between the roots were obtained. Analysis of Variance (three-way ANOVA) was used to evaluate measurement differences in relation to skeletal classes, facial profiles, and sex. RESULTS: The distance between upper central incisors roots and incisive canal anterior region was little influenced by sagittal and vertical skeletal patterns and sex. Men had significantly greater incisive canal (mean=2.85mm; SD=1.18) width compared to women (mean=2.40mm; SD=1.04), regardless of skeletal class and facial profile (P<0.05). In general, inter-root distance between medial points of central incisors roots and incisive canal opening was greater in the region close to upper central incisors apex (mean=3.84mm; SD=1.44) than in incisive foramen opening (2.44mm; SD=1.04), (P<0.05). CONCLUSIONS: The distance between upper central incisors roots and incisive canal is little influenced by sagittal and vertical skeletal patterns and sex.


Assuntos
Incisivo , Tomografia Computadorizada de Feixe Cônico Espiral , Tomografia Computadorizada de Feixe Cônico , Feminino , Humanos , Incisivo/diagnóstico por imagem , Masculino , Maxila/diagnóstico por imagem , Estudos Retrospectivos
13.
Vaccine X ; 8: 100103, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34179765

RESUMO

Many countries have reported antigenic divergence among circulating Bordetella pertussis strains, mainly in those countries which introduced the acellular pertussis (aP) vaccine. This phenomenon can be seen, for example, with the recent rise of pertactin (Prn)-deficient B. pertussis strains, one of the antigens included in aP vaccine formulas. The whole cell pertussis (wP) vaccine has been used in Brazil since 1977 for the primary pertussis, diphtheria and tetanus immunization series. In 2014, the aP vaccine was recommended for women during pregnancy to protect infants in the first months of life. Our objective was to determine the prevalence of Prn-deficiency in 511 isolates of B. pertussis collected in Brazil during 2010-2016. All isolates were characterized, through PFGE and serotyping, and screened for the loss of Prn by ELISA. Prn-deficiency was confirmed by immunoblotting, and identification of the possible genetic markers was performed with PCR and Sanger sequencing. Results indicate that 110 PFGE profiles are currently circulating, with five profiles representing the majority, and the predominant serotype 3, has been gradually replaced by serotype 2 and serotype 2,3. ELISA screening and immunoblotting identified three Prn-deficient isolates. Genotypic characterization by PCR and sequencing indicated that one isolate had a promoter mutation in prn, while the other two did not have an obvious genetic explanation for their deficiency. While the lack of Prn was identified in a few isolates, this study did not detect a relevant occurrence of Prn-deficiency, until 2016, confirming previous observations that Prn-deficiency is likely aP vaccine-driven.

14.
Zootaxa ; 4938(1): zootaxa.4938.1.5, 2021 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-33756986

RESUMO

Phalangopsids are a diverse group of crickets found in all tropical and subtropical regions, and includes 1044 valid species. Up to now, only 22 species were studied cytologically, with the chromosome number ranging from 2n = 11 to 2n = 21. In this paper we studied the chromosomes of 12 phalangopsid species from different Brazilian biomes (eight of them reported for the first time), and we traced some trends on chromosomal derivation in this group, based on chromosome morphology and fundamental number. We found that in the phalangopsid species the karyotype concentrates a large amount of metacentric chromosomes, the result of successive centric fusions over evolutionary time. Moreover, pericentric inversions and translocations have been also important in the chromosomal derivation of these crickets.


Assuntos
Gryllidae , Animais , Inversão Cromossômica , Gryllidae/genética , Cariótipo , Cariotipagem
15.
Clin Oral Investig ; 25(2): 637-643, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32845471

RESUMO

OBJECTIVES: To compare the overall diagnostic performance of digital panoramic radiographs obtained with low-dose protocols and to estimate the absorbed dose in the head and neck. MATERIALS AND METHODS: Forty-eight panoramic radiographs were obtained from eight imaging phantoms using six exposure protocols of progressively lower tube voltages (kVp) and currents (mA), as follows: (1) 70 kVp and 12.5 mA, (2) 66 kVp and 10 mA, (3) 66 kVp and 8 mA, (4) 66 kVp and 5 mA, (5) 66 kVp and 4 mA and (6) 66 kVp and 3.2 mA. Five oral radiologists independently evaluated the images and reported all detectable radiographic findings. Intra-examiner reproducibility was assessed by re-evaluation of 25% of the images. The data were analysed using the McNemar and weighted Kappa tests. Absorbed doses of the six protocols were obtained from thermoluminescent dosimeters placed inside a Rando phantom and compared using one-way ANOVA with post hoc Tukey (α = 0.05). RESULTS: The overall diagnostic performance of panoramic radiographs obtained with low-dose protocols did not differ from that of panoramic radiographs obtained with the highest dose (p > 0.05). Moreover, substantial agreement was observed between all protocols. Protocol 1 resulted in the highest absorbed dose and protocols 4, 5 and 6 in the lowest absorbed doses, with the difference being significant (p ≤ 0.05). CONCLUSION: Although digital panoramic radiography is considered a relatively low-dose examination, the radiation dose can be further reduced without negatively affecting its overall diagnostic performance. CLINICAL RELEVANCE: Considering the risks associated with X-rays, digital panoramic radiographs can be obtained at even lower exposure levels.


Assuntos
Radiografia Dentária Digital , Dosimetria Termoluminescente , Imagens de Fantasmas , Doses de Radiação , Radiografia Panorâmica , Reprodutibilidade dos Testes
16.
Rev. cir. traumatol. buco-maxilo-fac ; 20(3): 29-33, jul.-set. 2020. ilus
Artigo em Português | BBO - Odontologia, LILACS | ID: biblio-1253237

RESUMO

Introdução: O objetivo do presente estudo é apresentar um caso clínico de osteomielite como complicação de fratura mandibular não tratada. Relato do caso: Paciente de do gênero masculino, 32 anos, compareceu ao serviço de Cirurgia e Traumatologia Bucomaxilofacial relatando ter sido vítima de queda da própria altura após ingestão de bebida alcoólica há mais de dois meses, com queixa de secreção em face. No exame físico observou-se presença de fistula extra oral na região mentual à esquerda com débito ativo de secreção sero purulenta; dor local; febre; limitação de abertura oral; parestesia da região mentual à esquerda, edema significativo e pseudartrose. O exame tomográfico confirmou a presença de fratura cominutiva de mandíbula com sequestro ósseo na região basilar. Optou-se por procedimento cirúrgico sob anestesia geral, com remoção de sequestro ósseo e fixação interna rígida. Considerações finais: Houve boa evolução, com regressão dos sintomas apresentados... (AU)


Introduction: The aim of this study is to present a clinical case of osteomyelitis as a complication of untreated mandibular fracture. Case report: Male patient, 32 years old, attended the service of Buccomaxillofacial Surgery, reporting that he had fallen from his own height after drinking alcohol for more than two months, complaining of secretion in the face. In the physical examination there was presence of extra oral fistula in the left mental region with active discharge of purulent serus secretion; local pain; fever; oral opening limitation; paresthesia of the left mental region, significant swelling and pseudarthrosis. The tomographic examination confirmed the presence of a comminuted mandible fracture with bone sequestration in the basilar region. We opted for surgical procedure under general anesthesia, with removal of bone sequestration and rigid internal fixation. Final considerations: There was a good evolution, with regression of the presented symptoms... (AU)


Assuntos
Humanos , Masculino , Adulto , Osteomielite , Cirurgia Bucal , Fraturas Mandibulares , Procedimentos Cirúrgicos Operatórios , Osso e Ossos , Fraturas Ósseas
17.
Dentomaxillofac Radiol ; 49(8): 20200039, 2020 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-32543940

RESUMO

OBJECTIVE: To assess the influence of windowing and metal artefact reduction (MAR) algorithms on the volumetric dimensions of high-density materials using two CBCT systems. METHODS: Four cylinders of amalgam, cobalt-chromium, gutta-percha, titanium and zirconium, were manufactured and their physical volumes (PV) were measured. A polymethyl methacrylate phantom containing the cylinders was submitted to CBCT acquisitions with Picasso Trio and OP300 units with their MAR enabled and disabled. The tomographic volume (TV) of all the cylinders was obtained by semi-automatic segmentation using two windowing adjustments: W1-large window width and upper window level; W2-narrow window width and low window level. Volumetric distortion was expressed as the difference between TV and PV. Statistics comprised intraclass correlation coefficient (ICC) and analysis of variance (ANOVA) for repeated measures with Tukey post hoc test (α = 5%). RESULTS: The ICC values ​​indicated excellent reproducibility of TV. Gutta-percha and titanium resulted in the smallest volumetric distortion. Using W1 provided less volumetric distortion for almost all experimental conditions (p < 0.05). Activating MAR algorithm of Picasso Trio underestimated gutta-percha and titanium TV (p < 0.05) and was inefficient in significantly reducing the volumetric distortion of the other materials (p > 0.05). Disabling MAR algorithm of OP300 resulted in smaller volumetric distortion for almost all experimental conditions (p < 0.05). CONCLUSIONS: The TV of gutta-percha and titanium were closer to the PV. In general, the MAR algorithms of both systems were inefficient in significantly reducing the volumetric distortion of high-density materials. We encourage the use of large window width and upper window level to evaluate high-density materials.


Assuntos
Artefatos , Tomografia Computadorizada de Feixe Cônico , Algoritmos , Metais , Reprodutibilidade dos Testes
18.
Eur J Dent Educ ; 24(3): 513-517, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32304263

RESUMO

BACKGROUND: Photographs and radiographs are indispensable resources for dental education, research and dissemination of clinical cases in scientific journals. The objective of this study was to evaluate the behaviour of dentists on the use of patients' images. MATERIAL AND METHODS: Fifty-two dentists were interviewed using a semi-structured script containing open-ended questions on the use of patients' images. The answers were analysed using a qualitative-quantitative method of the discourse of the collective subject, and the distribution of the absolute and relative frequency of the answers was presented according to the central ideas obtained from the discourses. RESULTS: The following central ideas on the use of patients' images were identified: (a) purpose: didactic and/or academic; (b) informed consent: verbal or absent when the patient cannot be identified; (c) discussion groups on social media contribute to learning; (d) most dentists would not appreciate and sue the author if they had their own photographs/imaging examinations posted on social media; 5. most dentists received some information on ethical regulations during dental school and state that images can be used with patient authorisation, without identification and for didactic/academic purposes. CONCLUSION: Dentists consider the use of patients' images for didactic and scientific purposes beneficial, request informed consent to share mainly images that reveal the identity and would not appreciate if their personal images were shared without consent.


Assuntos
Odontólogos , Mídias Sociais , Atitude do Pessoal de Saúde , Comunicação , Educação em Odontologia , Humanos , Inquéritos e Questionários
19.
Dentomaxillofac Radiol ; 49(5): 20190385, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32155087

RESUMO

OBJECTIVES: To create a new phantom design to evaluate the real impact of artefacts caused by titanium on bone structures in cone beam CT images considering different positions and quantity of metals in the dental arch, with and without metal artefact reduction (MAR). METHODS: A three cylindrical polymethyl methacrylate (PMMA) plate phantom was designed containing eight perforations arranged to simulate the lower dental arch in the intermediate plate. Three titanium cylinders were positioned in different locations and quantities to test different clinical conditions and to quantify the impact of the metal artefact around five bone cylinders. Scans were carried out in seven different protocols (Control, A-F) in two cone beam CT devices (OP300 Maxio and Picasso Trio). Eight regions of interest around each cortical and trabecular bone were used to measure the grey value standard deviation corresponding the artefact expression in the Image J software. Both the artefact expression and the MAR effect were assessed using the Wilcoxon, Friedman (Dunn) and Kruskal-Wallis tests (significance level of 5%). RESULTS: For both devices, MAR was statistically efficient only for the protocols E, and F. Protocol F (three metals on the adjacent area of the analysis region) showed higher artefact expression when compared to the others. CONCLUSION: In conclusion, the new phantom design allowed the quantification of the metal artefact expression caused by titanium. The metal artefact expression is higher when more metal objects are positioned in the adjacent bone structures. MAR may not be effective to reduce artefact expression on the adjacencies of those objects for the devices studied.


Assuntos
Artefatos , Tomografia Computadorizada de Feixe Cônico Espiral , Tomografia Computadorizada de Feixe Cônico , Arco Dental , Metais , Imagens de Fantasmas
20.
J Oral Maxillofac Surg ; 77(4): 721-729, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30597135

RESUMO

PURPOSE: To evaluate the influence of facial profile and age on the morphology of the nasopalatine canal. MATERIALS AND METHODS: One hundred thirty-two cone-beam computed tomograms were classified according to facial profile-mesofacial, brachyfacial, and dolichofacial-and divided into the following age groups: 21 to 30, 31 to 40, 41 to 50, and 51 to 60 years. Measurements were obtained for openings of the incisive and nasopalatine foramina, alveolar bone thickness, and the full length, most constricted region, and volume of the nasopalatine canal. Intra- and inter-examiner agreements were calculated using the intraclass correlation coefficient. After exploratory and descriptive analysis, data were subjected to 2-way analysis of variance and Tukey test for comparisons between facial profiles and age groups. The significance level was 5% (α = 0.05). RESULTS: Intra- and inter-examiner reproducibilities were excellent for all measurements. Patients older than 50 years presented a significantly larger nasopalatine canal than patients 21 to 30 years old for all facial profiles (P ≤ .05). Linear measurements obtained from the nasopalatine canal showed no significant difference between facial profiles and age groups (P > .05). CONCLUSIONS: The nasopalatine canal was not influenced by facial profile but did exhibit an increased volume with aging, particularly after 50 years of age.


Assuntos
Fatores Etários , Palato Duro/anatomia & histologia , Adulto , Tomografia Computadorizada de Feixe Cônico , Face , Humanos , Pessoa de Meia-Idade , Palato Duro/diagnóstico por imagem , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...