Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 125
Filtrar
1.
J Ultrasound ; 2024 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-38879835

RESUMO

PURPOSE: In correlation with magnetic resonance imaging (MRI), this study attempts to assess the effectiveness of the diagnostic of ultrasonography (US) features and shear wave elastography (SWE) in determining the different causes of heel pain. MATERIALS AND METHODS: 55 heels with a mean age of 38.33 ± 10.8 were included in the study (10 control cases and 41 cases, 4 of which had bilateral heel pain). There were 23 female cases (56.1%) and 18 male cases (43.95%). Examinations using shear wave elastography (SWE) and ultrasound (US) were done in different positions. MRI and the obtained data were correlated. RESULTS: When used to diagnose different heel pain causes, ultrasound demonstrated great sensitivity and specificity. SWE demonstrated a good correlation with MRI findings and enhanced the ultrasound's diagnostic precision in identifying plantar fasciitis early on (increased accuracy from 88.9 to 93.33% with 100% sensitivity and 83.3% specificity) and Achilles tendinopathy (increased accuracy from 88.9 to 97.8 with 94.7% sensitivity and 100% specificity). CONCLUSION: In summary, we concluded that heel pain can be efficiently examined by both ultrasound (US) and shear wave elastography (SWE) with the former being used as the primary effective tool and the latter being done to increase diagnostic accuracy. We also concluded that SWE improved the ultrasound's diagnostic precision in identifying patients with early plantar fasciitis and Achilles tendinopathy and showed a robust relationship with clinical outcomes, enhancing patient evaluation and follow-up.

2.
Clin Res Cardiol ; 113(7): 1081-1091, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38832995

RESUMO

BACKGROUND: Despite the recommendation of coronary physiology to guide revascularization in angiographically intermediate stenoses without established correlation to ischemia, its uptake in clinical practice is slow. AIMS: This study aimed to analyze the use of coronary physiology in clinical practice. METHODS: Based on a multicenter registry (Fractional Flow Reserve Fax Registry, F(FR)2, ClinicalTrials.gov identifier NCT03055910), clinical use, consequences, and complications of coronary physiology were systematically analyzed. RESULTS: F(FR)2 enrolled 2,000 patients with 3,378 intracoronary pressure measurements. Most measurements (96.8%) were performed in angiographically intermediate stenoses. Out of 3,238 lesions in which coronary physiology was used to guide revascularization, revascularization was deferred in 2,643 (78.2%) cases. Fractional flow reserve (FFR) was the most common pressure index used (87.6%), with hyperemia induced by an intracoronary bolus of adenosine in 2,556 lesions (86.4%) and intravenous adenosine used for 384 measurements (13.0%). The route of adenosine administration did not influence FFR results (change-in-estimate -3.1% for regression model predicting FFR from diameter stenosis). Agreement with the subsequent revascularization decision was 93.4% for intravenous and 95.0% for intracoronary adenosine (p = 0.261). Coronary artery occlusion caused by the pressure wire was reported in two cases (0.1%) and dissection in three cases (0.2%), which was fatal once (0.1%). CONCLUSIONS: In clinical practice, intracoronary pressure measurements are mostly used to guide revascularization decisions in angiographically intermediate stenoses. Intracoronary and intravenous administration of adenosine seem equally suited. While the rate of serious complications of wire-based intracoronary pressure measurements in clinical practice seems to be low, it is not negligible.


Assuntos
Angiografia Coronária , Estenose Coronária , Vasos Coronários , Reserva Fracionada de Fluxo Miocárdico , Sistema de Registros , Humanos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Masculino , Feminino , Estenose Coronária/fisiopatologia , Estenose Coronária/diagnóstico , Pessoa de Meia-Idade , Vasos Coronários/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Idoso , Adenosina/administração & dosagem , Revascularização Miocárdica/métodos , Cateterismo Cardíaco/métodos , Vasodilatadores/administração & dosagem
3.
Diagnostics (Basel) ; 14(2)2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-38248031

RESUMO

BACKGROUND: Coronary computed tomography angiography (CCTA) provides non-invasive quantitative assessments of plaque burden and composition. The quantitative assessment of plaque components requires the use of analysis software that provides reproducible semi-automated plaque detection and analysis. However, commercially available plaque analysis software can vary widely in the degree of automation, resulting in differences in terms of reproducibility and time spent. AIM: To compare the reproducibility and time spent of two CCTA analysis software tools using different algorithms for the quantitative assessment of coronary plaque volumes and composition in two independent patient cohorts. METHODS: The study population included 100 patients from two different cohorts: 50 patients from a single-center (Siemens Healthineers, SOMATOM Force (DSCT)) and another 50 patients from a multi-center study (5 different > 64 slice CT scanner types). Quantitative measurements of total calcified and non-calcified plaque volume of the right coronary artery (RCA), left anterior descending (LAD), and left circumflex coronary artery (LCX) were performed on a total of 300 coronaries by two independent readers, using two different CCTA analysis software tools (Tool #1: Siemens Healthineers, syngo.via Frontier CT Coronary Plaque Analysis and Tool #2: Siemens Healthineers, successor CT Coronary Plaque Analysis prototype). In addition, the total time spent for the analysis was recorded with both programs. RESULTS: The patients in cohorts 1 and 2 were 62.8 ± 10.2 and 70.9 ± 11.7 years old, respectively, 10 (20.0%) and 35 (70.0%) were female and 34 (68.0%) and 20 (40.0%), respectively, had hyperlipidemia. In Cohort #1, the inter- and intra-observer variabilities for the assessment of plaque volumes per patient for Tool #1 versus Tool #2 were 22.8%, 22.0%, and 26.0% versus 2.3%, 3.9%, and 2.5% and 19.7%, 21.4%, and 22.1% versus 0.2%, 0.1%, and 0.3%, respectively, for total, noncalcified, and calcified lesions (p < 0.001 for all between Tools #1 and 2 both for inter- and intra-observer). The inter- and intra-observer variabilities using Tool #2 remained low at 2.9%, 2.7%, and 3.0% and 3.8%, 3.7%, and 4.0%, respectively, for total, non-calcified, and calcified lesions in Cohort #2. For each dataset, the median processing time was higher for Tool #1 versus Tool #2 (459.5 s IQR = 348.0-627.0 versus 208.5 s; IQR = 198.0-216.0) (p < 0.001). CONCLUSION: The plaque analysis Tool #2 (CT-guided PCI) encompassing a higher degree of automated support required less manual editing, was more time-efficient, and showed a higher intra- and inter-observer reproducibility for the quantitative assessment of plaque volumes both in a representative single-center and in a multi-center validation cohort.

4.
Clin Res Cardiol ; 113(1): 29-37, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37022472

RESUMO

AIMS: Transcatheter aortic valve implantation (TAVI) has become a minimally invasive alternative to surgical aortic valve replacement. Hypo-attenuated leaflet thickening (HALT)-a marker of subclinical leaflet thrombosis commonly detected by cardiac computed tomography (CT) after TAVI-may influence valve durability and function. The purpose of this study was to compare commissural alignment of the native and prosthetic aortic valves in cardiac CT in subjects with and without HALT and thereby identify commissural misalignment as potential predictor for leaflet thrombosis after TAVI. METHODS AND RESULTS: In 170 subjects, 85 with and 85 without HALT in post-TAVI CT, commissural orientation of the prosthesis was determined comparing native and prosthetic aortic valve orientation in cardiac CT by measuring the commissural angle relative to the right coronary ostium in the aortic valve plane. For the prosthetic valve, any deviation ≤ 15° compared to the native valve was classified as "aligned"; 16-30° as "mild", 31-45° as "moderate" and ≥ 45° as "severe" misalignment. Among subjects with HALT, median angular deviation was higher (36°, IQR 31°) than in the control group (29°, IQR 29°, p = 0.042). "Severe" misalignment was more frequent in subjects who developed HALT (n = 31, 37%) compared to the control group (n = 17, 20%, p = 0.013). In logistic regression analysis, more severe deviation (p = 0.015, OR = 1.02 per 1° deviation) and "severe" misalignment (p = 0.018, OR = 2.2) represented independent predictors for the occurrence of HALT after TAVI. CONCLUSION: Subclinical leaflet thrombosis after TAVI is associated with commissural misalignment. Potential clinical advantages of obtaining commissural alignment remain to be systematically assessed.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Trombose/epidemiologia , Resultado do Tratamento
5.
JACC Cardiovasc Interv ; 16(16): 1965-1973, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-37648344

RESUMO

BACKGROUND: Patients with severe aortic regurgitation (AR) are often not considered for surgery because of increased surgical risk. Because of unique anatomical characteristics among patients with AR, interventional treatment options are limited, and implantation results are inconsistent compared with those among patients with aortic stenosis. OBJECTIVES: The authors describe the initial commercial experience of the first Conformité Européenne-marked transfemoral transcatheter aortic valve replacement system (JenaValve Trilogy [JV]) for the treatment of patients with AR. METHODS: This multicenter registry included 58 consecutive patients from 6 centers across Germany. Transcatheter aortic valve replacement was performed with the JV system for isolated severe and symptomatic AR. Patient characteristics, primary implantation outcomes, and valve performance up to 30 days were analyzed using Valve Academic Research Consortium 3 definitions. RESULTS: The mean patient age was 76.5 ± 9 years, with a mean Society of Thoracic Surgeons score of 4.2% ± 4.3%. Device success was achieved in 98% of patients. The mean gradient was 4.3 ± 1.6 mm Hg, and no moderate or severe paravalvular regurgitation occurred. No conversion to open heart surgery or valve embolization was reported. There were no major vascular complications or bleeding events. The rate of new permanent pacemaker implantation was 19.6%. At 30 days, 92% of the patients were in NYHA functional class I or II, and the 30-day mortality rate was 1.7%. CONCLUSIONS: Treatment of patients with severe symptomatic AR using the transfemoral JV system is safe and effective. Given its favorable hemodynamic performance and low complication rates, this system may offer a new treatment option for patients with AR not suitable for surgery.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Coração , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia
6.
Int J Cardiol Heart Vasc ; 45: 101175, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37070121

RESUMO

Background: European Society of Cardiology (ESC) clinical practice guidelines are currently considered as an essential tool supporting many cardiologists in clinical decision-making not only in Europe but all-over the world. In this study we analyzed these recommendations regarding their class of recommendations (COR) and level of evidence (LOE) to detect how solid is the scientific background behind these recommendations. Methods: We have abstracted all the current guidelines defined as "the guidelines available on the ESC website by 01 October 2022". All recommendations were classified according to their COR (Class I, IIa, IIb, or III) and LOE (A, B, or C). As every topic has different number of recommendations, we have used the median values in comparisons between different topics to give all the topics the same weight. Results: Current ESC guidelines consist of 37 clinical topics including a total of 4289 recommendations. Their distribution was 2140 with a median of 49.9% in Class I, Class II and Class III were 1825 with a median of 42.6% and 324 with a median of 7.5% respectively. LOE A was only present in 667(15.5%) recommendations, 1285(30%) in LOE B, while LOE C was behind the majority of the recommendations, 2337 with a median of 54.5%. Conclusion: Although ESC guidelines are considered a gold standard for management of cardiovascular diseases, but surprisingly more than half of its recommendations are based on such scientific evidence. Deficiency in clinical trials is not the same across all guideline's topics, some are needier for clinical research.

7.
J Cardiovasc Comput Tomogr ; 17(2): 86-95, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36934047

RESUMO

This review aims to summarize key articles published in the Journal of Cardiovascular Computed Tomography (JCCT) in 2022, focusing on those that had the most scientific and educational impact. The JCCT continues to expand; the number of submissions, published manuscripts, cited articles, article downloads, social media presence, and impact factor continues to grow. The articles selected by the Editorial Board of the JCCT in this review highlight the role of cardiovascular computed tomography (CCT) to detect subclinical atherosclerosis, assess the functional relevance of stenoses, and plan invasive coronary and valve procedures. A section is dedicated to CCT in infants and other patients with congenital heart disease, in women, and to the importance of training in CT. In addition, we highlight key consensus documents and guidelines published in JCCT last year. The Journal values the tremendous work by authors, reviewers, and editors to accomplish these contributions.


Assuntos
Estenose da Valva Aórtica , Sistema Cardiovascular , Substituição da Valva Aórtica Transcateter , Feminino , Humanos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Angiografia por Tomografia Computadorizada , Constrição Patológica , Coração , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X/métodos , Substituição da Valva Aórtica Transcateter/métodos
8.
J Thorac Imaging ; 38(1): 46-53, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36490312

RESUMO

BACKGROUND: Increased pericoronary adipose tissue (PCAT) attenuation derived from coronary computed tomography (CT) angiography (CTA) relates to coronary inflammation and cardiac mortality. We aimed to investigate the association between CT-derived characterization of different cardiac fat compartments and myocardial ischemia as assessed by computed fractional flow reserve (FFRCT). METHODS: In all, 133 patients (median 64 y, 74% male) with coronary artery disease (CAD) underwent CTA including FFRCT measurement followed by invasive FFR assessment (FFRINVASIVE). CT attenuation and volume of PCAT were quantified around the proximal right coronary artery (RCA), left anterior descending artery (LAD), and left circumflex artery (LCX). Epicardial adipose tissue (EAT) and paracardial adipose tissue (PAT; all intrathoracic adipose tissue outside the pericardium) were quantified in noncontrast cardiac CT datasets. RESULTS: Median FFRCT was 0.86 [0.79, 0.91] and median FFRINVASIVE was 0.87 [0.81, 0.93]. Subjects with the presence of myocardial ischemia (n=26) defined by an FFRCT-threshold of ≤0.75 showed significantly higher RCA PCAT attenuation than individuals without myocardial ischemia (n=107) (-75.1±10.8 vs. -81.1±10.6 HU, P=0.011). In multivariable analysis adjusted for age, body mass index, sex and risk factors, increased RCA PCAT attenuation remained a significant predictor of myocardial ischemia. Between individuals with myocardial ischemia compared with individuals without myocardial ischemia, there was no significant difference in the volume and CT attenuation of EAT and PAT or in the PCAT volume of RCA, LAD, and LCX. CONCLUSIONS: Increased RCA PCAT attenuation is associated with the presence of myocardial ischemia as assessed by FFR, while PCAT volume, EAT, and PAT are not.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Humanos , Masculino , Feminino , Doença da Artéria Coronariana/diagnóstico por imagem , Angiografia Coronária/métodos , Angiografia por Tomografia Computadorizada/métodos , Vasos Coronários , Tomografia Computadorizada por Raios X/métodos , Tecido Adiposo/diagnóstico por imagem , Valor Preditivo dos Testes
9.
Life (Basel) ; 12(11)2022 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-36362887

RESUMO

Metabolic dysfunctions linked to obesity carry the risk of co-morbidities such as diabetes, hepatorenal, and cardiovascular diseases. Coumarins are believed to display several biological effects on diverse adverse health conditions. This study was conducted to uncover the impact of cichoriin on high-fat diet (HFD)-induced obese rats. Methods: Obesity was induced in twenty rats by exposure to an HFD for six weeks. The rats were randomly divided into five groups; group I comprised five healthy rats and was considered the control one. On the other hand, the HFD-induced rats were divided into the following (five per each group): group II (the HFD group), groups III (cichoriin 50 mg/kg) and IV (cichoriin 100 mg/kg) as the treatment groups, and group V received atorvastatin (10 mg/kg) (as a standard). Triglycerides (TG), total cholesterol (TC), high-density lipoprotein cholesterol (HDL-C), low-density lipoprotein cholesterol (LDL-C), alanine transaminase (ALT), aspartate transaminase (AST), creatine kinase MB (CK-MB), urea, creatinine, the hepatic and renal malondialdehyde (MDA) as well as reduced glutathione (GSH) levels were assessed. Histopathological analysis of the heart, kidney, and liver tissues was investigated. mRNA and protein expressions of the peroxisome proliferator-activated receptor gamma (PPAR-γ) were estimated. Results: The administration of cichoriin alleviated HFD-induced metabolic dysfunctions and improved the histopathological characteristics of the heart, kidney, and liver. Additionally, the treatment improved the lipid profile and hepatic and renal functions, as well as the oxidative balance state. Cichoriin demonstrated an upregulation of the mRNA and protein expressions of PPAR-γ. Taken together, these findings are the first report on the beneficial role of cichoriin in alleviating adverse metabolic effects in HFD-induced obesity and adapting it into an innovative obesity management strategy.

10.
Catheter Cardiovasc Interv ; 100(3): 369-377, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35723275

RESUMO

OBJECTIVES AND BACKGROUND: This study aims to evaluate whether the high correlation and classification agreement of the instantaneous wave-free ratio (iFR) and the resting distal coronary to aortic pressure ratio (Pd /Pa ) with the fractional flow reserve (FFR) can be confirmed in stent-jailed side branches (J-SB). METHODS: Consecutive patients (n = 49) undergoing provisional stenting were prospectively enrolled and a physiological assessment of the J-SB (n = 51) was performed. FFR, iFR, and Pd /Pa were measured and the hemodynamic relevance was determined using cutoff values of ≤0.80, ≤0.89, and ≤0.92, respectively. RESULTS: Both iFR (r = 0.75) and Pd /Pa (r = 0.77) correlated closely with FFR. Classification agreement with FFR was 78% for iFR (81% sensitivity, 77% specificity) and 75% for Pd /Pa (63% sensitivity and 80% specificity). However, angiographic diameter stenosis and pressure indices correlated poorly. For a threshold of ≥70% stenosis, agreement concerning hemodynamic relevance was found in 59% for FFR, 69% for iFR, and 61% for Pd /Pa . CONCLUSION: As reported for other lesion types, FFR and the adenosine-independent pressure indices iFR and Pd /Pa show close correlation and a high classification agreement of approximately 75%-80% in J-SB. Therefore, iFR can be regarded as a recommendable alternative to FFR for the guidance of provisional stenting in bifurcation lesions.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Hiperemia , Adenosina , Cateterismo Cardíaco , Constrição Patológica , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Humanos , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Stents , Resultado do Tratamento
11.
JACC Cardiovasc Imaging ; 15(5): 859-871, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35512957

RESUMO

OBJECTIVES: The aim of this study was to precisely phenotype culprit and nonculprit lesions in myocardial infarction (MI) and lesions in stable coronary artery disease (CAD) using coronary computed tomography angiography (CTA)-based radiomic analysis. BACKGROUND: It remains debated whether any single coronary atherosclerotic plaque within the vulnerable patient exhibits unique morphology conferring an increased risk of clinical events. METHODS: A total of 60 patients with acute MI prospectively underwent coronary CTA before invasive angiography and were matched to 60 patients with stable CAD. For all coronary lesions, high-risk plaque (HRP) characteristics were qualitatively assessed, followed by semiautomated plaque quantification and extraction of 1,103 radiomic features. Machine learning models were built to examine the additive value of radiomic features for discriminating culprit lesions over and above HRP and plaque volumes. RESULTS: Culprit lesions had higher mean volumes of noncalcified plaque (NCP) and low-density noncalcified plaque (LDNCP) compared with the highest-grade stenosis nonculprits and highest-grade stenosis stable CAD lesions (NCP: 138.1 mm3 vs 110.7 mm3 vs 102.7 mm3; LDNCP: 14.2 mm3 vs 9.8 mm3 vs 8.4 mm3; both Ptrend < 0.01). In multivariable linear regression adjusted for NCP and LDNCP volumes, 14.9% (164 of 1,103) of radiomic features were associated with culprits and 9.7% (107 of 1,103) were associated with the highest-grade stenosis nonculprits (critical P < 0.0007) when compared with highest-grade stenosis stable CAD lesions as reference. Hierarchical clustering of significant radiomic features identified 9 unique data clusters (latent phenotypes): 5 contained radiomic features specific to culprits, 1 contained features specific to highest-grade stenosis nonculprits, and 3 contained features associated with either lesion type. Radiomic features provided incremental value for discriminating culprit lesions when added to a machine learning model containing HRP and plaque volumes (area under the receiver-operating characteristic curve 0.86 vs 0.76; P = 0.004). CONCLUSIONS: Culprit lesions and highest-grade stenosis nonculprit lesions in MI have distinct radiomic signatures compared with lesions in stable CAD. Within the vulnerable patient may exist individual vulnerable plaques identifiable by coronary CTA-based precision phenotyping.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Infarto do Miocárdio , Placa Aterosclerótica , Angiografia por Tomografia Computadorizada , Constrição Patológica/complicações , Angiografia Coronária/métodos , Doença da Artéria Coronariana/complicações , Estenose Coronária/complicações , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Humanos , Infarto do Miocárdio/complicações , Valor Preditivo dos Testes
12.
Atherosclerosis ; 350: 25-32, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35483115

RESUMO

BACKGROUND AND AIMS: Various pro- and anti-inflammatory biomarkers are involved in the process of atherosclerosis. We analyzed the association of different biomarkers with coronary plaque volume and vulnerable plaque subcomponents. METHODS: In 301 patients undergoing coronary CT angiography (CTA), total coronary plaque volume (TPV) and subcomponents including non-calcified plaque volume (NCPV) and vulnerable plaque burden were quantified using semi-automated software. Serum was analyzed for various cytokines. RESULTS: Out of 301 patients, 207 (69%) were male. The mean age was 59 ± 10 years. Patients were divided using the median of TPV, NCPV and vulnerable plaque burden. In univariable analysis, patients with high TPV, high NCPV and high vulnerable plaque burden showed significant higher serum levels for IFNƔ, IL-1a, -2, -4, -10 and -17 and significant lower levels for IL-8 and MCP-1 (all p < 0.05). Multivariable analysis showed positive associations between high vulnerable plaque burden, IL-1a (OR 2.60, p = 0.001) and Eotaxin (OR 1.89, p = 0.020), and inverse association to MCP-1 (OR 0.33, p < 0.001), independent of age, gender and CVRF. In exploratory subanalyses, patients with presence of atherosclerosis (n = 247; 82%) showed significantly higher levels of IL-17 in all subgroups with high vulnerable plaque burden, irrespective of overall plaque volume (all p < 0.001). CONCLUSIONS: The cytokine profile significantly differs between patients with high and low coronary plaque volume. IL-1a and IL-17 seem to play a major proatherogenic role in vulnerable plaque formation, whereas MCP-1 paradoxically portends protective effects. Longitudinal studies with serial cytokine testing are needed to identify potential targets for therapeutic interventions.


Assuntos
Aterosclerose , Doença da Artéria Coronariana , Placa Aterosclerótica , Idoso , Biomarcadores , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Interleucina-17 , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos
13.
J Cardiovasc Comput Tomogr ; 16(3): 266-276, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35370125

RESUMO

This review aims to summarize original articles published in the Journal of Cardiovascular Computed Tomography (JCCT) for the year 2021, focusing on those that had the most scientific and educational impact. The JCCT continues to expand; the number of submissions, published manuscripts, cited articles, article downloads, social media presence, and impact factor continues to increase. The articles selected by the Editorial Board of the JCCT in this review focus on coronary artery disease, coronary physiology, structural heart disease, and technical advances in cardiovascular CT. In addition, we highlight key consensus documents and guidelines published in the Journal in 2021. The Journal recognizes the tremendous work done by each author and reviewer this year - thank you.


Assuntos
Doenças Cardiovasculares , Fator de Impacto de Revistas , Doenças Cardiovasculares/diagnóstico por imagem , Humanos , Valor Preditivo dos Testes , Prognóstico , Tomografia Computadorizada por Raios X
14.
JACC Cardiovasc Interv ; 15(5): 496-507, 2022 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-35272774

RESUMO

OBJECTIVES: The aim of this study was to examine the predictive value of preprocedural computed tomography (CT)-based risk stratification of coronary obstruction during transcatheter aortic valve replacement (TAVR) on the basis of geometric measurements on postprocedural CT. BACKGROUND: Proper patient selection for additional procedures to prevent coronary obstruction during TAVR has not been adequately evaluated. METHODS: Pre- and postprocedural computed tomographic scans of 28 patients treated using bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction (BASILICA) and TAVR were analyzed. Using the postprocedural computed tomographic images, threatened coronary obstruction (TCO) was defined as: 1) ostial obstruction (adherence of the transcatheter heart valve [THV] to the coronary ostium with leaflet extension above the ostium); and/or 2) sinus sequestration (THV adherence to the sinotubular junction [STJ] with leaflet extension above the STJ) and was substratified into complete and incomplete types. RESULTS: A total of 51 leaflets were evaluated (88% surgical tissue valves) after excluding leaflets not visible on CT (n = 5). On postprocedural CT, complete TCO was observed in 25.4% (13 of 51 leaflets). On preprocedural CT, leaflets were at high risk for complete TCO (incidence 53%) if the virtual THV-to-coronary distance (VTC) was <3.0 mm, or if the virtual THV-to-STJ distance (VTSTJ) was <1.0 mm with STJ height - leaflet length <0 mm (leaflet-STJ mismatch). Leaflets were at low risk (incidence 0%) if the VTC was ≥3 mm and VTSTJ was ≥3.0 mm or STJ height - leaflet length was ≥+2.0 mm. Of 28 leaflets treated using BASILICA, complete TCO was seen in 35.7% (n = 10), due to sinus sequestration (100%) with coexisting ostial obstruction (30%). Actual coronary events occurred in 7.1% (n = 2) because of leaflet prolapse, corresponding to an absolute risk reduction by BASILICA of 29% (P = 0.021). CONCLUSIONS: Risk assessment of coronary obstruction after TAVR may improve with a multiparametric approach incorporating VTC, VTSTJ, and leaflet-STJ mismatch. BASILICA appeared to reduce actual coronary events even in leaflets with anticipated coronary obstruction.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Medição de Risco , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
15.
Heart Vessels ; 37(9): 1478-1488, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35305131

RESUMO

Radial access is recommended for percutaneous coronary intervention (PCI), but rotational atherectomy remains frequently performed via femoral access. Analyzing the procedural parameters, success rate and complications of rotational atherectomy, performed via radial in comparison to femoral access. We retrospectively analyzed 427 consecutive patients undergoing rotational atherectomy. Procedural parameters and outcome were determined in 171 patients, scheduled for radial and compared to 256 patients with femoral access use. In the radial access group (74 ± 9 years, 84% male), the LAD was most frequently treated (49%). Sheath size was 7F in 59% and 6F in 41%, burr size was 1.5 mm in 46% and 1.25 mm in 14% of patients. A temporary pacemaker was inserted in 14%. Procedural success rate stood at 97%. Access site complications occurred in 4% of patients, which was significantly less frequent than in in 256 patients treated via femoral access (13% p = 0.003). Compared to radial access, femoral access was associated with the use of larger sheaths (p < 0.001), more frequent treatment of non-LAD vessels (58.2% vs. 44.4%, p = 0.013) and a higher rate of temporary pacemaker use (27%; p = 0.001). No differences could be seen in procedural success (p = 0.83) and burr size (p = 0.51). Femoral access (OR 3.33; 95% CI 1.40-7.93), and female sex (OR3.40 95% CI 1.69-6.63) were independent predictors for access site complications. For coronary rotational atherectomy, radial access has a high success rate with overall use of smaller sheaths, but of equally sized burrs as well as a significant lower rate of access site-related complications than femoral access.


Assuntos
Aterectomia Coronária , Intervenção Coronária Percutânea , Aterectomia Coronária/efeitos adversos , Feminino , Artéria Femoral , Humanos , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Artéria Radial , Estudos Retrospectivos , Resultado do Tratamento
16.
Lancet Digit Health ; 4(4): e256-e265, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35337643

RESUMO

BACKGROUND: Atherosclerotic plaque quantification from coronary CT angiography (CCTA) enables accurate assessment of coronary artery disease burden and prognosis. We sought to develop and validate a deep learning system for CCTA-derived measures of plaque volume and stenosis severity. METHODS: This international, multicentre study included nine cohorts of patients undergoing CCTA at 11 sites, who were assigned into training and test sets. Data were retrospectively collected on patients with a wide range of clinical presentations of coronary artery disease who underwent CCTA between Nov 18, 2010, and Jan 25, 2019. A novel deep learning convolutional neural network was trained to segment coronary plaque in 921 patients (5045 lesions). The deep learning network was then applied to an independent test set, which included an external validation cohort of 175 patients (1081 lesions) and 50 patients (84 lesions) assessed by intravascular ultrasound within 1 month of CCTA. We evaluated the prognostic value of deep learning-based plaque measurements for fatal or non-fatal myocardial infarction (our primary outcome) in 1611 patients from the prospective SCOT-HEART trial, assessed as dichotomous variables using multivariable Cox regression analysis, with adjustment for the ASSIGN clinical risk score. FINDINGS: In the overall test set, there was excellent or good agreement, respectively, between deep learning and expert reader measurements of total plaque volume (intraclass correlation coefficient [ICC] 0·964) and percent diameter stenosis (ICC 0·879; both p<0·0001). When compared with intravascular ultrasound, there was excellent agreement for deep learning total plaque volume (ICC 0·949) and minimal luminal area (ICC 0·904). The mean per-patient deep learning plaque analysis time was 5·65 s (SD 1·87) versus 25·66 min (6·79) taken by experts. Over a median follow-up of 4·7 years (IQR 4·0-5·7), myocardial infarction occurred in 41 (2·5%) of 1611 patients from the SCOT-HEART trial. A deep learning-based total plaque volume of 238·5 mm3 or higher was associated with an increased risk of myocardial infarction (hazard ratio [HR] 5·36, 95% CI 1·70-16·86; p=0·0042) after adjustment for the presence of deep learning-based obstructive stenosis (HR 2·49, 1·07-5·50; p=0·0089) and the ASSIGN clinical risk score (HR 1·01, 0·99-1·04; p=0·35). INTERPRETATION: Our novel, externally validated deep learning system provides rapid measurements of plaque volume and stenosis severity from CCTA that agree closely with expert readers and intravascular ultrasound, and could have prognostic value for future myocardial infarction. FUNDING: National Heart, Lung, and Blood Institute and the Miriam & Sheldon G Adelson Medical Research Foundation.


Assuntos
Aprendizado Profundo , Placa Aterosclerótica , Angiografia por Tomografia Computadorizada , Constrição Patológica/complicações , Humanos , Placa Aterosclerótica/complicações , Placa Aterosclerótica/diagnóstico por imagem , Estudos Prospectivos , Estudos Retrospectivos
17.
Eur Radiol ; 32(4): 2604-2610, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34735608

RESUMO

OBJECTIVES: We evaluated the influence of image reconstruction kernels on the diagnostic accuracy of CT-derived fractional flow reserve (FFRCT) compared to invasive FFR in patients with coronary artery disease. METHODS: Sixty-nine patients, in whom coronary CT angiography was performed and who were further referred for invasive coronary angiography with FFR measurement via pressure wire, were retrospectively included. CT data sets were acquired using a third-generation dual-source CT system and rendered with medium smooth (Bv40) and sharp (Bv49) reconstruction kernels. FFRCT was calculated on-site using prototype software. Coronary stenoses with invasive FFR ≤ 0.80 were classified as significant. Agreement between FFRCT and invasive FFR was determined for both reconstruction kernels. RESULTS: One hundred analyzed vessels in 69 patients were included. Twenty-five vessels were significantly stenosed according to invasive FFR. Using a sharp reconstruction kernel for FFRCT resulted in a significantly higher correlation with invasive FFR (r = 0.74, p < 0.01 vs. r = 0.58, p < 0.01; p = 0.04) and a higher AUC in ROC curve analysis to correctly identify/exclude significant stenosis (AUC = 0.92 vs. AUC = 0.82 for sharp vs. medium smooth kernel, respectively, p = 0.02). A FFRCT value of ≤ 0.8 using a sharp reconstruction kernel showed a sensitivity of 88% and a specificity of 92% for detecting ischemia-causing lesions, resulting in a diagnostic accuracy of 91%. The medium smooth reconstruction kernel performed worse (sensitivity 60%, specificity 89%, accuracy 82%). CONCLUSION: Compared to invasively measured FFR, FFRCT using a sharp image reconstruction kernel shows higher diagnostic accuracy for detecting lesions causing ischemia, potentially altering decision-making in a clinical setting. KEY POINTS: • Image reconstruction parameters influence the diagnostic accuracy of simulated fractional flow reserve derived from coronary computed tomography angiography. • Using a sharp kernel image reconstruction algorithm delivers higher diagnostic accuracy compared to medium smooth kernel image reconstruction (gold standard invasive fractional flow reserve).


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Vasos Coronários , Humanos , Valor Preditivo dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X
18.
Cardiovasc Diagn Ther ; 12(6): 787-802, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36605074

RESUMO

Background: Aortic aneurysm and aortic dissection can have a major impact on the life expectancy of Marfan syndrome (MFS) or Loeys-Dietz syndrome (LDS) patients. Although obesity can influence the development of aortic complications, evidence on whether obesity influences the development of aortic aneurysm or dissection in MFS and LDS is limited. The aim of the present study was to elucidate the relationship between aortic size and body composition, assessed by modern bioelectrical impedance analysis (BIA) in MFS/LDS-patients. Methods: In this exploratory cross-sectional study in MFS or LDS patients, enrolled between June 2020 and May 2022, 34 patients received modern BIA and magnetic resonance imaging (MRI) (n=32) or computed tomography (CT) imaging (n=2) of the entire aorta. A P value of <0.05 was considered significant. Results: Fifty-one patients (66% female; mean age: 37.7±11.7; range, 17-68 years) with MFS or LDS were enrolled; 34 patients, 27 with MFS and 7 with LDS, underwent aortic MRI or CT scanning. The mean aortic length was 503.7±58.7 mm, and the mean thoracic aortic length and abdominal aortic length were 351.5±52.4 and 152.2±27.4 mm, respectively. The aortic bulb and the ascending aorta were measured only in the non-surgically repaired patients. Fifteen MFS (88.2%) and two LDS (40.0%) patients had an aortic aneurysm. In these, the aortic bulb tended to be larger in MFS than in LDS patients [42.6×41.9×41.2 vs. 37.8×37.4×36.8 mm; P=0.07 (-1.1; 9.1); P=0.07 (-1.2; 8.4); P=0.07 (-1.5; 7.9)]. BIA revealed mean body fat levels of 31.6%±8.7% (range, 9.5-53.5%), indicating that 18 patients (52.9%) were obese. There was a significant correlation between body fat content and thoracic aortic length (R=-0.377; P=0.02), muscle mass and total aortic length (R=0.359; P=0.03), thoracic aortic length (R=0.399; P=0.02), extracellular mass (ECM), and total aortic length (R=0.354; P=0.04), and connective tissue and aortic diameters at the aortic arch (R=0.511; P=0.002), aortic isthmus (R=0.565; P<0.001), and abdominal aorta (R=0.486; P=0.004). Older age was correlated with wider aortic arch, isthmus, and abdominal aorta. Male patients had a longer aorta. Conclusions: While a slender habitus is commonly known for MFS and LDS patients, our data show that many MFS and LDS patients (especially female) do not fit this phenotypic characteristic and are obese, which is associated with a more severe aortic phenotype. This topic should be included in the clinical assessment of affected MFS and LDS patients, in addition to measurement of the aortic diameters. Physicians should systematically screen MFS and LDS patients for obesity, educate them about the potential risk of resulting aortic complications, and encourage them to adopt a healthy lifestyle, that includes (mild) exercise and a balanced diet.

19.
Ann Med Surg (Lond) ; 69: 102698, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34484719

RESUMO

INTRODUCTION: Bariatric and metabolic procedures are becoming more common worldwide and laparoscopic surgery is the primary method to perform these operations. Accessing the peritoneum remains a challenge in obese patients and this study aims to assess the safety of optical trocars in bariatric surgery. METHODS: A retrospective study was conducted on all patients that have undergone bariatric surgery in our center between the years of 2017-2019 to examine the method by which pneumoperitoneum was established. We studied the incidence and type of complications associated with creating pneumoperitoneum in obese patients, along with the rates of converting to an open procedure. RESULTS: A total of 821 patients underwent bariatric surgery in our center over the 3 year period. They had an average age of 34.2 years (range = 13-65) with an average BMI of 45.9 kg/m2. Optical trocars successfully established pneumoperitoneum in all these patients. Complications attributed to optical trocar entry were encountered in 8 patients (0.97%), 3 males and 5 females. The average BMI of these 8 patients is 52.7 kg/m2, 4 of which had a BMI >50 kg/m2. The complications encountered included 3 liver lacerations, 4 mesenteric injuries and 1 omental vessel laceration. Four injuries were caused by 12 mm optical trocars while the other 4 injuries were caused by 5 mm optical trocars. These complications were managed laparoscopically and no patients had to be converted to a laparotomy. CONCLUSION: The use of non-bladed, optical trocar entry into the abdomen can be considered a safe method in the establishment of pneumoperitoneum in patients with obesity. However, more studies are required randomizing the use of optical trocars to the open Hasson technique in order to further validate this method.

20.
Dtsch Med Wochenschr ; 146(16): 1035-1040, 2021 08.
Artigo em Alemão | MEDLINE | ID: mdl-34416770

RESUMO

Cardiovascular imaging has experienced and is still experiencing tremendous advancements as far as hardware as well as software technology is concerned. In every day clinical routine, crucial decisions are daily being taken based on imaging findings. These decisions include changes to treatment strategies, performing further testing, recommending or adhering to preventive measures, and ultimately affect patient outcomes. Appropriate use of different imaging modalities which includes choosing the right modality, adequate performance of the imaging test as well as professional reporting is crucial for providing high quality medical care. Furthermore, a growing body of scientific evidence is currently available that show the clinical relevance of different imaging methods in the clarification of different disease constellations. This article describes various imaging modalities that are used in the work-up of CAD in everyday cardiac routine.


Assuntos
Técnicas de Imagem Cardíaca/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Humanos , Imageamento por Ressonância Magnética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...