1.
Osteoarthritis Cartilage ; 14(1): 63-70, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16188466

RESUMO

OBJECTIVE: To use receiver operator characteristics (ROC) analysis for assessing the diagnostic performance of three cartilage-specific MR sequences at 1.5 and 3 T in detecting cartilage lesions created in porcine knees. DESIGN: Eighty-four cartilage lesions were created in 27 porcine knee specimens at the patella, the medial and lateral femoral and the medial and lateral tibial cartilage. MR imaging was performed using a fat saturated spoiled gradient echo (SPGR) sequence (in plane spatial resolution/slice thickness: 0.20 x 0.39 mm2/1.5 mm) and two fat saturated proton density weighted (PDw) sequences (low spatial resolution: 0.31 x 0.47 mm2/3 mm and high spatial resolution: 0.20 x 0.26 mm2/2 mm). The images were independently analyzed by three radiologists concerning the absence or presence of lesions using a five-level confidence scale. Significances of the differences for the individual sequences were calculated based on comparisons of areas under ROC curves (A(Z)). RESULTS: The highest A(Z)-values for all three radiologists were consistently obtained for the SPGR (A(Z) = 0.84) and the high-resolution (hr) PDw (A(Z) = 0.79) sequences at 3T. The corresponding A(Z)-values at 1.5 T were 0.77 and 0.69; the differences between 1.5 and 3 T were statistically significant (P < 0.05). A(Z)-values for the low-resolution PDw sequence were lower: 0.59 at 3 T and 0.55 at 1.5 T and the differences between 1.5 and 3T were not significant. CONCLUSION: With optimized hr MR sequences diagnostic performance in detecting cartilage lesions was improved at 3 T. For a standard, lower spatial resolution PDw sequence no significant differences, however, were found.


Assuntos
Doenças das Cartilagens/patologia , Cartilagem Articular/patologia , Imageamento por Ressonância Magnética/métodos , Curva ROC , Animais , Modelos Animais de Doenças , Fêmur , Membro Posterior , Articulações/patologia , Patela , Reprodutibilidade dos Testes , Suínos , Tíbia
2.
Calcif Tissue Int ; 76(5): 355-64, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15868282

RESUMO

The purpose of this study is to use high-resolution magnetic resonance (MR) imaging at 3 Tesla (3T) to quantify trabecular bone structure in vitro using femoral head specimens, and to correlate the calculated structure measures with those that were determined using microcomputed tomography (microCT), the standard of reference. Fifteen cylindrical cores were obtained from fresh femoral heads after total hip arthroplasty. MR images were obtained at 3T using a transmit-receive wrist coil. High-resolution coronal images were acquired using a modified three-dimensional (3D) fast-gradient echo sequence. From these data sets two-dimensional (2D) structural parameters analogous to bone histomorphometry were derived by using both mean intercept length (MIL) methods based on the plate model and the more recent model-assumption free 3D distance-transformation (DT) methods. The parameters measured by the 2D plate model-based MIL method and the DT method included apparent (App). BV/TV (bone volume/total volume), App. Tb.Th (trabecular thickness), App. Tb.Sp (trabecular separation), and App. Tb.N (trabecular number). Identical regions of interest were analyzed in the MR images and the microCT data sets, and similar structure measures were derived. The means and standard deviations of the parameters over all slices were calculated and MR-derived measures were correlated with those derived from the microCT data sets using linear regression analyses. Structure measures were overestimated with MRI, for example, the mean App. BV/TV was 0.45 for MRI and 0.20 for microT, and the slope of the graph was 1.45. App. Tb.Th was overestimated by a factor of 1.9, whereas App. Tb.Sp was underestimated; Tb.N showed the smallest effect. Correlations between the individual parameters were excellent (App. BV/TV, r2 = 0.82; App. Tb.Sp, r2 = 0.84; App. Tb.N, r2 = 0.81), except for App.Tb.Th (r2 = 0.67). The results of this study show that trabecular bone structure measures may be obtained using 3T MR imaging. These measures, although higher than the standard of reference, show a highly significant correlation with true structure measures obtained by microCT.


Assuntos
Cabeça do Fêmur/patologia , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Calibragem , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/normas , Masculino , Miniaturização , Padrões de Referência , Tomografia Computadorizada por Raios X/normas