Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(1)2022 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-36616868

RESUMO

This paper reports on a compact, portable, and selective chemical sensor for hazardous vapors at trace levels, which is under development and validation within the EU project H2020 "RISEN". Starting from the prototype developed for a previous EU project, here, we implemented an updated two-stage purge and trap vapor pre-concentration system, a more compact MEMS- based fast gas-chromatographic separation module (Compact-GC), a new miniaturized quartz-enhanced photoacoustic spectroscopy (QEPAS) detector, and a new compact laser source. The system provides two-dimensional selectivity combining GC retention time and QEPAS spectral information and was specifically designed to be rugged, portable, suitable for on-site analysis of a crime scene, with accurate response in few minutes and in the presence of strong chemical background. The main upgrades of the sensor components and functional modules will be presented in detail, and test results with VOCs, simulants of hazardous chemical agents, and drug precursors will be reported and discussed.


Assuntos
Gases , Quartzo , Quartzo/química , Gases/análise , Análise Espectral/métodos
2.
Sensors (Basel) ; 20(1)2019 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-31878138

RESUMO

This paper reports on a portable selective chemical sensor for hazardous vapors at trace levels, which combines a two-stage purge and trap vapor pre-concentration system, a Micro-Electro-Mechanical-System (MEMS) based fast gas-chromatographic (FAST-GC) separation column and a miniaturized quartz-enhanced photoacoustic spectroscopy (QEPAS) detector. The integrated sensing system provides two-dimensional selectivity combining GC retention time and QEPAS spectral information, and was specifically designed to be rugged and suitable to be deployed on unmanned robotic ground vehicles. This is the first demonstration of a miniaturized QEPAS device used as spectroscopic detector downstream of a FAST-GC separation column, enabling real-world analyses in dirty environments with response time of a few minutes. The main modules of the GC/QEPAS sensor device will be described in detail together with the system integration, and successful test results will be reported and discussed.

3.
Sensors (Basel) ; 19(22)2019 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-31698861

RESUMO

Water availability is a major limiting factor in plant productivity and plays a key role in plant species distribution over a given area. New technologies, such as terahertz quantum cascade lasers (THz-QCLs) have proven to be non-invasive, effective, and accurate tools for measuring and monitoring leaf water content. This study explores the feasibility of using an advanced THz-QCL device for measuring the absolute leaf water content in Corylus avellana L., Laurus nobilis L., Ostrya carpinifolia Scop., Quercus ilex L., Quercus suber L., and Vitis vinifera L. (cv. Sangiovese). A recently proposed, simple spectroscopic technique was used, consisting in determining the transmission of the THz light beam through the leaf combined with a photographic measurement of the leaf area. A significant correlation was found between the product of the leaf optical depth (τ) and the leaf surface area (LA) with the leaf water mass (Mw) for all the studied species (Pearson's r test, p ≤ 0.05). In all cases, the best fit regression line, in the graphs of τLA as a function of Mw, displayed R2 values always greater than 0.85. The method proposed can be combined with water stress indices of plants in order to gain a better understanding of the leaf water management processes or to indirectly monitor the kinetics of leaf invasion by pathogenic bacteria, possibly leading to the development of specific models to study and fight them.


Assuntos
Folhas de Planta/metabolismo , Água/metabolismo , Secas
4.
Sensors (Basel) ; 19(11)2019 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-31185640

RESUMO

Marine environments are currently subject to strong ecological pressure due to local and global anthropic stressors, such as pollutants and atmospheric inputs, which also cause ocean acidification and warming. These strains can result in biogeochemical cycle variations, environmental pollution, and changes in benthic-pelagic coupling processes. Two new devices, the Amerigo Lander and the Automatic Benthic Chamber (CBA), have been developed to measure the fluxes of dissolved chemical species between sediment and the water column, to assess the biogeochemical cycle and benthic-pelagic coupling alterations due to human activities. The Amerigo Lander can operate in shallow as well as deep water (up to 6000 m), whereas the CBA has been developed for the continental shelf (up to 200 m). The lander can also be used to deploy a range of instruments on the seafloor, to study the benthic ecosystems. The two devices have successfully been tested in a variety of research tasks and environmental impact assessments in shallow and deep waters. Their measured flux data show good agreement and are also consistent with previous data.

5.
Talanta ; 191: 141-148, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-30262043

RESUMO

A micro-electro-mechanical system (MEMS) based pre-concentrator filled with a standard Tenax TA adsorbent as well as with a synthetic receptor designed to adsorb 3-hydroxy-3-methylhexanoic acid (3H3MHA), a particular metabolite only available from human beings, was adapted to a custom made ion mobility spectrometer with gas-chromatographic pre-separation (GC-IMS). This combination was compared to a traditional sample loop GC-IMS. The application of a pre-concentrator is highly beneficial for the GC-IMS as analysing technique. By variation of the adsorbed sample volume, the system can be adapted to changing sample concentration ranges easily, thus increasing sensitivity significantly. Detection limits of few hundred ppqV could be obtained in this work for eucalyptol and 3 human metabolites (benzaldehyde, 2-ethyl-1-hexanol and decanal) as exemplary analytes. Moreover, the appropriate choice of selective pre-concentration phases in the pre-concentrator enables an adaptation of sampling to the composition of the mixture. Relevant compounds in very low concentrations can be amplified by using specially designed cavitands while interfering substances could be suppressed. This was successfully demonstrated by detecting 3H3MHA, a compound exclusively available in human sweat, which can be used to locate trapped or hidden individuals.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Sistemas Microeletromecânicos/métodos , Calibragem , Caproatos/análise , Caproatos/química , Limite de Detecção
6.
Plant Methods ; 13: 51, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28638439

RESUMO

BACKGROUND: Plant water resource management is one of the main future challenges to fight recent climatic changes. The knowledge of the plant water content could be indispensable for water saving strategies. Terahertz spectroscopic techniques are particularly promising as a non-invasive tool for measuring leaf water content, thanks to the high predominance of the water contribution to the total leaf absorption. Terahertz quantum cascade lasers (THz QCL) are one of the most successful sources of THz radiation. RESULTS: Here we present a new method which improves the precision of THz techniques by combining a transmission measurement performed using a THz QCL source, with simple pictures of leaves taken by an optical camera. As a proof of principle, we performed transmission measurements on six plants of Vitis vinifera L. (cv "Colorino"). We found a linear law which relates the leaf water mass to the product between the leaf optical depth in the THz and the projected area. Results are in optimal agreement with the proposed law, which reproduces the experimental data with 95% accuracy. CONCLUSIONS: This method may overcome the issues related to intra-variety heterogeneities and retrieve the leaf water mass in a fast, simple, and non-invasive way. In the future this technique could highlight different behaviours in preserving the water status during drought stress.

7.
Light Sci Appl ; 6(10): e17054, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30167200

RESUMO

Resonators and the way they couple to external radiation rely on very different concepts if one considers devices belonging to the photonic and electronic worlds. The terahertz frequency range, however, provides intriguing possibilities for the development of hybrid technologies that merge ideas from both fields in novel functional designs. In this paper, we show that high-quality, subwavelength, whispering-gallery lasers can be combined to form a linear dipole antenna, which creates a very efficient, low-threshold laser emission in a collimated beam pattern. For this purpose, we employ a terahertz quantum-cascade active region patterned into two 19-µm-radius microdisks coupled by a suspended metallic bridge, which simultaneously acts as an inductive antenna and produces the dipole symmetry of the lasing mode. Continuous-wave vertical emission is demonstrated at approximately 3.5 THz in a very regular, low-divergence (±10°) beam, with a high slope efficiency of at least 160 mW A-1 and a mere 6 mA of threshold current, which is ensured by the ultra-small resonator size (VRES/λ3≈10-2). The extremely low power consumption and the superior beam brightness make this concept very promising for the development of miniaturized and portable THz sources to be used in the field for imaging and sensing applications as well as for exploring novel optomechanical intracavity effects.

8.
Sci Rep ; 6: 33354, 2016 09 20.
Artigo em Inglês | MEDLINE | ID: mdl-27646194

RESUMO

The three-dimensional tomographic reconstruction of a biological sample, namely collagen fibrils in human dermal tissue, was obtained from a set of projection-images acquired in the Scanning Electron Microscope. A tailored strategy for the transmission imaging mode was implemented in the microscope and proved effective in acquiring the projections needed for the tomographic reconstruction. Suitable projection alignment and Compressed Sensing formulation were used to overcome the limitations arising from the experimental acquisition strategy and to improve the reconstruction of the sample. The undetermined problem of structure reconstruction from a set of projections, limited in number and angular range, was indeed supported by exploiting the sparsity of the object projected in the electron microscopy images. In particular, the proposed system was able to preserve the reconstruction accuracy even in presence of a significant reduction of experimental projections.

9.
Sci Rep ; 6: 31489, 2016 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-27538586

RESUMO

We demonstrate the use of a compound optical cavity as linear displacement detector, by measuring the thermal motion of a silicon nitride suspended membrane acting as the external mirror of a near-infrared Littrow laser diode. Fluctuations in the laser optical power induced by the membrane vibrations are collected by a photodiode integrated within the laser, and then measured with a spectrum analyzer. The dynamics of the membrane driven by a piezoelectric actuator is investigated as a function of air pressure and actuator displacement in a homodyne configuration. The high Q-factor (~3.4 · 10(4) at 8.3 · 10(-3) mbar) of the fundamental mechanical mode at ~73 kHz guarantees a detection sensitivity high enough for direct measurement of thermal motion at room temperature (~87 pm RMS). The compound cavity system here introduced can be employed as a table-top, cost-effective linear displacement detector for cavity optomechanics. Furthermore, thanks to the strong optical nonlinearities of the laser compound cavity, these systems open new perspectives in the study of non-Markovian quantum properties at the mesoscale.


Assuntos
Lasers Semicondutores , Artefatos , Desenho de Equipamento , Modelos Teóricos , Pressão
10.
PLoS One ; 9(8): e105474, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25153993

RESUMO

Nanolithography techniques enable the fabrication of complex nanodevices that can be used for biosensing purposes. However, these devices are normally supported by a substrate and their use is limited to in vitro applications. Following a top-down procedure, we designed and fabricated composite inductance-capacitance (LC) nanoresonators that can be detached from their substrate and dispersed in water. The multimaterial composition of these resonators makes it possible to differentially functionalize different parts of the device to obtain stable aqueous suspensions and multi-sensing capabilities. For the first time, we demonstrate detection of these devices in an aqueous environment, and we show that they can be sensitized to their local environment and to chemical binding of specific molecular moieties. The possibility to optically probe the nanoresonator resonance in liquid dispersions paves the way to a variety of new applications, including injection into living organisms for in vivo sensing and imaging.


Assuntos
Nanoestruturas , Nanotecnologia , Água , Técnicas Biossensoriais/instrumentação , Técnicas Analíticas Microfluídicas
11.
Opt Express ; 20(20): 21924-31, 2012 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-23037342

RESUMO

We report on the implementation of a confocal microscopy system based on a 2.9 THz quantum cascade laser source. Lateral and axial resolutions better than 70 µm and 400 µm, respectively, are achieved, with a large contrast enhancement compared to the non-confocal arrangement. The capability of resolving overlapping objects lying on different longitudinal planes is also clearly demonstrated.


Assuntos
Microscopia Confocal/instrumentação , Imagem Terahertz/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Lab Chip ; 10(15): 1997-2000, 2010 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-20526514

RESUMO

Fully controlled liquid injection and flow in hydrophobic polydimethylsiloxane (PDMS) two-dimensional microchannel arrays based on on-chip integrated, low-voltage-driven micropumps are demonstrated. Our architecture exploits the surface-acoustic-wave (SAW) induced counterflow mechanism and the effect of nebulization anisotropies at crossing areas owing to lateral propagating SAWs. We show that by selectively exciting single or multiple SAWs, fluids can be drawn from their reservoirs and moved towards selected positions of a microchannel grid. Splitting of the main liquid flow is also demonstrated by exploiting multiple SAW beams. As a demonstrator, we show simultaneous filling of two orthogonal microchannels. The present results show that SAW micropumps are good candidates for truly integrated on-chip fluidic networks allowing liquid control in arbitrarily shaped two-dimensional microchannel arrays.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...