Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Pharm Pharm Sci ; 8(2): 340-7, 2005 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-16124946

RESUMO

PURPOSE: A sensitive, robust, and selective liquid chromatographic-tandem mass spectrometric method (LC-MS/MS) was developed and validated for paroxetine quantification in human EDTA plasma. METHODS: Sample preparation was based on liquid-liquid extraction using a mixture of ethyl acetate/hexane (50/50; v/v) to extract the drug and internal standard from plasma. Chromatography was performed on a C-18 analytical column and the retention times were 1.6 and 1.7 for paroxetine and fluoxetine (IS), respectively. The ionization was optimized using ESI(+) and selectivity was achieved by tandem mass spectrometric analysis using MRM functions, 330.0 --> 70.0 and 310 --> 43.9 for paroxetine and fluoxetine. RESULTS: Analytical curve ranged from 0.2 to 20.0 ng/mL. Inter-day precision and accuracy of the quality control (QC) samples were < 15% relative standard deviation (RSD). Analyte stability during sampling processing and storage were established. CONCLUSION: Validation results on linearity, specificity, accuracy, precision as well as application to the analysis of samples taken up to 120 h after oral administration of 20 mg of paroxetine in 28 healthy volunteers were found to be of good performance in bioequivalence study.


Assuntos
Química Farmacêutica/métodos , Paroxetina/sangue , Adolescente , Adulto , Cromatografia Líquida/métodos , Estudos Cross-Over , Humanos , Masculino , Espectrometria de Massas/métodos , Paroxetina/química
2.
J Mass Spectrom ; 40(9): 1197-202, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16127659

RESUMO

A simple, sensitive and specific liquid chromatography-tandem mass spectrometry method for the quantification of bromopride I in human plasma is presented. Sample preparation consisted of the addition of procainamide II as the internal standard, liquid-liquid extraction in alkaline conditions using hexane-ethyl acetate (1 : 1, v/v) as the extracting solvent, followed by centrifugation, evaporation of the solvent and sample reconstitution in acetonitrile. Both I and II (internal standard, IS) were analyzed using a C18 column and the mobile-phase acetonitrile-water (formic acid 0.1%). The eluted compounds were monitored using electrospray tandem mass spectrometry. The analyses were carried out by multiple reaction monitoring (MRM) using the parent-to-daughter combinations of m/z 344.20 > 271.00 and m/z 236.30 > 163.10. The areas of peaks from analyte and IS were used for quantification of I. The achieved limit of quantification was 1.0 ng/ml and the assay exhibited a linear dynamic range of 1-100.0 ng/ml and gave a correlation coefficient (r) of 0.995 or better. Validation results on linearity, specificity, accuracy, precision and stability, as well as application to the analysis of samples taken up to 24 h after oral administration of 10 mg of I in healthy volunteers demonstrated the applicability to bioequivalence studies.


Assuntos
Cromatografia Líquida de Alta Pressão , Antagonistas de Dopamina/sangue , Antagonistas de Dopamina/farmacocinética , Metoclopramida/análogos & derivados , Espectrometria de Massas por Ionização por Electrospray/métodos , Humanos , Metoclopramida/sangue , Metoclopramida/farmacocinética , Equivalência Terapêutica
3.
Anal Bioanal Chem ; 382(4): 1049-54, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15891869

RESUMO

A liquid chromatographic-tandem mass spectrometric method (LC-MS/MS) for quantifying amlodipine in human plasma was developed and validated. Sample preparation was based on liquid-liquid extraction using NaOH and a mixture of ethyl acetate/hexane (80/20; v/v). Chromatography was performed on a C-18 analytical column and the retention times were 1.9 and 3.0 min for amlodipine and nimodipine (internal standard), respectively. The ionization was optimized using ESI(+) and enhanced selectivity was achieved using tandem mass spectrometric analysis via two MRM functions, 409 --> 238 and 418 --> 343 for amlodipine and nimodipine. The calibration curve ranged from 0.2 to 20.0 ng/mL. The inter-day precision and accuracy and the relative standard deviation (RSD) were <15%. The analyte was shown to be stable over the time-scale of the whole procedure. The robustness of the method was demonstrated by the good reproducibility of the results obtained during the analysis of clinical samples.


Assuntos
Anlodipino/análise , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/instrumentação , Cromatografia Líquida/métodos , Humanos , Estrutura Molecular , Sensibilidade e Especificidade , Espectrometria de Massas em Tandem/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...