Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Rev. esp. med. nucl. imagen mol. (Ed. impr.) ; 35(5): 292-297, sept.-oct. 2016. ilus
Artigo em Inglês | IBECS | ID: ibc-155012

RESUMO

Purpose. To assess if combined fluorescence- and radio-guided occult lesion localization (hybrid ROLL) is feasible in patients scheduled for surgical resection of non-palpable 18F-FDG-avid lesions on PET/CT. Methods. Four patients with 18F-FDG-avid lesions on follow-up PET/CT that were not palpable during physical examination but were suspected to harbor metastasis were enrolled. Guided by ultrasound, the hybrid tracer indocyanine green (ICG)-99mTc-nanocolloid was injected centrally in the target lesion. SPECT/CT imaging was used to confirm tracer deposition. Intraoperatively, lesions were localized using a hand-held gamma ray detection probe, a portable gamma camera, and a fluorescence camera. After excision, the gamma camera was used to check the wound bed for residual activity. Results. A total of six 18F-FDG-avid lymph nodes were identified and scheduled for hybrid ROLL. Comparison of the PET/CT images with the acquired SPECT/CT after hybrid tracer injection confirmed accurate tracer deposition. No side effects were observed. Combined radio- and fluorescence-guidance enabled localization and excision of the target lesion in all patients. Five of the six excised lesions proved tumor-positive at histopathology. Conclusion. The hybrid ROLL approach appears to be feasible and can facilitate the intraoperative localization and excision of non-palpable lesions suspected to harbor tumor metastases. In addition to the initial radioguided detection, the fluorescence component of the hybrid tracer enables high-resolution intraoperative visualization of the target lesion. The procedure needs further evaluation in a larger cohort and wider range of malignancies to substantiate these preliminary findings (AU)


Objetivo. Comprobar si la localización de lesiones tumorales ocultas utilizando la detección combinada de fluorescencia y radioactividad (ROLL híbrido) es factible en pacientes con lesiones no palpables pero 18F-FDG-ávidas en la PET/TC. Métodos. El presente estudio concierne a 4 pacientes con sospecha de metástasis ocultas al haberse encontrado lesiones con captación de 18F-FDG en la PET/TC durante el seguimiento. Guiado por ecografía, se inyectó a todos los pacientes el trazador híbrido ICG-99mTc-nanocoloide, centralmente en la lesión diana. Tras la inyección se realizó SPECT/TC para confirmar la correcta administración del trazador. En el quirófano las lesiones fueron localizadas utilizando una sonda de detección gamma en combinación con una gammacámara portátil y una cámara de fluorescencia. Después de la resección, se utilizó la gammacámara para controlar la radioactividad residual en el sitio de la exéresis. Resultados. Se detectó y seleccionó un total de 6 lesiones 18F-FDG-ávidas en la PET/TC para el procedimiento ROLL híbrido. En todos los pacientes la comparación de la SPECT/TC con la PET/TC previa confirmó con precisión la correcta administración de ICG-99mTc-nanocoloide en la lesión. Todas las lesiones diana fueron correctamente localizadas durante la intervención quirúrgica gracias a la detección radioguiada combinada con la imagen de fluorescencia. Cinco de las 6 lesiones extraídas resultaron metástasicas en la histopatología. Conclusión. El procedimiento híbrido de ROLL es factible y puede posibilitar intraoperatoriamente la localización y exéresis de lesiones no palpables con alta sospecha de albergar metástasis. Como complemento de la detección radioguiada el componente de fluorescencia del trazador híbrido permite la visualización con alta resolución de las lesiones durante la intervención quirúrgica. Se hace necesaria la validación del procedimiento de ROLL híbrido en una serie mayor de pacientes con lesiones clínicamente ocultas (AU)


Assuntos
Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Fluordesoxiglucose F18/análise , Traçadores Radioativos , Verde de Indocianina/administração & dosagem , Verde de Indocianina/análise , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Metástase Neoplásica , Metástase Neoplásica/diagnóstico , Metástase Neoplásica/patologia , Neoplasia Residual
2.
Rev. esp. med. nucl. imagen mol. (Ed. impr.) ; 32(4): 227-233, jul.-ago. 2013.
Artigo em Inglês | IBECS | ID: ibc-113487

RESUMO

Introducción. El verde de indocianina (ICG)-99mTc-nanocoloide es un novedoso trazador híbrido radioactivo y fluorescente para la biopsia selectiva del ganglio centinela (BSGC). Nuestro objetivo fue demostrar el valor añadido de este trazador en una serie de pacientes con diferentes neoplasias. Material y métodos. Se incluyeron consecutivamente 20 pacientes (con carcinoma de pene, cavidad oral y melanoma) entre marzo y mayo de 2012. A todos se les realizó una gammagrafía planar a los 15 y 120 min tras la inyección de ICG-99mTc-nanocoloide y posteriormente un SPECT/TAC. En quirófano se inyectó 1 ml de colorante vital (blue dye) a 14 pacientes. Durante la cirugía, los ganglios centinelas (GC) fueron localizados utilizando la sonda gammadetectora y visualizados por fluorescencia y colorante vital. Finalmente, se confirmó la extirpación completa de los GC con la gammacámara portátil. Resultados. Mediante una SPECT/TAC se identificó al menos un GC por paciente. Todos los GC (total: 68, 100%) fueron extirpados utilizando la combinación de guía radiofluorescente: 89,7% se localizaron con la sonda gammadetectora. Los ganglios restantes, situados cerca del punto de inyección, fueron ubicados por fluorescencia. Durante la cirugía, un 97% del total de GC fueron fluorescentes y solo el 39,2% azules. ex-vivo, todos los GC fueron radioactivos y fluorescentes. En 5 pacientes el GC fue metastásico. Conclusión. Aplicar una guía radiofluorescente para la BSGC es posible utilizando el ICG-99mTc-nanocoloide. Este enfoque híbrido combina los beneficios de ambas modalidades. La imagen fluorescente mejora la detección visual del GC respecto al colorante vital y demuestra ser especialmente útil cuando el GC está cerca del punto de inyección(AU)


Introduction. Indocyanine green (ICG)-99mTc-nanocolloid is a novel hybrid fluorescent radioactive tracer for sentinel node (SN) biopsy. This study has aimed to evaluate the added value of this novel versatile tracer in a series of patients with different malignancies. Material and methods. Twenty patients (with penile carcinoma, oral cavity tumors, melanoma) were consecutively included between March–May 2012. Planar lymphoscintigraphy was performed 15 min and 2 h after injection of ICG-99mTc-nanocolloid followed by SPECT/CT. Blue dye (1 ml) was injected in 14 patients in surgery room. Intraoperatively, SNs were localized using a gamma probe and visualized by optical SN-detection using blue dye and fluorescence imaging. Finally, a portable gamma camera was used to confirm complete SN removal. Results. At least one SN was identified by SPECT/CT in all patients. All SNs (total 68, 100%) were excised using a combination of radio- and fluorescence guidance: 89.7% were intraoperatively localized with the gamma probe. The remaining SNs, located near the injection site, were localized using fluorescence imaging. During the surgery, 97% of the SNs were fluorescent while only 39.2% were stained blue. Ex vivo, all SNs were both radioactive and fluorescent. The SN was positive in 5 patients. Conclusion. Synchronous radio- and fluorescence guided SN biopsy is feasible using ICG-99mTc-nanocolloid. This hybrid approach combines the beneficial properties of both modalities. Adding fluorescence imaging improves optical SN detection compared to blue dye. It has been shown to be especially useful in the localization of SNs near the injection site(AU)


Assuntos
Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Traçadores Radioativos , Verde de Indocianina , Tecnécio , Biópsia de Linfonodo Sentinela , Fluorescência , Espectrometria de Fluorescência/tendências , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Neoplasias Penianas/diagnóstico , Neoplasias Penianas , Pênis/patologia , Pênis , /métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...