Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Med Ultrasound ; 29(3): 157-166, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34729323

RESUMO

Ultrasound imaging systems need tissue-mimicking phantoms with a good range of acoustic properties. Many studies on carotid artery phantoms have been carried out using ultrasound; hence this study presents a review of the different forms of carotid artery phantoms used to examine blood hemodynamics by Doppler ultrasound (DU) methods and explains the ingredients that constitute every phantom with their advantages and disadvantages. Different research databases were consulted to access relevant information on carotid artery phantoms used for DU measurements after which the information were presented systematically spanning from walled phantoms to wall-less phantoms. This review points out the fact that carotid artery phantoms are made up of tissue mimicking materials, vessel mimicking materials, and blood mimicking fluid whose properties matched those of real human tissues and vessels. These materials are a combination of substances such as water, gelatin, glycerol, scatterers, and other powders in their right proportions.

2.
J Ultrason ; 21(86): e219-e224, 2021 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-34540276

RESUMO

Aim of the study: At present, there are few scatter particles used in preparing blood-mimicking fluids, such as nylon, sephadex, polystyrene microsphere, and poly(4-methystyrene). In this study, we present cholesterol as a new scatter particle for blood-mimicking fluid preparation. Materials and methods: The procedure for the preparation of the proposed blood-mimicking fluid involved the use of propylene glycol, D(+)-Glucose and distilled water to form a ternary mixture fluid, with cholesterol used as scatter particles. Polyethylene glycol was first used as part of the mixture fluid but the acoustic and physical properties were not suitable, leading to its replacement with D(+)-Glucose, which is soluble in water and has a higher density. A common carotid artery wall-less phantom was also produced to assess the flow properties. Results: The prepared blood-mimicking fluid with new scatter particles has a density of 1.067 g/cm3, viscosity of 4.1 mPa.s, speed of sound 1600 m/s, and attenuation of 0.192 dB/cm at 5 MHz frequency. Peak systolic velocity, end diastolic velocity and mean velocity measurements were gotten to be 40.2 ± 2.4 cm/s, 9.9 ± 1.4 cm/s, and 24.0 ± 1.8 cm/s, respectively. Conclusion: Based on the results obtained, the blood-mimicking fluid was found suitable for ultrasound applications in carotid artery wall-less phantoms because of its good acoustic and physical properties.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA