1.
Neuroimage ; 80: 220-33, 2013 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-23707579

RESUMO

Perhaps more than any other "-omics" endeavor, the accuracy and level of detail obtained from mapping the major connection pathways in the living human brain with diffusion MRI depend on the capabilities of the imaging technology used. The current tools are remarkable; allowing the formation of an "image" of the water diffusion probability distribution in regions of complex crossing fibers at each of half a million voxels in the brain. Nonetheless our ability to map the connection pathways is limited by the image sensitivity and resolution, and also the contrast and resolution in encoding of the diffusion probability distribution. The goal of our Human Connectome Project (HCP) is to address these limiting factors by re-engineering the scanner from the ground up to optimize the high b-value, high angular resolution diffusion imaging needed for sensitive and accurate mapping of the brain's structural connections. Our efforts were directed based on the relative contributions of each scanner component. The gradient subsection was a major focus since gradient amplitude is central to determining the diffusion contrast, the amount of T2 signal loss, and the blurring of the water PDF over the course of the diffusion time. By implementing a novel 4-port drive geometry and optimizing size and linearity for the brain, we demonstrate a whole-body sized scanner with G(max) = 300 mT/m on each axis capable of the sustained duty cycle needed for diffusion imaging. The system is capable of slewing the gradient at a rate of 200 T/m/s as needed for the EPI image encoding. In order to enhance the efficiency of the diffusion sequence we implemented a FOV shifting approach to Simultaneous MultiSlice (SMS) EPI capable of unaliasing 3 slices excited simultaneously with a modest g-factor penalty allowing us to diffusion encode whole brain volumes with low TR and TE. Finally we combine the multi-slice approach with a compressive sampling reconstruction to sufficiently undersample q-space to achieve a DSI scan in less than 5 min. To augment this accelerated imaging approach we developed a 64-channel, tight-fitting brain array coil and show its performance benefit compared to a commercial 32-channel coil at all locations in the brain for these accelerated acquisitions. The technical challenges of developing the over-all system are discussed as well as results from SNR comparisons, ODF metrics and fiber tracking comparisons. The ultra-high gradients yielded substantial and immediate gains in the sensitivity through reduction of TE and improved signal detection and increased efficiency of the DSI or HARDI acquisition, accuracy and resolution of diffusion tractography, as defined by identification of known structure and fiber crossing.


Assuntos
Encéfalo/anatomia & histologia , Encéfalo/fisiologia , Conectoma/métodos , Imagem de Tensor de Difusão/métodos , Aumento da Imagem/métodos , Modelos Anatômicos , Modelos Neurológicos , Animais , Humanos , Rede Nervosa/anatomia & histologia , Rede Nervosa/fisiologia
2.
Magn Reson Imaging ; 19(7): 1025-30, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11595375

RESUMO

Currently, it is assumed that the pharmacokinetic properties of the first minutes of an I.V. MR contrast media bolus are similar to those of an i.v. iodinated contrast media bolus used in CT. Correct timing of an MRA examination is crucial for obtaining sufficient arterial contrast. This study sought to evaluate the temporal change of arterial signal intensity within 150 s after i.v. bolus injection of Gd-DTPA. Thirty consecutive patients (14 women/16 men; mean age: 51 +/- 11 years) were prospectively examined with a 1.0 Tesla clinical scanner. A single axial slice was acquired in 1.25 sec with manufacturer provided gradient echo sequence through the aorta at the level of the renal arteries. Investigation was started simultaneously to the application of contrast media (0.1 mmol/kg bodyweight Gd-DTPA at three different rates 2 mL/sec, 3 mL/sec and 4 mL/sec) and repeated for 2.5 min. An additional echo Doppler examination excluded patients with any cardiac disorders. Maximum signal (1300% increase compared to the basic value) in the aorta was achieved 20 +/- 6 sec after start of bolus injection. Then a plateau phase was maintained for the remaining investigation time (2.5 min). No significant difference was shown for different injection rates. After a bolus injection of Gd-DTPA the arterial contrast remains on a high level for at least 2 min. However, correct timing of the bolus arrival is still crucial to discriminate arteries and veins. An injection rate between 2 mL/sec and 4 mL/sec has no influence on early contrast media dynamics.


Assuntos
Meios de Contraste/farmacocinética , Gadolínio DTPA/farmacocinética , Imageamento por Ressonância Magnética , Aorta , Ecocardiografia , Feminino , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estatísticas não Paramétricas , Fatores de Tempo
3.
Vasa ; 30(1): 9-13, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11284097

RESUMO

BACKGROUND: Evaluation of the applicability of intravascular radiofrequency receiver coils by means of a pig in-vivo-experiment for the detection of vessel wall structures at 1.0 Tesla. MATERIALS AND METHODS: The intravascular receiver coil was constructed according to a well evaluated single-loop-design, which was mounted onto a balloon catheter for angioplasty. Under fluoroscopy control the balloon catheter was placed in the common carotid artery of a porcine. Images were obtained in a 1.0 Tesla clinical scanner using a fast-spin-echo-, a gradient-echo- and a high resolution spin-echo-sequence. Histological examinations were obtained to detect any vessel wall damage associated with the use of the receiver coil. RESULTS: High quality images with a resolution up to 0.16*0.12 mm2 could be acquired in aquisition times of about 5 minutes. Subtle intra- and extra-vascular structures such as the balloon, irregularities of the vessel wall or bordering structures could be visualized. The histological examination showed no vessel damage due to the application of the intravascular receiver coil. CONCLUSIONS: The application of intravascular receiver coils for the visualization of the vessel wall is feasible at 1.0 Tesla without histologically detectable trauma to the vessel wall.


Assuntos
Cateterismo Periférico/instrumentação , Endotélio Vascular/anatomia & histologia , Angiografia por Ressonância Magnética/instrumentação , Animais , Lesões das Artérias Carótidas , Artéria Carótida Primitiva/anatomia & histologia , Endotélio Vascular/lesões , Desenho de Equipamento , Aumento da Imagem/instrumentação , Suínos