Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Thorac Cardiovasc Surg ; 69(6): 557-563, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33045756

RESUMO

BACKGROUND: Postoperative pulmonary recovery after lobectomy has showed early benefits for the video-assisted thoracoscopic surgery and sparing open techniques over nonsparing techniques. Robotic-assisted procedures offer benefits in term of clinical outcomes, but their advantages on pulmonary recovery and quality of life have not yet been distinctly prospectively studied. METHODS: Eighty-six patients undergoing lobectomy over a period of 29 months were prospectively studied for their pulmonary function recovery and pain score level during the in-hospital stay and at 1, 2, and 6 months. Quality of life was evaluated at 2 and 6 months. Forty-five patients were operated by posterolateral limited thoracotomy and 41 patients by robotic approach. The postoperative analgesia protocol differed for the two groups, being lighter for the robotic group. RESULTS: The pulmonary tests were not significantly different during the in-hospital stay. At 1 month, the forced expiratory volume in 1 second, forced vital capacity, vital capacity, and maximal expiratory pressure were significantly better for the robotic group (p = 0.05, 0.04, 0.05, and 0.02, respectively). There was no significant difference left at 2 and 6 months. Pain intensity was equivalent during the in-hospital stay but was significantly lower for the robotic group at 1 month (p = 0.02). At 2 and 6 months, pain and quality of life were comparable. CONCLUSION: Robotic technique can offer similar pulmonary and pain recovery during the in-hospital stay with a lighter analgesia protocol. It clearly favors the early term recovery compared with the open limited technique. The objective and subjective functional recovery becomes equivalent at 2 and 6 months.


Assuntos
Pulmão/cirurgia , Pneumonectomia , Procedimentos Cirúrgicos Robóticos , Toracotomia , Idoso , Analgésicos/uso terapêutico , Feminino , Humanos , Pulmão/patologia , Pulmão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/etiologia , Pneumonectomia/efeitos adversos , Estudos Prospectivos , Qualidade de Vida , Recuperação de Função Fisiológica , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Toracotomia/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
2.
Strahlenther Onkol ; 194(6): 591-599, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29450589

RESUMO

PURPOSE: By increasing lung volume and decreasing respiration-induced tumour motion amplitude, administration of continuous positive airway pressure (CPAP) during stereotactic ablative radiotherapy (SABR) could allow for better sparing of the lungs and heart. In this study, we evaluated the effect of CPAP on lung volume, tumour motion amplitude and baseline shift, as well as the dosimetric impact of the strategy. METHODS: Twenty patients with lung tumours referred for SABR underwent 4D-computed tomography (CT) scans with and without CPAP (CPAP/noCPAP) at two timepoints (T0/T1). First, CPAP and noCPAP scans were compared for lung volume, tumour motion amplitude, and baseline shift. Next, CPAP and noCPAP treatment plans were computed and compared for lung dose parameters (mean lung dose (MLD), lung volume receiving 20 Gy (V20Gy), 13 Gy (V13Gy), and 5 Gy (V5Gy)) and mean heart dose (MHD). RESULTS: On average, CPAP increased lung volume by 8.0% (p < 0.001) and 6.3% (p < 0.001) at T0 and T1, respectively, but did not change tumour motion amplitude or baseline shift. As a result, CPAP administration led to an absolute decrease in MLD, lung V20Gy, V13Gy and V5Gy of 0.1 Gy (p = 0.1), 0.4% (p = 0.03), 0.5% (p = 0.04) and 0.5% (p = 0.2), respectively, while having no significant influence on MHD. CONCLUSIONS: In patients referred for SABR for lung tumours, CPAP increased lung volume without modifying tumour motion or baseline shift. As a result, CPAP allowed for a slight decrease in radiation dose to the lungs, which is unlikely to be clinically significant.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/métodos , Neoplasias Pulmonares/cirurgia , Radiocirurgia/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Medidas de Volume Pulmonar , Masculino , Pessoa de Meia-Idade , Movimentos dos Órgãos/fisiologia , Radiometria , Tomografia Computadorizada por Raios X
3.
Artif Organs ; 35(7): 682-90, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21615428

RESUMO

Exercise capacity is improved in patients supported with continuous flow rotary blood pumps (RP). The aim of this study was to investigate the mechanisms underlying this improvement. Ten patients implanted with a RP underwent cardiopulmonary exercise testing (CPET) at 6 months after surgery with hemodynamic and metabolic measurements (RP group). A group of 10 matched heart failure patients were extracted from our heart transplant database, and the results of their last CPET before transplantation were used for comparison (heart failure [HF] group). Peak VO(2) was significantly higher in RP than in HF patients (15.8 ± 6.2 vs. 10.9 ± 3 mL O(2)/kg.min) reaching 52 ± 16% of their predicted peak VO(2). The total output measured by a Swan-Ganz catheter increased from 5.6 ± 1.6 to 9.2 ± 1.8 L/min in the RP group and was significantly higher at rest and at peak exercise than in the HF group, whose output increased from 3.5 ± 0.4 to 5.6 ± 1.6 L/min. In the RP group, the estimated pump flow increased from 5.3 ± 0.4 to 6.2 ± 0.8, whereas the native cardiac output increased from 0.0 ± 0.5 to 3 ± 1.7 L/min. Cardiac output at peak exercise was inversely correlated with age (r = -0.86, P = 0.001) and mean pulmonary artery pressure (r = -0.75, P = 0.012). Maximal exercise capacity is improved in patients supported by RP as compared to matched HF patients and reaches about 50% of the expected values. Both a spontaneous increase of pump flow at constant pump speed and an increase of the native cardiac output contribute to total flow elevation. These findings may suggest that an automatic pump speed adaptation during exercise would further improve the exercise capacity. This hypothesis should be examined.


Assuntos
Débito Cardíaco , Exercício Físico , Coração Auxiliar , Coração/fisiologia , Adulto , Desenho de Equipamento , Teste de Esforço , Feminino , Coração/fisiopatologia , Insuficiência Cardíaca/fisiopatologia , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade
4.
Intensive Care Med ; 29(6): 949-954, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12664221

RESUMO

OBJECTIVE: To compare the respiratory muscle workload associated with pressure support ventilation (PSV) and proportional assist ventilation (PAV) in intubated and spontaneously breathing patients without COPD. DESIGN AND SETTING: Prospective study, intensive care unit university hospital. INTERVENTIONS: Twenty intubated patients, during early weaning, PSV settings made by clinician in charge of the patient, and two levels of PAV, set to counterbalance 80% (PAV 80) and 50% (PAV 50) of both elastic and resistive loads, respectively. The patients were ventilated in the following order: 1) PSV; 2) PAV 50 or PAV 80; 3) PSV; 4) PAV 80 or PAV 50; 5) PSV. PSV settings were kept constant. MEASUREMENTS: Arterial blood gases, breathing pattern and respiratory effort parameters at the end of each of the five steps. MAIN RESULTS: PSV and PAV 80 had the same effects on work of breathing (WOB). The pressure-time product (PTP) was significantly higher during PAV 80 than during PSV (90+/-76 and 61+/-56 cmH(2)O.s.min(-1), respectively, P <0.05). Tidal volume was comparable, albeit more variable with PAV 80 than with PSV (variation coefficient, 43% vs 25%, respectively, P <0.05). PAV 50 entailed a higher respiratory rate, lower tidal volume, and higher WOB and PTP than PSV and PAV 80. PaO(2)/FiO(2) and SaO(2) were lower with PAV 50 than with PSV and PAV 80. CONCLUSION: In a group of intubated spontaneously breathing non-COPD patients, PAV 80 and PSV were associated with comparable levels WOB, whereas PTP was higher during PAV 80. PAV 50 provided insufficient respiratory assistance.


Assuntos
Ventilação com Pressão Positiva Intermitente/métodos , Respiração com Pressão Positiva/métodos , Insuficiência Respiratória/terapia , Trabalho Respiratório , Adulto , Idoso , Idoso de 80 Anos ou mais , Resistência das Vias Respiratórias , Gasometria , Feminino , Fluxo Expiratório Forçado , Humanos , Complacência Pulmonar , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doença Pulmonar Obstrutiva Crônica/complicações , Troca Gasosa Pulmonar , Insuficiência Respiratória/complicações , Insuficiência Respiratória/metabolismo , Insuficiência Respiratória/fisiopatologia , Volume de Ventilação Pulmonar , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...