Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Biomater Appl ; 31(2): 230-40, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27358375

RESUMO

Recently, three-dimensional graphene interconnected network has attracted great interest as a scaffold structure for tissue engineering due to its high biocompatibility, high electrical conductivity, high specific surface area and high porosity. However, free-standing three-dimensional graphene exhibits poor flexibility and stability due to ease of disintegration during processing. In this work, three-dimensional graphene is composited with polydimethylsiloxane to improve the structural flexibility and stability by a new simple two-step process comprising dip coating of polydimethylsiloxane on chemical vapor deposited graphene/Ni foam and wet etching of nickel foam. Structural characterizations confirmed an interconnected three-dimensional multi-layer graphene structure with thin polydimethylsiloxane scaffold. The composite was employed as a substrate for culture of L929 fibroblast cells and its cytocompatibility was evaluated by cell viability (Alamar blue assay), reactive oxygen species production and vinculin immunofluorescence imaging. The result revealed that cell viability on three-dimensional graphene/polydimethylsiloxane composite increased with increasing culture time and was slightly different from a polystyrene substrate (control). Moreover, cells cultured on three-dimensional graphene/polydimethylsiloxane composite generated less ROS than the control at culture times of 3-6 h. The results of immunofluorescence staining demonstrated that fibroblast cells expressed adhesion protein (vinculin) and adhered well on three-dimensional graphene/polydimethylsiloxane surface. Good cell adhesion could be attributed to suitable surface properties of three-dimensional graphene/polydimethylsiloxane with moderate contact angle and small negative zeta potential in culture solution. The results of electrochemical study by cyclic voltammetry showed that an oxidation current signal with no apparent peak was induced by fibroblast cells and the oxidation current at an oxidation potential of +0.9 V increased linearly with increasing cell number. Therefore, the three-dimensional graphene/polydimethylsiloxane composite exhibits high cytocompatibility and can potentially be used as a conductive substrate for cell-based electrochemical sensing.


Assuntos
Materiais Biocompatíveis/química , Dimetilpolisiloxanos/química , Técnicas Eletroquímicas/métodos , Grafite/química , Alicerces Teciduais/química , Animais , Adesão Celular , Linhagem Celular , Fibroblastos/citologia , Camundongos , Níquel/química , Espécies Reativas de Oxigênio/química , Propriedades de Superfície
2.
Lab Chip ; 12(1): 133-8, 2012 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-22072313

RESUMO

Recently, we have demonstrated that DNA hybridization using acoustic streaming induced by two piezoelectric transducers provides higher DNA hybridization efficiency than the conventional method. In this work, we refine acoustic streaming system for DNA hybridization by inserting an additional piezoelectric transducer and redesigning the locations of the transducers. The Comsol® Multiphysics was used to design and simulate the velocity field generated by the piezoelectric agitation. The simulated velocity vector followed a spiral vortex flow field with an average direction outward from the center of the transducers. These vortices caused the lower signal intensity in the middle of the microarray for the two-piezoelectric disk design. On the contrary, the problem almost disappeared in the three-piezoelectric-disk system. The optimum condition for controlling the piezoelectric was obtained from the dye experiments with different activation settings for the transducers. The best setting was to activate the side disks and middle disk alternatively with 1 second activating time and 3 second non-activating time for both sets of transducers. DNA hybridization using microarrays for the malaria parasite Plasmodium falciparum from the optimized process yielded a three-fold enhancement of the signal compared to the conventional method. Moreover, a greater number of spots passed quality control in the optimized device, which could greatly improve biological interpretation of DNA hybridization data.


Assuntos
Acústica/instrumentação , Hibridização de Ácido Nucleico/métodos , Análise de Sequência com Séries de Oligonucleotídeos/instrumentação , Transdutores , Carbocianinas/química , Sondas de DNA , DNA de Protozoário/química , DNA de Protozoário/genética , Análise de Elementos Finitos , Modelos Moleculares , Análise de Sequência com Séries de Oligonucleotídeos/métodos , Plasmodium falciparum/genética , Processamento de Sinais Assistido por Computador
3.
Lab Chip ; 11(6): 1059-64, 2011 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-21290049

RESUMO

In conventional DNA microarray hybridization, delivery of target cDNAs to surface-bounded probes depends solely on diffusion, which is notoriously slow, and thus typically requires 6-20 h to complete. In this study, piezoelectric microagitation through a liquid coupling medium is employed to enhance DNA hybridization efficiency and the results are compared with the standard static hybridization method. DNA hybridization was performed in a sealed aluminium chamber containing DNA microarray glass chip, coupling medium and piezoelectric transducers. 3×SSC (Saline Sodium Citrate) was used as a coupling medium to prevent overheating of the piezoelectric transducers and to effectively transmit ultrasonic wave to the glass chip. Flow visualization using fluidic dye and velocimetry (PTV) technique was applied to observe fluid transport in the hybridization chamber. It was revealed that the dye solution was homogeneously distributed within 10 min under dynamic agitation while it took over 1 h to reach the same level of homogeneity in static condition. Plasmodium falciparum DNA microarrays and total RNA extracted from parasite cells were used as a model for DNA microarray experiments. It was found that the required hybridization time may be substantially reduced from 16 h to 4 h by the use of dynamic hybridization scheme. With the same hybridization time of 16 h, dynamic hybridization resulted in higher fluorescent signals of ∼33% and ∼24% compared to static hybridization in Cy3 and Cy5 channels, respectively. Additionally, good/effective spots, some of which were not formed by static method, were enhanced and distributed more uniformly over the microarray. Therefore, the developed dynamic hybridization with integrated piezoelectric microagitation platform is highly promising for DNA analysis in molecular biology and medical applications.


Assuntos
DNA Complementar/análise , Análise de Sequência com Séries de Oligonucleotídeos/métodos , Corantes Fluorescentes/química , Análise de Sequência com Séries de Oligonucleotídeos/instrumentação , Plasmodium falciparum/genética , RNA/metabolismo
4.
Talanta ; 79(4): 995-1000, 2009 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-19615498

RESUMO

A microfabicated flow injection device has been developed for in-channel electrochemical detection (ECD) of a beta-agonist, namely salbutamol. The microfluidic system consists of PDMS (polydimethylsiloxane) microchannel and electrochemical electrodes formed on glass substrate. The carbon nanotube (CNT) on gold layer as working electrode, silver as reference electrode and platinum as auxiliary electrode were deposited on a glass substrate. Silver, platinum, gold and stainless steel catalyst layers were coated by DC-sputtering. CNTs were then grown on the glass substance by thermal chemical vapor deposition (CVD) with gravity effect and water-assisted etching. 100-microm-deep and 500-microm-wide PDMS microchannels fabricated by SU-8 molding and casting were then bonded on glass substrate by oxygen plasma treatment. Flow injection and ECD of salbutamol was performed with the amperometric detection mode for in-channel detection of salbutamol. The influences of flow rate, injection volume, and detection potential on the response of current signal were optimized. Analytical characteristics, such as sensitivity, repeatability and dynamic range have been evaluated. Fast and highly sensitive detection of salbutamol have been achieved. Thus, the proposed combination of the efficient CNT electrode and miniaturized lab-on-a-chip is a powerful platform for beta-agonists detection.


Assuntos
Agonistas Adrenérgicos beta/análise , Albuterol/análise , Análise de Injeção de Fluxo/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Nanotubos de Carbono/química , Dimetilpolisiloxanos/química , Eletroquímica , Eletrodos , Análise de Injeção de Fluxo/métodos , Vidro/química , Técnicas Analíticas Microfluídicas/métodos , Reprodutibilidade dos Testes , Fatores de Tempo , Volatilização
5.
Anal Chim Acta ; 647(1): 78-83, 2009 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-19576389

RESUMO

A simple, low cost and portable microfluidic system based on a two-point alkaline picrate kinetic reaction has been developed for the determination of urinary creatinine. The creatinine reacts with picric acid under alkaline conditions, forming an orange-red colour, which is monitored on PDMS microchip using a portable miniature fibre optic spectrometer at 510 nm. A linear range was displayed from 0 to 40 mg L(-1) creatinine (r2 = 0.997) with a detection limit of 3.3 mg L(-1) (S/N = 3). On-chip absorbance signals are reproducible, with relative standard deviations (RSDs) of 7.1%, when evaluated with 20 mg L(-1) creatinine (n = 10). The standard curves in which the intra-run CVs (4.7-6.8%) and inter-run CVs (7.9%) obtained were performed on three different days and exhibited good reproducibility. The method was highly correlated with the conventional spectrophotometric method when real urine samples were evaluated (r2 = 0.948; n = 15).


Assuntos
Creatinina/urina , Microfluídica/instrumentação , Microfluídica/métodos , Concentração de Íons de Hidrogênio , Picratos/química , Reprodutibilidade dos Testes , Temperatura , Fatores de Tempo
6.
Sensors (Basel) ; 9(12): 10066-79, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-22303162

RESUMO

An immunoassay performed on a portable microfluidic device was evaluated for the determination of urinary albumin. An increase in absorbance at 500 nm resulting from immunoagglutination was monitored directly on the poly(dimethylsiloxane) (PDMS) microchip using a portable miniature fibre-optic spectrometer. A calibration curve was linear up to 10 mg L(-1) (r(2) = 0.993), with a detection limit of 0.81 mg L(-1) (S/N = 3). The proposed system showed good precision, with relative standard deviations (RSDs) of 5.1%, when evaluated with 10 mg L(-1) albumin (n = 10). Determination of urinary albumin with the proposed system gave results highly similar to those determined by the conventional spectrophotometric method using immunoturbidimetric detection (r(2) = 0.995; n = 15).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...