Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Mol Ther Methods Clin Dev ; 32(1): 101163, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38178915

RESUMO

Rupture or dissection of thoracic aortic aneurysms is still the leading cause of death for patients diagnosed with Marfan syndrome. Inflammation and matrix digestion regulated by matrix metalloproteases (MMPs) play a major role in the pathological remodeling of the aortic media. Regnase-1 is an endoribonuclease shown to cleave the mRNA of proinflammatory cytokines, such as interleukin-6. Considering the major anti-inflammatory effects of regnase-1, here, we aimed to determine whether adeno-associated virus (AAV)-mediated vascular overexpression of the protein could provide protection from the development and progression of aortic aneurysms in Marfan syndrome. The overexpression of regnase-1 resulted in a marked decrease in inflammatory parameters and elastin degradation in aortic smooth muscle cells in vitro. Intravenous injection of a vascular-targeted AAV vector resulted in the efficient transduction of the aortic wall and overexpression of regnase-1 in a murine model of Marfan syndrome, associated with lower circulating levels of proinflammatory cytokines and decreased MMP expression and activity. Regnase-1 overexpression strongly improved elastin architecture in the media and reduced aortic diameter at distinct locations. Therefore, AAV-mediated regnase-1 overexpression may represent a novel gene therapy approach for inhibiting aortic aneurysms in Marfan syndrome.

2.
PLoS One ; 18(9): e0291335, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37708150

RESUMO

BACKGROUND: In pediatric orthopedics, long bone lengthening procedures are routinely performed using manual, motorized or magnetically controlled implants. This study aims to prove expansion of a newly designed osmotic pump prior to long bone lengthening in living organisms and to rule out any complications related to in vivo conditions, such as congestion of the semipermeable membrane, local infection, or lack of water to drive the osmotic pump, as well as to compare in vivo and in vitro expansion data. METHODS: Osmotic pumps, which were designed to distract a plate osteosynthesis, were inserted in the dorsal paraspinal musculature of four piglets. To compare the performance of the pumps in in vivo and in vitro conditions, another set of pumps was submerged in physiologic saline solution at different temperatures. The lengthening progress was measured radiographically and sonographically in the study animals. RESULTS: Both, in vitro and in vivo tested osmotic pumps started distraction after an intended rest phase of four days and distracted evenly over the following twelve days. No complications, clogging or damages occurred. However, we observed a temperature dependency of the distraction rate ranging from 0.98 mm/day at 39°C to 1.10 mm/day at 42°C. With a second setup, we confirmed that the distraction rate differed by 72% within a measured temperature interval of 14° C. CONCLUSIONS: The data presented here confirm that the novel osmotic pump showed comparable lengthening characteristics in vivo and in vitro. No complications, such as congestion of the semipermeable membrane, local infection, or lack of water to drive the osmotic pump were observed. Thus, osmotic pumps may have great potential in future applications such as long bone lengthening procedures, where continuous distraction probably provides a better bone quality than intermittent lengthening procedures. The fact that one pump failed to elongate in each condition, highlights the importance of technical improvement, but also demonstrates that this was not due to different circumstances within the in vivo or in vitro condition.


Assuntos
Alongamento Ósseo , Ortopedia , Animais , Suínos , Osmose , Placas Ósseas , Água
3.
J Vis Exp ; (188)2022 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-36282705

RESUMO

Aortic banding in mice is one of the most commonly used experimental models for cardiac pressure overload-induced cardiac hypertrophy and the induction of heart failure. The previously used technique is based on a threaded suture around the aortic arch tied over a blunted 27 G needle to create stenosis. This method depends on the surgeon manually tightening the thread and, thus, leads to high variance in the diameter size. A newly refined method described by Melleby et al. promises less variance and more reproducibility after surgery. The new technique, o-ring- aortic banding (ORAB), uses a non-slip rubber ring instead of a suture with a thread, resulting in reduced variation in pressure overload and reproducible phenotypes of cardiac hypertrophy. During surgery, the o-ring is placed between the brachiocephalic and left carotid arteries. Successful constriction is confirmed by echocardiography. After 1 day, correct placement of the ring results in an increased flow velocity in the transverse aorta over the o-ring-induced stenosis. After 2 weeks, impaired cardiac function is proven by decreased ejection fraction and increased wall thickness. Importantly, besides less variance in the diameter size, ORAB is associated with lower intra- and post-operative mortality rates compared with transverse aortic constriction (TAC). Thus, ORAB represents a superior method to the commonly used TAC surgery, resulting in more reproducible results and a possible reduction in the number of animals needed.


Assuntos
Estenose da Valva Aórtica , Borracha , Camundongos , Animais , Camundongos Endogâmicos C57BL , Constrição , Constrição Patológica/etiologia , Constrição Patológica/cirurgia , Reprodutibilidade dos Testes , Modelos Animais de Doenças , Cardiomegalia/diagnóstico por imagem , Cardiomegalia/etiologia , Aorta/diagnóstico por imagem , Aorta/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...