Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Exp Dermatol ; 27(3): 233-237, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29278440

RESUMO

Pemphigus vulgaris (PV) is a severe autoimmune blistering disease of the skin and mucous membranes. As autoantibodies play an essential role in the disease pathogenesis, the serological detection of anti-desmoglein 3 IgG represents a central tool in the diagnosis of the disease. In this study, we show the validation of a novel lateral flow immunoassay (LFIA) which rapidly detects anti-desmoglein 3 (Dsg3) IgG in human serum. In contrast to other diagnostic procedures, the assay is compact and simple to perform and delivers a fast "yes" or "no" answer within 10 minutes without additional hardware requirements for test evaluation. For validation, a blinded collection of 200 sera including 100 sera from 14 PV patients, 75 sera from 24 bullous pemphigoid patients and 25 sera from 6 patients with pemphigus foliaceus collected at different time points during disease was used. Presence or non-presence of anti-Dsg3 IgG within sera was confirmed using a commercially available Dsg3-ELISA. For qualitative evaluation, Dsg3-LFIA test results were assessed by two independent groups of human observers. Furthermore, quantitative evaluation using POCScan reader was applied. The Dsg3-LFIA demonstrated reliable test results with a sensitivity and specificity of 78.1% and 97.1%, respectively. Test results from POCScan and human observers showed a substantial agreement. The Dsg3-LFIA represents a new diagnostic tool for the immediate and reliable detection of anti-desmoglein 3 serum IgG autoantibodies that does not require additional hardware. Further prospective trials are warranted to validate the Dsg3 LFIA in pemphigus.


Assuntos
Autoanticorpos/sangue , Desmogleína 3/imunologia , Imunoensaio/métodos , Imunoglobulina G/sangue , Pênfigo/sangue , Pênfigo/diagnóstico , Humanos , Penfigoide Bolhoso/sangue , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Método Simples-Cego , Fatores de Tempo
2.
Clin Chem Lab Med ; 49(12): 2065-8, 2011 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-21875394

RESUMO

BACKGROUND: The exclusion of heparin induced thrombocytopenia (HIT) is required for selecting the most appropriate anticoagulation therapy in affected patients. It requires the combination of clinical data with the detection of antibodies directed against platelet factor 4 (PF4) in complex with polyanions (PA) such as heparin. METHODS: We developed a lateral flow immunoassay (LFIA) for PF4/PA complex specific IgG antibodies based on gold nanoparticles. Unlike most other assays, the initial immune reaction takes place in the liquid phase. The sensitivity of the assay has been adjusted with clinical samples aiming in the reliable detection of sera which are positive in a functional platelet activation assay. RESULTS: Sera from 60 patients with suspected HIT were investigated. LFIA identified correctly all samples (n=20) which were positive in a functional assay (HIPA) and an IgG specific ELISA. It correlated with ELISA, but false positive results were less frequent (7 samples were negative with LFIA and HIPA but positive with ELISA). CONCLUSIONS: The LFIA may be a suitable tool for the rapid exclusion of HIT within 10 min.


Assuntos
Heparina/efeitos adversos , Imunoensaio , Imunoglobulina G/sangue , Trombocitopenia/sangue , Ouro/química , Humanos , Nanopartículas Metálicas/química , Fator Plaquetário 4/imunologia , Trombocitopenia/induzido quimicamente , Trombocitopenia/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...