Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Dent J (Basel) ; 11(10)2023 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-37886913

RESUMO

Chlorhexidine digluconate (CHX) has shown the ability to significantly reduce inflammation and marginal bone loss (MBL) at the 1-year follow-up but limited data exist regarding its long-term efficacy in peri-implant stability. The objective was to compare the long-term effects (5 years of follow-up) of a placebo gel (16 patients in Group A) or a 0.20% CHX gel (15 patients in Group B) used at each previous surgical and prosthetic stage. Control visits were conducted in 2022, investigating the long-term effects by biological, radiological, and clinical evaluation. The data were statistically analyzed. The research achieved a 96.7% implant success rate over five years, but 41.9% of patients did not attend annual oral hygiene check-ups. The average MBL was 1.04 ± 0.39 mm, with no significant differences between the two groups. Notably, patients who attended regular periodontal check-ups experienced significantly less MBL than those who did not (p < 0.05). At five years, direct effects of CHX were absent, with both groups showing moderate bone loss. However, the results suggest that early disinfection could enhance both short- and long-term outcomes. In fact, patients with initial minor MBL due to use of CHX, preserve this advantage also after 5 years of follow-up. Additionally, the data underscore the importance of annual check-ups in early detection and management of biological complications.

2.
Antibiotics (Basel) ; 11(5)2022 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-35625302

RESUMO

BACKGROUND: The purpose of the present case report was to investigate a very rare ectopic third molar removal by a trans-sinusal approach and report the study findings through a systematic review of the literature on this topic. CASE PRESENTATION: A 38-year-old female patient was visited for pain at the level of the right maxillary region. No relevant medical history was reported. The CBCT tomography assessment revealed an impacted third tooth at the level of the postero-lateral maxilla. REVIEW METHODS: An electronic search was performed through Boolean indicators query on Pubmed/Medline, EMBASE, Cochrane Library databases. The clinical reports were identified and selected in order to perform a descriptive analysis. The surgical approach concerned a trans-sinusal access to the site for the ectopic tooth removal with a lateral antrostomy. No evident inflammatory alteration was associated to the ectopic tooth and a non-relevant post-operative sequelae was reported at the follow up. RESULTS: A total of 34 scientific papers were retrieved from the database search. Only two cases reported a wait-and-see radiographical follow-up approach, while the most common treatment was surgical removal, also for asymptomatic cases. CONCLUSION: The third-molar ectopic tooth into the maxillary sinus is an uncommon occurrence that is beast treated by an in-chair intraoral tran-sinusal approach, with a consistent reduction of the invasivity, a mild morbidity and a successful functional outcome.

3.
J Dent ; 119: 104054, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35122936

RESUMO

OBJECTIVES: The objective of this study was to define the impact of heating rate on the crystal growth, the mechanical properties, and the biocompatibility of three different kinds of CAD/CAM glass-ceramics treated with a conventional furnace. METHODS: Lithium disilicate (IPS EMax-CAD, Ivoclar Vivadent) (LS2) and two zirconia reinforced lithium silicate (ZLS) ceramics (Vita Suprinity PC, VITA Zahnfabrik; Celtra Duo, Dentsply Sirona) (ZLSS; ZLSC) were used. The mechanical properties and the crystal growth were evaluated on 42 specimens (n = 14 per group). The thermal treatments recommended by the manufacturers were carried out. All groups were tested for fracture toughness (Ft) and Vickers hardness (Hv). Scanning electron microscope (SEM) images were taken after a slight surface etching with hydrofluoric acid solution (1% for 20 s). Differential Thermal Analysis (DTA) was performed and cellular adhesion with human periodontal ligament stem cells (hPDLSCs) culture was qualitatively assayed. Data were analyzed with Repeated Measurements ANOVA and ANOVA followed by Tukey post hoc test. RESULTS: The crystals' mean size (±SD) after heat treatment was 1650.0 (±340.0) nm for LS2, 854.5 (±155.0) nm for ZLSS and 759.9 (±118.4) nm for ZLSC (p < 0.05 among the groups). As consequence of crystallization, the Hv was 6.1 ± 0.3 GPa for LS2, 7.6 ± 0.7 GPa for ZLSS and 7.1 ± 0.5 GPa for ZLSC (p < 0.05 for LS2 vs ZLSS and ZLSC), while the Ft was 2.2 ± 0.1 MPa m1/2 for LS2, 4.7 ± 0.8 MPa m1/2 for ZLSS and 3.8 ± 0.6 MPa m1/2 for ZLSC (p < 0.05 among the groups). The DTA curves showed a crystallization process for LS2, ZLSS and ZLSC at a temperature range 810-840 °C. The amount of adherent hPDLSCs was superior on LS2 than on ZLS. CONCLUSIONS: All the CAD/CAM materials can be properly crystallized if heat treated following the manufacturers' instructions. The crystallization process highly depends on temperature. ZLS glass ceramics show significantly inferior crystals dimensions and higher fracture toughness and Vickers hardness than LS2 ceramic. hPDLSCs cultured on LS2 have a superior adhesion than those cultured on ZLS. CLINICAL SIGNIFICANCE: The value of this study relies on the demonstration that a proper heat-treatment of CAD/CAM lithium disilicate and ZLS glass ceramics generates products that are suitable for clinical use . The differences highlightable in mechanical properties and biocompatibility behavior do not affect their successful clinical application.


Assuntos
Porcelana Dentária , Lítio , Cerâmica/química , Desenho Assistido por Computador , Cristalização , Porcelana Dentária/química , Humanos , Teste de Materiais , Silicatos , Propriedades de Superfície , Zircônio/química
4.
Materials (Basel) ; 14(17)2021 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-34501060

RESUMO

The purposes of this study were to evaluate the efficacy of water-airborne-particle abrasion (WAPA) as pre-etching procedure for tooth surfaces to increase bond strength, and to compare the survival rate of WAPA vs. non-WAPA glass-ceramic restorations with a 15-year follow-up. The occlusal surfaces of 20 human molars were sectioned and flattened. The prepared surfaces areas were subdivided into two parts: one received WAPA treatment (prophy jet handpiece with 50 µm aluminium oxide particles) followed by acid etching (37% phosphoric acid for 20 s/3-step etch-and-rinse); the other one was only acid-etched. In total, 108 specimens were obtained from the teeth, of which 80 were used to measure the micro-tensile bond strength (µTBS) in the WAPA (n = 40) and control (n = 40) groups, while the remaining specimens (n = 28) were investigated via SEM to evaluate the micromorphology and roughness (Ra) before and after the different treatment steps. The survival rate (SR) was performed on 465 glass-ceramic restorations (131 patients) comparing WAPA treatment (n = 183) versus non-WAPA treatment (n = 282). The bond strength was 63.9 ± 7.7 MPa for the WAPA group and 51.7 ± 10.8 MPa for the control group (p < 0.001). The Ra was 98 ± 24 µm for the enamel control group, 150 ± 35 µm for the enamel WAPA group, 102 ± 27 µm for the dentin control group and 160 ± 25 µm for the dentin WAPA group. The Ra increase from the WAPA procedure for enamel and dentin was statistically significant (p < 0.05). Under SEM, resin tags were present in both groups although in the WAPA they appeared to be extended in a 3D arrangement. The SR of the WAPA group (11.4 years) was 94%, while the SR of the non-WAPA group (12.3 years) was 87.6% (p < 0.05). The WAPA treatment using aluminium oxide particles followed by a 3-step etch-and-rinse adhesive system significantly improved bioadhesion with an increased bond strength of 23.6% and provided superior long-term clinical performance of glass-ceramic restorations.

5.
BMC Ophthalmol ; 21(1): 121, 2021 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-33676433

RESUMO

BACKGROUND: Zygomatic implants have been proposed in literature for atrophic maxillary fixed oral rehabilitations. The aim of the present research was to evaluate, by a clinical and tomography assessment, a surgical complication of a zygomatic implant penetration to the orbit. CASE PRESENTATION: A 56 year-old female patient was visited for pain and swelling in the left orbit after a zygomatic implant protocol. The orbit invasion of the zygomatic implant screw was confirmed by the CBCT scan. The patient was treated for surgical implant removal and the peri- and post-operative symptoms were assessed. No neurological complications were reported at the follow-up. The ocular motility and the visual acuity were well maintained. No purulent secretion or inflammatory evidence were reported in the post-operative healing phases. CONCLUSION: The penetration of the orbit during a zygomatic implant positioning is a surgical complication that could compromise the sight and movements of the eye. In the present case report, a zygomatic implant removal resulted in an uneventful healing phase with recovery of the eye functions.


Assuntos
Arcada Edêntula , Órbita , Feminino , Seguimentos , Humanos , Maxila , Pessoa de Meia-Idade , Zigoma/diagnóstico por imagem , Zigoma/cirurgia
6.
Materials (Basel) ; 13(1)2020 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-31948123

RESUMO

To date, numerous materials in the dental field are marketed to ensure stable adhesive cementation of zirconia ceramics (Y-TZP). The aims of this study were to assess the shear bond strength of the new experimental cement Surgi Dual Flo' Zr to Y-TZP compared to Panavia V5 cement, and to evaluate the effect of 10-MDP (10-methacryloyloxydecyl dihydrogen phosphate) containing primer on their bond strength. Twenty composite cylinders and Y-TZP disks were adhesively luted and divided into four groups based on cement type used and application or not of 10-MDP. The groups (n = 5 each) were S 10MDP (Surgi Dual Flo' Zr with 10-MDP); S no 10MDP (Surgi Dual Flo' Zr without 10-MDP); P 10MDP (Panavia V5 with 10-MDP); P no 10MDP (Panavia V5 without 10-MDP). Maximum load resistance (ML) and shear bond strength (SBS) were tested and mode of failure qualitative documented via scanning electron microscopy. The data were analyzed with one-way ANOVA, Holm-Sidak method, and Bayesian analysis. ML and SBS were significantly higher in S 10MDP than in S no 10MDP; and in P 10MDP than in P no 10MDP (p < 0.05). No significant differences were found between S 10MDP and P 10MDP; S no 10MDP and P no 10MDP (p > 0.05). Cohesive, adhesive, and mixed failure occurred among the groups. Bond strength between the experimental resin-based cement and Y-TZP was adequate for clinical application when 10-MDP was added. 10-MDP containing primer was effective improving the bond strength to Y-TZP more than the different type of resinous cement.

7.
Materials (Basel) ; 12(15)2019 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-31357726

RESUMO

BACKGROUND: The healing of sockets following teeth extraction results in a marked reduction of the height and width of the ridge. This in vivo study aims to assess and compare the efficacy of calcium sulphate (CS) and sintered nano-hydroxyapatite (NHA) in postextraction sockets. MATERIALS AND METHODS: 10 subjects were enrolled for single or multiple tooth extraction and implant placement. Each site was randomly assigned to one of four groups and filled with CS, NHA, a combination of CS and NHA, or left to normal healing. After five months tissue samples were harvested from the extraction sites and prepared for histological investigations. RESULTS: Histomorphometric analysis showed that the average percentages of vital bone was 13.56% ± 13.08% for CS, 17.84% ± 7.32% for NHA, 58.72% ± 8.77% for CS + NHA%, and 80.68% ± 21.8% for the controls; for the connective tissue the results were 33.25% ± 35.75% for CS, 55.88% ± 21.86% for NHA, 17.34% ± 8.51% for CS + NHA, and 22.62% ± 0.52% for the controls; for residual biomaterial the results were 0.56% ± 0.52% for CS group, 21.97% ± 0.79% for NHA, and 47.54% ± 20.13% for CS + NHA. Conclusions: Both biomaterials led to bone tissue formation after five months of healing. The combination of the biomaterials presented a better behavior when compared to the individual application.

8.
Materials (Basel) ; 11(12)2018 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-30469472

RESUMO

The aim of this in vitro study was to evaluate the alterations of a titanium surface after treatment with two different types of ultrasonic tips: conventional steel versus an innovative copper alloy silver-plated one. Twenty smooth-surface, grade IV unalloyed titanium discs were divided into two groups. The discs were ultrasonically instrumented and the scaler was connected with a loading machine. The surface morphology was examined using scanning electron microscopy (SEM) and fractal analysis of lacunarity was calculated to highlight the alteration of the surface using the two different tips. The SEM analysis showed different degrees of surface roughness between the two types of scaler tips. Moreover, these observations demonstrated that the new tip showed fewer irregularities on the disc's surface than the conventional steel tip. The statistical and fractal analysis showed a statistically significant difference between the two groups. Surface alterations of titanium induced by the conventional ultrasonic tips were much greater than those made by copper alloy silver plated tips. The presented results suggest that the use of this new ultrasonic tip may reduce the alterations on the implant surface during its use in dental practice.

9.
J Craniofac Surg ; 27(5): 1209-11, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27380570

RESUMO

Many techniques are described for atrophied mandibles rehabilitation. This article reports on 12 clinical patients of severely atrophied posterior mandibles. In all the patients, a cone beam is performed before the crestal surgical approach to inferior alveolar nerve (IAN) mobilization. For the realization of this technique the piezosurgery device was used to minimize IAN injuries. With the help of this device the selective cutting of the bone has been possible until IAN exposure, in the implant placement site. At the same time, the authors performed the implant osteotomy and implant placement. After 4 months of healing, all implants were osseointegrated and the implant-supported bridges were done.Evaluation by means of neurosurgery function test over a 36-months period found that all patients had a return to normal sensation, after a brief period of neurosensory disturbance.


Assuntos
Implantação Dentária Endóssea/métodos , Implantes Dentários , Mandíbula/cirurgia , Nervo Mandibular/cirurgia , Procedimentos Neurocirúrgicos/métodos , Piezocirurgia/métodos , Adulto , Feminino , Humanos , Masculino , Mandíbula/diagnóstico por imagem , Nervo Mandibular/fisiopatologia , Pessoa de Meia-Idade , Osseointegração , Radiografia Panorâmica
10.
J Craniofac Surg ; 27(5): 1205-8, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27300456

RESUMO

Perioral rhytides affect more than 90% of women, the impact of these problems on the patient's self-esteem can become important enough to affect quality of life in psychological and sociocultural terms. Basic science shows that skin rhytides are related to loss in quantity and function of dermal collagen fibers. An electrosurgical technology was used in this study for treatment of perioral rhytides. The authors treated 34 patients (26 women and 8 men) for perioral rhytides with voltaic arc dermabrasion technique. Patient ages ranged between 30 and 65 years and the majority (90%) of these perioral areas had class II and III wrinkle scores. Voltaic arc dermabrasion was used to remove the keratinized layer for point perioral area. Treatments are minimally painful and in the authors' experience require no anesthesia. No discomfort should be expected once the voltaic arc dermabrasion treatment is concluded. The perioral dermis appears as a pale, erythematous, dull surface. Bleeding is not seen unless excessive abrading occurs with the saline-moistened gauze. No hyperpigmentation, hypopigmentation, erythema, ecchymosis, pain, itching, outbreaks of herpes, infectious processes, and scarring were observed. All patients monitored for fine perioral rhytides showed a reduction in the treated area. Since skin-specific quality of life was significantly improved after "voltaic arc" treatment, this therapy can be recommended for patients with perioral rhytides skin wishing to improve their appearance.


Assuntos
Dermabrasão/métodos , Lábio/cirurgia , Ritidoplastia/métodos , Envelhecimento da Pele , Adulto , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Resultado do Tratamento
11.
J Craniofac Surg ; 27(3): 682-5, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27092918

RESUMO

BACKGROUND: Microgap is defined as the microscopic space that exists between the implant body and abutment. The main mechanism proposed for microgap-related crestal bone loss is the role of this space as a trap for bacteria and thus, as a putative etiological factor for inflammatory reaction in the peri-implant soft tissues. The aim of this paper was to evaluate, with X-ray 3D microtomography, the microscopic space that exists between the implant body and abutment with internal hexagon versus cone morse. METHODS: A total of 20 implants were used in this in vitro study. Ten implants per group were used. Ten implants presented a screw retained internal hexagon abutment (Group I) and 10 had a Cone Morse taper internal connection (Group II). RESULTS: In both types of Cone Morse internal connection implants there was no detectable separation at the implant/abutment in the area of the conical connection, and there was an absolute congruity without any microgaps between abutment and implant. No line was visible separating the implant and the abutment. On the contrary, in the internal hexagon screwed abutment numerous gaps and voids were present between the implant body and abutment. CONCLUSION: The results of the present study seem, then, to support the hypothesis that the length and the characteristics of the implant-abutment joint could be a reason for the observed differences in mechanical stability.


Assuntos
Projeto do Implante Dentário-Pivô , Imageamento Tridimensional , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Microtomografia por Raio-X , Fenômenos Biomecânicos , Humanos
12.
Clin Case Rep ; 3(7): 610-4, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26273452

RESUMO

Key Clinical Message The continuing resorption of the alveolar ridge will eventually result in insufficient bone height superior to the IAN, making dental implant placement impossible. The augmentation procedure above the IAN in terms of height provides sufficient bone for implant placement and allows long-term successful restoration of missing teeth with implant-supported prosthesis.

13.
J Craniofac Surg ; 26(3): 706-8, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25974776

RESUMO

The authors compared the efficacy of 2 different techniques for sinus membrane elevation for maxillary lining lifted using a lateral window approach: nasal suction technique and ultrasonic surgery approach versus traditional approach. Thirty partially edentulous patients, having bilaterally 1 to 5 mm of residual bone height and at least 5 mm bone width below the maxillary sinuses as measured on computed tomography scans, were randomized to receive two 2-stage sinus lift procedures using the lateral window approach. On one side, the sinus lining the membrane was elevated with nasal suction technique and ultrasonic surgery approach, whereas on the contralateral side the membrane was elevated after osteotomy prepared using a round oral surgery bur. No patient dropped out. Four small perforations of membrane (<5 mm) were observed in group 1 (control) but not in group 2 (test). A statistically significant difference was present between the incidence of sinus membrane perforation in group 1 versus 2 (control versus test) (P < 0.01). In conclusion, the sinus lift with ultrasonic surgery and nasal suction technique was used to prevent a perforation of sinus membrane.


Assuntos
Maxila/cirurgia , Seio Maxilar/lesões , Osteotomia/efeitos adversos , Rinoplastia/efeitos adversos , Sucção/efeitos adversos , Falha de Restauração Dentária , Humanos , Seio Maxilar/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Ultrassonografia
14.
Int J Periodontics Restorative Dent ; 30(1): 73-81, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20224833

RESUMO

One of the therapeutic options proposed for reconstruction of the atrophic posterior mandible is inferior alveolar nerve (IAN) mobilization with simultaneous implant placement. However, studies on the functionality of this neurovascular bundle after its mobilization have shown mixed results. This variability can be attributed both to the test methodology, which typically requires subjective answers from patients, and to the surgical procedure itself, which is highly dependent on operator technique. This article reports on a series of 10 cases of IAN mobilization using a device specifically engineered to simplify bone surgery. This device enables the oral surgeon to avoid overstretching the nerve by creating a smaller bone window and using an apicocoronal inclination of instruments to capture the neurovascular bundle. Evaluation by means of neurosurgery function tests over a 36-month period found that all patients had a return to normal sensation after a brief period of neurosensory disturbance. Subjective responses to a patient questionnaire confirmed these findings. The implant success rate was 100%.


Assuntos
Implantação Dentária Endóssea/métodos , Nervo Mandibular/cirurgia , Procedimentos Neurocirúrgicos/métodos , Distúrbios Somatossensoriais/prevenção & controle , Terapia por Ultrassom/métodos , Adulto , Idoso , Perda do Osso Alveolar/reabilitação , Feminino , Humanos , Masculino , Mandíbula/cirurgia , Pessoa de Meia-Idade , Exame Neurológico , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...