Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Nutr ; 151(8): 2446-2454, 2021 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-34036360

RESUMO

BACKGROUND: Data from the 2007-2010 NHANES suggested that vitamin D supplements contributed to increased serum concentrations of 25-hydroxyvitamin D [25(OH)D] in the US population. OBJECTIVES: We sought to determine whether 25(OH)D continued to increase during NHANES 2011-2014 and whether associations of 25(OH)D with preselected covariates differed across time periods. METHODS: For this study, 25(OH)D was measured in adults (≥20 y) using LC-MS/MS. Descriptive and regression analyses were stratified by survey period to investigate the effects of age, race-Hispanic origin, sex, season, BMI, dietary vitamin D, and vitamin D-containing supplements. A multiple linear regression model was used to assess 25(OH)D changes between two 4-y survey periods, namely 2007-2010 and 2011-2014. RESULTS: We observed several significant concomitant increases between 2007-2010 and 2011-2014: unadjusted mean 25(OH)D increased by 2.7 nmol/L (95% CI: 0, 5.4 nmol/L; P = 0.048), the percentage of persons taking any vitamin D-containing supplements increased 2.9% (95% CI: 0.03, 5.5%; P = 0.0314), and the percentage of persons taking high-dose (≥1000 IU/d) vitamin D-containing supplements increased 8.6% (95% CI: 6.9, 9.9%; P < 0.0001). With covariate adjustment, the increase in 25(OH)D from 2007-2010 to 2011-2014 was no longer statistically significant [1.4 nmol/L (95% CI: -3.0, 0.23 nmol/L; P = 0.09)]. After adjustments, several large differences in 25(OH)D remained, namely non-Hispanic blacks had 25(OH)D 22 nmol/L lower than that of non-Hispanic whites, and users of vitamin D-containing supplements ≥1000 IU/d had 25(OH)D 31 nmol/L higher than that of nonusers. CONCLUSIONS: After adjusting for vitamin D supplement dose, the overall adjusted increase in 25(OH)D was no longer statistically significant, suggesting that changes in US adults' 25(OH)D concentrations between NHANES periods 2007-2010 and 2011-2014 may primarily be associated with changes in vitamin D supplementation.


Assuntos
Deficiência de Vitamina D , Adulto , Cromatografia Líquida , Suplementos Nutricionais , Humanos , Inquéritos Nutricionais , Espectrometria de Massas em Tandem , Vitamina D/análogos & derivados , Deficiência de Vitamina D/epidemiologia
2.
Clin Chim Acta ; 487: 241-249, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30292631

RESUMO

BACKGROUND: Reference measurement procedures (RMP) have rigorous accuracy specifications. For total 25-hydroxyvitamin D, 25(OH)D, bias ≤1.7% and CV ≤5% are recommended. These quality specifications are impractical for minor analytes, such as 25(OH)D2. Furthermore, documentation on RMP quality performance specifications for the individual 25(OH)D metabolites and their daily application are missing. METHODS: To assess accuracy, we used zeta-scores. Daily, 5-10 specimens (duplicate) and 3 reference materials (singleton or duplicate) were measured for 25(OH)D3 and 25(OH)D2 using JCTLM-accepted LC-MS/MS RMPs. Protocols were repeated on 3-4 occasions to generate campaign results. We used separate zeta-score acceptability criteria for daily (≤|2|) and campaign (≤|1|) evaluations. Allowable imprecision was determined experimentally. RESULTS: Across 7 campaigns, unacceptable daily zeta-scores required repeating 2 runs for 25(OH)D3 and 5 runs for 25(OH)D2. Hence, the zeta-scores of acceptable reference material results indicated high accuracy. The allowable imprecision for the RMPs was ≤5% (daily) and ≤ 3% (campaign) for 25(OH)D3 and ≤ 7% (daily) and ≤ 4% (campaign) for 25(OH)D2, respectively. CONCLUSIONS: Using zeta-scores and experimentally derived imprecision, we developed a straightforward approach to assess the acceptability of individual 25(OH)D reference measurements, providing also much-needed practical accuracy specifications for 25(OH)D2.


Assuntos
25-Hidroxivitamina D 2/sangue , Calcifediol/sangue , Cromatografia Líquida/normas , Humanos , Padrões de Referência , Espectrometria de Massas em Tandem/normas
3.
Anal Chem ; 89(9): 4907-4913, 2017 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-28375002

RESUMO

The National Institute of Standards and Technology (NIST) has developed Standard Reference Material (SRM) 972a Vitamin D Metabolites in Frozen Human Serum as a replacement for SRM 972, which is no longer available. SRM 972a was developed in collaboration with the National Institutes of Health's Office of Dietary Supplements. In contrast to the previous reference material, three of the four levels of SRM 972a are composed of unmodified human serum. This SRM has certified and reference values for the following 25-hydroxyvitamin D [25(OH)D] species: 25(OH)D2, 25(OH)D3, and 3-epi-25(OH)D3. The value assignment and certification process included three isotope-dilution mass spectrometry approaches, with measurements performed at NIST and at the Centers for Disease Control and Prevention (CDC). The value assignment methods employed have been modified from those utilized for the previous SRM, and all three approaches now incorporate chromatographic resolution of the stereoisomers, 25(OH)D3 and 3-epi-25(OH)D3.


Assuntos
25-Hidroxivitamina D 2/sangue , Calcifediol/sangue , Cromatografia Líquida/normas , Espectrometria de Massas/normas , 25-Hidroxivitamina D 2/normas , Calcifediol/química , Calcifediol/normas , Humanos , Padrões de Referência , Valores de Referência , Estereoisomerismo , Estados Unidos , United States Government Agencies
4.
Am J Clin Nutr ; 104(2): 454-61, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27385610

RESUMO

BACKGROUND: Temporal trends in the US population's vitamin D status have been uncertain because of nonstandardized serum 25-hydroxyvitamin D [25(OH)D] measurements. OBJECTIVE: To accurately assess vitamin D status trends among those aged ≥12 y, we used data from the cross-sectional NHANESs. DESIGN: A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for measuring 25(OH)D (sum of 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3), calibrated to standard reference materials, was used to predict LC-MS/MS-equivalent concentrations from radioimmunoassay data (1988-2006 surveys; n = 38,700) and to measure LC-MS/MS concentrations (2007-2010 surveys; n = 12,446). Weighted arithmetic means and the prevalence of 25(OH)D above or below cutoff concentrations were calculated to evaluate long-term trends. RESULTS: Overall, mean predicted 25(OH)D showed no time trend from 1988 to 2006, but during 2007-2010 the mean measured 25(OH)D was 5-6 nmol/L higher. Those groups who showed the largest 25(OH)D increases (7-11 nmol/L) were older, female, non-Hispanic white, and vitamin D supplement users. During 1988-2010, the proportions of persons with 25(OH)D <40 nmol/L were 14-18% (overall), 46-60% (non-Hispanic blacks), 21-28% (Mexican Americans), and 6-10% (non-Hispanic whites). CONCLUSIONS: An accurate method for measuring 25(OH)D showed stable mean concentrations in the US population (1988-2006) and recent modest increases (2007-2010). Although it is unclear to what extent supplement usage compared with different laboratory methods explain the increases in 25(OH)D, the use of higher vitamin D supplement dosages coincided with the increase. Marked race-ethnic differences in 25(OH)D concentrations were apparent. These data provide the first standardized information about temporal trends in the vitamin D status of the US population.


Assuntos
Estado Nutricional , Deficiência de Vitamina D/epidemiologia , Vitamina D/sangue , Vitaminas/sangue , Adolescente , Adulto , Negro ou Afro-Americano , Idoso , Criança , Suplementos Nutricionais , Feminino , Hispânico ou Latino , Humanos , Masculino , Pessoa de Meia-Idade , Inquéritos Nutricionais , Estado Nutricional/etnologia , Prevalência , Estados Unidos/epidemiologia , Vitamina D/análogos & derivados , Vitamina D/uso terapêutico , Deficiência de Vitamina D/sangue , Deficiência de Vitamina D/prevenção & controle , Vitaminas/uso terapêutico , População Branca , Adulto Jovem
5.
Natl Health Stat Report ; (93): 1-16, 2016 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-27139932

RESUMO

BACKGROUND: Serum concentrations of 25-hydroxyvitamin D (25OHD) were measured for the National Health and Nutrition Examination Survey (NHANES) over the 1988-2006 period using a radioimmunoassay (RIA). In 2010, the Centers for Disease Control and Prevention (CDC) reissued RIA-harmonized 25OHD for NHANES 2004 and 2006, and advised users to adjust the original RIA data from 1988-1994 by using an equation. Beginning with NHANES 2007-2008, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method measured 25OHD. METHODS: A method comparison (bridging) study was designed to convert original RIA 25OHD to LC­MS/MS-equivalents. This report compares the predictive ability of a competitor regression model (Model 2) to the equations that CDC publicly released in 2015 (Model 1). The models differ by time period variable and use of transformations. RESULTS: The two models provided similar adjusted R(2) (Model 1: 88.9%, Model 2: 90.4%) and root mean square error of prediction (plus or minus 9 to 10 nanomoles per liter [nmol/L]). Applying these models to NHANES 1988­2006 RIA 25OHD, the Pearson correlation of LC­MS/MS-equivalent concentrations was 0.99; the median difference between models was 0 nmol/L (interquartile range: ­2.8 to 1 nmol/L). In contrast to declining RIA-harmonized 25OHD, both models showed little change in LC­MS/MS-predicted 25OHD over the 1988­2006 period. For 2001­2006, both models predicted similar prevalences of 25OHD less than 30 nmol/L, which were lower than the prevalence estimates based on RIA-harmonized data. Mean weighted LC­MS/MS-equivalent concentrations based on either model were about 3 nmol/L lower for the 1988­1994 survey and about 3 nmol/L higher for the 2001­2006 surveys, effectively smoothing out temporal trends observed using the harmonized RIA data. CONCLUSIONS: Given minimal differences between models, final selection was based on public availability of the regression data. The bridging equations provide a way to use the previous RIA results to obtain LC­MS/MS-equivalent concentrations and evaluate temporal trends in vitamin D status.


Assuntos
25-Hidroxivitamina D 2/sangue , Cromatografia Líquida/normas , Radioimunoensaio/normas , Espectrometria de Massas em Tandem/normas , Humanos , Modelos Lineares , Inquéritos Nutricionais , Valor Preditivo dos Testes , Padrões de Referência , Estatística como Assunto , Estados Unidos
6.
J Nutr ; 146(5): 1051-61, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27052537

RESUMO

BACKGROUND: The 2007-2010 NHANES provides the first US nationally representative serum 25-hydroxyvitamin D [25(OH)D] concentrations measured by standardized liquid chromatography-tandem mass spectrometry. OBJECTIVE: We describe patterns for total 25(OH)D and individual metabolites in persons aged ≥1 y stratified by race-ethnicity and grouped by demographic, intake, physiologic, and lifestyle variables. METHODS: We measured 25-hydroxycholecalciferol [25(OH)D3], 25-hydroxyergocalciferol [25(OH)D2], and C3-epimer of 25(OH)D3 [C3-epi-25(OH)D3] in serum samples (n = 15,652) from the 2007-2010 cross-sectional NHANES [total 25(OH)D = 25(OH)D3 + 25(OH)D2]. RESULTS: Concentrations (median, detection rate) of 25(OH)D3 (63.6 nmol/L, 100%) and C3-epi-25(OH)D3 (3.40 nmol/L, 86%) were generally detectable; 25(OH)D2 was detectable in 19% of the population. Total 25(OH)D, 25(OH)D3, and C3-epi-25(OH)D3 displayed similar demographic patterns and were strongly correlated (Spearman's r > 0.70). Concentrations of 25(OH)D2 (90th percentile) were much higher in persons aged ≥60 y (17.3 nmol/L) than in younger age groups (≤4.88 nmol/L). We noted significant race-ethnicity differences in mean total 25(OH)D [non-Hispanic blacks (NHBs), Hispanics, and non-Hispanic whites (NHWs): 46.6, 57.2, and 75.2 nmol/L, respectively] and in the prevalence of total 25(OH)D <30 nmol/L overall (24% of NHBs, 6.4% of Hispanics, and 2.3% of NHWs) as well as stratified by season (winter months: 30% of NHBs, 7.5% of Hispanics, and 3.8% of NHWs; summer months: 17% of NHBs, 4.4% of Hispanics, and 1.6% of NHWs). Persons with higher vitamin D intakes (diet, supplements, or both) and those examined during May-October had significantly higher total 25(OH)D. Significant race-ethnicity interactions in a multiple linear regression model confirmed the necessity of providing race-ethnicity-specific estimates of total 25(OH)D. CONCLUSIONS: Race-ethnicity differences in the prevalence of low total 25(OH)D remained strong even after adjustment for season to account for the NHANES design imbalance between season, latitude, and race-ethnicity. The strong correlation between C3-epi-25(OH)D3 and 25(OH)D3 may be because the epimer is a metabolite of 25(OH)D3. The presence of 25(OH)D2 mainly in older persons is likely a result of high-dose prescription vitamin D2.


Assuntos
Negro ou Afro-Americano , Hispânico ou Latino , Deficiência de Vitamina D/epidemiologia , Vitamina D/sangue , População Branca , 25-Hidroxivitamina D 2/sangue , Adolescente , Adulto , Fatores Etários , Idoso , Calcifediol/sangue , Criança , Pré-Escolar , Cromatografia Líquida de Alta Pressão/métodos , Dieta , Suplementos Nutricionais , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Estações do Ano , Espectrometria de Massas em Tandem/métodos , Estados Unidos/epidemiologia , Vitamina D/análogos & derivados , Deficiência de Vitamina D/sangue , Vitaminas/sangue , Adulto Jovem
7.
Anal Bioanal Chem ; 407(19): 5615-24, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25967149

RESUMO

The inaccuracy of routine serum 25-hydroxyvitamin D measurements hampers the interpretation of data in patient care and public health research. We developed and validated a candidate reference measurement procedure (RMP) for highly accurate quantitation of two clinically important 25-hydroxyvitamin D metabolites in serum, 25-hydroxyvitamin D2 [25(OH)D2] and 25-hydroxyvitamin D3 [25(OH)D3]. The two compounds of interest together with spiked deuterium-labeled internal standards [d 3-25(OH)D2 and d 6-25(OH)D3] were extracted from serum via liquid-liquid extraction. The featured isotope-dilution LC-MS/MS method used reversed-phase chromatography and atmospheric pressure chemical ionization in positive ion mode. A pentafluorophenylpropyl-packed UHPLC column together with isocratic elution allowed for complete baseline resolution of 25(OH)D2 and 25(OH)D3 from their structural C-3 isomers within 12 min. We evaluated method trueness, precision, potential interferences, matrix effects, limits of quantitation, and measurement uncertainty. Calibration materials were, or were traceable to, NIST Standard Reference Materials 2972. Within-day and total imprecision (CV) averaged 1.9 and 2.0% for 25(OH)D3, respectively, and 2.4 and 3.5% for 25(OH)D2, respectively. Mean trueness was 100.3% for 25(OH)D3 and 25(OH)D2. The limits of quantitation/limits of detection were 4.61/1.38 nmol/L for 25(OH)D3 and 1.46/0.13 nmol/L for 25(OH)D2. When we compared our RMP results to an established RMP using 40 serum samples, we found a nonsignificant mean bias of 0.2% for total 25(OH)D. This candidate RMP for 25(OH)D metabolites meets predefined method performance specifications (≤5% total CV and ≤1.7% bias) and provides sufficient sample throughput to meet the needs of the Centers for Disease Control and Prevention Vitamin D Standardization Certification Program. Graphical abstract Bias assessment using NIST standard reference materials. Legend CDC mean mass fractions (ng/g) ± U 95 (6 replicates per mean). NIST-certified mass fractions (ng/g) ± U 95 from the Certificates of Analysis.


Assuntos
25-Hidroxivitamina D 2/sangue , Calcifediol/sangue , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão , Humanos , Isótopos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...