1.
Medicina (Kaunas) ; 55(4)2019 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-30959832

RESUMO

Background and objectives: As the prevalence of obesity is increasing in a population, diagnostics becomes more problematic. Our aim was to compare the 3M Littmann 3200 Electronic Stethoscope and 3M Littman Cardiology III Mechanical Stethoscope in the auscultation of obese patients. Methods. A total of 30 patients with body mass index >30 kg/m² were auscultated by a cardiologist and a resident physician: 15 patients by one cardiologist and one resident and 15 patients by another cardiologist and resident using both stethoscopes. In total, 960 auscultation data points were verified by an echocardiogram. Sensitivity and specificity data were calculated. Results. Sensitivity for regurgitation with valves combined was higher when the electronic stethoscope was used by the cardiologist (60.0% vs. 40.9%, p = 0.0002) and the resident physician (62.1% vs. 51.5%, p = 0.016); this was also the same when stenoses were added (59.4% vs. 40.6%, p = 0.0002, and 60.9% vs. 50.7%, p = 0.016, respectively). For any lesion, there were no significant differences in specificity between the electronic and acoustic stethoscopes for the cardiologist (92.4% vs. 94.2%) and the resident physician (93.6% vs. 94.7%). The detailed analysis by valve showed one significant difference in regurgitation at the mitral valve for the cardiologist (80.0% vs. 56.0%, p = 0.031). No significant difference in specificity between the stethoscopes was found when all lesions, valves and both physicians were combined (93.0% vs. 94.4%, p = 0.30), but the electronic stethoscope had higher sensitivity than the acoustic (60.1% vs. 45.7%, p < 0.0001). The analysis when severity of the abnormality was considered confirmed these results. Conclusions. There is an indication of increased sensitivity using the electronic stethoscope. Specificity was high using the electronic and acoustic stethoscope.


Assuntos
Auscultação Cardíaca/instrumentação , Sopros Cardíacos/diagnóstico , Obesidade/fisiopatologia , Estetoscópios , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Índice de Massa Corporal , Cardiologistas , Ecocardiografia , Feminino , Perda Auditiva de Alta Frequência , Sopros Cardíacos/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/complicações , Sensibilidade e Especificidade
2.
J Clin Microbiol ; 49(3): 1119-21, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21209169

RESUMO

We quantified methicillin-resistant Staphylococcus aureus (MRSA) carriage. The greater the log(10) count in samples from the nares, the greater the likelihood that other body sites had been colonized. Log(10) counts among body sites were correlated. The greatest sensitivity value (98%) was determined for the combined results from 2 sites: the nares and the groin.


Assuntos
Portador Sadio/microbiologia , Staphylococcus aureus Resistente à Meticilina/isolamento & purificação , Infecções Estafilocócicas/microbiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Carga Bacteriana , Feminino , Virilha/microbiologia , Humanos , Masculino , Pessoa de Meia-Idade , Mucosa Nasal/microbiologia , Períneo/microbiologia