Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Pediatr Orthop ; 44(7): e574-e579, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38899976

RESUMO

BACKGROUND: Dog walking is associated with a significant injury burden among adults, but the risk of injury associated with dog walking among children is poorly understood. This study describes the epidemiology of children treated at US emergency departments for injuries related to leash-dependent dog walking. METHODS: The National Electronic Injury Surveillance System (NEISS) database was retrospectively analyzed to identify children (5 to 18 years of age) presenting to US emergency departments between 2001 and 2020 with dog walking-related injuries. Primary outcomes included annual estimates of injury incidence, injury characteristics, and risk factors for fracture or traumatic brain injury (TBI). Weighted estimates, odds ratios (ORs), and 95% confidence intervals (CIs) were generated using NEISS sample weights. RESULTS: An estimated 35,611 children presented to US emergency departments with injuries related to dog walking. The mean age of patients was 11 years, and most patients were girls (63%). Over half (55%) of injuries were orthopaedic, and patients commonly injured their upper extremity (57%) and were hurt while falling when pulled or tripped by the leash (55%). The most frequent injuries were wrist strain/sprain (5.6%), finger strain/sprain (5.4%), and ankle strain/sprain (5.3%). On multivariable analysis, injured children aged 5 to 11 years were more likely to have sustained a TBI (OR: 3.2, 95% CI: 1.1-9.7) or fracture (OR: 1.6; 95% CI: 1.1-2.3). Boys were more likely than girls to have experienced a fracture (OR: 2.0, 95% CI: 1.3-2.5). CONCLUSIONS: Dog walking-related injuries in children are primarily orthopaedic and involve the upper extremity. Younger children and boys are at greater risk for serious dog walking-related injuries. LEVEL OF EVIDENCE: Level III.


Assuntos
Serviço Hospitalar de Emergência , Caminhada , Humanos , Criança , Feminino , Masculino , Cães , Serviço Hospitalar de Emergência/estatística & dados numéricos , Adolescente , Estados Unidos/epidemiologia , Estudos Retrospectivos , Pré-Escolar , Caminhada/estatística & dados numéricos , Animais , Incidência , Fatores de Risco , Lesões Encefálicas Traumáticas/epidemiologia , Fraturas Ósseas/epidemiologia
2.
J Am Acad Orthop Surg ; 32(13): e642-e650, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38684136

RESUMO

INTRODUCTION: Web-based resources serve as a fundamental educational platform for orthopaedic trauma patients; however, they are frequently written above the recommended sixth-grade reading level, and previous studies have demonstrated this for the American Academy of Orthopaedic Surgeons (AAOS) web-based articles. In this study, we perform an updated assessment of the readability of AAOS trauma-related educational articles as compared with injury-matched education materials developed by the Orthopaedic Trauma Association (OTA). METHODS: All 46 AAOS trauma-related web-based ( https://www.orthoinfo.org/ ) patient education articles were analyzed for readability. Two independent reviewers used (1) the Flesch-Kincaid Grade Level (FKGL) and (2) the Flesch Reading Ease (FRE) algorithms to calculate the readability level. Mean readability scores were compared across body part categories. A one-sample t -test was done to compare mean FKGL with the recommended sixth-grade readability level and the average American adult reading level. A two-sample t -test was used to compare the readability scores of the AAOS trauma-related articles with those of the OTA. RESULTS: The average (SD) FKGL and FRE for the AAOS articles were 8.9 (0.74) and 57.2 (5.8), respectively. All articles were written above the sixth-grade reading level. The average readability of the AAOS articles was significantly greater than the recommended sixth-grade reading level ( P < 0.001). The average FKGL and FRE for all AAOS articles were significantly higher compared with those of the OTA articles (8.9 ± 0.74 versus 8.1 ± 1.14, P < 0.001 and 57.2 ± 5.8 versus 65.6 ± 6.6, P < 0.001, respectively). Excellent agreement was observed between raters for the FKGL 0.956 (95% confidence interval, 0.922 to 0.975) and FRE 0.993 (95% confidence interval, 0.987 to 0.996). DISCUSSION: Our findings suggest that after almost a decade, the readability of the AAOS trauma-related articles remains unchanged. The AAOS and OTA trauma patient education materials have high readability levels and may be too difficult for patient comprehension. A need remains to improve the readability of these commonly used trauma education materials.


Assuntos
Compreensão , Internet , Ortopedia , Educação de Pacientes como Assunto , Sociedades Médicas , Humanos , Estados Unidos , Ortopedia/educação , Letramento em Saúde , Ferimentos e Lesões , Cirurgiões Ortopédicos
3.
J Am Acad Orthop Surg ; 32(3): e146-e155, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37793148

RESUMO

INTRODUCTION: The purpose of this study was to evaluate the ability of the Pathologic Fracture Mortality Index (PFMI) to predict the risk of 30-day morbidity after pathologic fracture fixation and compare its efficacy with those of the American Society of Anesthesiologists (ASA) physical status, modified Charlson Comorbidity Index (mCCI), and modified frailty index (mFI-5). METHODS: Cohorts of 1,723 patients in the American College of Surgeons National Surgical Quality Improvement Program database from 2005 to 2020 and 159 patients from a tertiary cancer referral center who underwent fixation for impending or completed pathologic fractures of long bones were retrospectively analyzed. National Surgical Quality Improvement Program morbidity variables were categorized into medical, surgical, utilization, and all-cause. PFMI, ASA, mCCI, and mFI-5 scores were calculated for each patient. Area under the curve (AUC) was used to compare efficacies. RESULTS: AUCs predicting all-cause morbidity were 0.62, 0.54, and 0.56 for the PFMI, ASA, and mFI-5, respectively. The PFMI outperformed the ASA and mFI-5 in predicting all-cause ( P < 0.01), medical ( P = 0.01), and utilization ( P < 0.01) morbidities. In the 2005 to 2012 subset, the PFMI outperformed the ASA, mFI-5, and mCCI in predicting all-cause ( P = 0.01), medical ( P = 0.03), and surgical ( P = 0.05) morbidities but performed similarly to utilization morbidity ( P = 0.19). In our institutional cohort, the AUC for the PFMI in morbidity stratification was 0.68. The PFMI was associated with all-cause (odds ratio [OR], 1.30; 95% confidence interval [CI], 1.12 to 1.51; P < 0.001), medical (OR, 1.19; 95% CI, 1.03 to 1.40; P = 0.046), and utilization (OR, 1.32; 95% CI, 1.14 to 1.52; P < 0.001) morbidities but not significantly associated with surgical morbidity (OR, 1.21; 95% CI, 0.98 to 1.49; P = 0.08) in this cohort. DISCUSSION: The PFMI is an advancement in postoperative morbidity risk stratification of patients with pathologic fracture from metastatic disease. LEVEL OF EVIDENCE: III.


Assuntos
Fraturas Espontâneas , Humanos , Estudos Retrospectivos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Morbidade , Medição de Risco
4.
Clin Shoulder Elb ; 26(4): 343-350, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37957883

RESUMO

BACKGROUND: Our purpose was to evaluate a custom reverse total shoulder arthroplasty glenoid baseplate for severe glenoid deficiency, emphasizing the challenges with this approach, including short-term clinical and radiographic outcomes and complications. METHODS: This was a single-institution, retrospective series of 29 patients between January 2017 and December 2022 for whom a custom glenoid component was created for extensive glenoid bone loss. Patients were evaluated preoperatively and at intervals for up to 5 years. All received preoperative physical examinations, plain radiographs, and computed tomography (CT). Intra- and postoperative complications are reported. RESULTS: Of 29 patients, delays resulted in only undergoing surgery, and in three of those, the implant did not match the glenoid. For those three, the time from CT scan to implantation averaged 7.6 months (range, 6.1-10.7 months), compared with 5.5 months (range, 2-8.6 months) for those whose implants fit. In patients with at least 2-year follow-up (n=9), no failures occurred. Significant improvements were observed in all patient-reported outcome measures in those nine patients (American Shoulder and Elbow Score, P<0.01; Simple Shoulder Test, P=0.02; Single Assessment Numeric Evaluation, P<0.01; Western Ontario Osteoarthritis of the Shoulder Index, P<0.01). Range of motion improved for forward flexion and abduction (P=0.03 for both) and internal rotation up the back (P=0.02). Pain and satisfaction also improved (P<0.01 for both). CONCLUSIONS: Prolonged time (>6 months) from CT scan to device implantation resulted in bone loss that rendered the implants unusable. Satisfactory short-term radiographic and clinical follow-up can be achieved with a well-fitting device. Level of evidence: III.

5.
Med Sci Sports Exerc ; 55(9): 1577-1583, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37057718

RESUMO

PURPOSE: Dog walking is a popular daily activity, yet information regarding its injury burden is limited. This study describes the epidemiology of injuries related to leash-dependent dog walking among adults presenting to US emergency departments from 2001 to 2020. METHODS: A retrospective analysis was performed using the National Electronic Injury Surveillance System database to identify adults (≥18 yr) presenting to US emergency departments with leash-dependent dog walking-related injuries between 2001 and 2020. Outcomes included annual estimates of injury incidence, injury characteristics, and risk factors for sustaining a fracture or traumatic brain injury (TBI). Weighted estimates and 95% confidence intervals (CI) were generated using National Electronic Injury Surveillance System sample weights. RESULTS: Between 2001 and 2020, an estimated 422,659 adults presented to US emergency departments with injuries related to leash-dependent dog walking. The annual incidence increased more than fourfold during this period ( n = 7282 vs n = 32,306, P < 0.001). Most patients were women (75%) and adults age 40 to 64 yr (47%), with a mean age of 53 ± 0.5 yr. Patients commonly injured their upper extremity (51%) and were injured while falling when pulled or tripped by the leash (55%). The three most common injuries were finger fracture (6.9%), TBI (5.6%), and shoulder sprain/strain (5.1%). On multivariate analysis, fracture risk among dog walkers was higher in adults age ≥65 yr (odds ratio [OR], 2.1; 95% CI, 1.8-2.5) and women (OR, 1.5; 95% CI, 1.3-1.7). Risk of TBI was also elevated among older dog walkers (OR, 1.6; 95% CI, 1.3-2.0). CONCLUSIONS: Dog walking is associated with a considerable and rising injury burden. Dog owners should be informed of this injury potential and advised on risk-reduction strategies.

6.
Artigo em Inglês | MEDLINE | ID: mdl-36204395

RESUMO

The purpose of this study was to assess the influence of the COVID-19 pandemic on the 2021 orthopaedic surgery residency match outcomes. Because in-person away rotations and interviews were canceled during the 2020 to 2021 application cycle, we hypothesized that applicants would match at their home program at a higher rate in 2021 than in previous years. Methods: We queried allopathic orthopaedic surgery residency websites and social media accounts for names of residents and medical school information for cohorts matching from 2017 through 2021. To assess availability of and participation in virtual away rotations, we administered a survey to Accreditation Council for Graduate Medical Education-accredited allopathic orthopaedic surgery residency programs. The primary outcome was the annual proportion of applicants matching at the program affiliated with their medical school ("home program"). Subgroup analyses were stratified by Doximity reputation ranking and availability of a virtual away rotation. Results: We identified 2,632 residents who matched between 2017 and 2020 and 698 residents who matched in 2021. Overall home program match rate and likelihood of home matching were higher in 2021 compared with 2017 to 2020 (28% vs. 20%; odds ratio [OR] = 1.51, 95% confidence interval [CI] 1.24-1.82, p < 0.001). The increase in the home match rate at programs ranked in the top 30 (27% vs. 20%, p = 0.034) was similar to the increase at programs ranked outside the top 30 (28% vs. 20%, p < 0.001). Of the 66 (48%) programs that responded to the survey, 16 (24%) offered a virtual away rotation. Programs with a higher Doximity ranking were more likely than lower-ranked programs to offer a virtual away rotation (OR = 6.75, 95% CI 1.95-23.4, p = 0.003). Home match rates did not differ significantly between programs that offered a virtual away rotation and those that did not (26% vs. 32%, p = 0.271). Conclusions: A higher proportion of orthopaedic surgery residency applicants matched at their home program in 2021 compared with previous years. Limitations on in-person activities due to the COVID-19 pandemic may have contributed to this rise. Level of Evidence: N/A.

7.
Adv Mater ; 29(46)2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29024044

RESUMO

Despite the tremendous potential of bioprinting techniques toward the fabrication of highly complex biological structures and the flourishing progress in 3D bioprinting, the most critical challenge of the current approaches is the printing of hollow tubular structures. In this work, an advanced 4D biofabrication approach, based on printing of shape-morphing biopolymer hydrogels, is developed for the fabrication of hollow self-folding tubes with unprecedented control over their diameters and architectures at high resolution. The versatility of the approach is demonstrated by employing two different biopolymers (alginate and hyaluronic acid) and mouse bone marrow stromal cells. Harnessing the printing and postprinting parameters allows attaining average internal tube diameters as low as 20 µm, which is not yet achievable by other existing bioprinting/biofabrication approaches and is comparable to the diameters of the smallest blood vessels. The proposed 4D biofabrication process does not pose any negative effect on the viability of the printed cells, and the self-folded hydrogel-based tubes support cell survival for at least 7 d without any decrease in cell viability. Consequently, the presented 4D biofabrication strategy allows the production of dynamically reconfigurable architectures with tunable functionality and responsiveness, governed by the selection of suitable materials and cells.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...