Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 93(12): 123902, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36586918

RESUMO

This study investigates methods to optimize quasi-monochromatic, ∼10 ns long x-ray sources (XRS) for time-resolved x-ray diffraction measurements of phase transitions during dynamic laser compression measurements at the National Ignition Facility (NIF). To support this, we produce continuous and pulsed XRS by irradiating a Ge foil with NIF lasers to achieve an intensity of 2 × 1015 W/cm2, optimizing the laser-to-x-ray conversion efficiency. Our x-ray source is dominated by Ge He-α line emission. We discuss methods to optimize the source to maintain a uniform XRS for ∼10 ns, mitigating cold plasma and higher energy x-ray emission lines.

2.
Rev Sci Instrum ; 92(3): 033505, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33820103

RESUMO

DANTE is a diagnostic used to measure the x-radiation drive produced by heating a high-Z cavity ("hohlraum") with high-powered laser beams. It records the spectrally and temporally resolved radiation flux at x-ray energies between 50 eV and 20 keV. Each sensor configuration on DANTE is composed of filters, mirrors, and x-ray diodes to define 18 different x-ray channels whose output is voltage as a function of time. The absolute flux is then determined from the photometric calibration of the sensor configuration and a spectral reconstructing algorithm. The reconstruction of the spectra vs time from the measured voltages and known response of each channel has presented challenges. We demonstrate a novel approach here for quantifying the error on the determined flux based on the channel sensor configuration and most commonly used reconstruction algorithm. In general, we find that the integrated spectral flux from a hohlraum can robustly be reconstructed (within ∼14%) using a traditional unfold approach with as few as ten channels due to the underlying assumption of a largely Planckian spectral intensity distribution.

3.
Rev Sci Instrum ; 92(3): 033519, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33819987

RESUMO

The Opacity Platform on the National Ignition Facility (NIF) has been developed to measure iron opacities at varying densities and temperatures relevant to the solar interior and to verify recent experimental results obtained at the Sandia Z-machine, that diverge from theory. The first set of NIF experiments collected iron opacity data at ∼150 eV to 160 eV and an electron density of ∼7 × 1021 cm-3, with a goal to study temperatures up to ∼210 eV, with electron densities of up to ∼3 × 1022 cm-3. Among several techniques used to infer the temperature of the heated Fe sample, the absolutely calibrated DANTE-2 filtered diode array routinely provides measurements of the hohlraum conditions near the sample. However, the DANTE-2 temperatures are consistently low compared to pre-shot LASNEX simulations for a range of laser drive energies. We have re-evaluated the estimated uncertainty in the reported DANTE-2 temperatures and also the error generated by varying channel participation in the data analysis. An uncertainty of ±5% or better can be achieved with appropriate spectral coverage, channel participation, and metrology of the viewing slot.

4.
Rev Sci Instrum ; 91(12): 123502, 2020 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-33380006

RESUMO

Sentinel is a 16-channel, filtered x-ray diode array spectrometer that has been developed to measure ∼1 keV-20 keV x-ray emission generated by the National Ignition Facility (NIF) laser. Unlike the large, fixed-port versions of this diagnostic that currently exist on the NIF (known as Dante), Sentinel is a Diagnostic Instrument Manipulator compatible such that it can be fielded along the polar or equatorial lines-of-sight-an essential new capability for characterizing the often anisotropic x-ray emission from laser-driven sources. We present the diagnostic design along with preliminary diode calibrations and performance results. The novel, small-form-factor x-ray diode design allows for ≳5×-25× increased channel areal density over that of Dante, simultaneously enabling improved diagnostic robustness and fidelity of spectral reconstructions. While the Sentinel diagnostic is anticipated to improve line-of-sight spectral characterization of x-ray sources for a wide variety of programs on the NIF, the compact and portable design is also attractive to small- and mid-scale facilities with limited diagnostic real estate.

5.
Rev Sci Instrum ; 91(8): 083507, 2020 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-32872957

RESUMO

Filtered diode array spectrometers are routinely employed to infer the temporal evolution of spectral power from x-ray sources, but uniquely extracting spectral content from a finite set of broad, spectrally overlapping channel spectral sensitivities is decidedly nontrivial in these under-determined systems. We present the use of genetic algorithms to reconstruct a probabilistic spectral intensity distribution and compare to the traditional approach most commonly found in the literature. Unlike many of the previously published models, spectral reconstructions from this approach are neither limited by basis functional forms nor do they require a priori spectral knowledge. While the original intent of such measurements was to diagnose the temporal evolution of spectral power from quasi-blackbody radiation sources-where the exact details of spectral content were not thought to be crucial-we demonstrate that this new technique can greatly enhance the utility of the diagnostic by providing more physical spectra and improved robustness to hardware configuration for even strongly non-Planckian distributions.

6.
Rev Sci Instrum ; 89(10): 10I121, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399775

RESUMO

The one-dimensional imager of neutrons (ODIN) at the Sandia Z facility consists of a 10-cm block of tungsten with rolled edges, creating a slit imager with slit widths of either 250, 500, or 750 µm. Designed with a 1-m neutron imaging line of sight, we achieve about 4:1 magnification and 500-µm axial spatial resolution. The baseline inertial confinement fusion concept at Sandia is magnetized liner inertial fusion, which nominally creates a 1-cm line source of neutrons. ODIN was designed to determine the size, shape, and location of the neutron producing region, furthering the understanding of compression quality along the cylindrical axis of magnetized liner implosions. Challenges include discriminating neutrons from hard x-rays and gammas with adequate signal-to-noise in the 2 × 1012 deuterium-deuterium (DD) neutron yield range, as well as understanding the point spread function of the imager to various imaging detectors (namely, CR-39). Modeling efforts were conducted with MCNP6.1 to determine neutron response functions for varying configurations in a clean DD neutron environment (without x-rays or gammas). Configuration alterations that will be shown include rolled-edge slit orientation and slit width, affecting the resolution and response function. Finally, the experiment to determine CR-39 neutron sensitivity, with and without a high density polyethylene (n, p) converter, an edge spread function, and resolution will be discussed.

7.
Phys Plasmas ; 24(6): 063301, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29104422

RESUMO

Direct drive implosions of plastic capsules have been performed at the National Ignition Facility to provide a broad-spectrum (500-2000 eV) X-ray continuum source for X-ray transmission spectroscopy. The source was developed for the high-temperature plasma opacity experimental platform. Initial experiments using 2.0 mm diameter polyalpha-methyl styrene capsules with ∼20 µm thickness have been performed. X-ray yields of up to ∼1 kJ/sr have been measured using the Dante multichannel diode array. The backlighter source size was measured to be ∼100 µm FWHM, with ∼350 ps pulse duration during the peak emission stage. Results are used to simulate transmission spectra for a hypothetical iron opacity sample at 150 eV, enabling the derivation of photometrics requirements for future opacity experiments.

8.
Rev Sci Instrum ; 87(11): 11E330, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910695

RESUMO

The Dante is an 18 channel filtered diode array used at the National Ignition Facility (NIF) to measure the spectrally and temporally resolved radiation flux between 50 eV and 20 keV from various targets. The absolute flux is determined from the radiometric calibration of the x-ray diodes, filters, and mirrors and a reconstruction algorithm applied to the recorded voltages from each channel. The reconstructed spectra are very low resolution with features consistent with the instrument response and are not necessarily consistent with the spectral emission features from the plasma. Errors may exist between the reconstructed spectra and the actual emission features due to assumptions in the algorithm. Recently, a high resolution convex crystal spectrometer, VIRGIL, has been installed at NIF with the same line of sight as the Dante. Spectra from L-shell Ag and Xe have been recorded by both VIRGIL and Dante. Comparisons of these two spectroscopic measurements yield insights into the accuracy of the Dante reconstructions.

9.
Rev Sci Instrum ; 86(10): 103511, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26520959

RESUMO

Filtered x-ray diode (XRD) arrays are often used to measure x-ray spectra vs. time from spectrally continuous x-ray sources such as hohlraums. A priori models of the incident x-ray spectrum enable a more accurate unfolding of the x-ray flux as compared to the standard technique of modifying a thermal Planckian with spectral peaks or dips at the response energy of each filtered XRD channel. A model x-ray spectrum consisting of a thermal Planckian, a Gaussian at higher energy, and (in some cases) a high energy background provides an excellent fit to XRD-array measurements of x-ray emission from laser heated hohlraums. If high-resolution measurements of part of the x-ray emission spectrum are available, that information can be included in the a priori model. In cases where the x-ray emission spectrum is not Planckian, candidate x-ray spectra can be allowed or excluded by fitting them to measured XRD voltages. Examples are presented from the filtered XRD arrays, named Dante, at the National Ignition Facility and the Laboratory for Laser Energetics.

10.
Phys Rev Lett ; 114(6): 065502, 2015 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-25723227

RESUMO

A basic tenet of material science is that the flow stress of a metal increases as its grain size decreases, an effect described by the Hall-Petch relation. This relation is used extensively in material design to optimize the hardness, durability, survivability, and ductility of structural metals. This Letter reports experimental results in a new regime of high pressures and strain rates that challenge this basic tenet of mechanical metallurgy. We report measurements of the plastic flow of the model body-centered-cubic metal tantalum made under conditions of high pressure (>100 GPa) and strain rate (∼10(7) s(-1)) achieved by using the Omega laser. Under these unique plastic deformation ("flow") conditions, the effect of grain size is found to be negligible for grain sizes >0.25 µm sizes. A multiscale model of the plastic flow suggests that pressure and strain rate hardening dominate over the grain-size effects. Theoretical estimates, based on grain compatibility and geometrically necessary dislocations, corroborate this conclusion.


Assuntos
Modelos Teóricos , Tantálio/química , Teste de Materiais/métodos , Metais/química , Tamanho da Partícula
11.
Rev Sci Instrum ; 85(11): 11E117, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430296

RESUMO

Photons in the MeV range emitted from the dense plasma focus (DPF) at the NSTec North Las Vegas Facility have been measured with both neutron-damaged GaAs and natural diamond photoconductive detectors (PCDs). The DPF creates or "pinches" plasmas of various gases (e.g., H2, D2, Ne, Ar., etc.) that have enough energy to create MeV photons from either bremsstrahlung and/or (n,n(')) reactions if D2 gas is used. The high bandwidth of the PCDs enabled the first ever measurement of the fast micro-pinches present in DPF plasmas. Comparisons between a slower more conventional scintillator/photomultiplier tube based nuclear physics detectors were made to validate the response of the PCDs to fast intense MeV photon signals. Significant discrepancies in the diamond PCD responses were evident.

12.
Rev Sci Instrum ; 85(9): 095119, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25273784

RESUMO

The energy partitioning energy coupling experiments at the National Ignition Facility (NIF) have been designed to measure simultaneously the coupling of energy from a laser-driven target into both ground shock and air blast overpressure to nearby media. The source target for the experiment is positioned at a known height above the ground-surface simulant and is heated by four beams from the NIF. The resulting target energy density and specific energy are equal to those of a low-yield nuclear device. The ground-shock stress waves and atmospheric overpressure waveforms that result in our test system are hydrodynamically scaled analogs of full-scale seismic and air blast phenomena. This report summarizes the development of the platform, the simulations, and calculations that underpin the physics measurements that are being made, and finally the data that were measured. Agreement between the data and simulation of the order of a factor of two to three is seen for air blast quantities such as peak overpressure. Historical underground test data for seismic phenomena measured sensor displacements; we measure the stresses generated in our ground-surrogate medium. We find factors-of-a-few agreement between our measured peak stresses and predictions with modern geophysical computer codes.

13.
Artigo em Inglês | MEDLINE | ID: mdl-24125368

RESUMO

We report 3% conversion efficiency of laser energy into Kr K-shell (≈13 keV) radiation, consistent with theoretical predictions. This is ≈10× greater than previous work. The emission was produced from a 4.1-mm-diameter, 4-mm-tall gas pipe target filled with 1.2 or 1.5 atm of Kr gas. 160 of the National Ignition Facility laser beams deposited ≈700 kJ of 3ω light into the target in an ≈140 TW, 5.0-ns-duration square pulse. The Dante diagnostics measured ≈5 TW into 4π solid angle of ≥12 keV x rays for ≈4 ns, which includes both continuum emission and flux in the Kr He_{α} line at 13 keV.

14.
Rev Sci Instrum ; 83(10): 10E117, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126939

RESUMO

The Dante is a 15 channel filtered diode array which is installed on the OMEGA laser facility at the Laboratory for Laser Energetics, University of Rochester. The system yields the spectrally and temporally resolved radiation flux from 50 eV to 10 keV from various targets (i.e., Hohlraum, gas pipes, etc.). The absolute flux is determined from the radiometric calibration of the x-ray diodes, filters, and mirrors and an unfold algorithm applied to the recorded voltages from each channel. The unfold algorithm assumes an emitting source that is spatially uniform and has a constant area as a function of photon energy. The emitting x-ray source is usually considered to be the laser entrance hole (LEH) of a given diameter for Hohlraum type targets or the effective wall area of high conversion efficiency K-shell type targets. This assumption can be problematic for several reasons. High intensity regions or "hot spots" in the x-ray are observed where the drive laser beams strike the target. The "hot spots" create non-uniform emission seen by the Dante. Additionally, thinned walled (50 µm) low-Z targets (C(22)H(10)N(2)O(5)) have an energy dependent source size since the target's walls will be fully opaque for low energies (E < 2-3 keV) yet fully transmissive at higher energies. Determining accurate yields can be challenging for these types of targets. Discussion and some analysis will be presented.

15.
Rev Sci Instrum ; 83(10): 10E138, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126959

RESUMO

The volumetric heating of a thin copper target has been studied with time resolved x-ray spectroscopy. The copper target was heated by a plasma produced using the Lawrence Livermore National Laboratory's Compact Multipulse Terawatt (COMET) laser. A variable spaced grating spectrometer coupled to an x-ray streak camera measured soft x-ray emission (800-1550 eV) from the back of the copper target to characterize the bulk heating of the target. Radiation hydrodynamic simulations were modeled in two-dimensions using the HYDRA code. The target conditions calculated by HYDRA were post-processed with the atomic kinetics code CRETIN to generate synthetic emission spectra. A comparison between the experimental and simulated spectra indicates the presence of specific ionization states of copper and the corresponding electron temperatures and ion densities throughout the laser-heated copper target.

16.
Oncogene ; 31(30): 3525-35, 2012 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-22081069

RESUMO

The NF-κB transcription factor has a central role in diverse processes, including inflammation, proliferation and cell survival, and its activity is dysregulated in diseases such as autoimmunity and cancer. We recently identified the TRE17/ubiquitin-specific protease 6 (USP6) oncogene as the first de-ubiquitinating enzyme to activate NF-κB. TRE17/USP6 is translocated and overexpressed in aneurysmal bone cyst (ABC), a pediatric tumor characterized by extensive bone degradation and inflammatory recruitment. In the current study, we explore the mechanism by which TRE17 induces activation of NF-κB, and find that it activates the classical NF-κB pathway through an atypical mechanism that does not involve IκB degradation. TRE17 co-precipitates with IκB kinase (IKK), and IKK activity is augmented in stable cell lines overexpressing TRE17, in a USP-dependent manner. Optimal activation of NF-κB by TRE17 requires both catalytic subunits of IKK, distinguishing its mechanism from the classical and non-canonical pathways, which require either IKKß or IKKα, respectively. TRE17 stimulates phosphorylation of p65 at serine 536, a modification that has been associated with enhanced transcriptional activity and nuclear retention. Induction of S536 phosphorylation by TRE17 requires both IKKα and IKKß, as well as the IKKγ/NEMO regulatory subunit of IKK. We further demonstrate that TRE17(long) is highly tumorigenic when overexpressed in NIH3T3 fibroblasts, and that inhibition of NF-κB significantly attenuates tumor formation. In summary, these studies uncover an unexpected signaling mechanism for activation of classical NF-κB by TRE17. They further reveal a critical role for NF-κB in TRE17-mediated tumorigenesis, and suggest that NF-κB inhibitors may function as effective therapeutic agents in the treatment of ABC.


Assuntos
Transformação Celular Neoplásica/metabolismo , NF-kappa B/metabolismo , Fragmentos de Peptídeos/metabolismo , Proteínas Proto-Oncogênicas/metabolismo , Fatores de Transcrição/metabolismo , Ubiquitina Tiolesterase/metabolismo , Animais , Células HeLa , Humanos , Quinase I-kappa B/metabolismo , Camundongos , Camundongos Nus , Células NIH 3T3 , Serina/metabolismo
17.
Phys Rev E Stat Nonlin Soft Matter Phys ; 84(4 Pt 2): 046402, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22181278

RESUMO

We present a systematic study of Au charge state distributions (CSDs) from low density, nonlocal thermodynamic equilibrium plasmas created in the Livermore electron beam ion traps (EBIT-I and EBIT-II). X-ray emission from Ni-like to Kr-like Au ions has been recorded from monoenergetic electron beam plasmas having E(beam)=2.66, 2.92, 3.53, and 4.54 keV, and the CSDs of the beam plasmas have been inferred by fitting the collisionally excited line transitions and radiative recombination emission features with synthetic spectra. We have modeled the beam plasmas using a collisional-radiative code with various treatments of the atomic structure for the complex M- and N-shell ions and find that only models with extensive doubly excited states can properly account for the dielectronic recombination (DR) channels that control the CSDs. This finding would be unremarkable for plasmas with thermal electron distributions, where many such states are sampled, and the importance of DR is well established. But in an EBIT source, the beam is resonant with only a subset of such states having spectator electrons in orbitals with high principal quantum number n (8≤n≤20). The inclusion of such states in the model was also necessary to obtain agreement with observed stabilizing transitions in the x-ray spectra.

18.
Oncogene ; 30(1): 87-96, 2011 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-20818435

RESUMO

The oncogenic fusion protein RET/PTC3 (RP3) that is expressed in papillary thyroid carcinoma (PTC) and thyroid epithelia in Hashimoto's thyroiditis activates nuclear factor-kappa B (NF-κB) and induces pro-inflammatory gene expression; however, the mechanism of this activation is unknown. To address this, we expressed RP3 in murine embryonic fibroblasts (MEFs) lacking key classical and noncanonical NF-κB signaling components. In wild-type MEFs, RP3 upregulated CCL2, CXCL1, granulocyte-macrophage colony-stimulating factor and tumor necrosis factor expression and activated classical but not noncanonical NF-κB. RP3-activated NF-κB in IκB kinase (IKK)ß(-/-) MEFs but not IKKα- or NF-κB essential modulator (NEMO)-deficient cells and activation was inhibited by a peptide that blocks NEMO binding to the IKKs. RP3 increased the levels of NF-κB-inducing kinase (NIK) and did not activate NF-κB in NIK-deficient MEFs. Notably, NIK stabilization was not accompanied by TRAF3 degradation demonstrating that RP3 disrupts normal basal NIK regulation. Dominant-negative NIK blocked RP3-induced NF-κB activation and an RP3 signaling mutant (RP3(Y588F)) did not stabilize NIK. Finally, examination of PTC specimens revealed strong positive staining for NIK. We therefore conclude that RP3 activates classical NF-κB via NIK, NEMO and IKKα. Importantly, our findings reveal a novel mechanism for oncogene-induced NF-κB activation via stabilization of NIK.


Assuntos
Peptídeos e Proteínas de Sinalização Intracelular/metabolismo , NF-kappa B/metabolismo , Proteínas de Fusão Oncogênica/genética , Proteínas Serina-Treonina Quinases/metabolismo , Proteínas Proto-Oncogênicas c-ret/genética , Animais , Estabilidade Enzimática , Fibroblastos/citologia , Fibroblastos/metabolismo , Regulação da Expressão Gênica , Humanos , Camundongos , Proteínas de Fusão Oncogênica/metabolismo , Proteínas Proto-Oncogênicas c-ret/metabolismo , Transdução de Sinais , Neoplasias da Glândula Tireoide/genética , Neoplasias da Glândula Tireoide/metabolismo , Quinase Induzida por NF-kappaB
19.
Rev Sci Instrum ; 81(10): 10E318, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21034016

RESUMO

A 2400 lines/mm variable-spaced grating spectrometer has been used to measure soft x-ray emission (8-22 Å) from laser-produced plasma experiments at Lawrence Livermore National Laboratory's Compact Multipulse Terrawatt (COMET) Laser Facility. The spectrometer was coupled to a Kentech x-ray streak camera to study the temporal evolution of soft x rays emitted from the back of the Mylar and the copper foils irradiated at 10(15) W/cm(2). The instrument demonstrated a resolving power of ∼120 at 19 Å with a time resolution of 31 ps. The time-resolved copper emission spectrum was consistent with a photodiode monitoring the laser temporal pulse shape and indicated that the soft x-ray emission follows the laser heating of the target. The time and spectral resolutions of this diagnostic make it useful for studies of high temperature plasmas.

20.
Rev Sci Instrum ; 81(10): 10E319, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21034017

RESUMO

We have calibrated the x-ray response of a variable line spaced grating spectrometer, known as the VSG, at the Fusion and Astrophysics Data and Diagnostic Calibration Facility at the Lawrence Livermore National Laboratory (LLNL). The VSG has been developed to diagnose laser produced plasmas, such as those created at the Jupiter Laser Facility and the National Ignition Facility at LLNL and at both the Omega and Omega EP lasers at the University of Rochester's Laboratory for Laser Energetics. The bandwidth of the VSG spans the range of ∼6-60 Å. The calibration results presented here include the VSG's dispersion and quantum efficiency. The dispersion is determined by measuring the x rays emitted from the hydrogenlike and heliumlike ions of carbon, nitrogen, oxygen, neon, and aluminum. The quantum efficiency is calibrated to an accuracy of 30% or better by normalizing the x-ray intensities recorded by the VSG to those simultaneously recorded by an x-ray microcalorimeter spectrometer.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...