Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
3.
Anal Chem ; 69(7): 1406-13, 1997 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-9105181

RESUMO

The NIST/NCI Micronutrient Measurement Quality Assurance Program has conducted 33 interlaboratory comparison exercises for fat-soluble vitamin-related compounds in human sera over the past 12 years. Periodic reanalysis of lyophilized serum samples prepared from more than 70 different sera has enabled estimation of the short- and long-term measurement characteristics. Median- and interquartile-range-based statistics adequately estimate the distribution of results from laboratories that are in analytical control from total distributions that include a significant minority of outlier data. Short-term interlaboratory reproducibility standard deviations (SDs) are predictable functions of analyte concentration, with an asymptotic limit at low analyte concentration and a linear relationship at high concentrations. Long-term trends in the interlaboratory reproducibility can be estimated by standardizing the short-term SD at the observed analyte concentration to an expected SD at a given physiologically significant analyte concentration. The "average" laboratory's same-day analytical repeatability SD is about one-third of the estimated interlaboratory reproducibility; repeatability for longer periods between analyses is, on average, on better than the reproducibility. While a few exceptional laboratories have maintained excellent repeatability over the entire decade, long-term study measurements generated within a single laboratory are not generally more internally consistent than results from multiple laboratories. Enhanced and more consistently implemented intralaboratory quality control and quality assurance methods are required to further improve and maintain interlaboratory measurement comparability.


Assuntos
Laboratórios/normas , Micronutrientes/análise , Vitaminas/sangue , Humanos , Lipídeos , Controle de Qualidade , Reprodutibilidade dos Testes , Solubilidade
5.
Appl Theor Electrophor ; 6(1): 15-22, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-9072076

RESUMO

TreviGel-500, a new polysaccharide matrix containing AgaCryl, commercially available as a powder for slab gel electrophoresis, is now being applied to the separation of DNA fragments in capillary electrophoresis. The capillary mode allows the use of one to two orders of magnitude lower mass fractions of matrix and approximately five to six orders of magnitude lower sample quantities than the slab gel electrophoresis counterpart for optimal separation of DNA fragments in the 100 to 2,000 base pair size range. In the capillary mode, this new separation matrix forms a semi-rigid gel that demonstrates enhanced selectivity for DNA fragments in the 1,000 to 7,000 base pair size range relative to alternative size-sieving polymer solutions. In addition, this matrix offers the advantages of lower toxicity than acrylamide. Comparisons are drawn between the use of this matrix in both slab gel electrophoresis and capillary electrophoresis for the separation of DNA fragments with respect to the mass fraction of the matrix in buffer, the buffer composition and sample loading or injection parameters.


Assuntos
DNA/isolamento & purificação , Eletroforese Capilar/métodos , Eletroforese/métodos , Géis
6.
Anal Biochem ; 224(1): 286-92, 1995 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-7710084

RESUMO

An enzymatic assay using fluorometric detection for cholesterol determination in serum is described. Results were compared to a conventional enzymatic colorimetric procedure and to the definitive method, which is based on isotope dilution mass spectrometry. Fluorescence detection enhances sensitivity over current colorimetric methods by approximately two orders of magnitude, and the assay response is linear over three orders of magnitude of cholesterol concentration. The reaction is performed in a single step and can be performed with small sample (1 microliter) and reaction (200 microliters) volumes. The fluorescence intensity is stable after a 30-min sample incubation at room temperature. The sensitivity of this fluorescence assay makes it possible to measure subnanomoles of cholesterol, allowing accurate measurement of total cholesterol in 1 microliter of serum or less. This level of sensitivity will also allow measurement of cholesterol in various isolated lipoprotein fractions.


Assuntos
Colesterol/sangue , Colesterol Oxidase , Fluorometria , Humanos , Esterol Esterase
7.
Mutat Res ; 276(1-2): 11-22, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1370101

RESUMO

Standard Reference Materials (SRMs) from the National Institute of Standards and Technology (NIST) are often used in methods development and interlaboratory comparison studies since they are homogeneous and readily available to the scientific community. SRM 1649 (urban dust/organics), SRM 1650 (diesel particulate matter), and SRM 1597 (complex mixture of polycyclic aromatic hydrocarbons from coal tar) are three environmental samples which have been used by the scientific community for these purposes. These SRMs were originally developed to assist laboratories in validating analytical procedures for the determination of polycyclic organic compounds in complex mixtures. In addition, these SRMs have been valuable for the comparison of methodologies for bacterial bioassays and the development of bioassay-directed fractionation and bioassay-directed chemical analysis techniques. Most recently these SRMs were chosen for use as test samples in a collaborative study coordinated by the World Health Organization--International Programme on Chemical Safety. This paper provides a summary of much of the work to date (published and unpublished) on the chemical and biological characterization of these three SRMs. Information regarding the availability of other NIST SRMs that might be useful for these types of studies are provided also.


Assuntos
Testes de Mutagenicidade/normas , Poluentes Atmosféricos/toxicidade , Carbono/análise , Fracionamento Químico , Gasolina/toxicidade , Testes de Mutagenicidade/métodos , Compostos Policíclicos/toxicidade , Valores de Referência , Salmonella/efeitos dos fármacos , Solventes
8.
Mutat Res ; 276(1-2): 3-9, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1370107

RESUMO

In 1987, the International Programme on Chemical Safety (IPCS) in collaboration with the U.S. Environmental Protection Agency (U.S. EPA) and the U.S. National Institute of Standards and Technology (U.S. NIST) initiated an international collaborative study of the mutagenicity of complex environmental mixtures in the Ames Salmonella typhimurium mutation assay. The objectives of this study were: (1) to estimate the inter- and intra-laboratory variability associated with the extraction of mixtures for bioassay, (2) to estimate the inter- and intra-laboratory variability associated with the Salmonella typhimurium bioassay when applied to complex mixtures, and (3) to determine whether standard reference complex mixtures would be useful in mutagenicity studies and to evaluate whether reference or certified mutagenicity values determined from this collaborative study should be reported. The complex mixtures used in this study were selected from standard reference materials (SRMs) which had previously been issued by the U.S. NIST as SRM 1597 (coal tar), SRM 1649 (diesel particulate matter) and SRM 1650 (urban air particulate matter) with certified values for polycyclic aromatic hydrocarbons. These SRM complex mixtures are available to scientists as reference standards for analytical chemistry research and are under consideration as SRMs for mutagenicity studies of complex environmental mixtures. This paper briefly describes the final study design, protocol, selection of the complex mixtures, and implementation of this international study.


Assuntos
Mutagênicos , Laboratórios , Testes de Mutagenicidade/normas , Projetos Piloto , Valores de Referência , Salmonella typhimurium/efeitos dos fármacos
9.
J Chromatogr ; 568(1): 232-8, 1991 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-1770101

RESUMO

A high-performance liquid chromatographic (HPLC) method has been developed for measuring 18 beta-glycyrrhetinic acid (GRA) in human plasma in the range of 0.1-3 micrograms/ml. The acetate ester of GRA is added to the plasma as an internal standard, plasma proteins are denatured with urea to release GRA, and the GRA and the internal standard are extracted in an ion-pairing solid-phase extraction process. An isocratic, reversed-phase HPLC separation is used, followed by ultraviolet absorbance detection at 248 nm. The results from the analysis of five GRA-fortified plasma pools show a mean relative standard deviation of 7% and are accurate to within 10%. With evaporative concentration of the extract, the limit of detection for GRA in plasma is approximately 10 ng/ml.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Ácido Glicirretínico/sangue , Humanos
14.
JAMA ; 256(13): 1786-7, 1986 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-3747090

RESUMO

KIE: Organized medicine has been urged to take a firmer stand in declaring physician participation in the business aspects of medicine to be unethical. The author maintains that physicians must adjust to new realities and reassert control over medical care and compensation. Passive acceptance of the role of physician-employee may result in loss of the ability to respond to patients' needs, while involvement in business may allow physicians to use their positions for patient advocacy and to fund improved care or to increase compensation lost to discounted fees. Physicians must be active in developing new health care services and businesses to insure quality and avoid loss of control; organized medicine must have faith in professional integrity.^ieng


Assuntos
Atenção à Saúde/economia , Ética Médica , Defesa do Paciente , Regulamentação Governamental , Humanos , Marketing de Serviços de Saúde , Estados Unidos
15.
JAMA ; 254(8): 1077, 1985.
Artigo em Inglês | MEDLINE | ID: mdl-4021047
16.
Arch Neurol ; 41(5): 559-60, 1984 May.
Artigo em Inglês | MEDLINE | ID: mdl-6326715

RESUMO

A distinctive, mostly proprioceptive polyneuropathy can occur in association with gastric partitioning in morbidly obese subjects. The syndrome occurred also in a nonobese patient receiving parenteral hyperalimentation and involved cranial nerves. The only consistent etiologic feature is surgical obstruction at the level of the gastric fundus. The condition reverses on reestablishment of enteral alimentation.


Assuntos
Doenças do Sistema Nervoso/etiologia , Distúrbios Nutricionais/complicações , Doenças do Sistema Nervoso Periférico/etiologia , Idoso , Humanos , Masculino , Sensação , Síndrome
18.
Hosp Prog ; 61(9): 38-9, 42, 1980 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10248001
19.
J Chromatogr Sci ; 13(11): 535-40, 1975 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-1194395

RESUMO

The low concentration of hydrocarbons anticipated in pollution baseline studies necessitates the development of analytical techniques sensitive at the sub-microgram per kilogram concentration level. The method of analysis developed in this laboratory involves dynamic headspace sampling for volatile hydrocarbon components of the sample, followed by coupled-column liquid chromatography for the non-volatile components. These techniques require minimal sample handling, reducing the risk of sample component loss and/or sample contamination. Volatile sample components are separated from the matrix in a closed system and concentrated on a TENAX-GC packed pre-column, free from large amounts of solvent and ready for GC/GC-MS analysis. Non-volatile compounds, such as the benzpyrenes, may be extracted from large volumes of water and concentrated on a Bondapak C18 packed pre-column for coupled-column liquid chromatographic separation and analysis. Results of the application of these techniques to the analysis of samples from sites of known low level hydrocarbon contamination are presented and discussed.


Assuntos
Cromatografia , Hidrocarbonetos/análise , Água do Mar/análise , Poluentes Químicos da Água/análise , Poluentes da Água/análise , Cromatografia Gasosa , Cromatografia Líquida de Alta Pressão , Microquímica , Solventes
SELEÇÃO DE REFERÊNCIAS