Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
HCA Healthc J Med ; 1(4): 205-209, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-37425668

RESUMO

Description Left ventricular non-compaction cardiomyopathy is an uncommon type of cardiomyopathy caused by malformation of the myocardium during embryogenesis. This results in trabeculations within the ventricular wall that can affect the left and, less commonly, right ventricles. Presentation ranges from clinically asymptomatic to life-threatening arrhythmias. It is a rare and relatively unknown form of cardiomyopathy, though thought to be underdiagnosed. Prevalence is increasing due to improvements in imaging and awareness. Management is similar to that of other cardiomyopathies including angiotensin-converting-enzyme inhibitors or angiotensin receptor blockers, beta-blockers, diuretics, automatic implantable cardioverter defibrillator placement and cardiac transplantation. We present a case of a 38-year-old, otherwise healthy, Indian male who presented with flash pulmonary edema and was found to have left ventricular non-compaction cardiomyopathy. This report includes a review of left ventricular non-compaction cardiomyopathy.

2.
J Interv Card Electrophysiol ; 58(2): 141-146, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31732839

RESUMO

BACKGROUND: Warfarin is deemed safe compared to bridging with heparin in the peri-procedure setting while implanting cardiac devices. The timing of discontinuation and re-initiation of direct anticoagulant agents (DOACs) such as dabigatran, apixaban, and rivaroxaban in the peri-procedural setting in comparison to warfarin is not well studied. OBJECTIVE: We wanted to compare three DOAC agents with warfarin during cardiac device implantation. METHODS: Consecutive patients on treatment with dabigatran, rivaroxaban, or apixaban (group A) undergoing a cardiac device generator change, upgrade, or new implantation procedure were compared to those on warfarin (group B). Incidence of hematoma, infection, effusion, stroke, and other complications were noted at 1 day, 1 week, and 3 months. RESULTS: A total of 311 patients in group A underwent the above procedures with 73 patients on dabigatran, 153 on rivaroxaban, and 85 on apixaban. There were 467 patients on warfarin in group B. Mean age of the total population was 68 ± 12 years with 67% males and > 80% Caucasians. The last dose of the DOAC was the night prior to the procedure and resumed the night of the procedure (single dose interruption for apixaban and dabigatran and no un-interruption for rivaroxaban). There was no difference noted in the incidence of minor or major hematoma (9% vs 8.5%, p = 0.7). No stroke occurred in either group. CONCLUSION: Use of DOAC agents with transient interruption of one dose is as safe as warfarin in the peri-procedural setting during implantation of cardiac devices.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Fibrilação Atrial/tratamento farmacológico , Dabigatrana/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Piridonas , Rivaroxabana/efeitos adversos , Vitamina K , Varfarina/uso terapêutico
3.
Indian Pacing Electrophysiol J ; 16(5): 159-164, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27979375

RESUMO

BACKGROUND: Pocket hematoma is one of the most common complications following cardiac device implantation. This study examined the impact of this complication on in-hospital outcomes following Implantable Cardioverter Defibrillator (ICD) implantation. METHODS: Data from Nationwide Inpatient Sample (NIS) 2010 was queried to identify all primary implantations of ICDs and Cardiac Resynchronization Therapy Defibrillators (CRT-D) during the year 2010 using ICD-9 codes. We then identified the patients who experienced a procedure related hematoma during the hospital stay. We compared the outcomes of the patients with and without a hematoma complication. All analyses were performed using SPSS 20 complex samples using appropriate weights to adjust for the complex sampling design of the national database. RESULTS: Out of a total of 85,276 primary ICD implantations in the year 2010, 2233 (2.6% of the implantations) were complicated by a hematoma. Increased age (p < 0.001), and comorbidities such as congestive heart failure (odds ratio (OR) - 1.86, p < 0.001), coagulopathy (OR - 2.3, p < 0.001) and renal failure (OR - 1.52, p < 0.001) were associated with an increased risk of pocket hematoma formation. Patients who developed a hematoma had a longer hospitalization (9.1 days versus 5.5 days, p < 0.001) and higher in-hospital costs ($56,545 versus $47,015, p < 0.001) compared to patients who did not have a hematoma. Overall mortality associated with ICD implantation was low (0.6%), and hematoma formation did not adversely affect mortality (0.6% versus 0.4%, p = 0.63). CONCLUSION: Hematoma occurs infrequently after ICD implantation, however, it adversely impacts the cost of procedure and length of stay.

4.
Echocardiography ; 33(1): 117-32, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26492868

RESUMO

Echocardiography is the most common imaging modality for the assessment of cardiovascular tumors, followed by more advanced imaging modalities, such as cardiac computed tomography or cardiac magnetic resonance imaging. Non-neoplastic lesions that may simulate a true neoplasm on imaging are termed "cardiac pseudotumors." As echocardiography is the initial imaging modality where pseudotumors are identified, it is imperative to have a fundamental understanding of pseudotumors evaluation using echocardiography. There is paucity of the literature describing the different kinds of pseudotumors. This review is an attempt to describe common cardiac pseudotumors and to classify them based on their origin. The tumors arising from cardiac structures, such as epicardium, endocardium, or myocardium, were termed as "intrinsic" while the pseudotumors with no cardiac origin were termed as "extrinsic." The more common pseudotumors are described in detail with pertinent echocardiographic features and examples.


Assuntos
Neoplasias Cardíacas/diagnóstico por imagem , Diagnóstico Diferencial , Humanos , Ultrassonografia
5.
Tex Heart Inst J ; 42(3): 265-9, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26175645

RESUMO

Pseudoaneurysm formation has been reported in degenerated coronary artery saphenous vein bypass grafts, as well as in native coronary arteries after interventional procedures or blunt trauma. In contrast, pseudoaneurysm formation arising from the anastomotic site of native coronary vessels soon after coronary artery bypass grafting is rare, and neither the clinical presentation of this phenomenon nor its treatment is well described. We present the case of a 63-year-old man, a recent coronary artery bypass grafting patient, who presented with acute coronary syndrome due to a large and expanding pseudoaneurysm of the saphenous vein-to-ramus intermedius artery graft anastomosis. After several attempts, we successfully treated the pseudoaneurysm by means of percutaneous coil embolization. To our knowledge, this is the first report of acute coronary syndrome secondary to a pseudoaneurysm at the coronary artery-saphenous vein graft anastomosis. In addition, this appears to be the first report of the percutaneous treatment of such a pseudoaneurysm by means of coil embolization.


Assuntos
Síndrome Coronariana Aguda/etiologia , Falso Aneurisma/etiologia , Falso Aneurisma/cirurgia , Ponte de Artéria Coronária/efeitos adversos , Vasos Coronários/cirurgia , Veia Safena/cirurgia , Anastomose Cirúrgica/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade
6.
Pacing Clin Electrophysiol ; 38(10): 1236-45, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26172621

RESUMO

BACKGROUND: Recent studies have suggested that prolonged outpatient rhythm monitoring results in increased detection of atrial fibrillation (AF) in patients with cryptogenic stroke (CS). However, the best monitoring strategy and its clinical utility is debatable. OBJECTIVE: To compare the effectiveness of implantable loop recorder (ILR) versus wearable devices in identifying AF in patients with CS. METHODS AND RESULTS: Three randomized controlled trials (RCTs) and 13 observational studies were identified by database searches. Seven studies (enrolling 774 patients) employed ILR for AF detection for a median duration of 365 days (range 50-569 days). Ten studies (enrolling 996 patients) employed continuous monitoring with wearable devices for a median duration of 21 days (range 4-30 days). One study performed 7 days of monitoring with wearable device followed by implantation of ILR, thus included in both groups. Pooled odds ratio (OR) of identifying AF in RCTs showed increased detection of AF with prolonged monitoring (OR 4.54, 95% confidence interval [CI] 2.92, 7.06; P < 0.00001) compared to routine outpatient follow-up. Overall detection of AF with outpatient monitoring was 17.6% (CI: 12.5-22.7). There was significantly higher AF detection with ILR (23.3%; CI: 13.83-32.29) compared to wearable devices (13.6%; CI: 7.91-19.32; P < 0.05). Patients with AF were older in age compared to patients without AF. CONCLUSION: AF detection in patients with CS is improved with prolonged rhythm monitoring and is better with ILR compared to wearable devices. AF was more common in older patients. The clinical significance of these findings is unknown at this point.


Assuntos
Assistência Ambulatorial/estatística & dados numéricos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Eletrocardiografia Ambulatorial/estatística & dados numéricos , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Causalidade , Comorbidade , Humanos , Incidência , Pessoa de Meia-Idade , Ensaios Clínicos Controlados Aleatórios como Assunto , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Distribuição por Sexo , Taxa de Sobrevida
8.
J Interv Card Electrophysiol ; 43(3): 245-51, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25956479

RESUMO

PURPOSE: The left atrial appendage (LAA) is a well-known source of atrial natriuretic peptide (ANP) and therefore plays an important role in homeostasis. The neurohormonal impact of epicardial exclusion of the LAA with the LARIAT procedure is unknown. In this proof-of-concept study, we postulated that LAA exclusion would impact homeostasis as evidenced by changes in electrolytes and blood pressure (BP). METHODS: A total of 76 patients who underwent successful LAA exclusion were enrolled in this retrospective observational study utilizing a prospective registry. Electrolytes, BP, and heart rate (HR) were monitored before LARIAT and post-LARIAT (24 and 72 h and 6 months). RESULTS: There was a significant reduction of systolic BP (mmHg) at 24 h (113.3 ± 16.0; p < 0.0001) and 72 h (119.0 ± 18.4 mmHg; p < 0.0001) post-LARIAT when compared with pre-LARIAT BP (138.2 ± 21.3). The reduction in systolic BP persisted at 6-month follow-up (128.8 ± 17.3; p = 0.0005). There was significant reduction in serum sodium (mmol/L) at 24 h (135.4 ± 3.6; p < 0.0001) and 72 h (136.3 ± 3.7; p < 0.001) post-LARIAT when compared to pre-LARIAT (138.7 ± 3.2). The reduction in sodium was not persistent at 6-month follow-up (138.4 ± 3.3; p = 0.453). CONCLUSIONS: LAA exclusion results in an early and persistent decrease in systolic BP. Additionally, there is an early decline in serum sodium, which normalizes at long-term follow-up. The underlying mechanism leading to these changes is not entirely clear; however, it is likely related to neurohormonal changes post LAA exclusion.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Hipertensão/fisiopatologia , Técnicas de Sutura/efeitos adversos , Técnicas de Sutura/instrumentação , Desequilíbrio Hidroeletrolítico/fisiopatologia , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Pressão Sanguínea , Desenho de Equipamento , Feminino , Humanos , Hipertensão/diagnóstico , Hipertensão/etiologia , Ligadura/efeitos adversos , Ligadura/instrumentação , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento , Equilíbrio Hidroeletrolítico , Desequilíbrio Hidroeletrolítico/diagnóstico , Desequilíbrio Hidroeletrolítico/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...