Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Diagn Microbiol Infect Dis ; 104(2): 115764, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35917666

RESUMO

The COVID-19 pandemic highlighted the significance of readily available and easily performed viral testing for surveillance during future infectious pandemics. The objectives of this study were: to assess the performance of the Xpert Xpress Flu and/or RSV test, a multiplex PCR assay for detecting influenza A and B virus and respiratory syncytial virus nucleic acids in respiratory tract specimens, relative to the Quidel Lyra Influenza A+B assay and the Prodesse ProFlu+ assay, and the system's ease of use by minimally trained operators. Overall, the Xpert Xpress Flu/RSV test demonstrated a high positive and negative percent agreement with the comparator assays, and was easy to use and interpret results, based on the operators' feedback. We concluded that the Xpert Xpress Flu/RSV test is sensitive, specific, and easy to use for the diagnosis of influenza and RSV by minimally trained operators and can be a valuable tool in future infectious clusters or pandemics.


Assuntos
COVID-19 , Vírus da Influenza A , Influenza Humana , Infecções por Vírus Respiratório Sincicial , Vírus Sincicial Respiratório Humano , COVID-19/diagnóstico , Humanos , Vírus da Influenza A/genética , Vírus da Influenza B/genética , Influenza Humana/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Nasofaringe , Pandemias , Reação em Cadeia da Polimerase em Tempo Real/métodos , Infecções por Vírus Respiratório Sincicial/diagnóstico , Vírus Sincicial Respiratório Humano/genética , Sensibilidade e Especificidade
2.
Eur Urol Oncol ; 4(1): 93-101, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33004290

RESUMO

BACKGROUND: In patients with haematuria, a fast, noninvasive test with high sensitivity (SN) and negative predictive value (NPV), which is able to detect or exclude bladder cancer (BC), is needed. A newly developed urine assay, Xpert Bladder Cancer Detection (Xpert), measures five mRNA targets (ABL1, CRH, IGF2, UPK1B, and ANXA10) that are frequently overexpressed in BC. OBJECTIVE: To validate the performance of Xpert in patients with haematuria. DESIGN, SETTING, AND PARTICIPANTS: Voided precystoscopy urine specimens were prospectively collected at 22 sites from patients without prior BC undergoing cystoscopy for haematuria. Xpert, cytology, and UroVysion procedures were performed. Technical validation was performed and specificity (SP) was determined in patients without BC. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: Test characteristics were calculated based on cystoscopy and histology results, and compared between Xpert, cytology, and UroVysion. RESULTS AND LIMITATIONS: We included 828 patients (mean age 64.5 yr, 467 males, 401 never smoked). Xpert had an SN of 78% (95% confidence interval [CI]: 66-87) overall and 90% (95% CI: 76-96) for high-grade (HG) tumours. The NPV was 98% (95% CI: 97-99) overall. The SP was 84% (95% CI: 81-86). In patients with microhaematuria, only one HG patient was missed (NPV 99%). Xpert had higher SN and NPV than cytology and UroVysion. Cytology had the highest SP (97%). In a separate SP study, Xpert had an SP of 89% in patients with benign prostate hypertrophy and 92% in prostate cancer patients. CONCLUSIONS: Xpert is an easy-to-use, noninvasive test with improved SN and NPV compared with cytology and UroVysion, representing a promising tool for identifying haematuric patients with a low likelihood of BC who might not need to undergo cystoscopy. PATIENT SUMMARY: Xpert is an easy-to-perform urine test with good performance compared with standard urine tests. It should help identify (micro)haematuria patients with a very low likelihood to have bladder cancer.


Assuntos
RNA Mensageiro/análise , Urinálise , Neoplasias da Bexiga Urinária , Cistoscopia , Feminino , Hematúria/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias da Bexiga Urinária/diagnóstico
3.
Eur Urol ; 75(5): 853-860, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30553612

RESUMO

BACKGROUND: A fast, noninvasive test with high sensitivity (SN) and a negative predictive value (NPV), which is able to detect recurrences in bladder cancer (BC) patients, is needed. A newly developed urine assay, Xpert Bladder Cancer Monitor (Xpert), measures five mRNA targets (ABL1, CRH, IGF2, UPK1B, and ANXA10) that are frequently overexpressed in BC. OBJECTIVE: To validate Xpert characteristics in patients previously diagnosed with non-muscle-invasive BC. DESIGN, SETTING, AND PARTICIPANTS: Voided precystoscopy urine samples were prospectively collected at 22 sites. Xpert, cytology, and UroVysion were performed. If cystoscopy was suspicious for BC, a histologic examination was performed. Additionally, technical validation was performed and specificity was determined in patients without a history or clinical evidence of BC. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: Test characteristics were calculated based on cystoscopy and histology results, and compared between Xpert, cytology, and UroVysion. RESULTS AND LIMITATIONS: Of the eligible patients, 239 with a history of BC had results for all assays. The mean age was 71 yr; 190 patients were male, 53 never smoked, and 64% had previous intravesical immunotherapy (35%) or chemotherapy (29%). Forty-three cases of recurrences occurred. Xpert had overall SN of 74% (95% confidence interval [CI]: 60-85) and 83% (95% CI: 64-93) for high-grade (HG) tumors. The NPV was 93% (95% CI: 89-96) overall and 98% (95% CI: 94-99) for HG tumors. Specificity was 80% (95% CI: 73-85). Xpert SN and NPV were superior to those of cytology and UroVysion. Specificity in non-BC individuals (n=508) was 95% (95% CI: 93-97). CONCLUSIONS: Xpert has an improved NPV compared with UroVysion and cytology in patients under follow-up for BC. It represents a promising tool for excluding BC in these patients, reducing the need for cystoscopy. PATIENT SUMMARY: Xpert is an easy-to-perform urine test with good performance compared with standard urine tests. It should help optimize the follow-up of recurrent bladder cancer patients.


Assuntos
Recidiva Local de Neoplasia/diagnóstico , Recidiva Local de Neoplasia/urina , Vigilância da População/métodos , RNA Mensageiro/urina , Neoplasias da Bexiga Urinária/urina , Adulto , Idoso , Idoso de 80 Anos ou mais , Anexinas/genética , Biópsia , Hormônio Liberador da Corticotropina/genética , Cistoscopia , Feminino , Humanos , Fator de Crescimento Insulin-Like II/genética , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/genética , Valor Preditivo dos Testes , Estudos Prospectivos , Proteínas Proto-Oncogênicas c-abl/genética , Urinálise , Bexiga Urinária/patologia , Neoplasias da Bexiga Urinária/genética , Uroplaquina Ib/genética , Adulto Jovem
4.
J Clin Microbiol ; 56(7)2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29720432

RESUMO

Mycoplasma pneumoniae is a common cause of community-acquired pneumonia. The illumigene Mycoplasma Direct (iMD) DNA amplification assay is a qualitative in vitro test utilizing loop-mediated isothermal amplification (LAMP) technology for the direct detection of M. pneumoniae DNA in respiratory specimens. The iMD assay does not require the preextraction of nucleic acids from specimens, which is a prerequisite step for the previously approved illumigene Mycoplasma (iM) assay. The aim of this prospective multicenter study was to evaluate the performance characteristics of the newly developed iMD assay, compared with the iM assay. Subjects with symptoms of upper respiratory illnesses suggesting M. pneumoniae infection were enrolled at three sites in the United States. Respiratory specimens were obtained using dual throat swabs. One swab was tested with the iMD assay at each enrollment site. Reference testing with the iM assay was performed by the manufacturer. Among 456 specimens tested, the iM reference method detected M. pneumoniae in 25 specimens (5.5%), while the iMD assay identified 34 specimens (7.5%) as M. pneumoniae positive. There were 10 false-positive results and 1 false-negative result with the iMD assay. The overall positive and negative agreement rates were 96.0% (95% confidence interval [CI], 80.5 to 99.3%) and 97.7% (95% CI, 95.8 to 98.7%), respectively. The overall agreement rate was determined to be 97.6% (95% CI, 95.7 to 98.6%). We conclude that the iMD test results were comparable to the iM assay results. The removal of the DNA extraction step for the iMD assay simplifies testing, saves time, and reduces the costs of detecting M. pneumoniae from throat swabs, compared to the iM assay.


Assuntos
Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/normas , Mycoplasma pneumoniae/isolamento & purificação , Técnicas de Amplificação de Ácido Nucleico/normas , Pneumonia por Mycoplasma/diagnóstico , Infecções Respiratórias/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Testes Diagnósticos de Rotina , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Mycoplasma pneumoniae/genética , Faringe/microbiologia , Pneumonia por Mycoplasma/microbiologia , Estudos Prospectivos , Infecções Respiratórias/microbiologia , Sensibilidade e Especificidade , Estados Unidos , Adulto Jovem
5.
J Clin Microbiol ; 56(2)2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29142048

RESUMO

The Xpert Flu+RSV Xpress Assay is a fast, automated in vitro diagnostic test for qualitative detection and differentiation of influenza A and B viruses and respiratory syncytial virus (RSV) performed on the Cepheid GeneXpert Xpress System. The objective of this study was to establish performance characteristics of the Xpert Flu+RSV Xpress Assay compared to those of the Prodesse ProFlu+ real-time reverse transcription-PCR (RT-PCR) assay (ProFlu+) for the detection of influenza A and B viruses as well as RSV in a Clinical Laboratory Improvement Amendments (CLIA)-waived (CW) setting. Overall, the assay, using fresh and frozen nasopharyngeal (NP) swabs, demonstrated high concordance with results of the ProFlu+ assay in the combined CW and non-CW settings with positive percent agreements (PPA) (100%, 100%, and 97.1%) and negative percent agreements (NPA) (95.2%, 99.5%, and 99.6%) for influenza A and B viruses and RSV, respectively. In conclusion, this multicenter study using the Cepheid Xpert Flu+RSV Xpress Assay demonstrated high sensitivities and specificities for influenza A and B viruses and RSV in ∼60 min for use at the point-of-care in the CW setting.


Assuntos
Vírus da Influenza A/isolamento & purificação , Vírus da Influenza B/isolamento & purificação , Técnicas de Diagnóstico Molecular/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Reação em Cadeia da Polimerase em Tempo Real , Vírus Sincicial Respiratório Humano/isolamento & purificação , Automação Laboratorial , DNA Viral/genética , Humanos , Vírus da Influenza A/genética , Vírus da Influenza B/genética , Influenza Humana/diagnóstico , Influenza Humana/virologia , Técnicas de Diagnóstico Molecular/normas , Nasofaringe/virologia , Infecções por Vírus Respiratório Sincicial/diagnóstico , Infecções por Vírus Respiratório Sincicial/virologia , Vírus Sincicial Respiratório Humano/genética , Sensibilidade e Especificidade , Fatores de Tempo
6.
Sex Transm Dis ; 44(3): 161-165, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28182591

RESUMO

OBJECTIVES: North American and European advisory groups recommend testing for Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) with nucleic acid amplification tests. Testing is often performed on automated instruments. The objectives of this study were to process urines for the diagnosis of CT and NG and to examine workflow procedures and outcomes. METHODS: While processing 1, 24, 48, 96, and 192 urine specimens on 3 batch-mode systems which use 96-well plates: cobas 4800, m2000, and Viper XTR and the random access cartridge testing GeneXpert Infinity 80, we measured assay performance, hands-on time for processing and maintenance, reagents and plastics consumption, time required to obtain results, and testing accuracy. RESULTS: The Infinity 80 required the least hands-on time for single specimens and smaller batches, whereas the Viper XTR and m2000 required the most hands-on time for all batch sizes. Cumulative daily, weekly, and monthly maintenance was highest for the Viper XTR and lowest for Infinity 80. All batch-mode instruments consumed large amounts of disposables. Time to results was shortest for the Infinity 80, and the Viper XTR provided the shortest time for the batch-mode instruments. All systems showed similar diagnostic accuracy. CONCLUSIONS: Because detection performances were similar, issues of hands-on time, maintenance, time to results, and consumables are important operational factors for the diagnosis and treatment of CT/NG infections.


Assuntos
Infecções por Chlamydia/diagnóstico , Gonorreia/diagnóstico , Técnicas de Amplificação de Ácido Nucleico/instrumentação , Avaliação de Processos e Resultados em Cuidados de Saúde , Manejo de Espécimes/instrumentação , Urinálise/instrumentação , Infecções por Chlamydia/microbiologia , Chlamydia trachomatis , Gonorreia/microbiologia , Humanos , Neisseria gonorrhoeae , Técnicas de Amplificação de Ácido Nucleico/métodos , Sensibilidade e Especificidade , Manejo de Espécimes/métodos , Urinálise/métodos
7.
J Clin Microbiol ; 54(8): 2008-13, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27194690

RESUMO

Herpes simplex virus (HSV) causes acute and relapsing symptoms characterized by ulcerative lesions. Laboratory diagnosis of HSV in cutaneous or mucocutaneous lesions has historically been performed with the use of viral cell culture systems; however, these tests are laborious and suffer decreased sensitivity for advanced-stage lesions. The recent availability of FDA-cleared moderately complex assays has resulted in the increased use of molecular diagnostics for the routine detection of HSV in superficial swab specimens. We performed a clinical evaluation of the recently FDA-cleared illumigene HSV 1&2 loop-mediated isothermal amplification (LAMP) assay (Meridian Bioscience, Cincinnati OH) for the detection and differentiation of HSV-1 and HSV-2 in cutaneous and mucocutaneous swab specimens. A total of 1,153 clinical swab specimens were collected and tested at 7 different clinical centers. Each specimen was tested for the presence of HSV-1 and HSV-2 using the illumigene assay, and results were compared to those of the enzyme-linked virus-inducible system (ELVIS) as the reference method. Overall, the illumigene assay demonstrated a sensitivity and specificity of 94.8% and 95.5%, respectively, for the detection of HSV-1. Detection of HSV-2 was similar, with a sensitivity of 98.9% and a specificity of 95.5%. Discrepant analysis was performed using an alternative molecular test (AmpliVue HSV1+2 assay; Quidel Molecular, San Diego, CA) on 91/99 specimens that were recorded as false positive (FP) or false negative (FN) compared to the reference method. In total, 57/78 (73%) FP and 9/13 (69%) FN illumigene results were supported by the AmpliVue result. The illumigene HSV 1&2 assay demonstrated high sensitivity and specificity to detect and differentiate HSV in clinical specimens and identified 57 additional specimens that were positive for HSV compared to culture. The use of LAMP eliminates the need for the cycling of temperatures and provides results in less than 60 min, with approximately 2 min of hands-on time per specimen.


Assuntos
Herpes Genital/diagnóstico , Herpes Simples/diagnóstico , Herpesvirus Humano 1/isolamento & purificação , Herpesvirus Humano 2/isolamento & purificação , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Adulto Jovem
8.
Sex Transm Dis ; 43(6): 377-81, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27196259

RESUMO

BACKGROUND: The 2015 Sexually Transmitted Diseases Treatment Guidelines from the Centers for Disease Control and Prevention recommend testing for Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) using nucleic acid amplification tests, and prompt treatment of infected persons on site under direct observation. Faster time to results may enable treatment and management outcomes. METHODS: Workflow parameters for processing 1, 10, 48, 96, and 192 tests were determined in the GeneXpert Infinity 80 (Cepheid) and Panther (Hologic) instruments. RESULTS: In an Xpert CT/NG cartridge, the time to first results on the Infinity 80 was 1 hour 30 minutes for single or multiple tests and final results for 10, 48, 96, and 192 tests were available at 1 hour 37 minutes, 1 hour 54 minutes, 3 hour 17 minutes, and 5 hour 7 minutes, respectively. With the Aptima CT/GC assay on the Panther, the respective times were 3 hr 45 min for the first test result, and 3 hour 51 minutes, 4 hour 38 minutes, 5 hour 26 minutes, and 7 hour 4 minutes to final results. The Panther required more time for maintenance and consumed a greater variety of plastics and reagents but required less hands-on time when testing larger numbers of specimens. CONCLUSIONS: The Infinity 80 is a versatile instrument for continuous random access testing of small or large numbers of clinical specimens and may provide diagnostic results, in some settings, in time for treatment of CT and NG infections.


Assuntos
Infecções por Chlamydia/diagnóstico , Chlamydia trachomatis/isolamento & purificação , Gonorreia/diagnóstico , Neisseria gonorrhoeae/isolamento & purificação , Técnicas de Amplificação de Ácido Nucleico/instrumentação , Doenças Bacterianas Sexualmente Transmissíveis/diagnóstico , Infecções por Chlamydia/microbiologia , Chlamydia trachomatis/genética , Gonorreia/microbiologia , Humanos , Neisseria gonorrhoeae/genética , Sensibilidade e Especificidade , Doenças Bacterianas Sexualmente Transmissíveis/microbiologia , Fatores de Tempo , Fluxo de Trabalho
9.
J Clin Microbiol ; 53(2): 443-8, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25411176

RESUMO

Neonatal infection with Streptococcus agalactiae (group B Streptococcus [GBS]) is a leading cause of sepsis and meningitis in newborns. Recent guidelines have recommended universal screening of all pregnant women to identify those colonized with GBS and administration of peripartum prophylaxis to those identified as carriers to reduce the risk of early-onset GBS disease in neonates. Enriched culture methods are the current standard for prenatal GBS screening; however, the implementation of more sensitive molecular diagnostic tests may be able to further reduce the risk of early-onset GBS infection. We report a clinical evaluation of the Xpert GBS LB assay, a molecular diagnostic test for the identification of GBS from broth-enriched vaginal/rectal specimens obtained during routine prenatal screening. A total of 826 specimens were collected from women undergoing prenatal screening (35 to 37 weeks' gestation) and tested at one of three clinical centers. Each swab specimen was tested directly prior to enrichment using the Xpert GBS assay. Following 18 to 24 h of broth enrichment, each specimen was tested using the Xpert GBS LB assay and the FDA-cleared Smart GBS assay as a molecular diagnostic comparator. Results obtained using all three molecular tests were compared to those for broth-enriched culture as the gold standard. The sensitivity and specificity of the Xpert GBS LB assay were 99.0% and 92.4%, respectively, compared to those for the gold standard culture. The Smart GBS molecular test demonstrated sensitivity and specificity of 96.8% and 95.5%, respectively. The sensitivities of the two broth-enriched molecular methods were superior to those for direct testing of specimens using the Xpert GBS assay, which demonstrated sensitivity and specificity of 85.7% and 96.2%, respectively.


Assuntos
Técnicas Bacteriológicas/métodos , Técnicas de Diagnóstico Molecular/métodos , Complicações Infecciosas na Gravidez/diagnóstico , Diagnóstico Pré-Natal/métodos , Infecções Estreptocócicas/diagnóstico , Streptococcus agalactiae/isolamento & purificação , Feminino , Humanos , Recém-Nascido , Gravidez , Complicações Infecciosas na Gravidez/microbiologia , Reto/microbiologia , Sensibilidade e Especificidade , Infecções Estreptocócicas/microbiologia , Vagina/microbiologia
10.
J Clin Microbiol ; 53(3): 804-9, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25540397

RESUMO

A bloodstream infection with Staphylococcus aureus, including methicillin-resistant S. aureus (MRSA), is a serious condition that carries a high mortality rate and is also associated with significant hospital costs. The rapid and accurate identification and differentiation of methicillin-susceptible S. aureus (MSSA) and MRSA directly from positive blood cultures has demonstrated benefits in both patient outcome and cost-of-care metrics. We compare the next-generation Xpert MRSA/SA BC (Xpert) assay to the GeneOhm StaphSR (GeneOhm) assay for the identification and detection of S. aureus and methicillin resistance in prospectively collected blood culture broths containing Gram-positive cocci. All results were compared to routine bacterial culture as the gold standard. Across 8 collection and test sites, the Xpert assay demonstrated a sensitivity of 99.6% (range, 96.4% to 100%) and a specificity of 99.5% (range, 98.0% to 100%) for identifying S. aureus, as well as a sensitivity of 98.1% (range, 87.5% to 100%) and a specificity of 99.6% (range, 98.3% to 100%) for identifying MRSA. In comparison, the GeneOhm assay demonstrated a sensitivity of 99.2% (range, 95.2% to 100%) and a specificity of 96.5% (range, 89.2% to 100%) for identifying S. aureus, as well as a sensitivity of 94.3% (range, 87.5% to 100%) and a specificity of 97.8% (range, 96.1% to 100%) for identifying MRSA. Five of six cultures falsely reported as negative for MRSA by the GeneOhm assay were correctly identified as positive by the Xpert assay, while one culture falsely reported as negative for MRSA by the Xpert assay was correctly reported as positive by the GeneOhm assay.


Assuntos
Bacteriemia/diagnóstico , Técnicas Bacteriológicas/métodos , Sangue/microbiologia , Resistência a Meticilina , Técnicas de Diagnóstico Molecular/métodos , Infecções Estafilocócicas/diagnóstico , Staphylococcus aureus/isolamento & purificação , Adolescente , Adulto , Bacteriemia/microbiologia , Criança , Pré-Escolar , Humanos , Lactente , Estudos Prospectivos , Sensibilidade e Especificidade , Infecções Estafilocócicas/microbiologia , Staphylococcus aureus/classificação , Staphylococcus aureus/genética
11.
J Clin Microbiol ; 51(5): 1474-7, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23447639

RESUMO

Acute pharyngitis is a nonspecific symptom that can result from a number of viral or bacterial infections. For most etiologies, symptoms are self-limited and resolve without lasting effects; however, pharyngitis resulting from infection with Streptococcus pyogenes (a group A Streptococcus [GAS]) can be associated with serious sequelae, including acute rheumatic fever and acute glomerulonephritis. Rapid accurate detection of GAS in pharyngeal specimens from individuals suffering from pharyngitis aids in the management and selection of antibiotic therapy for these patients. A total of 796 pharyngeal swabs were collected at three separate clinical centers. Each specimen was analyzed using the illumigene group A strep DNA amplification assay (Meridian Bioscience Inc., Cincinnati, OH). To confirm GAS identification, the results were compared to those from direct and extracted culture methods using Gram staining and a GAS-specific latex agglutination test. Discrepant results were resolved using an alternative nucleic acid amplification test. The prevalence of culture-detected GAS in this study was 12.8% (102/796 specimens). The illumigene assay detected GAS in 74/74 direct culture-positive specimens (100% sensitivity) and 100/102 extracted culture-positive specimens (98.0% sensitivity). GAS was detected by the illumigene assay in an additional 42 specimens that were direct culture negative (94.2% specificity) and 16 specimens that were extracted culture negative (97.7% specificity). Discrepant analysis using an alternative molecular assay detected GAS nucleic acid in 13/16 (81.3%) false-positive specimens and 1/2 false-negative specimens, resulting in a final sensitivity of 99.0% and a specificity of 99.6% for the detection of GAS in pharyngeal swabs using the illumigene assay.


Assuntos
DNA Bacteriano/análise , Técnicas de Amplificação de Ácido Nucleico , Faringite/diagnóstico , Infecções Estreptocócicas/diagnóstico , Streptococcus pyogenes/genética , Humanos , Nasofaringe/microbiologia , Faringite/microbiologia , Infecções Estreptocócicas/microbiologia
12.
Diagn Microbiol Infect Dis ; 74(2): 151-7, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22770774

RESUMO

As part of the Tigecycline Evaluation and Surveillance Trial (TEST), bacterial isolates were collected consecutively from centers globally between 2004 and 2009. MICs were determined locally using Clinical and Laboratory Standards Institute broth microdilution methodology. A total of 3114 anaerobic and 99,256 aerobic isolates were included in this study. The most active agents against Gram-negative anaerobes were metronidazole and meropenem (resistance ranges 0.0-0.5% and 0.0-0.9%, respectively); piperacillin-tazobactam was also active (resistance range 0.5-9.4%). Among Gram-positive anaerobes, resistance rates were lowest for meropenem, piperacillin-tazobactam, and metronidazole (ranges 0.0-0.5%, 0.0-1.8%, and 0.0-3.2% respectively). Tigecycline MIC(90) values for anaerobes ranged from 0.12 to 2 µg/mL. The most active antimicrobial agent against Gram-negative aerobes (excluding Pseudomonas aeruginosa) was tigecycline, with resistance ranging from <0.01% to 1.4%. Resistance was also low for imipenem (0.3-9.4%) and meropenem (0.7-15.1%). Extended-spectrum beta-lactamases were produced by 12.2% and 19.7% of E. coli and K. pneumoniae isolates, respectively.


Assuntos
Antibacterianos/farmacologia , Bactérias Aeróbias/efeitos dos fármacos , Bactérias Anaeróbias/efeitos dos fármacos , Infecções Bacterianas/microbiologia , Infecções Intra-Abdominais/microbiologia , Minociclina/análogos & derivados , Bactérias Aeróbias/isolamento & purificação , Bactérias Anaeróbias/isolamento & purificação , Bactérias Gram-Negativas/efeitos dos fármacos , Bactérias Gram-Negativas/isolamento & purificação , Bactérias Gram-Positivas/efeitos dos fármacos , Bactérias Gram-Positivas/isolamento & purificação , Humanos , Testes de Sensibilidade Microbiana , Minociclina/farmacologia , Tigeciclina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...