1.
IEEE Trans Biomed Eng ; 51(8): 1444-8, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15311831

RESUMO

Fully differential amplifiers yield large differential gains and also high common mode rejection ratio (CMRR), provided they do not include any unmatched grounded component. In biopotential measurements, however, the admissible gain of amplification stages located before dc suppression is usually limited by electrode offset voltage, which can saturate amplifier outputs. The standard solution is to first convert the differential input voltage to a single-ended voltage and then implement any other required functions, such as dc suppression and dc level restoring. This approach, however, yields a limited CMRR and may result in a relatively large equivalent input noise. This paper describes a novel fully differential biopotential amplifier based on a fully differential dc-suppression circuit that does not rely on any matched passive components, yet provides large CMRR and fast recovery from dc level transients. The proposed solution is particularly convenient for low supply voltage systems. An example implementation, based on standard low-power op amps and a single 5-V power supply, accepts input offset voltages up to +/-500 mV, yields a CMRR of 102 dB at 50 Hz, and provides, in accordance with the AAMI EC38 standard, a reset behavior for recovering from overloads or artifacts.


Assuntos
Amplificadores Eletrônicos , Eletrofisiologia/instrumentação , Análise de Falha de Equipamento , Desenho Assistido por Computador , Desenho de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
IEEE Trans Biomed Eng ; 50(3): 391-5, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12669996

RESUMO

AC coupling is essential in biopotential measurements. Electrode offset potentials can be several orders of magnitude larger than the amplitudes of the biological signals of interest, thus limiting the admissible gain of a dc-coupled front end to prevent amplifier saturation. A high-gain input stage needs ac input coupling. This can be achieved by series capacitors, but in order to provide a bias path, grounded resistors are usually included, which degrade the common mode rejection ratio (CMRR). This paper proposes a novel balanced input ac-coupling network that provides a bias path without any connection to ground, thus resulting in a high CMRR. The circuit being passive, it does not limit the differential dc input voltage. Furthermore, differential signals are ac coupled, whereas common-mode voltages are dc coupled, thus allowing the closed-loop control of the dc common mode voltage by means of a driven-right-leg circuit. This makes the circuit compatible with common-mode dc shifting strategies intended for single-supply biopotential amplifiers. The proposed circuit allows the implementation of high-gain biopotential amplifiers with a reduced number of parts, thus resulting in low power consumption. An electrocardiogram amplifier built according to the proposed design achieves a CMRR of 123 dB at 50 Hz.


Assuntos
Amplificadores Eletrônicos , Eletrocardiografia/instrumentação , Eletrofisiologia/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Controle de Qualidade