Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acta Radiol ; 62(4): 462-473, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32611196

RESUMO

BACKGROUND: Localized pleural adhesion (LPA) evaluation in the apical region is difficult even with four-dimensional ultra-low-dose computed tomography (4D-ULDCT) in the supine position due to smaller pleural movements. PURPOSE: To assess usability of 4D-ULDCT in the lateral decubitus (LD) position for LPA detection in the apical region. MATERIAL AND METHODS: Forty-seven patients underwent 4D-ULDCT of a single respiration cycle with 16-cm coverage of body axis in supine and LD positions with the affected lung uppermost. Intraoperative thoracoscopic findings confirmed LPA presence. A pleural point and a corresponding point on costal outer edge were placed in identical axial planes at end-inspiration. Pleuro-chest wall distance between two points (PCD) was calculated at each respiratory phase. In the affected lung, average change in amount of PCD (PCDACA) was compared between patients with and without LPA in total and two sub-groups (non-COPD and COPD, non-emphysematous and emphysematous patients) in supine and non-dependent (ND) LD positions. Receiver operating characteristic (ROC) curve analysis was performed to determine optimal thresholds in PCDACA for differentiating patients with LPA from those without. RESULTS: In COPD/emphysematous patients and total population, PCDACA with LPA was smaller than in those without in the supine and NDLD positions for overall, lateral, and dorsal regions. For the lateral region in COPD patients, area under ROC curve (AUC) increased from supine (0.64) to NDLD position (0.81). For the dorsal region in emphysematous patients, AUC increased from supine (0.76) to NDLD position (0.96). CONCLUSION: 4D-ULDCT in LD position may be useful for LPA detection in apical regions for COPD and/or emphysematous patients.


Assuntos
Tomografia Computadorizada Quadridimensional , Posicionamento do Paciente , Doenças Pleurais/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Feminino , Tomografia Computadorizada Quadridimensional/métodos , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Aderências Teciduais
2.
Acta Radiol ; 61(12): 1608-1617, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32212830

RESUMO

BACKGROUND: It is still unclear which image reconstruction algorithm is appropriate for peripheral bronchial luminal conspicuity (PBLC) on dynamic-ventilation computed tomography (DVCT). PURPOSE: To assess the influence of radiation doses and temporal resolution (TR) on the association between movement velocity (MV) and PBLC on DVCT. MATERIAL AND METHODS: An ex vivo porcine lung phantom with simulated respiratory movement was scanned by 320-row CT at 240 mA and 10 mA. Peak and dip CT density and luminal area adjusted by values at end-inspiration (CTDpeak and CTDdip, luminal area ratio [LAR]) for PBLC and MVs were measured and visual scores (VS) were obtained at 12 measurement points on 13 frame images obtained at half and full reconstructions (TR 340 and 190 ms) during expiration. Size-specific dose estimate (SSDE) was applied to presume radiation dose. VS, CTDpeak, CTDdip, LAR, and their cross-correlation coefficients with MV (CCC) were compared among four methods with combinations of two reconstruction algorithms and two doses. RESULTS: The dose at 10 mA was presumed as 26 mA by SSDE for standard proportion adults. VS, CTDdip, CTDpeak, and LAR with half reconstruction at 10 mA (2.52 ± 0.59, 1.016 ± 0.221, 0.948 ± 0.103, and 0.990 ± 0.527) were similar to those at 240 mA except for VS, and different from those with full reconstruction at both doses (2.24 ± 0.85, 0.830 ± 0.209, 0.986 ± 0.065, and 1.012 ± 0.438 at 240 mA) (P < 0.05). CCC for CTDdip with half reconstruction (-0.024 ± 0.552) at 10 mA was higher compared with full reconstruction (-0.503 ± 0.291) (P < 0.05). CONCLUSION: PBLC with half reconstruction at 10 mA was comparable to that at 240 mA and better than those with full reconstruction on DVCT.


Assuntos
Brônquios/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Animais , Técnicas In Vitro , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Respiração , Estudos Retrospectivos , Suínos
3.
Eur J Radiol ; 98: 179-186, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29279160

RESUMO

PURPOSE: To assess the feasibility of Four-Dimensional Ultra-Low-Dose Computed Tomography (4D-ULDCT) for distinguishing pleural aspects with localized pleural adhesion (LPA) from those without. METHODS: Twenty-seven patients underwent 4D-ULDCT during a single respiration with a 16cm-coverage of the body axis. The presence and severity of LPA was confirmed by their intraoperative thoracoscopic findings. A point on the pleura and a corresponding point on the outer edge of the costal bone were placed in identical axial planes at end-inspiration. The distance of the two points (PCD), traced by automatic tracking functions respectively, was calculated at each respiratory phase. The maximal and average change amounts in PCD (PCDMCA and PCDACA) were compared among 110 measurement points (MPs) without LPA, 16MPs with mild LPA and 10MPs with severe LPA in upper lung field cranial to the bronchial bifurcation (ULF), and 150MPs without LPA, 17MPs with mild LPA and 9MPs with severe LPA in lower lung field caudal to the bronchial bifurcation (LLF) using the Mann-Whitney U test. RESULTS: In the LLF, PCDACA as well as PCDMCA demonstrated a significant difference among non-LPA, mild LPA and severe LPA (18.1±9.2, 12.3±6.2 and 5.0±3.3mm) (p<0.05). Also in the ULF, PCDACA showed a significant difference among three conditions (9.2±5.5, 5.7±2.8 and 2.2±0.4mm, respectively) (p<0.05), whereas PCDMCA for mild LPA was similar to that for non-LPA (12.3±5.9 and 17.5±11.0mm). CONCLUSIONS: Four D-ULDCT could be a useful non-invasive preoperative assessment modality for the detection of the presence or severity of LPA.


Assuntos
Tomografia Computadorizada Quadridimensional/métodos , Imageamento Tridimensional/métodos , Doenças Pleurais/diagnóstico por imagem , Cuidados Pré-Operatórios/métodos , Idoso , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pleura/diagnóstico por imagem , Doses de Radiação , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Estatísticas não Paramétricas
4.
Mol Immunol ; 45(6): 1720-31, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17997160

RESUMO

We previously demonstrated that some fish have unique response in the form of reactive oxygen species (ROS) production. In the present study, we cloned and sequenced the full-length cDNAs for carp (Cyprinus carpio) phagocyte NADPH oxidase components: gp91phox, p22phox, p47phox, p67phox and p40phox. These amino acid sequences were compared with other teleost and mammalian homologues, to elucidate the features of ROS production of fish neutrophils. The phylogeny analysis clearly demonstrates that the radiation of phagocyte oxidase components took place in the common ancestor of teleosts and mammals. Thereafter, the overall structure and expression pattern of phagocyte oxidase have been highly conserved in two different strains. However the amino acid identity of p67phox and p47phox was relatively lower than the amino acid identities of other components. Moreover, a synteny analysis supports the hypothesis that there was strong selective pressure in the p67phox and p47phox genes. Thus, it is likely that the higher divergence of p67phox and p47phox are responsible for the difference of ROS responses between different species of teleosts.


Assuntos
Carpas/metabolismo , NADPH Oxidases/metabolismo , Fagócitos/enzimologia , Sequência de Aminoácidos , Animais , Carpas/genética , Clonagem Molecular , Leucócitos/metabolismo , Dados de Sequência Molecular , NADPH Oxidases/genética , Filogenia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...