Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Eng Sci Med ; 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38421582

RESUMO

Workforce modelling for Radiation Oncology Medical Physicists (ROMPs) is evolving and challenging, prompting the development of the 2021 Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) ROMP Workforce (ARW) Model. In the exploration of this model at Sir Charles Gairdner Hospital, a comprehensive productivity exercise was conducted to obtain a detailed breakdown of ROMP time at a granular level. The results provide valuable insights into ROMP activities and enabled an evaluation of ARW Model calculations. The findings also capture the changing ROMP role as evidenced by an increasing involvement in consultation and advisory tasks with other professionals in the field. They also suggest that CyberKnife QA time requirements in the data utilised by the model may need to be revised. This study emphasises features inherent in the model, that need to be understood if the model is to be applied correctly.

2.
Front Oncol ; 12: 973431, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36408143

RESUMO

Objective: Current accepted linac Quality Assurance (QA) guidelines used for Volumetric Modulated Arc Therapy (VMAT) suggest a mechanical isocentre tolerance level of 1 mm. However, this tolerance level has not been well-established for the specific case of small field stereotactic VMAT. This study aims to evaluate the clinical impact of mechanical uncertainty on this treatment modality by modelling systematic gantry sag derived isocentre variance in the Treatment Planning System (TPS). Approach: A previously reported dataset of gantry sag values in the literature served as a starting point for this study. Using an in-house developed VMAT arc splitting algorithm, isocentre shifts were applied at a Control Point (CP) level to DICOM-RT treatment plans. Dose distributions for varying isocentre shift magnitudes were calculated for a set of 29 stereotactic VMAT plans using the Eclipse Acuros XB dose algorithm. These plans had a range of Planning Target Volume (PTV) sizes. A quantitative comparison of each plan was conducted by evaluating five Dose Volume Histogram (DVH)-derived plan quality metrics. Results: All metrics exhibited a deterioration in plan quality with increasing magnitudes of isocentre shift. At small PTV sizes, these effects were amplified, exhibiting significant changes at 1 mm of average shift when typical targets and tolerances were considered. For plans with PTVs between 0 and 5 cm3, a 1 mm shift reduced PTV coverage by 6.6 ± 2.2% and caused a 12.1 ± 3.8% deterioration in the conformity index. Based on the results of this study, the prevalent tolerance of 1 mm may not be suitable for treatments of small PTVs with small fields. Significance: In contrast to commonly accepted values, an absolute mechanical isocentre of 0.5 mm with action level at 0.75 mm is recommended for stereotactic VMAT of PTV sizes below 10 cm3.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...