Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Am Coll Cardiol ; 38(6): 1589-95, 2001 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-11704367

RESUMO

OBJECTIVES: The goal of this study was to determine whether carotid angioplasty and stenting (CAS) is equivalent to carotid endarterectomy (CEA) in patients with symptomatic carotid stenosis >70% by a randomized, controlled trial in a community hospital. BACKGROUND: Carotid angioplasty and stenting has been suggested to be as effective as CEA for treatment of symptomatic carotid artery stenosis. METHODS: A total of 104 patients presenting with cerebrovascular ischemia ipsilateral to carotid stenosis were selected randomly for CEA or carotid stenting and followed for two years. RESULTS: Stenosis decreased to an average of 5% after CAS. The patency of the reconstructed artery remained satisfactory regardless of the technique as determined by sequential ultrasound. One death occurred in the CEA group (1/51); one transient ischemic attack occurred in the CAS group (1/53); no individual sustained a stroke. The perception of procedurally related pain/discomfort was similar. Hospital stay was similar, although the CAS group tended to be discharged earlier (mean = 1.8 days vs. 2.7 days). Complications associated with CAS prolonged hospitalization when compared with those sustaining a CEA-related complication (mean = 5.6 days vs. 3.8 days). Return to full activity was achieved within one week by 80% of the CAS group and 67% of the patients receiving CEA. Hospital charges were slightly higher for CAS. CONCLUSIONS: Carotid stenting is equivalent to CEA in reducing carotid stenosis without increased risk for major complications of death/stroke. Because of shortened hospitalization and convalescence, CAS challenges CEA as the preferred treatment of symptomatic carotid stenosis if a reduction in costs can be achieved.


Assuntos
Angioplastia com Balão , Estenose das Carótidas/terapia , Endarterectomia das Carótidas , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Isquemia Encefálica/etiologia , Estenose das Carótidas/complicações , Feminino , Preços Hospitalares , Custos Hospitalares , Hospitais Comunitários , Humanos , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Complicações Pós-Operatórias , Fatores de Risco , Resultado do Tratamento , Grau de Desobstrução Vascular
2.
J Am Coll Cardiol ; 13(7): 1622-8, 1989 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-2723275

RESUMO

Opacification of the left heart chambers after venous injection of echo contrast agents with transpulmonary capabilities has been difficult to achieve because of a lack of availability of a biodegradable nontoxic agent that produces uniformly small microbubbles. SHU-508 is a new saccharide echo contrast agent that produces bubble sizes from 2 to 8 microns in diameter, capable of traversing the pulmonary capillary bed and resulting in left heart contrast. The echo intensity produced by this agent was compared with that of agitated saline solution, indocyanine green and SHU-454 (another experimental saccharide agent for right-sided contrast) during 136 injections in eight dogs. Videotaped two-dimensional echographic images were digitized and analyzed with the use of videodensitometry for peak right and left ventricular intensity, pulmonary transit times and time of persistence of contrast. The highest right ventricular intensity value (3,594 +/- 1,393) was achieved with SHU-508 (p less than 0.05 compared with the other agents). The right ventricular contrast seen with SHU-508 also persisted for a longer period (22.8 +/- 12 s) than with the standard agents (p less than 0.001). Left ventricular contrast with SHU-508 was visually evident in all 42 injections, whereas the peak left ventricular intensity was 35% as bright as that produced in the right ventricle by the same agent. Peak left ventricular intensity values from SHU-508 were compared with those from agitated saline solution injected from the pulmonary capillary wedge position in four dogs. SHU-508 produced brighter left ventricular intensity (1,281 +/- 607) compared with that obtained with the saline-wedge technique (p les than 0.002).(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Meios de Contraste , Ecocardiografia , Polissacarídeos , Animais , Densitometria/métodos , Cães , Verde de Indocianina , Masculino , Cloreto de Sódio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...