1.
J Obes Weight Loss Ther ; 1(106)2011 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-23730539

RESUMO

BACKGROUND: Physical activity is important in health and weight management. Several cell phone platforms integrate an accelerometer onto the motherboard. Here we tested the validity of the cell phone accelerometer to assess physical activity in a controlled laboratory setting. METHODS: 31 subjects wore the cell phone on their waist along with the validated Physical Activity Monitoring System (PAMS) with different body postures and during graded walking. Energy expenditure was measured using indirect calorimetry. 11 subjects also wore the iPhone at different locations such as arm, hand, pant pocket, etc. RESULTS: The cell phone accelerometer was accurate and precise compared to the PAMS, with an intra-class correlation coefficient (r2> 0.98). The cell phone accelerometer showed excellent sequential increases with increased in walking velocity and energy expenditure (r2>0.9). CONCLUSION: An accelerometer embedded into a cell phone was accurate and reliable in measuring and quantifying physical activity in the laboratory setting. Data from free-living users shows promise for deployment of a comprehensive integrated physical activity promoting and weight loss platform using such mobile technologies.

2.
Gait Posture ; 26(4): 489-93, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17869114

RESUMO

BACKGROUND: Microprocessor-controlled knee joints appeared on the market a decade ago. These joints are more sophisticated and more expensive than mechanical ones. The literature is contradictory regarding changes in gait and balance when using these sophisticated devices. METHODS: This study employed a crossover design to assess the comparative performance of a passive mechanical knee prosthesis compared to a microprocessor-controlled knee joint in 15 subjects with an above-knee amputation. Objective measurements of gait and balance were obtained. RESULTS: Subjects demonstrated significantly improved gait characteristics after receiving the microprocessor-controlled prosthetic knee joint (p<0.01). Improvements in gait were a transition from a hyperextended knee to a flexed knee during loading response which resulted in a change from an internal knee flexor moment to a knee extensor moment. The participants' balance also improved (p<0.01). All conditions of the Sensory Organization Test (SOT) demonstrated improvements in equilibrium score. The composite score also increased. CONCLUSIONS: Transfemoral amputees using a microprocessor-controlled knee have significant improvements in gait and balance.


Assuntos
Amputados/reabilitação , Membros Artificiais , Marcha/fisiologia , Prótese do Joelho , Microcomputadores , Equilíbrio Postural , Atividades Cotidianas , Adulto , Análise de Variância , Fenômenos Biomecânicos , Estudos Cross-Over , Humanos , Pessoa de Meia-Idade , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...