Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 226
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-30249685

RESUMO

Carbapenem-resistant Enterobacteriaceae (CRE) represent a health threat, but effective control interventions remain unclear. Hospital wastewater sites are increasingly being highlighted as important potential reservoirs. We investigated a large Klebsiella pneumoniae carbapenemase (KPC)-producing Escherichia coli outbreak and wider CRE incidence trends in the Central Manchester University Hospital NHS Foundation Trust (CMFT) (United Kingdom) over 8 years, to determine the impact of infection prevention and control measures. Bacteriology and patient administration data (2009 to 2017) were linked, and a subset of CMFT or regional hospital KPC-producing E. coli isolates (n = 268) were sequenced. Control interventions followed international guidelines and included cohorting, rectal screening (n = 184,539 screens), environmental sampling, enhanced cleaning, and ward closure and plumbing replacement. Segmented regression of time trends for CRE detections was used to evaluate the impact of interventions on CRE incidence. Genomic analysis (n = 268 isolates) identified the spread of a KPC-producing E. coli outbreak clone (strain A, sequence type 216 [ST216]; n = 125) among patients and in the environment, particularly on 2 cardiac wards (wards 3 and 4), despite control measures. ST216 strain A had caused an antecedent outbreak and shared its KPC plasmids with other E. coli lineages and Enterobacteriaceae species. CRE acquisition incidence declined after closure of wards 3 and 4 and plumbing replacement, suggesting an environmental contribution. However, ward 3/ward 4 wastewater sites were rapidly recolonized with CRE and patient CRE acquisitions recurred, albeit at lower rates. Patient relocation and plumbing replacement were associated with control of a clonal KPC-producing E. coli outbreak; however, environmental contamination with CRE and patient CRE acquisitions recurred rapidly following this intervention. The large numbers of cases and the persistence of blaKPC in E. coli, including pathogenic lineages, are of concern.


Assuntos
Infecção Hospitalar/epidemiologia , Surtos de Doenças , Infecções por Escherichia coli/epidemiologia , Escherichia coli/genética , Klebsiella pneumoniae/genética , beta-Lactamases/genética , Infecção Hospitalar/tratamento farmacológico , Infecção Hospitalar/microbiologia , Infecção Hospitalar/transmissão , DNA Bacteriano/genética , Reservatórios de Doenças/microbiologia , Escherichia coli/efeitos dos fármacos , Escherichia coli/isolamento & purificação , Escherichia coli/patogenicidade , Infecções por Escherichia coli/tratamento farmacológico , Infecções por Escherichia coli/microbiologia , Infecções por Escherichia coli/transmissão , Expressão Gênica , Transferência Genética Horizontal , Genótipo , Hospitais Universitários , Humanos , Controle de Infecções/métodos , Klebsiella pneumoniae/patogenicidade , Resíduos de Serviços de Saúde , Filogenia , Prevalência , Reino Unido/epidemiologia , Águas Residuárias/microbiologia
2.
Thyroid ; 28(7): 902-912, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29742993

RESUMO

BACKGROUND: The application of radioactive iodine in differentiated thyroid carcinomas has become more selective in an attempt to decrease morbidity. While ablative success has been documented, it is less clear how changes in radioactive iodine treatment strategies will influence long-term recurrence rates for patients with larger tumors and adverse pathological features, including extrathyroidal extension and nodal metastases. METHODS: Patients diagnosed between 1995 and 2008 with differentiated thyroid carcinoma treated with thyroidectomy followed by radioactive iodine treatment were eligible. All patients were followed for a minimum of five years using a standardized follow-up protocol requiring both biochemical and imaging assessments for recurrent disease (n = 219). Patients were stratified by initial radioactive iodine activity, and disease-free survival was calculated using the Kaplan-Meier method, with significant differences defined by the log-rank test. RESULTS: In this cohort, 46% of patients had clinical metastases and 74% had primary tumors >1.5 cm. Patients who had recurrences were more likely to present with extrathyroidal extension (p = 0.002) and lymph node metastases at diagnosis (p < 0.001). Patients presenting with both extrathyroidal extension and lymph node metastases had a significantly worse time to progression if treated with <1850 MBq radioactive iodine compared to those patients treated with >1850 MBq (25 months vs. 121 months; p = 0.004). The use of lower-activity radioactive iodine ablative therapy was associated with more early recurrences (p = 0.003). Being aged younger or older than 45 years did not impact the time to recurrence nor did the use of level 6 dissection. On multivariate analysis, lymph node metastases at diagnosis and multiple applications of radioactive iodine were linked to increased risk of recurrence. Patients with neither, or only one, adverse pathologic feature had excellent outcomes, regardless of initial ablative activity, with <10% of patients recurring over a 10-year time span. CONCLUSIONS: Recurrent disease in differentiated thyroid carcinoma is more common in patients treated with low-activity radioactive iodine in patients with lymph node metastases and extrathyroidal extension. These recurrences typically occur within four years of initial treatment. Patients lacking both of these risk factors treated with low radioactive iodine activity (<1850 MBq) have excellent outcomes, even after 10 years.


Assuntos
Carcinoma Papilar/radioterapia , Radioisótopos do Iodo/efeitos adversos , Metástase Linfática/radioterapia , Recidiva Local de Neoplasia/etiologia , Neoplasias da Glândula Tireoide/radioterapia , Adulto , Carcinoma Papilar/patologia , Intervalo Livre de Doença , Feminino , Seguimentos , Humanos , Radioisótopos do Iodo/uso terapêutico , Metástase Linfática/patologia , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/patologia , Fatores de Risco , Neoplasias da Glândula Tireoide/patologia
3.
Nucl Med Biol ; 60: 63-70, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29571068

RESUMO

This paper presents the irradiation and processing of high-current 100Mo targets at the University of Alberta (UofA) in a GMP compliant setting. For purpose of comparison with a second production facility, additional studies at Centre Hospitalier Universitaire de Sherbrooke (CHUS) are also described. INTRODUCTION: More than 70% of today's diagnostic radiopharmaceuticals are based on 99mTc, however the conventional supply chain for obtaining 99mTc is fragile. The aim of this work was to demonstrate reliable high yield production and processing of 99mTc with medium-energy, high-current, cyclotrons. METHODS: We used two cyclotrons (TR-24, Advanced Cyclotron Systems, Inc) for irradiations with 22 MeV or 24 MeV incident energy and 400 µA current up to a maximum of 6 h. The irradiated 100Mo was dissolved using peroxide, basified using ammonium carbonate, and purified using a PEG-based solid phase extraction technique. RESULTS: High-yield productions with 22 MeV (400 µA, 6 h) yielded an average isolated [99mTc]TcO4- yield of 878 GBq ±â€¯99 GBq (23.7 Ci ±â€¯2.7 Ci) decay corrected to EOB, n = 8 (isolated saturation yield: 4.36 ±â€¯0.49 GBq/µA). Irradiations with 24 MeV (400 µA, 6 h) resulted in an average isolated [99mTc]TcO4- yield of 993 GBq ±â€¯100 GBq (26.8 Ci ±â€¯2.7 Ci) decay corrected to EOB, n = 7 (isolated saturation yield: 4.97 ±â€¯0.50 GBq/µA). These yields corresponds to 600-700 GBq (16-19 Ci) of [99mTc]TcO4- at release (i.e. 3 hour post-EOB). For all tested batches, the QC results were within the recently published specifications in the European Pharmacopoeia. CONCLUSION: Reliable near-TBq production yields for 99mTc can be obtained using medium-energy cyclotrons. ADVANCES IN KNOWLEDGE AND IMPLICATIONS FOR PATIENT CARE: This work presents evidence that medium-energy high-current cyclotrons can provide high yields of [99mTc]TcO4- with radionuclidic impurities levels within the specifications of the existing European Pharmacopoeia monograph, indicating that this technology can have a share in the future 99mTc supply market.


Assuntos
Ciclotrons , Radioquímica/instrumentação , Pertecnetato Tc 99m de Sódio/química , Endotoxinas/análise
4.
Physiol Meas ; 38(10): R253-R279, 2017 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-28869423

RESUMO

Management and monitoring of infants within the neonatal intensive care unit represents a unique challenge. It involves an array of life-threatening diseases, procedures with potentially lifelong impacts, co-morbidities associated with preterm birth and risk of infection from prolonged exposure to the hospital environment. With the integration of monitoring systems and increasing accessibility of high-resolution data, there is a growing interest in the utility of advanced data analyses in predictive monitoring and characterising patterns of disease. Such analyses may offer an opportunity to identify infants at high risk of certain conditions and to detect the onset of disease prior to manifestation of clinical signs. This allows caregivers more time to respond and mitigate any abnormal or potentially fatal changes. We review techniques for variability analysis as they have been or have the potential to be applied to neonatal intensive care, the disease conditions in which they have been tested, and technical as well as clinical challenges relevant to their application.


Assuntos
Unidades de Terapia Intensiva Neonatal , Monitorização Fisiológica , Processamento de Sinais Assistido por Computador , Humanos , Recém-Nascido
5.
Eur J Nucl Med Mol Imaging ; 44(2): 234-241, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27663238

RESUMO

PURPOSE: A robust method is required to standardise objective reporting of diagnostic 123I-mIBG images in neuroblastoma. Prerequisites for an appropriate system are low inter- and intra-observer error and reproducibility across a broad disease spectrum. We present a new reporting method, developed and tested for SIOPEN by an international expert panel. METHOD: Patterns of abnormal skeletal 123I-mIBG uptake were defined and assigned numerical scores [0-6] based on disease extent within 12 body segments. Uptake intensity was excluded from the analysis. Data sets from 82 patients were scored independently by six experienced specialists as unblinded pairs (pre- and post-induction chemotherapy) and in random order as a blinded study. Response was defined as ≥50 % reduction in post induction score compared with baseline. RESULTS: In total, 1968 image sets were reviewed individually. Response rates of 88 % and 82 % were recorded for patients with baseline skeletal scores ≤23 and 24-48 respectively, compared with 44 % response in patients with skeletal scores >48 (p = 0.02). Reducing the number of segments or extension scale had a small but statistically negative impact upon the number of responses detected. Intraclass correlation coefficients [ICCs] calculated for the unblinded and blinded study were 0.95 at diagnosis and 0.98 and 0.99 post-induction chemotherapy, respectively. CONCLUSIONS: The SIOPEN mIBG score method is reproducible across the full spectrum of disease in high risk neuroblastoma. Numerical assessment of skeletal disease extent avoids subjective evaluation of uptake intensity. This robust approach provides a reliable means with which to examine the role of 123I mIBG scintigraphy as a prognostic indicator in neuroblastoma.


Assuntos
3-Iodobenzilguanidina , Neoplasias Ósseas/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/normas , Neuroblastoma/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada de Emissão de Fóton Único/normas , Neoplasias Ósseas/classificação , Europa (Continente) , Humanos , Internacionalidade , Neuroblastoma/classificação , Variações Dependentes do Observador , Guias de Prática Clínica como Assunto , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
J Clin Microbiol ; 54(7): 1814-1819, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27122379

RESUMO

Rapid identification of patients who are colonized with carbapenemase-producing organisms (CPO) is included in multiple national guidelines for containment of these organisms. In a multisite study, we evaluated the performance of the Cepheid Xpert Carba-R assay, a qualitative diagnostic test that was designed for the rapid detection and differentiation of the blaKPC, blaNDM, blaVIM, blaOXA-48, and blaIMP-1 genes from rectal swab specimens. A double rectal swab set was collected from 383 patients admitted at four institutions (2 in the United States, 1 in the United Kingdom, 1 in Spain). One swab was used for reference culture (MacConkey broth containing 1 mg/liter of meropenem and subcultured to a MacConkey agar plate with a 10-µg meropenem disk) and for sequencing of DNA obtained from carbapenem-nonsusceptible isolates for carbapenemase identification. The other swab was used for the Xpert Carba-R assay. In addition to the clinical rectal swabs, 250 contrived specimens (108 well-characterized CPO and 142 negative controls spiked onto negative rectal swabs) were tested. Overall, 149/633 (23.5%) samples were positive by the Xpert Carba-R assay. In 6 samples, multiple targets were detected (4 VIM/OXA-48, 1 IMP-1/NDM, and 1 NDM/KPC). The Xpert Carba-R assay detected 155 targets (26 IMP-1, 30 VIM, 27 NDM, 33 KPC, 39 OXA-48) within a time range of 32 to 48 min. The sensitivity, specificity, and positive and negative predictive values of the Xpert Carba-R assay compared to those of the reference culture and sequencing results were 96.6% (95% confidence interval [CI], 92.2% to 98.9%), 98.6% (95% CI, 97.1% to 99.4%), 95.3%, and 99.0%, respectively. The Cepheid Xpert Carba-R assay is an accurate and rapid test to identify rectal colonization with CPO, which can guide infection control programs to limit the spread of these organisms.


Assuntos
Proteínas de Bactérias/análise , Bactérias Gram-Negativas/enzimologia , Infecções por Bactérias Gram-Negativas/diagnóstico , Infecções por Bactérias Gram-Negativas/microbiologia , Técnicas de Diagnóstico Molecular/métodos , Reação em Cadeia da Polimerase/métodos , Reto/microbiologia , beta-Lactamases/análise , Proteínas de Bactérias/genética , Bactérias Gram-Negativas/isolamento & purificação , Humanos , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Espanha , Fatores de Tempo , Reino Unido , Estados Unidos , beta-Lactamases/genética
7.
Appl Radiat Isot ; 110: 193-199, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26829618

RESUMO

Hydrophobic adsorbents such as C18 and C30 were coated with PEG and subsequently used for the separation of Mo/Tc. The most effective resin for adsorbing PEG was the C18-U resin, which demonstrated a coating capacity of 97.6±2.8mg PEG per g of resin. The ability to adsorb pertechnetate was proportional to the amount of PEG coated on the hydrophobic resin. The [(99m)Tc]pertechnetate recovery during the separation of cyclotron produced (99m)Tc from (100)Mo was 91.8±0.3% (n=2). The resultant product met relevant USP monograph specifications.


Assuntos
Molibdênio/isolamento & purificação , Pertecnetato Tc 99m de Sódio/isolamento & purificação , Adsorção , Ciclotrons , Humanos , Interações Hidrofóbicas e Hidrofílicas , Isótopos/isolamento & purificação , Polietilenoglicóis , Radioisótopos/isolamento & purificação , Compostos Radiofarmacêuticos/isolamento & purificação , Resinas Sintéticas
8.
Physiol Meas ; 36(6): 1297-309, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26006739

RESUMO

Recent studies showed that regional pulmonary perfusion can be reliably estimated using electrical impedance tomography (EIT) with the aid of hypertonic saline based contrast enhancement. Building on these successful studies, we studied contrast EIT for pulmonary perfusion defect caused by an artificially induced pulmonary embolism (PE) in a large ovine model (N = 8, 78 ± 7.8 kg). Furthermore, the efficacy of a less invasive contrast bolus of 0.77 ml kg(-1) of NaCl 3% was compared with a more concentrated bolus of 0.13 ml kg(-1) of NaCl 20%. Prior to the injection of each contrast bolus injection, ventilation was turned off to provide a total of 40 to 45 s of apnoea. Each bolus of impedance contrast was injected through a catheter into the right atrium. Pulmonary embolisation was performed by balloon occlusion of part of the right branch of the pulmonary trunk. Four parameters representing the kinetics of the contrast dilution in the lung were evaluated for statistical differences between baseline and PE, including peak value, maximum uptake, maximum washout and area under the curve of the averaged contrast dilution curve in each lung. Furthermore, the right lung to left lung (R2L) ratio of each the aforementioned parameters were assessed. While all of the R2L ratios yielded significantly different means between baseline and PE, it can be concluded that the R2L ratios of area under the curve and peak value of the averaged contrast dilution curve are the most promising and reliable in assessing PE. It was also found that the efficacy of the two types of impedance contrasts were not significantly different in distinguishing PE from baseline in our model.


Assuntos
Embolia Pulmonar/diagnóstico , Embolia Pulmonar/fisiopatologia , Fluxo Sanguíneo Regional , Tomografia , Animais , Volume Sanguíneo , Impedância Elétrica , Masculino , Ovinos
9.
Artigo em Inglês | MEDLINE | ID: mdl-25570157

RESUMO

Increased myocardial structural heterogeneity in response to ischemic injury following myocardial infarction (MI) is purported as the mechanism of ventricular arrhythmogenesis. Current modalities for in vivo assessment of structural heterogeneity for identification of arrhythmogenic substrate are limited due to the complex nature of the structural microenvironment post-MI. We investigated the utility of in vivo bio-impedance spectroscopy (BIS) in a large post-infarct animal model for differentiation between normal and infarcted tissue. We also investigated the quantitative effects of adipose and collagen on BIS assessment of myocardium. The results indicate that the degree of myocardial injury following chronic post-infarction remodeling could be reliably quantified (performed in triplicates) using BIS. Furthermore, the presence of intramyocardial adipose tissue that develops in conjunction with collagen within the infarct zone had a greater and significant influence on BIS then collagen tissue alone. These preliminary results indicate a potential role of BIS for quantitative assessment and characterization of complex arrhythmogenic substrates in ischemic cardiomyopathy.


Assuntos
Espectroscopia Dielétrica/métodos , Coração/fisiopatologia , Infarto do Miocárdio/fisiopatologia , Animais , Modelos Animais de Doenças , Isquemia Miocárdica , Processamento de Sinais Assistido por Computador
10.
Physiol Meas ; 34(9): 991-1012, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23945151

RESUMO

We present an innovative bio-potential front-end capable of recording true unipolar ECG leads for the first time without making use of the Wilson central terminal. In addition to the convenience in applications such as continuous monitoring and rapid diagnosis, the information in unipolar recordings may yield unique diagnostic information as it avoids the need to essentially subtract data or make use of the averaging effect imposed from the Wilson central terminal. The system also allows direct, real-time software calculation of signals corresponding to standard ECG leads which achieve correlations in excess of 92% with a gold standard ECG during a parallel in vivo recording. In addition, the implemented circuit is wideband (0.05-1000 Hz), compatible with standard (Ag/AgCl) bio-potential electrodes, and dry (paste-less) textile electrodes. The circuit is also low power, requiring less than 50 mW (when powered at 12 V) per standard ECG lead (two channels required). It is therefore well suited for wearable, long-term applications.


Assuntos
Eletrocardiografia/métodos , Adulto , Cateterismo Cardíaco , Eletrocardiografia/instrumentação , Eletrodos , Humanos , Masculino
11.
J Clin Microbiol ; 51(6): 1948-50, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23554195

RESUMO

The NucliSENS EasyQ KPC assay (bioMérieux SA, Marcy l'Etoile, France) was compared with a routinely used phenotypic method for detection of Enterobacteriaceae producing Klebsiella pneumoniae carbapenemase (KPC)-type carbapenemases, using 806 stool samples and rectal swabs. Compared with the phenotypic method, the EasyQ KPC assay had a sensitivity and specificity of 93.3% and 99.0%, respectively, in this setting, with diverse KPC producers not limited to ST258 Klebsiella pneumoniae.


Assuntos
Proteínas de Bactérias/análise , Proteínas de Bactérias/genética , Infecções por Enterobacteriaceae/microbiologia , Enterobacteriaceae/enzimologia , Enterobacteriaceae/isolamento & purificação , beta-Lactamases/análise , beta-Lactamases/genética , Fezes/microbiologia , França , Humanos , Reto/microbiologia , Sensibilidade e Especificidade
12.
Curr Oncol ; 20(2): 104-10, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23559873

RESUMO

PURPOSE: The objective of the present study was to analyze, with relatively high sensitivity and specificity, uptake properties of [(11)C]-choline in prostate cancer patients by means of positron-emission tomography (pet)/computed tomography (ct) imaging using objectively defined pet parameters to test for statistically significant changes before, during, and after external-beam radiation therapy (ebrt) and to identify the time points at which the changes occur. METHODS: The study enrolled 11 patients with intermediate-risk prostate cancer treated with ebrt, who were followed for up to 12 months after ebrt. The [(11)C]-choline pet scans were performed before treatment (baseline); at weeks 4 and 8 of ebrt; and at 1, 2, 3, 6, and 12 months after ebrt. RESULTS: Analysis of [(11)C]-choline uptake in prostate tissue before treatment resulted in a maximum standardized uptake value (suvmax) of 4.0 ± 0.4 (n = 11) at 40 minutes after injection. During week 8 of ebrt, the suvmax declined to 2.9 ± 0.1 (n = 10, p < 0.05). At 2 and 12 months after ebrt, suvmax values were 2.3 ± 0.3 (n = 10, p < 0.01) and 2.2 ± 0.2 (n = 11, p < 0.001) respectively, indicating that, after ebrt, maximum radiotracer uptake in the prostate was significantly reduced. Similar effects were observed when analyzing the tumour:muscle ratio (tmr). The tmr declined from 7.4 ± 0.6 (n = 11) before ebrt to 6.1 ± 0.4 (n = 11, nonsignificant) during week 8 of ebrt, to 5.6 ± 0.03 (n = 11, p < 0.05) at 2 months after ebrt, and to 4.4 ± 0.4 (n = 11, p < 0.001) at 12 months after ebrt. CONCLUSIONS: Our study demonstrated that intraprostatic [(11)C]-choline uptake in the 11 analyzed prostate cancer patients significantly declined during and after ebrt. The pet parameters SUVmax and tmr also declined significantly. These effects can be detected during radiation therapy and up to 1 year after therapy. The prognostic value of these early and statistically significant changes in intraprostatic [(11)C]-choline pet avidity during and after ebrt are not yet established. Future studies are indicated to correlate changes in [(11)C]-choline uptake parameters with long-term biochemical recurrence to further evaluate [(11)C]-choline pet changes as a possible, but currently unproven, biomarker of response.

14.
Technol Cancer Res Treat ; 12(1): 79-90, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22974332

RESUMO

The physical properties of I-131 may be suboptimal for the delivery of therapeutic radiation to bone marrow metastases, which are common in the natural history of neuroblastoma. In vitro and preliminary clinical studies have implied improved efficacy of I-125 relative to I-131 in certain clinical situations, although areas of uncertainty remain regarding intratumoral dosimetry. This prompted our study using human neuroblastoma multicellular spheroids as a model of metastasis. 3D dose calculations were made using voxel-based Medical Internal Radiation Dosimetry (MIRD) and dose-point-kernel (DPK) techniques. Dose distributions for I-131 and I-125 labeled mIBG were calculated for spheroids (metastases) of various sizes from 0.01 cm to 3 cm diameter, and the relative dose delivered to the tumors was compared for the same limiting dose to the bone marrow. Based on the same data, arguments were advanced based upon the principles of tumor control probability (TCP) to emphasize the potential theoretical utility of I-125 over I-131 in specific clinical situations. I-125-mIBG can deliver a higher and more uniform dose to tumors compared to I-131 mIBG without increasing the dose to the bone marrow. Depending on the tumor size and biological half-life, the relative dose to tumors of less than 1 mm diameter can increase several-fold. TCP calculations indicate that tumor control increases with increasing administered activity, and that I-125 is more effective than I-131 for tumor diameters of 0.01 cm or less. This study suggests that I-125-mIBG is dosimetrically superior to I-131-mIBG therapy for small bone marrow metastases from neuroblastoma. It is logical to consider adding I-125-mIBG to I-131-mIBG in multi-modality therapy as these two isotopes could be complementary in terms of their cumulative dosimetry.


Assuntos
3-Iodobenzilguanidina/metabolismo , Radioisótopos do Iodo/metabolismo , Modelos Biológicos , Neuroblastoma/patologia , Neuroblastoma/radioterapia , Algoritmos , Simulação por Computador , Metástase Neoplásica , Radiometria
15.
Comput Biol Med ; 42(11): 1122-32, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23017828

RESUMO

The conductivity distribution around the thorax is altered during the cardiac cycle due to the blood perfusion, heart contraction and lung inflation. Previous studies showed that these bio-impedance changes are appropriate for non-invasive cardiac function imaging using Electrical Impedance Tomography (EIT) techniques. However, the spatial resolution is presently low. One of the main obstacles in cardiac imaging at the heart location is the large impedance variation of the lungs by respiration and muscles on the dorsal and posterior side of the body. In critical care units there is a potential to insert an internal electrode inside the esophagus directly behind the heart in the same plane of the external electrodes. The aim of the present study is to evaluate different current stimulation and measurement patterns with both external and internal electrodes. Analysis is performed with planar arrangement of 16 electrodes for a simulated 3D cylindrical tank and pig thorax model. In our study we evaluated current injection patterns consisting of adjacent, diagonal, trigonometric, and radial to the internal electrode. The performance of these arrangements was assessed using quantitative methods based on distinguishability, sensitivity and GREIT (Graz consensus Reconstruction algorithm for Electrical Impedance Tomography). Our evaluation shows that an internal electrode configuration based on the trigonometric injection patterns has better performance and improves pixel intensity of the small conductivity changes related to heart near 1.7 times in reconstructed images and also shows more stability with different levels of added noise. For the internal electrode, when we combined radial or adjacent injection with trigonometric injection pattern, we found an improvement in amplitude response. However, the combination of diagonal with trigonometric injection pattern deteriorated the shape deformation (correlation coefficient r=0.344) more than combination of radial and trigonometric injection (correlation coefficient r=0.836) for the perturbations in the area close to the center of the cylinder. We also find that trigonometric stimulation pattern performance is degraded in a realistic thorax model with anatomical asymmetry. For that reason we recommend using internal electrodes only for voltage measurements and as a reference electrode during trigonometric stimulation patterns in practical measurements.


Assuntos
Eletrodiagnóstico/instrumentação , Eletrodiagnóstico/métodos , Testes de Função Cardíaca/instrumentação , Testes de Função Cardíaca/métodos , Tomografia/instrumentação , Tomografia/métodos , Algoritmos , Animais , Condutividade Elétrica , Impedância Elétrica , Estimulação Elétrica , Eletrodos , Análise de Elementos Finitos , Processamento de Imagem Assistida por Computador/métodos , Modelos Teóricos , Processamento de Sinais Assistido por Computador , Suínos , Tórax/anatomia & histologia , Tórax/fisiologia
16.
J Perinatol ; 32(8): 639-41, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22842802

RESUMO

The diagnosis and management of a heterokaryotypic monochorionic pregnancy, in which one of twins had trisomy 13, is presented. Monozygosity and discordant karyotypes were confirmed by amniocentesis of both the sacs. Radiofrequency ablation of the trisomic twin was successfully performed at 18-weeks gestation and the pregnancy ended at term with the birth of a healthy girl who remains well on follow-up at 12 months of age. We reiterate the importance of early amniocentesis of both the sacs in the presence of discordant fetal abnormalities and consideration of selective fetal termination to optimise the outcome of heterokaryotypic monochorionic twin pregnancies.


Assuntos
Transtornos Cromossômicos/diagnóstico , Doenças em Gêmeos , Diagnóstico Pré-Natal , Trissomia/diagnóstico , Gêmeos Monozigóticos/genética , Adulto , Amniocentese , Ablação por Cateter , Transtornos Cromossômicos/terapia , Cromossomos Humanos Par 13 , Feminino , Aconselhamento Genético , Humanos , Cariotipagem , Gravidez , Síndrome da Trissomia do Cromossomo 13
17.
Appl Radiat Isot ; 70(8): 1685-90, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22750197

RESUMO

There is growing interest in the large scale cyclotron production of (99m)Tc via the (100)Mo(p,2n)(99m)Tc reaction. While the use and recycling of cyclotron-irradiated enriched molybdenum targets has been reported previously in the context of (94m)Tc production, to the best of our knowledge, previous recycling studies have been limited to the use of oxide targets. To facilitate reuse of high-power enriched (100)Mo targets, this work presents and evaluates a strategy for recycling of enriched metallic molybdenum. For the irradiated (100)Mo targets in this study, an overall metal to metal recovery of 87% is reported. Evaluation of "new" and "recycled" (100)Mo revealed no changes in the molybdenum isotopic composition (as measured via ICP-MS). For similar irradiation conditions of "new" and "recycled" (100)Mo, (i.e. target thicknesses, irradiation time, and energy), comparable levels of (94g)Tc, (95g)Tc, and (96g)Tc contaminants were observed. Comparable QC specifications (i.e. aluminum ion concentration, pH, and radiochemical purity) were also reported. We finally note that [(99m)Tc]-MDP images obtained by comparing MDP labelled with generator-based (99m)Tc vs. (99m)Tc obtained following the irradiation of recycled (100)Mo demonstrated comparable biodistribution. With the goal of producing large quantities of (99m)Tc, the proposed methodology demonstrates that efficient recycling of enriched metallic (100)Mo targets is feasible and effective.

18.
Int J Radiat Oncol Biol Phys ; 84(2): 437-42, 2012 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-22541957

RESUMO

PURPOSE: We report the results of a phase II study to determine the reproducibility of a submandibular salivary gland transfer (SGT) surgical technique for prevention of radiation (XRT)-induced xerostomia in a multi-institutional setting and to assess severity of xerostomia. METHODS AND MATERIALS: Eligible patients had surgery for primary, neck dissection, and SGT, followed by XRT, during which the transferred salivary gland was shielded. Intensity modulated radiation therapy, amifostine, and pilocarpine were not allowed, but postoperative chemotherapy was allowed. Each operation was reviewed by 2 reviewers and radiation by 1 reviewer. If 13 or more (of 43) were "not per protocol," then the technique would be considered not reproducible as per study design. The secondary endpoint was the rate of acute xerostomia, grade 2 or higher, and a rate of ≤ 51% was acceptable. RESULTS: Forty-four of the total 49 patients were analyzable: male (81.8%), oropharynx (63.6%), stage IV (61.4%), median age 56.5 years. SGT was "per protocol" or within acceptable variation in 34 patients (77.3%) and XRT in 79.5%. Nine patients (20.9%) developed grade 2 acute xerostomia; 2 had grade 0-1 xerostomia (4.7%) but started on amifostine/pilocarpine. Treatment for these 11 patients (25.6%) was considered a failure for the xerostomia endpoint. Thirteen patients died; median follow-up for 31 surviving patients was 2.9 years. Two-year overall and disease-free survival rates were 76.4% and 71.7%, respectively. CONCLUSIONS: The technique of submandibular SGT is reproducible in a multicenter setting. Seventy-four percent of patients were prevented from XRT-induced acute xerostomia.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Glândula Submandibular/cirurgia , Xerostomia/prevenção & controle , Adulto , Idoso , Antineoplásicos/uso terapêutico , Intervalo Livre de Doença , Feminino , Neoplasias de Cabeça e Pescoço/tratamento farmacológico , Neoplasias de Cabeça e Pescoço/mortalidade , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Lesões por Radiação , Radiografia , Recidiva , Reprodutibilidade dos Testes , Glândula Submandibular/diagnóstico por imagem , Xerostomia/classificação , Xerostomia/etiologia , Xerostomia/mortalidade
19.
Physiol Meas ; 33(5): 695-706, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22532291

RESUMO

Although electrical impedance tomography (EIT) for ventilation monitoring is on the verge of clinical trials, pulmonary perfusion imaging with EIT remains a challenge, especially in spontaneously breathing subjects. In anticipation of more research on this subject, we believe a thorough review is called for. In this paper, findings related to the physiological origins and electrical characteristics of this signal are summarized, highlighting properties that are particularly relevant to EIT. The perfusion impedance change signal is significantly smaller in amplitude compared with the changes due to ventilation. Therefore, the hardware used for this purpose must be more sensitive and more resilient to noise. In previous works, some signal- or image-processing methods have been required to separate these two signals. Three different techniques are reviewed in this paper, including the ECG-gating method, frequency-domain-filtering-based methods and a principal-component-analysis-based method. In addition, we review a number of experimental studies on both human and animal subjects that employed EIT for perfusion imaging, with promising results in the diagnosis of pulmonary embolism (PE) and pulmonary arterial hypertension as well as other potential applications. In our opinion, PE is most likely to become the main focus for perfusion EIT in the future, especially for heavily instrumented patients in the intensive care unit (ICU).


Assuntos
Pulmão/irrigação sanguínea , Pulmão/diagnóstico por imagem , Imagem de Perfusão/métodos , Tomografia/métodos , Animais , Impedância Elétrica , Humanos
20.
Physiol Meas ; 33(5): 767-86, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22531059

RESUMO

Imaging of acute stroke might be possible using multi-frequency electrical impedance tomography (MFEIT) but requires absolute or frequency difference imaging. Simple linear frequency difference reconstruction has been shown to be ineffective in imaging with a frequency-dependant background conductivity; this has been overcome with a weighted frequency difference approach with correction for the background but this has only been validated for a cylindrical and hemispherical tank. The feasibility of MFEIT for imaging of acute stroke in a realistic head geometry was examined by imaging a potato perturbation against a saline background and a carrot-saline frequency-dependant background conductivity, in a head-shaped tank with the UCLH Mk2.5 MFEIT system. Reconstruction was performed with time difference (TD), frequency difference (FD), FD adjacent (FDA), weighted FD (WFD) and weighted FDA (WFDA) linear algorithms. The perturbation in reconstructed images corresponded to the true position to <9.5% of image diameter with an image SNR of >5.4 for all algorithms in saline but only for TD, WFDA and WFD in the carrot-saline background. No reliable imaging was possible with FD and FDA. This indicates that the WFD approach is also effective for a realistic head geometry and supports its use for human imaging in the future.


Assuntos
Algoritmos , Cabeça , Processamento de Imagem Assistida por Computador/métodos , Acidente Vascular Cerebral/diagnóstico , Tomografia/métodos , Impedância Elétrica , Humanos , Fatores de Tempo , Tomografia/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA