Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Am Audiol Soc ; 3(1): 6-9, 1977.
Artigo em Inglês | MEDLINE | ID: mdl-893203

RESUMO

The filter effect of venting an earmold was evaluated by measuring the coupler-acoustic and threshold responses to open versus closed earmolds. In the coupler-acoustic technique the effect of venting was determined by measuring the output of the experimental earmolds seated on a modified 2-cc coupler with a specified signal impressed upon the earphone. The real ear threshold technique called for the determination of threshold by five listeners for the same earphone-earmold system. The data indicated that the difference between the coupler and threshold measures were of the same order of magnitude as the difference seen by other investigators reporting coupler and real ear-probe tube microphone measures. It was concluded that the threshold technique provides the same general description of the effects of venting an earmold as does the probe tube technique and should thus provide a useful method for determination of the filter effects produced by the venting of an earmold.


Assuntos
Auxiliares de Audição/instrumentação , Limiar Auditivo , Estudos de Avaliação como Assunto , Humanos
2.
Audiology ; 14(3): 259-67, 1975.
Artigo em Inglês | MEDLINE | ID: mdl-1131129

RESUMO

The frequency response and loudness reduction characteristics of earmolds with variable venting valves (VVV) were investigated. Both side-branch and laterally vented earmolds were employed. Sound pressures were measured at 44 frequencies from 100 to 4 000 HZ in a modified HA-2 coupler with the VVV in four stages of opening: closed; 1/3 open; 2/3 open and 3/3 open. The effect of venting is primarily in the low frequencies. Little or no reduction in intensity is observed in the 'speech frequency' range and a modest amount is noted in the higher frequencies. The side-branch vented earmolds were more effective than the laterally vented earmolds. Calculated loudness reductions in phons were small. The effectiveness of the VVV, whether assessed by the frequency response or loudness reduction characteristics, is achieved within the first 1/3 of opening: further opening has little effect. The utility of the VVV, especially to the geriatric hearing aid user, is questionable.


Assuntos
Auxiliares de Audição , Auxiliares de Audição/instrumentação , Auxiliares de Audição/métodos , Testes Auditivos , Humanos , Ruído