Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 207
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-39182799

RESUMO

Mechanical circulatory support devices have profoundly transformed the management of severe cardiothoracic disorders. While heart transplantation is the gold standard therapy for end-stage heart disease, long-term mechanical support devices are a viable alternative for those ineligible and/or those awaiting organ availability. Major technological advancements were made over first 5 decades of development, resulting in improved durability and survival with reduced adverse events. However, gains have tapered recently for various complications (e.g., internal bleeding, multisystem organ failure), which collectively represent a significant proportion of disability and/or mortality. Further, in light of mature ventricular assist devices failing during clinical trials or even after clinical approval (class I withdrawals), it is timely to consider: Are our preclinical assessment protocols vital in the design and development of mechanical circulatory support devices, providing a realistic and reliable profile of future clinical performance? This commentary explores this question and analyses development pathways through the lens of the various disciplines involved in the preclinical assessment of mechanical circulatory support technologies: Limitations in approaches to benchtop blood testing, computational design and simulation, and animal testing are discussed as likely contributors to some of the common hemocompatibility-related adverse events (HRAEs). While it is acknowledged that some shortcomings are pragmatic in nature, possible solutions are presented that will only be realized through truly transdisciplinary and open approaches that challenge the current nature of medical device development. We suggest that these can and must be overcome to diminish HRAEs and will potentially demarcate the fourth generation of cardiac assist devices.

2.
Intern Med J ; 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39087843

RESUMO

Chronic thromboembolic pulmonary disease (CTEPD) with or without pulmonary hypertension (PH) is an important potential consequence of venous thromboembolic disease. Untreated CTEPD with pulmonary hypertension (CTEPH) is associated with high rates of morbidity and mortality. Several treatment options are now available for patients with CTEPD and CTEPH, including pulmonary endarterectomy (PEA), balloon pulmonary angioplasty, medical therapy or a combination of therapies. Choice of treatment depends on the location of the thromboembolic disease burden, presence and severity of PH and patient factors, including frailty, parenchymal lung disease and other comorbidities. PEA is a complex surgery that can result in excellent outcomes and resolution of disease, but also comes with the risk of serious perioperative complications. This manuscript examines the history of PEA and its place in Australasia, and reports on outcomes from the main Australasian CTEPH expert centre. It provides a summary of up-to-date guidance on how PEA should be utilised in the overall management of these patients and describes opportunities and challenges for the future diagnosis and management of this disease, particularly in the Australasian setting.

3.
Ann Biomed Eng ; 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39014052

RESUMO

Heart failure with preserved ejection fraction (HFpEF) constitutes approximately 50% of heart failure (HF) cases, and encompasses different phenotypes. Among these, most patients with HFpEF exhibit structural heart changes, often with smaller left ventricular cavities, which pose challenges for utilizing ventricular assist devices (VADs). A left atrial to aortic (LA-Ao) VAD configuration could address these challenges, potentially enhancing patient quality of life by lowering elevated mean left atrial pressure (MLAP). This study assessed the anatomical compatibility and left atrial unloading capacity using a simulated VAD-supported HFpEF patient. A HeartMate3-supported HFpEF patient in an LA-Ao configuration was simulated using a cardiovascular simulator. Hemodynamic parameters were recorded during rest and exercise at seven pump flow rates. Computed tomography scans of 14 HFpEF (NYHA II-III) and six heart failure with reduced ejection fraction patients were analysed for anatomical comparisons. HFpEF models were independently assessed for virtual anatomical fit with the HM3 in the LA-Ao configuration. Baseline MLAP was reduced from 15 to 11 mmHg with the addition of 1 L/min HM3 support in the rest condition. In an exercise simulation, 6 L/min of HM3 support was required to reduce the MLAP from 29 to 16 mmHg. The HM3 successfully accommodated six HFpEF patients without causing interference with other cardiac structures, whereas it caused impingement ranging from 4 to 14 mm in the remaining patients. This study demonstrated that the HM3 in an LA-Ao configuration may be suitable for unloading the left atrium and relieving pulmonary congestion in some HFpEF patients where size-related limitations can be addressed through pre-surgical anatomical fit analysis.

4.
JACC Clin Electrophysiol ; 10(7 Pt 2): 1711-1719, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39084745

RESUMO

BACKGROUND: Although postoperative atrial fibrillation (POAF) frequently occurs early after cardiac surgery, there is a paucity of data evaluating predictors and timing of late atrial fibrillation (AF) recurrence. OBJECTIVES: The authors sought to evaluate predictors of late AF recurrence in patients undergoing cardiac surgery. METHODS: We retrospectively reviewed cardiac surgery patients from 2010 to 2018 with no preoperative diagnosis of AF or atrial flutter. We recorded incidence and timing of late AF recurrence, defined as occurring ≥12 months following surgery. RESULTS: 1,031 patients were included (mean age at surgery 64 ± 12 years, 74% male). Early POAF was recorded in 445 patients (43%). POAF was usually transient, with total AF duration <48 hours in 72% and reversion to sinus rhythm at discharge in 91%. At 4.7 ± 2.4 years follow-up, late AF occurred in 139 patients (14%). Median time to AF recurrence was 4.4 years post-surgery (Q1-Q3: 2.6-6.2 years). Late AF was significantly more likely among patients with early POAF than those without (23% vs 6%; P < 0.001), with highest incidence (38%) in those with POAF duration >48 hours. In a multivariable analysis, early POAF duration >48 hours was a significant predictor of late AF recurrence (HR: 5.9). Surgery type and CHA2DS2-VASc score were not predictive of late AF events. CONCLUSIONS: Post-operative AF episodes of duration ≥48 hours predict recurrent AF episodes over long-term follow-up after cardiac surgery. Implications for arrhythmia surveillance and anticoagulation in patients with longer duration POAF episodes require further study.


Assuntos
Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Complicações Pós-Operatórias , Recidiva , Humanos , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/etiologia , Masculino , Feminino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Estudos Retrospectivos , Idoso , Complicações Pós-Operatórias/epidemiologia , Fatores de Risco , Incidência , Fatores de Tempo
5.
Anesthesiology ; 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38904693

RESUMO

BACKGROUND: High-dose corticosteroids have been used to attenuate the inflammatory response to cardiac surgery and cardiopulmonary bypass, but patient outcome benefits remain unclear. Our primary aim was to determine whether using dexamethasone was superior to not using dexamethasone to increase the number of home days in the first 30 days after cardiac surgery. Our secondary aim was to evaluate efficiency, value and impact of the novel trial design. METHODS: This pragmatic, international trial incorporating a prerandomized consent design favoring local practice enrolled patients undergoing cardiac surgery across 7 hospitals in Australia and The Netherlands. Patients were randomly assigned to dexamethasone, 1 mg/kg, or not (control). The primary outcome was the number of days alive and at home up to 30 days after surgery ("home days"). Secondary outcomes included prolonged mechanical ventilation (>48 h), sepsis, renal failure, myocardial infarction, stroke and death. RESULTS: Of 2093 patients assessed for eligibility, 1951 were randomized (median age 63 years, 80% male). The median number of home days was 23.0 (IQR, 20.1 to 24.1) in the dexamethasone group and 23.1 (IQR, 20.1 to 24.6) in the no dexamethasone group; median difference 0.1 (95% CI, -0.3 to 0.5), P=0.66. The rates of prolonged mechanical ventilation, RR 0.72 (95% CI, 0.48 to 1.08), sepsis, RR 1.02 (95% CI, 0.57 to 1.82), renal failure, RR 0.94 (95% CI, 0.80 to 1.12), myocardial infarction, RR 1.20 (95% CI, 0.30 to 4.82), stroke, RR 1.06 (95% CI, 0.54 to 2.08), and death, RR 0.72 (95% CI, 0.22 to 2.35), were comparable between groups (all P>0.10). Dexamethasone reduced intensive care unit stay, median 29 (IQR, 22 to 50) h vs. 43 (24 to 72) h, P=0.004. Our novel trial design was highly efficient (89.3% enrolment). CONCLUSIONS: Among patients undergoing cardiac surgery, high-dose dexamethasone decreased intensive care unit stay but did not increase the number of home days after surgery.

6.
Eur J Clin Invest ; : e14259, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38845111

RESUMO

BACKGROUND: The commonest echocardiographic measurement, left ventricular ejection fraction, can not necessarily predict mortality of recipients following heart transplantation potentially due to afterload dependency. Afterload-independent left ventricular stroke work index (LVSWI) is alternatively recommended by the current guideline; however, pulmonary artery catheters are rarely inserted in organ donors in most jurisdictions. We propose a novel non-invasive echocardiographic parameter, Pressure-Strain Product (PSP), as a potential surrogate of catheter-based LVSWI. This study aimed to investigate if PSP could correlate with catheter-based LVSWI in an ovine model of brain stem death (BSD) donors. The association between PSP and myocardial mitochondrial function in the post-transplant hearts was also evaluated. METHODS: Thirty-one female sheep (weight 47 ± 5 kg) were divided into two groups; BSD (n = 15), and sham neurologic injury (n = 16). Echocardiographic parameters including global circumferential strain (GCS) and global radial strain (GRS) and pulmonary artery catheter-based LVSWI were simultaneously measured at 8-timepoints during 24-h observation. PSP was calculated as a product of GCS or GRS, and mean arterial pressure for PSPcirc or PSPrad, respectively. Myocardial mitochondrial function was evaluated following 6-h observation after heart transplantation. RESULTS: In BSD donor hearts, PSPcirc (n = 96, rho = .547, p < .001) showed the best correlation with LVSWI among other echocardiographic parameters. PSPcirc returned AUC of .825 to distinguish higher values of cardiomyocyte mitochondrial function (cut-off point; mean value of complex 1,2 O2 Flux) in post-transplant hearts, which was greater than other echocardiographic parameters. CONCLUSIONS: PSPcirc could be used as a surrogate of catheter-based LVSWI reflecting mitochondrial function.

7.
ASAIO J ; 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38833540

RESUMO

Impaired primary hemostasis and dysregulated angiogenesis, known as a two-hit hypothesis, are associated with gastrointestinal (GI) bleeding in patients with continuous-flow left ventricular assist devices (CF-LVADs). Exercise is known to influence hemostasis and angiogenesis in healthy individuals; however, little is known about the effect in patients with CF-LVADs. The objective of this prospective observational study was to determine whether acute exercise modulates two-hit hypothesis mediators associated with GI bleeding in patients with a CF-LVAD. Twenty-two patients with CF-LVADs performed acute exercise either on a cycle ergometer for approximately 10 minutes or on a treadmill for 30 minutes. Blood samples were taken pre- and post-exercise to analyze hemostatic and angiogenic biomarkers. Acute exercise resulted in an increased platelet count (p < 0.00001) and platelet function (induced by adenosine diphosphate, p = 0.0087; TRAP-6, p = 0.0005; ristocetin, p = 0.0009). Additionally, high-molecular-weight vWF multimers (p < 0.00001), vWF collagen-binding activity (p = 0.0012), factor VIII (p = 0.034), angiopoietin-1 (p = 0.0026), and vascular endothelial growth factor (p = 0.0041) all increased after acute exercise. This pilot work demonstrates that acute exercise modulated two-hit hypothesis mediators associated with GI bleeding in patients with CF-LVADs.

10.
Heart Lung Circ ; 33(8): 1184-1192, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38609798

RESUMO

BACKGROUND: Adult congenital heart disease (ACHD) services increasingly encounter heart failure (HF) in the ageing ACHD population. Optimal timing of referral for heart transplant (HTx) evaluation in this heterogeneous population is complex and ill-defined. We aim to outline the characteristics and outcomes of ACHD patients referred for HTx from a large Australian ACHD centre. METHOD: Retrospective review of ACHD patients referred for HTx from a primary ACHD centre (1992-2021). Database analysis of patient demographics, characteristics, wait-listing, and transplantation outcomes was performed. RESULTS: A total of 45 patients (mean age 37±9.9 years old; 69% male) were referred for HTx with a mean follow-up of 5.9±6.3 years. Of these, 22 of 45 (49%) were listed and transplanted, including one heart-lung transplant. The commonest diagnosis was dextro-transposition of the great arteries (13/45, 29%). Most patients, 33 of 45 (73.3%) had undergone at least one cardiac surgery in childhood. Indications for HTx referral included HF in 34 of 45 (75%), followed by pulmonary hypertension in 7 of 45 (11%). Median transplant wait-list time was 145 days (interquartile range, 112-256). Of the 23 patients not wait-listed, the reasons included clinical stability in 13 of 45 (29%), psychosocial factors in 2 of 45 (4.4%) and prohibitive surgical risk, including multiorgan dysfunction, in 8 of 45 (17.7%). Transplant was of a single organ in most, 21 of 22 (95.5%). Overall mortality was 5 of 22 (22.7%) in those after HTx, and 14 of 23 (60.9%) in those not listed (p=0.0156). CONCLUSIONS: Increasingly, ACHD patients demonstrate the need for advanced HF treatments. HTx decision-making is complex, and increased mortality is seen in those not wait-listed. Ultimately, the referral of ACHD patients for HTx is underpinned by local decision-making and experience, wait-list times and outcomes.


Assuntos
Cardiopatias Congênitas , Transplante de Coração , Encaminhamento e Consulta , Listas de Espera , Humanos , Masculino , Feminino , Cardiopatias Congênitas/cirurgia , Adulto , Estudos Retrospectivos , Seguimentos , Insuficiência Cardíaca/cirurgia , Taxa de Sobrevida/tendências , Austrália/epidemiologia , Pessoa de Meia-Idade
11.
Artif Organs ; 48(6): 655-664, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38459775

RESUMO

OBJECTIVES: Right ventricular failure following implantation of a durable left ventricular assist device (LVAD) is a major driver of mortality. Reported survival following biventricular (BiVAD) or total artificial heart (TAH) implantation remains substantially inferior to LVAD alone. We report our outcomes with LVAD and BiVAD HeartMate 3 (HM3). METHODS: Consecutive patients undergoing implantation of an HM3 LVAD between November 2014 and December 2021, at The Alfred, Australia were included in the study. Comparison was made between the BiVAD and LVAD alone groups. RESULTS: A total of 86 patients, 65 patients with LVAD alone and 21 in a BiVAD configuration underwent implantation. The median age of the LVAD and BiVAD groups was 56 years (Interquartile range 46-62) and 49 years (Interquartile range 37-55), respectively. By 4 years after implantation, 54% of LVAD patients and 43% of BiVAD patients had undergone cardiac transplantation. The incidence of stroke in the entire experience was 3.5% and pump thrombosis 5% (all in the RVAD). There were 14 deaths in the LVAD group and 1 in the BiVAD group. The actuarial survival for LVAD patients at 1 year was 85% and BiVAD patients at 1 year was 95%. CONCLUSIONS: The application of HM 3 BiVAD support in selected patients appears to offer a satisfactory solution to patients requiring biventricular support.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Pessoa de Meia-Idade , Masculino , Feminino , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Adulto , Estudos Retrospectivos , Resultado do Tratamento , Transplante de Coração/métodos , Austrália/epidemiologia , Implantação de Prótese/instrumentação , Implantação de Prótese/efeitos adversos , Implantação de Prótese/métodos
12.
Ann Biomed Eng ; 52(6): 1604-1616, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38418690

RESUMO

Left ventricular assist devices (LVADs) have been used off-label as long-term support of the right heart due to the lack of a clinically approved durable right VAD (RVAD). Whilst various techniques to reduce RVAD inflow cannula protrusion have been described, the implication of the protrusion length on right heart blood flow and subsequent risk of thrombosis remains poorly understood. This study investigates the influence of RVAD diaphragmatic cannulation length on right ventricular thrombosis risk using a patient-specific right ventricle in silico model validated with particle image velocimetry. Four cannulation lengths (5, 10, 15 and 25 mm) were evaluated in a one-way fluid-structure interaction simulation with boundary conditions generated from a lumped parameter model, simulating a biventricular supported condition. Simulation results demonstrated that the 25-mm cannulation length exhibited a lower thrombosis risk compared to 5-, 10- and 15-mm cannulation lengths due to improved flow energy distribution (25.2%, 24.4% and 17.8% increased), reduced stagnation volume (72%, 68% and 49% reduction), better washout rate (13.0%, 11.6% and 9.1% faster) and lower blood residence time (6% reduction). In the simulated scenario, our findings suggest that a longer RVAD diaphragmatic cannulation length may be beneficial in lowering thrombosis risk; however, further clinical studies are warranted.


Assuntos
Cateterismo , Simulação por Computador , Ventrículos do Coração , Coração Auxiliar , Modelos Cardiovasculares , Trombose , Humanos , Ventrículos do Coração/fisiopatologia
13.
J Cardiol ; 84(4): 239-245, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38354768

RESUMO

BACKGROUND: Hyperlactatemia (HL) is a common phenomenon after cardiac surgery which is related to tissue hypoperfusion and hypoxia and associated with poor outcomes. It is also often seen in the postoperative period after orthotopic heart transplantation (OHTx), but the association between HL and outcomes after OHTx is not well known. We evaluated the incidence and outcome of HL after OHTx. METHODS: This was a retrospective study of 209 patients who underwent OHTx between January 2011 and December 2020. Patients were classified into 3 groups according to their peak lactate levels within the first 72 h postoperatively: group 1, normal to mild hyperlactatemia (<5 mmol/L, n = 42); group 2, moderate hyperlactatemia (5-10 mmol/L, n = 110); and group 3, severe hyperlactatemia (>10 mmol/L, n = 57). The primary composite endpoint was all-cause mortality or postoperative initiation of veno-arterial extracorporeal membrane oxygenation (VA ECMO) within 30 days. Secondary endpoints included duration of mechanical ventilation, intensive care unit length of stay, and hospital length of stay. RESULTS: Patients with higher postoperative peak lactate levels were more commonly transplanted from left ventricular assist device support (33.3 % vs 50.9 % vs 64.9, p < 0.01) and had longer cardiopulmonary bypass time [127 min (109-148) vs 141 min (116-186) vs 153 min (127-182), p = 0.02]. Composite primary endpoint was met in 18 patients (8.6 %) and was significantly more common in patients with higher postoperative peak lactate levels (0.0 % vs 6.4 % vs 19.3 %, p < 0.01). CONCLUSIONS: Severe hyperlactatemia following orthotopic heart transplant was associated with an increased risk of post-transplant VA ECMO initiation and mortality at 30 days.


Assuntos
Transplante de Coração , Hiperlactatemia , Complicações Pós-Operatórias , Humanos , Transplante de Coração/efeitos adversos , Hiperlactatemia/etiologia , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Adulto , Oxigenação por Membrana Extracorpórea , Ácido Láctico/sangue , Tempo de Internação , Incidência , Respiração Artificial
14.
J Heart Lung Transplant ; 43(3): 485-495, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37918701

RESUMO

BACKGROUND: Cold static storage preservation of donor hearts for periods longer than 4 hours increases the risk of primary graft dysfunction (PGD). The aim of the study was to determine if hypothermic oxygenated perfusion (HOPE) could safely prolong the preservation time of donor hearts. METHODS: We conducted a nonrandomized, single arm, multicenter investigation of the effect of HOPE using the XVIVO Heart Preservation System on donor hearts with a projected preservation time of 6 to 8 hours on 30-day recipient survival and allograft function post-transplant. Each center completed 1 or 2 short preservation time followed by long preservation time cases. PGD was classified as occurring in the first 24 hours after transplantation or secondary graft dysfunction (SGD) occurring at any time with a clearly defined cause. Trial survival was compared with a comparator group based on data from the International Society of Heart and Lung Transplantation (ISHLT) Registry. RESULTS: We performed heart transplants using 7 short and 29 long preservation time donor hearts placed on the HOPE system. The mean preservation time for the long preservation time cases was 414 minutes, the longest being 8 hours and 47 minutes. There was 100% survival at 30 days. One long preservation time recipient developed PGD, and 1 developed SGD. One short preservation time patient developed SGD. Thirty day survival was superior to the ISHLT comparator group despite substantially longer preservation times in the trial patients. CONCLUSIONS: HOPE provides effective preservation out to preservation times of nearly 9 hours allowing retrieval from remote geographic locations.


Assuntos
Transplante de Coração , Doadores de Tecidos , Humanos , Austrália/epidemiologia , Sobrevivência de Enxerto , Nova Zelândia , Preservação de Órgãos/métodos , Perfusão/métodos
15.
J Med Econ ; 27(1): 62-68, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38084737

RESUMO

BACKGROUND: VAD therapy has revolutionized the treatment of end-stage heart failure, but infections remain an important complication. The objective of this study was to characterize the clinical and economic impacts of VAD-specific infections. METHODS: A retrospective analysis of a United States claims database identified members ≥ 18 years with a claim for a VAD implant procedure, at least 6 months of pre-implant baseline data, and 12 months of follow-up between 1 June 2016 and 31 December 2019. Cumulative incidence of infection was calculated. Infection and non-infection cohorts were compared regarding mortality, healthcare utilization, and total cost. Regression models were used to identify risk factors associated with infections and mortality. RESULTS: A total of 2,259 patients with a VAD implant were included, with 369 experiencing infection (12-month cumulative incidence 16.1%). Patients with infection were 2.1 times more likely to die (p < 0.001, 95% CI [1.5-2.9]). The mean 12-month total cost per US patient was $354,339 for the non-infection cohort and $397,546 for the infection cohort, a difference of $43,207 (p < 0.0001). CONCLUSIONS: VAD infections were associated with higher mortality, more healthcare utilization, and higher total cost. Strategies to minimize VAD-specific infections could lead to improved clinical and economic outcomes.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Estados Unidos/epidemiologia , Estudos Retrospectivos , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Revisão da Utilização de Seguros , Fatores de Risco , Resultado do Tratamento
16.
Biofilm ; 6: 100162, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-37941804

RESUMO

Background: Recurrent vulvovaginal candidiasis (RVVC) is a recalcitrant medical condition that affects many women of reproductive age. The importance of biofilm formation by Candida in RVVC has been recently questioned. This study aimed to elucidate the fundamental growth modes of Candida in the vagina of patients with RVVC or sporadic vulvovaginal candidiasis (VVC) and to assess their roles in the persistence of RVVC. Methods: Vaginal tissues were sampled from twelve patients clinically and microbiologically diagnosed as RVVC or VVC at a post-antifungal-treatment and asymptomatic period. High-resolution scanning electron microscopy, fluorescence in situ hybridization in combination with Candida-specific 18S rRNA probes and viable fungal burden were used to qualitatively and quantitatively evaluate Candida growth in the human vagina. The presence of Candida biofilm extracellular polymeric substances was examined using confocal laser scanning microscopy and biopsy sections pre-stained with Concanavalin A. Histopathological analysis was carried out on infected vaginal tissues stained with hematoxylin and eosin. Lastly, the susceptibility of epithelium-associated Candida biofilms to fluconazole at the peak serum concentration was evaluated. Results: Candida species grew on the vaginal epithelium of RVVC patients as morphologically disparate biofilms including monolayers, microcolonies, and macro-colonies, in addition to sporadic adherent cells. Candida biofilm growth on the vaginal epithelium was associated with mild lymphocytic infiltration of the vaginal mucosa. These epithelium-based Candida biofilms presented an important characteristic contributing to the persistence of RVVC that is the high tolerance to fluconazole. Conclusions: In summary, our study provides direct evidence to support the presence of Candida biofilms in RVVC and an important role of biofilm formation in disease persistence.

17.
EClinicalMedicine ; 66: 102320, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38024476

RESUMO

Heart failure imposes a significant burden on all health care systems and has a 5-year mortality of 50%. Heart transplantation and ventricular assist device (VAD) implantation are the definitive therapies for end stage heart disease, although transplantation appears to offer superior long-term survival and quality of life over VAD implantation. Transplantation is limited by a shortage in donor hearts, resulting in considerable waiting list mortality. Donation after circulatory determination of death (DCD) offers a significant uplift in the number of donors for heart transplantation. The outcomes both from the UK and internationally have been exciting, with outcomes at least as good as conventional donation after brain death (DBD) transplantation. Currently, DCD hearts are reperfused using ex-situ machine perfusion (ESMP). Whilst ESMP has enabled the development of DCD transplantation, it comes at significant cost, with the per run cost of approximately GBP £90,000. In-situ perfusion of the heart, otherwise known as thoraco-abdominal normothermic regional perfusion (taNRP) is cheaper, but there are ethical concerns regarding the potential to restore cerebral perfusion in the donor. We must determine whether there is any cerebral circulation during in-situ perfusion of the heart to ensure that it does not invalidate the diagnosis of death and potentially violate the dead donor rule. Besides this, there is a need for a randomised controlled trial to definitively determine whether taNRP offers any clinical advantages over ex-situ machine perfusion. This viewpoint article explores these issues in more detail.

19.
Front Cardiovasc Med ; 10: 1132786, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37265571

RESUMO

Introduction: Chymase is a highly destructive serine protease rapidly neutralized in the circulation by protease inhibitors. Here we test whether pericardial fluid (PCF) chymase activation and other inflammatory biomarkers determine intensive care unit length of stay, and explore mechanisms of chymase delivery by extracellular vesicles to the heart. Methods: PCF was collected from adult patients (17 on-pump; 13 off-pump) 4 h after cardiac surgery. Extracellular vesicles (EVs) containing chymase were injected into Sprague-Dawley rats to test for their ability to deliver chymase to the heart. Results: The mean intensive care unit (ICU) stay and mean total length of stay was 2.17 ± 3.8 days and 6.41 ± 1.3 days respectively. Chymase activity and 32 inflammatory markers did not differ in on-pump vs. off-pump cardiac surgery. Society of Thoracic Surgeons Predicted Risk of Morbidity and Mortality Score (STS-PROM), 4-hour post-surgery PCF chymase activity and C-X-C motif chemokine ligand 6 (CXCL6) were all independent predictors of ICU and total hospital length of stay by univariate analysis. Mass spectrometry of baseline PCF shows the presence of serine protease inhibitors that neutralize chymase activity. The compartmentalization of chymase within and on the surface of PCF EVs was visualized by immunogold labeling and transmission electron microscopy. A chymase inhibitor prevented EV chymase activity (0.28 fmol/mg/min vs. 14.14 fmol/mg/min). Intravenous injection of PCF EVs obtained 24 h after surgery into Sprague Dawley rats shows diffuse human chymase uptake in the heart with extensive cardiomyocyte damage 4 h after injection. Discussion: Early postoperative PCF chymase activation underscores its potential role in cardiac damage soon after on- or off-pump cardiac surgery. In addition, chymase in extracellular vesicles provides a protected delivery mechanism from neutralization by circulating serine protease inhibitors.

20.
Biofilm ; 5: 100124, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37153749

RESUMO

Objectives: Driveline infections are a major complication of ventricular assist device (VAD) therapy. A newly introduced Carbothane driveline has preliminarily demonstrated anti-infective potential against driveline infections. This study aimed to comprehensively assess the anti-biofilm capability of the Carbothane driveline and explore its physicochemical characteristics. Methods: We assessed the Carbothane driveline against biofilm formation of leading microorganisms causing VAD driveline infections, including Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa and Candida albicans, using novel in vitro biofilm assays mimicking different infection micro-environments. The importance of physicochemical properties of the Carbothane driveline in microorganism-device interactions were analyzed, particularly focusing on the surface chemistry. The role of micro-gaps in driveline tunnels on biofilm migration was also examined. Results: All organisms were able to attach to the smooth and velour sections of the Carbothane driveline. Early microbial adherence, at least for S. aureus and S. epidermidis, did not proceed to the formation of mature biofilms in a drip-flow biofilm reactor mimicking the driveline exit site environment. The presence of a driveline tunnel however, promoted staphylococcal biofilm formation on the Carbothane driveline. Physicochemical analysis of the Carbothane driveline revealed surface characteristics that may have contributed to its anti-biofilm activity, such as the aliphatic nature of its surface. The presence of micro-gaps in the tunnel facilitated biofilm migration of the studied bacterial species. Conclusion: This study provides experimental evidence to support the anti-biofilm activity of the Carbothane driveline and uncovered specific physicochemical features that may explain its ability to inhibit biofilm formation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA