Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
3.
Innovations (Phila) ; 18(6): 565-573, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38013234

RESUMO

OBJECTIVE: A right minithoracotomy (RMT) is a minimally invasive surgical approach that has been increasingly performed for the concomitant Cox maze IV procedure (CMP) and mitral valve surgery (MVS). Little is known regarding whether long-term rhythm and survival outcomes are affected by the RMT as compared with the traditional median sternotomy (MS) approach. METHODS: Between April 2004 and April 2021, 377 patients underwent the concomitant CMP and MVS, of whom 38% had RMT. Propensity score matching yielded 116 pairs. Freedom from atrial tachyarrhythmias (ATA) was assessed with prolonged monitoring annually for 8 years. Survival, rhythm, and perioperative outcomes were compared. RESULTS: The unmatched RMT cohort had a greater freedom from ATA recurrence at 1 year (99% vs 90%, P = 0.001) and 3 years (94% vs 86%, P = 0.045). The matched RMT cohort had longer cardiopulmonary bypass (median: 215 [199 to 253] vs 170 [136 to 198] min, P < 0.001) and aortic cross-clamp (110 [98 to 124] vs 86 [71 to 102] min, P < 0.001) times but shorter intensive care time (48 [24 to 95] vs 71 [26 to 144] h, P = 0.001) and length of stay (8 [6 to 11] vs 10 [7 to 14] h, P < 0.001). More pacemakers (18% vs 4%, P < 0.001) and postoperative transfusions (57% vs 41%, P = 0.014) occurred in the MS cohort. The 30-day mortality (P = 0.651) and 8-year survival (P = 0.072) was not significantly different between the cohorts. CONCLUSIONS: Early 1-year and 3-year freedom from ATA recurrence was better in the RMT cohort compared with the MS cohort. Despite longer operative times, the RMT cohort had shorter lengths of stay, fewer postoperative transfusions, and fewer pacemakers placed.


Assuntos
Valva Mitral , Esternotomia , Humanos , Esternotomia/métodos , Valva Mitral/cirurgia , Procedimento do Labirinto , Resultado do Tratamento , Estudos Retrospectivos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos
4.
JTCVS Tech ; 20: 58-70, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37555041

RESUMO

Objective: To develop a minimally invasive, reproducible model of chronic severe mitral regurgitation (MR) that replicates the clinical phenotype of left atrial (LA) and left ventricular dilation and susceptibility to atrial fibrillation. Methods: Under transesophageal echocardiographic guidance, chordae tendinae were avulsed using endovascular forceps until the ratio of regurgitant jet area to LA area was ≥70%. Animals survived for an average of 8.6 ± 1.6 months (standard deviation) and imaged with monthly transthoracic echocardiography (TTE). Animals underwent baseline and preterminal magnetic resonance imaging. Terminal studies included TTE, transesophageal echocardiography, and rapid atrial pacing to test inducibility of atrial tachyarrhythmias. Results: Eight dogs underwent creation of severe MR and interval monitoring. Two were excluded-one died from acute heart failure, and the other had resolution of MR. Six dogs underwent the full experimental protocol; only one required medical management of clinical heart failure. MR remained severe over time, with a mean terminal regurgitant jet area to LA area of 71 ± 14% (standard deviation) and regurgitant fraction of 52 ± 11%. Mean LA volume increased over 130% (TTE: 163 ± 147%, P = .039; magnetic resonance imaging: 132 ± 54%, P = .011). Mean left ventricular end-diastolic volume increased by 38 ± 21% (P = .008). Inducible atrial tachyarrhythmias were seen in 4 of 6 animals at terminal surgery, and none at baseline. Conclusions: Within the 6 dogs that successfully completed the full experimental protocol, this model replicated the clinical phenotype of severe MR, which led to marked structural and electrophysiologic cardiac remodeling. This model allowed for precise measurements at repeated time points and will facilitate future studies to elucidate the mechanisms of atrial and ventricular remodeling secondary to MR and the pathophysiology of valvular atrial fibrillation.

5.
Ann Thorac Surg ; 116(2): 307-313, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36935027

RESUMO

BACKGROUND: Bipolar radiofrequency (RF) clamps are commonly used during surgical ablation for atrial fibrillation (AF). This study examined the efficacy of an irrigated bipolar RF clamp to create transmural lesions in an ex vivo human heart model. METHODS: Ten donor hearts, turned down for transplantation, were explanted and arrested with cold cardioplegia. The ablations of the Cox Maze IV procedure were performed using the Cardioblate LP (Medtronic, Inc) irrigated bipolar RF clamp. In the first 5 hearts, each lesion was created with a single application of RF, whereas in the remaining 5 hearts, each lesion was created with a double application of RF without unclamping. Each lesion was cross-sectioned and stained with 2,3,5-triphenyl-tetrazolium chloride to assess ablation depth and transmurality. RESULTS: A total of 100 lesions were analyzed. In the single-ablation group, 222 of 260 sections (85%) and 37 of 50 lesions (74%) were transmural. The efficacy improved significantly in the double-ablation group, in which 348 of 359 sections (97%, P < .001) and 46 of 50 lesions (92%, P = .017) were transmural. Overall, in nontransmural lesions, the epicardial fat thickness was significantly greater (1.69 ± 0.70 mm vs 0.45 ±0.10 mm, P < .001) than the transmural lesions. CONCLUSIONS: A single ablation on human atrial tissue with an irrigated bipolar RF clamp was insufficient to reliably create transmural lesions, but a double ablation significantly increased the lesion and section transmurality. Nontransmural lesions were associated with significantly thicker layers of epicardial fat, which likely decreased tissue energy delivery due to the higher resistance of fat to current flow.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Transplante de Coração , Ablação por Radiofrequência , Humanos , Ablação por Cateter/métodos , Doadores de Tecidos , Átrios do Coração/cirurgia , Fibrilação Atrial/cirurgia
7.
JTCVS Open ; 16: 292-302, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38204711

RESUMO

Objectives: The mechanism by which mitral valve (MV) disease leads to atrial fibrillation (AF) remains poorly understood. Delayed-enhancement cardiac magnetic resonance imaging (DE-MRI) has been used to assess left atrial (LA) fibrosis in patients with lone AF before catheter ablation; however, few studies have used DE-MRI to assess MV-induced LA fibrosis in patients with or without AF undergoing MV surgery. Methods: Between March 2018 and September 2022, 38 subjects were enrolled; 15 age-matched controls, 14 patients with lone mitral regurgitation (MR), and 9 patients with MR and AF (MR + AF). Indexed LA volume, total LA wall, and regional LA posterior wall (LAPW) enhancement were defined by the DE-MRI. One-way analysis of variance was performed. Results: LA volume and LA enhancement were associated (r = 0.451, P = .004). LA volume differed significantly between controls (37.1 ± 10.6 mL) and patients with lone MR (71.0 ± 35.9, P = .020 and controls and patients with MR + AF (99.3 ± 47.4, P < .001). The difference in LA enhancement was significant between MR + AF (16.7 ± 9.6%) versus controls (8.3 ± 3.9%, P = .006) and MR + AF versus lone MR (8.0 ± 4.8%, P = .004). Similarly, the was significantly more LAPW enhancement in the MR + AF (17.5 ± 8.7%) versus control (9.2 ± 5.1%, P = .011) and MR + AF versus lone MR (9.8 ± 6.0%, P = .020). Conclusions: Patients with MR + AF had significantly more total and LAPW fibrosis compared with both controls and lone MR. Volume and delayed enhancement were associated, but there was no difference between MR and MR + AF.

8.
Innovations (Phila) ; 17(5): 409-415, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36217760

RESUMO

OBJECTIVE: Expert consensus guidelines recommend surgical ablation (SA) for patients with symptomatic atrial fibrillation (AF), but less than half of patients with AF undergoing cardiac procedures receive concomitant SA. Complete isolation of the left atrial posterior wall (LAPW) has been shown to be the most critical part of the Cox maze procedure. The purpose of this study was to investigate the performance of a novel radiofrequency (RF) bipolar device, EnCompass™ (AtriCure, Inc., Mason, OH, USA), designed to isolate the LAPW in a single application. METHODS: Five adult pigs underwent SA in a beating heart model. After a single ablation, the heart was arrested, explanted, and stained with triphenyl-tetrazolium-chloride for histological assessment. Each lesion was sectioned, and the ablation depth, muscle, and fat thickness were determined. The lesion width, energy delivery, and ablation times were compared with those from a reference RF clamp (Synergy™, AtriCure). RESULTS: Transmurality was documented in 100% of lesions (5 of 5) and cross sections (160 of 160). Electrical isolation was documented in every instance. There was no evidence of clot, charring, or pulmonary vein stenosis. Compared with the reference clamp, the lesions created by the EnCompass™ clamp were 1.5 times wider on average. The average energy delivered was 5 times higher over a duration that was 4.5 times longer due to the increased volume of tissue ablated. CONCLUSIONS: The EnCompass™ clamp reproducibly created transmural isolation of the LAPW with a single application. This may allow for simplification of the SA strategy and increased adoption of AF treatment during concomitant surgery.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Suínos , Animais , Fibrilação Atrial/cirurgia , Átrios do Coração/cirurgia , Resultado do Tratamento
9.
JACC Heart Fail ; 10(9): 637-647, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36049815

RESUMO

BACKGROUND: Surgical mechanical ventricular assistance and cardiac replacement therapies, although life-saving in many heart failure (HF) patients, remain high-risk. Despite this, the difficulty in timely identification of medical therapy nonresponders and the dire consequences of nonresponse have fueled early, less selective surgical referral. Patients who would have ultimately responded to medical therapy are therefore subjected to the risk and life disruption of surgical therapy. OBJECTIVES: The purpose of this study was to develop deep learning models based upon commonly-available electronic health record (EHR) variables to assist clinicians in the timely and accurate identification of HF medical therapy nonresponders. METHODS: The study cohort consisted of all patients (age 18 to 90 years) admitted to a single tertiary care institution from January 2009 through December 2018, with International Classification of Disease HF diagnostic coding. Ensemble deep learning models employing time-series and densely-connected networks were developed from standard EHR data. The positive class included all observations resulting in severe progression (death from any cause or referral for HF surgical intervention) within 1 year. RESULTS: A total of 79,850 distinct admissions from 52,265 HF patients met observation criteria and contributed >350 million EHR datapoints for model training, validation, and testing. A total of 20% of model observations fit positive class criteria. The model C-statistic was 0.91. CONCLUSIONS: The demonstrated accuracy of EHR-based deep learning model prediction of 1-year all-cause death or referral for HF surgical therapy supports clinical relevance. EHR-based deep learning models have considerable potential to assist HF clinicians in improving the application of advanced HF surgical therapy in medical therapy nonresponders.


Assuntos
Aprendizado Profundo , Insuficiência Cardíaca , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Registros Eletrônicos de Saúde , Insuficiência Cardíaca/diagnóstico , Hospitalização , Humanos , Pessoa de Meia-Idade , Adulto Jovem
10.
Artigo em Inglês | MEDLINE | ID: mdl-36642681

RESUMO

OBJECTIVE: The Cox-Maze IV procedure (CMP-IV) is the most effective treatment for atrial fibrillation. Increased left atrial (LA) size has been identified as a risk factor for failure to restore sinus rhythm. This has biased many surgeons against ablation in patients with giant left atrium (GLA), defined as LA diameter >6.5 cm. In this study we aimed to define the efficacy of the CMP-IV in patients with GLA. METHODS: From April 2004 through March 2020, 786 patients with a documented LA diameter underwent elective CMP-IV, 72 of whom had GLA. Median follow-up duration was 4 years (interquartile range, 1-7 years). Recurrence was defined as any documented atrial tachyarrhythmia (ATA) lasting 30 seconds. ATA recurrence and survival were analyzed across GLA versus non-GLA groups. RESULTS: Median age at surgery was 65 (interquartile range, 56-73) years. Median LA diameter within the GLA group was 7.0 (range, 6.6-10.0) cm. There were no differences in rates of postoperative complications for the 2 groups, including rate of postoperative stroke and pacemaker placement (GLA 14%; non-GLA 12%; P = .682). A trend toward increased 30-day mortality in the GLA group did not reach statistical significance (GLA 6%; non-GLA 2%; P = .051). Freedom from ATAs at 5 years postoperatively was comparable for the 2 groups (GLA 82%; non-GLA 84%). CONCLUSIONS: The CMP-IV had good efficacy in patients with GLA. Our results suggest that LA diameter >6.5 cm should not preclude a patient from undergoing surgical ablation for atrial fibrillation.

11.
J Cardiovasc Electrophysiol ; 32(10): 2884-2894, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34041815

RESUMO

INTRODUCTION: Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia, and results in significant morbidity and mortality. The Cox-Maze IV procedure (CMP-IV) has been shown to have excellent efficacy in returning patients to sinus rhythm, but there have been few reports of late follow-up in sizable cohorts of patients with longstanding persistent AF, the most difficult type of AF to treat. METHODS AND RESULTS: Between May 2003 and March 2020, 174 consecutive patients underwent a stand-alone CMP-IV for longstanding persistent AF. Rhythm outcome was assessed postoperatively for up to 10 years, primarily via prolonged monitoring (Holter monitor, pacemaker interrogation, or implantable loop recorder). Fine-Gray regression was used to investigate factors associated with atrial tachyarrhythmia (ATA) recurrence, with death as a competing risk. Median duration of preoperative AF was 7.8 years (interquartile range: 4.0-12.0 years), with 71% (124/174) having failed at least one prior catheter-based ablation. There were no 30-day mortalities. Freedom from ATAs was 94% (120/128), 83% (53/64), and 88% (35/40) at 1, 5, and 7 years, respectively. On regression analysis, preoperative AF duration and early postoperative ATAs were associated with late ATAs recurrence. CONCLUSION: Despite the majority of patients having a long-duration of preoperative AF and having failed at least one catheter-based ablation, the stand-alone CMP-IV had excellent late efficacy in patients with longstanding persistent AF, with low morbidity and no mortality. We recommend consideration of stand-alone CMP-IV for patients with longstanding persistent AF who have failed or are poor candidates for catheter ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Átrios do Coração , Humanos , Procedimento do Labirinto , Recidiva , Resultado do Tratamento
12.
J Vasc Surg Cases Innov Tech ; 5(4): 549-552, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31867471

RESUMO

We report the management of symptomatic May-Thurner syndrome refractory to endovascular techniques with left gonadal vein to inferior vena cava bypass. The patient's presentation was exceptional-a young individual with end-stage renal disease status post four failed kidney transplants, dwindling options for dialysis access, and an unusable left thigh arteriovenous graft owing to severe lower extremity edema secondary to common iliac vein compression. Postoperatively, swelling was markedly alleviated and the thigh graft was functional. Discussed are endovascular and venous bypass techniques for management of May-Thurner-associated lesions, as well as approaches to end-stage hemodialysis access salvage.

13.
J Health Care Poor Underserved ; 28(1): 362-377, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28239007

RESUMO

BACKGROUND: Racial minorities and low-income individuals are generally less likely to have adequate cancer screening than Whites or higher-income individuals. PURPOSE: To examine the roles of medical mistrust and lack of provider continuity in cancer screening in a low-income minority population. METHODS: A total of 144 urban federally qualified health center patients completed a cross-sectional survey that included the Group Based Medical Mistrust Scale and questions on provider continuity and cancer-screening-history. RESULTS: Breast cancer screening was associated with continuity of care but not mistrust (respectively p = .002, p > .05); colon cancer screening was not significantly associated with either factor (p > .05). CONCLUSIONS: Findings suggest that among low-income minority adults continuity of care is more strongly associated with screening than medical mistrust. Shifting focus from medical mistrust-a patient-level issue-to establishing health care homes-a system-level issue-may be a more effective strategy for reducing racial and socioeconomic disparities in cancer screening.


Assuntos
Negro ou Afro-Americano/estatística & dados numéricos , Detecção Precoce de Câncer/estatística & dados numéricos , Assistência Centrada no Paciente/estatística & dados numéricos , Pobreza/estatística & dados numéricos , Confiança , Adulto , Continuidade da Assistência ao Paciente , Estudos Transversais , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Grupos Raciais/estatística & dados numéricos , Provedores de Redes de Segurança/estatística & dados numéricos , Fatores Socioeconômicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...