1.
Molecules ; 27(2)2022 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-35056810

RESUMO

Near infrared (NIR) spectroscopy is an important tool for predicting the internal qualities of fruits. Using aquaphotomics, spectral changes between linearly polarized and unpolarized light were assessed on 200 commercially grown yellow-fleshed kiwifruit (Actinidia chinensis var. chinensis 'Zesy002'). Measurements were performed on different configurations of unpeeled (intact) and peeled (cut) kiwifruit using a commercial handheld NIR instrument. Absorbance after applying standard normal variate (SNV) and second derivative Savitzky-Golay filters produced different spectral features for all configurations. An aquagram depicting all configurations suggests that linearly polarized light activated more free water states and unpolarized light activated more bound water states. At depth (≥1 mm), after several scattering events, all radiation is expected to be fully depolarized and interactions for incident polarized or unpolarized light will be similar, so any observed differences are attributable to the surface layers of the fruit. Aquagrams generated in terms of the fruit soluble solids content (SSC) were similar for all configurations, suggesting the SSC in fruit is not a contributing factor here.


Assuntos
Actinidia/química , Frutas/química , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Água/química , Luz
2.
Molecules ; 27(2)2022 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-35056819

RESUMO

Using the framework of aquaphotomics, we have sought to understand the changes within the water structure of kiwifruit juice occurring with changes in temperature. The study focuses on the first (1300-1600 nm) and second (870-1100 nm) overtone regions of the OH stretch of water and examines temperature differences between 20, 25, and 30 °C. Spectral data were collected using a Fourier transform-near-infrared spectrometer with 1 mm and 10 mm transmission cells for measurements in the first and second overtone region, respectively. Water wavelengths affected by temperature variation were identified. Aquagrams (water spectral patterns) highlight slightly different responses in the first and second overtone regions. The influence of increasing temperature on the peak absorbance of the juice was largely a lateral wavelength shift in the first overtone region and a vertical amplitude shift in the second overtone region of water. With the same data set, we investigated the use of external parameter orthogonalisation (EPO) and extended multiple scatter correction (EMSC) pre-processing to assist in building temperature-independent partial least square regression models for predicting soluble solids concentration (SSC) of kiwifruit juice. The interference component selected for correction was the first principal component loading measured using pure water samples taken at the same three temperatures (20, 25, and 30 °C). The results show that the EMSC method reduced SSC prediction bias from 0.77 to 0.1 °Brix in the first overtone region of water. Using the EPO method significantly reduced the prediction bias from 0.51 to 0.04 °Brix, when applying a model made at one temperature (30 °C) to measurements made at another temperature (20 °C) in the second overtone region of water.


Assuntos
Actinidia/química , Sucos de Frutas e Vegetais/análise , Extratos Vegetais/análise , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Temperatura , Água/química , Análise dos Mínimos Quadrados
3.
Appl Spectrosc ; 67(8): 993-6, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23876738

RESUMO

We investigated the stability of light transmission through Intralipid-based optical phantoms in the wavelength range of 400-950 nm at temperatures between 35 and 70 °C. Optical phantoms are materials commonly used to simulate the light scattering and absorption properties of biological materials. These simulations require the phantom to be optically stable. We demonstrate that the scattering properties of Intralipid remain stable at higher temperatures, varying less than 0.5%. We also present results that show this is not the case for absorption below 700 nm at 35 and 70 °C, with greater instability at 70 °C. For example, at 500 nm, the light intensity transmitted through 15 mm of Intralipid dropped 39% over 12 h. We demonstrate that oxidation of fatty acids in Intralipid could account for this effect and show, by flushing the system continuously with nitrogen gas, the instability is reduced.


Assuntos
Imagem Óptica/métodos , Imagens de Fantasmas , Fosfolipídeos/química , Óleo de Soja/química , Pesquisa Biomédica , Emulsões/química , Ácidos Graxos , Temperatura Alta , Luz , Oxirredução , Espalhamento de Radiação
4.
J Biomed Opt ; 14(2): 024041, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19405769

RESUMO

We present a wavelength-tunable frequency-domain instrument for the characterization of liquid turbid media. The instrument employs a tunable titanium-sapphire laser modulated by an acousto-optic modulator. The absorption and reduced scattering coefficient of Intralipid(R) 20%, diluted to concentrations of 0.94 to 4.00%, are measured over the wavelength range 710 to 850 nm at 10-nm intervals. The standard measurement errors for the absorption and reduced scattering coefficients are 1 and 2.5%, respectively. Extrapolation to 0% Intralipid(R) concentration gives an absorption coefficient that closely follows that of water, overestimating the absorption of pure water by less than 10%. The reduced scattering coefficient is compared at 750 nm with published results and is found consistent within the experimental error. We compare the reduced scattering coefficient to an estimate based on Mie theory and find the reduced scattering coefficient underestimated the Mie theory result by about 9%.


Assuntos
Algoritmos , Lasers , Nefelometria e Turbidimetria/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Nefelometria e Turbidimetria/métodos , Fótons , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Appl Spectrosc ; 62(9): 1008-12, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18801240

RESUMO

Calibrating the wavelength scale of an array spectrometer typically involves measurements of lines at well-known wavelengths from a calibration lamp such as a mercury-argon source. This process is relatively straightforward when the lines are well separated, relative to the bandwidth of the spectrometer. When the spectrometer's bandwidth is large, compared with the distance between calibration wavelengths, it becomes increasingly difficult to accurately locate lines in the calibration spectrum. Even calibrations for instruments with a modest bandwidth of 12 nm can be difficult. Here we present results from a simple approach to improve the accuracy of wavelength calibration for an instrument with a large bandwidth (12 nm, center-to-center pixel spacing 3.3 nm). A monochromator has been used to filter the source so that each calibration line can be measured separately. For ten spectrometers, we were able to achieve accuracy better than 0.12 nm, or 0.09 nm on average; this is less than 3% of the pixel spacing. We anticipate this approach will be useful for improving the accuracy of measurements on array spectrometers and particularly in transferring multivariate calibrations between instruments.


Assuntos
Filtração/instrumentação , Filtração/normas , Análise Espectral/instrumentação , Análise Espectral/normas , Calibragem , Nova Zelândia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
J Biomed Opt ; 13(3): 034016, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18601561

RESUMO

The temperature dependence (30 to 40 degrees C) of near-infrared spectra (500 to 1100 nm) of whole human blood, including red blood cells with intact physiological function, is investigated. Previous studies have focused on hemoglobin solutions, but the operation of red blood cells is critically dependent on intact cell membranes to perform normal oxygen transport and other physiological functions. Thus measurements of whole blood are more directly related to changes that occur in vivo. In addition to the response of hemoglobin to temperature in the spectra, a temperature response from water in the plasma is also detected. The temperature response of the water absorption at 960 nm is approximately ten times smaller than the temperature response of the oxyhemoglobin component in the blood at 610 nm. However, it is the most significant temperature effect between 800 and 1000 nm. This work will aid the precision and understanding of full spectrum near-infrared measurements on blood.


Assuntos
Análise Química do Sangue , Fenômenos Fisiológicos Sanguíneos , Oxiemoglobinas/química , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Água/química , Humanos , Temperatura
7.
Am Fam Physician ; 74(6): 985-90, 2006 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-17002033

RESUMO

A common dilemma in clinical medicine is whether to treat asymptomatic patients who present with bacteria in their urine. There are few scenarios in which antibiotic treatment of asymptomatic bacteruria has been shown to improve patient outcomes. Because of increasing antimicrobial resistance, it is important not to treat patients with asymptomatic bacteriuria unless there is evidence of potential benefit. Women who are pregnant should be screened for asymptomatic bacteriuria in the first trimester and treated, if positive. Treating asymptomatic bacteriuria in patients with diabetes, older persons, patients with or without indwelling catheters, or patients with spinal cord injuries has not been found to improve outcomes.


Assuntos
Bacteriúria , Adulto , Anti-Infecciosos/uso terapêutico , Bacteriúria/complicações , Bacteriúria/diagnóstico , Bacteriúria/tratamento farmacológico , Bacteriúria/epidemiologia , Cateteres de Demora/efeitos adversos , Complicações do Diabetes/diagnóstico , Complicações do Diabetes/epidemiologia , Feminino , Humanos , Masculino , Gravidez , Complicações Infecciosas na Gravidez/tratamento farmacológico , Complicações Infecciosas na Gravidez/epidemiologia , Fatores de Risco , Traumatismos da Medula Espinal/complicações
SELEÇÃO DE REFERÊNCIAS